• Title/Summary/Keyword: Effluent rate

Search Result 551, Processing Time 0.024 seconds

Evaluation of pure oxygen with MBR(Membrane Bio Reactor) process for anaerobic digester effluent treatment from food waste (순산소의 MBR(Membrane Bio Reactor) 공정 적용을 통한 음식물류 폐기물 혐기성소화 유출수 처리 평가)

  • Park, Seyong;Kim, Moonil;Park, Seonghyuk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.3
    • /
    • pp.5-16
    • /
    • 2021
  • In this study, the applicability of the MBR(Membrane Bio Reactor) process of oxygen dissolve was evaluated through comparison and evaluation of the efficiency of oxygen dissolve device and conventional aeration device in the explosive tank within the MBR process. The organic matter and ammonia oxidation by oxygen dissolve device were evaluated, and the efficiency of persaturation was evaluated by applying real waste water (anaerobic digester effluent treatement from food waste). SCOD and ammonia removal rates for oxygen dissolve device and conventional aeration device methods were similar. However, it was determined that the excess sludge treatment cost could be reduced as the yield of microorganisms by oxygen dissolve device is about 0.03 g MLSS-produced/g SCOD-removed lower than that of microorganisms by conventional aeration device. The removal rates of high concentrations of organic matter (4,000 mg/L) and ammonia (1,400 mg/L) in anaerobic digester effluent treatment from food waste were compared to the conventional aeration device and the oxygen dissolve device organic matter removal rate was approximately 13% higher than that of the conventional aeration device. In addition, for MLSS, the conventional aeration device was 0.3 times higher than for oxygen dissolve device. This is believed to be due to the high progress of sludge autooxidation because the dissolved oxygen is sufficiently maintained and supplied in the explosive tank for oxygen dissolve device. Therefore, it was determined that the use of oxygen dissolve device will be more economical than conventional aeration device as a way to treat wastewater containing high concentrations of organic matter.

Nutrient Recovery from Sludge Fermentation Effluent in Upflow Phosphate Crystallization Process (상향류 인 결정화공정을 이용한 슬러지 발효 유출수로 부터의 영양소 회수)

  • Ahn, Young-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.8
    • /
    • pp.866-871
    • /
    • 2006
  • The nutrient recovery in phosphate crystallization process was investigated by using laboratory scale uptlow reactors, adopting sequencing batch type configuration. The industrial waste lime was used as potential cation source with magnesium salt($MgCl_2$) as control. The research was focused on its successful application in a novel integrated sludge treatment process, which is comprised of a high performance fermenter followed by a crystallization reactor. In the struvite precipitation test using synthetic wastewater first, which has the similar characteristics with the real fermentation effluent, the considerable nutrient removal(about 60%) in both ammonia and phosphate was observed within $0.5{\sim}1$ hr of retention time. The results also revealed that a minor amount(<5%) of ammonia stripping naturally occurred due to the alkaline(pH 9) characteristic in feed substrate. Stripping of $CO_2$ by air did not increase the struvite precipitation rate but it led to increased ammonia removal. In the second experiment using the fermentation effluent, the optimal dosage of magnesium salt for struvite precipitation was 0.86 g Mg $g^{-1}$ P, similar to the mass ratio of the struvite. The optimal dosage of waste lime was 0.3 g $L^{-1}$, resulting in 80% of $NH_4-N$ and 41% of $PO_4-P$ removal, at about 3 hrs of retention time. In the microscopic analysis, amorphous crystals were mainly observed in the settled solids with waste lime but prism-like crystals were observed with magnesium salt. Based on mass balance analysis for an integrated sludge treatment process(fermenter followed by crystallization reactor) for full-scale application(treatment capacity Q=158,880 $m^3\;d^{-1}$), nutrient recycle loading from the crystallization reactor effluent to the main liquid stream would be significantly reduced(0.13 g N and 0.19 g P per $m^3$ of wastewater, respectively). The results of the experiment reveal therefore that the reuse of waste lime, already an industrial waste, in a nutrient recovery system has various advantages such as higher economical benefits and sustainable treatment of the industrial waste.

Feasibility Study of Wetland-pond Systems for Water Quality Improvement and Agricultural Reuse (습지-연못 연계시스템에 의한 수질개선과 농업적 재이용 타당성 분석)

  • Jang, Jae-Ho;Jung, Kwang-Wook;Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.3 s.108
    • /
    • pp.344-354
    • /
    • 2004
  • A pilot study was performed from September 2000 to April 2004 to examine the feasibility of the wetland-pond system for the agricultural reuse of reclaimed water. The wetland system was a subsurface flow type, with a hydraulic residence time of 3.5 days, and the subsequent pond was 8 $m^3$ in volume (2 m ${\times}$ 2 m ${\times}$ 2 m) and operated with intermittent-discharge and continuous flow types. The wetland system was effective in treating the sewage; median removal efficiencies of $BOD_5$ and TSS were above 70.0%, with mean effluent concentrations of 27.1 and 16.8 mg $L^{-1}$, respectively, for these constituents. However, they did often exceed the effluent water quality standards of 20 mg $L^{-1}$. Removal of T-N and T-P was relatively less effective and mean effluent concentrations were approximately 103.2 and 7.2 mg $L^{-1}$, respectively. The wetland system demonstrated high removal rate (92 ${\sim}$ 90%) of microorganisms, but effluent concentrations were in the range of 300 ${\sim}$ 16,000 MPN 100 $mL^{-1}$ which is still high for agricultural reuse. The subsequent pond system provided further treatment of the wetland effluent, and especially additional microorganisms removal in addition to wetland-pond system could reduce the mean concentration to 1,000 MPN 100 $mL^{-1}$ from about $10^5$ MPN 100 $mL^{-1}$ of wetland influent. Other parameters in the pond system showed seasonal variation, and the upper layer of the pond water column became remarkably clear immediately after ice melt. Overall, the wetland system was found to be adequate for treating sewage with stable removal efficiency, and the subsequent pond was effective for further polishing. This study concerned agricultural reuse of reclaimed water using natural systems. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, wetland- pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water in rural area.

Continuous Water Toxicity Monitoring Using Immobilized Photobacterium phosphoreum

  • Kim, Se-Kwon;Lee, Baek-Seok;Lee, Jeong-Gun;Seo, Hyung-Joon;Kim, Eun-Ki
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.2
    • /
    • pp.147-150
    • /
    • 2003
  • Water toxicity monitoring based on the continuous cultivation of Photobacterium phorphoreum is presented. Normally, after 10 days of operation, a dark variant, which emits no light, appears and dominates the population, resulting in a rapid decrease in bioluminescence. Therefore, to overcome this problem, a fluidized-bed reactor is used in which alginate-immobilized cells are grown and leaking cells are continuously released into the effluent Experimental results revealed that the dominance of dark variants was suppressed inside the immobilized beads, thereby mitigating the rapid loss of bioluminescence. Plus, a high dilution rate (1.2 h$\^$-1/) prevented the occurrence of other microbial contamination in the reactor The concentration and bioluminescence of the released cells were sufficient to measure the water toxicity for more than 4 weeks.

The Treatment of Textile Wastewater by Electrocoagulation Process (전해응집공정을 이용한 염색폐수의 처리)

  • 이용택;한승우;조영개;이현문;김태근;손인식;양병수
    • Journal of Environmental Science International
    • /
    • v.9 no.4
    • /
    • pp.359-363
    • /
    • 2000
  • This research studied the characteristics and applicability of electrocoagulation using aluminium electrode for the color and COD removal in textile wastewater. Electrocoagulation reactor used two different electrode, Fe and Al, since in the general chemical wastewater treatment, aluminium and ferrous salts were used as coagulants. Aluminium electrode showed higher removal efficiency of color and COD than ferrous electrode did. The COD and color removal efficiency improved at the 0.192A/$dm^2$ current density. Thus, the electrocoagulation process with bipolar aluminium electrode showed better efficiency in the decolorization and COD removal rate of textile wastewater effluent than custom coagulants did.

  • PDF

A study on determining the optimum mixing ratio of carbon source for anaerobic treatment (혐기성처리를 위한 탄소원의 최적 혼합비율 결정에 관한 연구)

  • 김은호;장성호
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.3
    • /
    • pp.31-38
    • /
    • 1999
  • The purpose of this study were to determine the optimum mixing ratio of sewage sludge and papermill sludge as carbon source required to SRB in treating abandoned mine drainage with natural purification wetland. If mixing sewage sludge/papermill sludge 2.0 SO42- reduced 46.2%, and then 30% in mixing ratio 0.5.Because sewage sludge was faster biodegradability than papermill sludge, effluent SCOD was 40mg/L in mixing ratio 0.5, and after that was all but regular. pH and ORP were almost neutral and -160mV, but after that was all but regular and it indicated that SRB activity was suitable. Fe removal rate was 60% in mixing ratio 2.0, and 54% in mixing ratio 0.5. In point of carbon source supply, It indicated that mixing ration 0.5 was considered as the most appropriate, because degradability of swewage sludge under short time was higher than that of papermill sludge.

  • PDF

Pure Isolation, Identification and Culture Characteristics of Ethylene Glycol Degrading Bacteria (Ethylene Glycol 분해균주의 순수분리.동전 및 배양특성)

  • 류원률;최장승;주무환
    • KSBB Journal
    • /
    • v.13 no.5
    • /
    • pp.518-523
    • /
    • 1998
  • A large quantity of ethylene glycol(EG) is remained in the effluent after pretreating polyester weight-loss wastewater physicochemically in the fist stage and must be treated biologically in the second stage. Therefore, an excellent EG-utilizing bacteria strain was isolated from the natural system and the optimal culture conditions of the strain were investigated. The optimal culture conditions of temperature, pH, and nitrogen source were found to be 35$^{\circ}C$, 7.5 and ammonium chloride, respectively, when CODCr removal efficiency was more than 90%. The growth of stains and EG removal efficiency was slightly improved by adding elements such as niacin and biotin. With increasing inoculation size in a batch culture, the removal efficiency of EG was conspicuously increased. Growth rate was inhibited when the initial concentration of EG was more then 30g/L. The strain was identified as Pseudomonas sp. based on morphological and biological characteristics and named as Pseudomonas sp. EG1.

  • PDF

Clean-up of Contaminated Groundwater by Permeable Reactive Barrier (투수성 반응벽에 의한 오염지하수 복원효과 분석)

  • 정하익;김상근
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.542-547
    • /
    • 2000
  • It has become interested in the concept of permeable barriers for the containment and/or destruction of contaminated groundwater. The purpose of these trench-like barriers is to provide in situ capture and possibly destruction of the contaminant while preserving groundwater flow to uncontaminated zones. For instance, a trichloreethylene(TCE) plume may be contained by a permeable in which reactive iron reduces TCE to ethylene and ethane, compounds which can be easily biodegraded. The objective of this research is to examine the feasibility of using zero-valent iron as a clean-up media in permeable reactive barrier system. A series of laboratory column tests are performed. The concentration of influent and effluent water and the rate of clean up are analysed from these test results. The experimental result shows that the majority of the contamination in groundwater is removed in the reactor. And it shows the corresponding increase in the concentration of chloride ions through the reactor. Results from this study indicate that permeable reactive barrier containing admixtures of zero-valent iron and other materials can effectively clean up groundwater contaminated with organic compounds.

  • PDF

The Submerged Biofilm Process using Oyster-Shell Media for Wastewater Treatment and Prediction (굴패각을 담체로 사용한 침적고정 생물막공법 및 예측)

  • 문병현;이택순
    • Journal of Environmental Science International
    • /
    • v.6 no.6
    • /
    • pp.671-678
    • /
    • 1997
  • This study was conducted to use oyster shell as media for biological wastewater treatment. The comparison between the removal efficiencies of the activated sludge and the submerged biofilm process with oyster shell media (5% of reactor volume) for domestic sewage treatment was made. The contaminant removal efficiencies of the submerged process were higher than that of the activated sludge process. And the removal efficiencies of the submerged biofilm process with oyster shell media of 10% and 18% were Investigated at various loading rate. The removal efficiencies of 10% were higher than that of the 18% during the experimental period. The effluent concentration from the sub- merged bloom process using oyster shell media was prediceted by the Stover-Kincannon model.

  • PDF

A Study on Desulfurization and Denitrification of Flue Gas in Industry Boiler (산업용 보일러의 배연탈황 및 탈질에 관한 연구)

  • 이태호;정순형;정흥기
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.99-104
    • /
    • 1995
  • The objective of this study was to investigate the effect on denuclearization and decertification of flue gas by utilizing Mg( OH)$_{2}$ and NaOH as reagents in industrial boiler. We used packed absorber with Tellerette in all cases. And pH of circulation solution, rate of liquid per gas in absorber, COD concentration by pH variation in oxidation basin were inves- tigated. The following conclusions were obtained from experimental results: 1. Concerning running cost for reagents, Mg( OH)$_{2}$ reagent for treatment of flue gas was more economical than NaOH. 2. While Mg( OH )$_{2}$ and NaOH as absorbents were used, then the ratio of denuclearization was 96 and 97% respectively and nitrification was recorded 29 and 25% . 3. In this absorption tests the optimum condition for ratio of liquid per gas, pH and nonregenerable salt concentration of circulation solution were 3.6ℓ /Nm$^{3}$, 6.0, 0.5∼1.0% respectively, 4. Initial COD in oxidation basin was 800 ∼ 1,00099ut after adjusting to pH 7.0, COD of effluent water was less than 20ppm.

  • PDF