• Title/Summary/Keyword: Egress simulation

Search Result 65, Processing Time 0.019 seconds

Evaluation on Fire Available Safe Egress Time of Commercial Buildings based on Artificial Neural Network (인공신경망 기반 상업용 건축물의 화재 피난허용시간 평가)

  • Darkhanbat, Khaliunaa;Heo, Inwook;Choi, Seung-Ho;Kim, Jae-Hyun;Kim, Kang Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.111-120
    • /
    • 2021
  • When a fire occurs in a commercial building, the evacuation route is complicated and the direction of smoke and flame is similar to that of the egress route of occupants, resulting in many casualties. Performance-based evacuation design for buildings is essential to minimize human casualties. In order to apply the performance-based evacuation design to buildings, it requires a complex fire simulation for each building, demanding a large amount of time and manpower. In order to supplement this, it would be very useful to develop an Available Safe Egress Time (ASET) prediction model that can rationally derive the ASET without performing a fire simulation. In this study, the correlations between fire temperature with visibility and toxic gas concentration were investigated through a fire simulation on a commercial building, from which databases for the training of artificial neural networks (ANN) were created. Based on this, an ANN model that can predict the available safe egress time was developed. In order to examine whether the proposed ANN model can be applied to other commercial buildings, it was applied to another commercial building, and the proposed model was found to estimate the available safe egress time of the commercial building very accurately.

A Study on the Evacuation of People used the evacuation model on Fire in Shopping Mall (피난 모델을 이용한 대형할인매장의 화재시 피난에 관한 연구)

  • 이수경;이상준
    • Fire Science and Engineering
    • /
    • v.14 no.4
    • /
    • pp.17-22
    • /
    • 2000
  • For life safety design of shopping mall, we selected a shopping mall, and calculated the evacuation time of means of egress. It is calculated by two kind of evacuation method. One is the computer simulation model, EXODUS. The other is Japan's method. Study way is a model structure study, selecting real shopping mall and setting scenario, calculating the evacuating time. result of study, evaluation time is very high. Therefore we confirmed that the building of means of egress is not fit to evacuation more the capacity of setting population.

  • PDF

A Study on the Synchronization of GFP Signal in NG-SDH System (NG-SDH시스템에서의 GFP 신호동기에 관한 연구)

  • Lee Chang-Ki;Ko Je-Soo
    • The KIPS Transactions:PartC
    • /
    • v.12C no.1 s.97
    • /
    • pp.53-62
    • /
    • 2005
  • The NG-SDH system requires signal synchronization to synchronize incoming ethernet signal with GFP frame. The foreign nation research completes a chipset development until now and it secures a relation technique, but it does not secure a relation technique from domestic. Therefore, in this paper, we presented with signal synchronization method of Ethernet signal through GFP frame. We knew that the synchronized method of Ethernet signal through GFP-F must apply ingress & egress buffer and GFP Idle. We understood that the synchronized method of Ethernet signal through GFP-T must apply GFP Idle and $65B{\_}PAD$, and require maximum 3-bit addition & deletion of idle. Also we showed signal synchronization realization through simulation and obtained MTIE/TDEV characteristics and peak to peak jitter in egress output.

Development of the Program(FDS2EXODUS) for Generating Hazard condition file of Building-EXODUS code based on the FDS Fire-simulation Data (화재모사전용 FDS code의 계산값을 이용하여 피난해석 BuildingEXODUS code의 피난의 환경조건 파일을 생성하는 프로그램(FDS2EXODUS) 개발)

  • Kim, H.B.;Jang, Y.J.;Jung, W.S.;Park, W.H.;Lee, D.H.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.570-575
    • /
    • 2009
  • In this paper shows the development of the Program(FDS2EXODUS) for Generating Hazard condition file of BuildingEXODUS code based on the FDS Fire-simulation Data. The program were applied with numerical method to translate from FDS to BuildingEXODUS. Using both single or multi block meshes of FDS get to be possible. For application of fire effect, the fire data were loaded directly to BuildingEXODUS in the case of FDS code with using this Program(FDS2EXODUS). It was very convenient to input to BuildingEXODUS and could be reduced the procedure of egress simulation from fire disaster.

  • PDF

A Study on the Improvement of the Evacuation in Ward of the General Hospital (종합병원 병동부 피난환경 개선에 관한 연구)

  • Kim, Woo-Seok;Chai, Choul-Gyun
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.202-208
    • /
    • 2006
  • The purpose of this study is to suggest architectural planning guideline for the improvement of the evacuation environment in a ward. To suggest of guideline, the problem of irrational domestic criteria is searched according to compare National fire code (NFPA101, Life safety code) with Korea building law. This study includes stairs, corridors and exit door etc. but excludes fire facilities. To verify effectiveness of suggested guideline, egress simulation is run that based on databases according to literature survey. The results of this study could be summarized as follow: Suggested guidelines are subdivision(fire partition), evacuation by elevator, secure useful waiting space of elevator hall and smokeproof enclosures, the corridor is divided by fire or smoke barriers corridor from hazardous room, only wheeled items are arranged in corridors of a ward story. The result of computer simulation for suggested guidelines verify that egress time can be decreased 20% or above.

Risk Evaluation and Analysis on Simulation Model of Fire Evacuation based on CFD - Focusing on Incheon Bus Terminal Station (CFD기반 화재 대피 시뮬레이션 모델을 적용한 위험도 평가 분석 -인천터미널역 역사를 대상으로)

  • Kim, Min Gyu;Joo, Yong Jin;Park, Soo Hong
    • Spatial Information Research
    • /
    • v.21 no.6
    • /
    • pp.43-55
    • /
    • 2013
  • Recently, the research to visualize and to reproduce evacuation situations such as terrorism, the disaster and fire indoor space has been come into the spotlight and designing a model for interior space and reliable analysis through safety evaluation of the life is required. Therefore, this paper aims to develop simulation model which is able to suggest evacuation route guidance and safety analysis by considering the major risk factor of fire in actual building. First of all, we designed 3D-based fire and evacuation model at a subway station building in Incheon and performed fire risk analysis through thermal parameters on the basis of interior materials supplied by Incheon Transit Corporation. In order to evaluate safety of a life, ASET (Available Safe Egress Time), which is the time for occupants to endure without damage, and RSET (Required Safe Egress Time) are calculated through evacuation simulation by Fire Dynamics Simulator. Finally, we can come to the conclusion that a more realistic safety assessment is carried out through indoor space model based on 3-dimension building information and simulation analysis applied by safety guideline for measurement of fire and evacuation risk.

Implementation of MPOA for Supporting Various Protocols over ATM (ATM 상에서 다양한 프로토콜을 지원하기 위한 MPOA의 구현)

  • Lim, Ji-Young;Kim, Mi-Hee;Choi, Jeong-Hyun;Lee, Mee-Jeong;Chae, Ki-Joon;Choi, Kil-Young;Kang, Hun
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.1
    • /
    • pp.181-199
    • /
    • 2000
  • In this paper, we implemented and tested MPOA(MutiProtocol Over ATM) standardized in ATM Forum, which provides service for various layer 3 protocols as well as legacy LAN applications over ATM networks. The functions of MPCs(MPOA Clients) and MPSs(MPOA Servers) which are the components in MPOA systems are implemented. MPCs are located at the edge device and MPOA hosts and MPSs exist in routers. The implemented MPCs have the functions such as exchances of primitives between an LEC(LAN Emulation Client) and an MPC, management and maintenance of Egress/Ingress cache, default transmission through LECs and shortcut transmission. Assuming that routing, convergence and NHRP(Next Hop Resolution Protocol) functions exist in routers, the implemented MPSs have the functions such as exchanges of primitives between an LEC and an MPC, conversion and exchanges of frames between MPOA and NHRP, and management and maintenance of Egress/Ingress cache. All of the possible scenarios are made up to test whether they run correctly. The implemented system is tested by simulation according to the scenarios.

  • PDF

A Study on ASET(available safe egress time) for Subway Station of Light Weight Railcar Using FDS (FDS를 이용한 경량철도 지하역사의 피난허용시간 연구)

  • Kim, Chi-Hun;Lee, Duck-Hee;Jung, Woo-Sung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.361-366
    • /
    • 2011
  • 본 연구에서는 무인운영이 예정되어 있는 경량철도 지하역사 화재 시 안전대책을 강구하기 위하여 다양한 시나리오의 화재상황을 모사하여 FDS 사용코드를 이용해 화재유동현상을 분석하였다. 해석경계조건은 전동차 내부공간을 포함한 지하 3개 층과 설계에 반영된 환기설비를 적용하였으며, 약 500만 개의 격자를 34개 블록으로 나누어 계산하였다. 비상탈출 동선을 파악하여 주요 위치에서 피난경로상의 각 층 바닥으로 부터 1 m 높이의 한계온도와 연기층의 도달시간을 시나리오 별로 분석하여 보았다.

  • PDF

A Study on Characteristics of Spatial Configuration and Human Evacuation Behavior in Multi-Plex Theater of Jinju (진주지역 복합영화관의 공간구조와 피난행태특성에 관한 연구)

  • Ahn, Eun Hee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.7 no.3
    • /
    • pp.93-100
    • /
    • 2005
  • The purpose of this study is to investigate specific crowding areas resulted from diverse physical factors of multi-plex theaters in a fire evacuation, and more accurately predict the evacuation route of people. To achieve these purpose, the architectural characteristics of three multi-plex theaters in Jinju have been chosen, and the evacuation experiments through the computer simulation called Simulex were carried out for each on the these theaters. The conclusions from this study are as follows: (1) Crowding usually happens cross areas between theater inside and corridors, and Crowding rate depending on the number of cross areas. (2) It is necessary to design the escape routes being employed ordinary times. And the egress routes planning should be integrated into space programming at the early stage of building design.

  • PDF