• Title/Summary/Keyword: Efficiency of operations

Search Result 1,344, Processing Time 0.03 seconds

A Burn-in Test System with Dynamic Bone Allocation (동적 존 할당이 가능한 번인 시험 시스템)

  • Oh, Sam-Kweon;Shin, Joong-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.75-80
    • /
    • 2009
  • Bum-in test is one for eliminating semiconductor devices that are subject to early failures and other operational problems; it is usually carried out on the devices by imposing severe test conditions such as elevated voltages, temperatures, and time. In order for such a test to be performed, each burn-in board having devices to be tested, needs to be inserted into a corresponding slot. A set of such slots is called a zone. The slots comprising a zone can only have the burn-in boards with the devices of the same type. In order to test many different types of semiconductor devices, it is desirable to build a burn-in test system to have as many zones as possible. A zone controller controlling a zone, is a device that performs a burn-in test and collects test results. In case of existing systems, each zone controller takes care of a zone that consists of a fixed number of slots. Since a zone controller is, in most cases, embedded into a workstation that controls the overall testing process, adding new zone controllers is restricted by the spaces for them. As a way to solve or alleviate these problems, a dynamic zone system in which the number of slots in a zone can be dynamically allocated, is presented. This system maximizes the efficiency of system utilization, by altering the number of slots and hence minimizing the idle slots of a zone. In addition, all the test operations being performed must be aborted for maintenance in existing systems. In dynamic zone systems, however, a separate and independent maintenance is allowed for each slot, as long as the main power supply system has no problem.

An Analysis on Signal Control Efficiency in a Three-Leg Intersection Adopting Pedestrian Push-Button System Following Pedestrian volume (3지 교차로에서 보행자 교통량에 따른 보행자작동신호기를 이용한 신호제어효율에 관한 분석)

  • Kim, Eung-Cheol;Cho, Han-Seon;Jung, Dong-Woo;Kim, Hyoung-Soo
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.121-128
    • /
    • 2009
  • This study has proposed the signal operating system to use both semi-actuated signal control and pedestrian push-button as a way to make up for the problems of 3 leg intersections which are operated inefficiently in the signal operation, one of the methods of traffic operations. In case of the semi-actuated signal control, it can reduce delay inside the intersection by serving to uncongested traffic on the main road where there is not much traffic volume on the secondary road and push-button signal can reduce unnecessary waiting time it could happen to vehicles by operating it though there is no pedestrian. Quantitative analysis was tried regarding the average delay reduction per vehicle using VISSIM, microscopic simulation program regarding how much effect it has compared with the existing signal control system and semi-actuated signal control system when the above two advantages are collected. The field test was performed for one three-leg intersection of Incheon. According to respectively signal control method pedestrian traffic changed and executed a sensitivity analysis. The result which compares the average delay time per a vehicle of scenarios, the signal control method of using the pedestrian push-button system in comparison with the fixed signal control method showed to decrease effect of a minimum 3.7 second (10%), a maximum 5.8 second (16%). When the pedestrian traffic volume was 20% or less of the measurement traffic volume, The signal control method of using the pedestrian push-button system appeared to be more efficient the semi-actuated signal control with object intersection.

  • PDF

Development and Full-scale Application of the Alternative Carbon Source Based on the Substrate Compatibility (미생물 순응 호환성에 기반한 대체탄소원 개발 및 실용화 사례)

  • Jung, In-Chul;Jo, Hyeon-Gil;Lee, Du-Ho;Kang, Dong-Hyo;Lim, Keun-Taek;Lee, Sung-Hak;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.5
    • /
    • pp.491-498
    • /
    • 2005
  • J sewage treatment plant (WWTP) in Busan has used methanol as an external carbon source for the biological denitrification process. Methanol is widely used. but rather expensive and very dangerous in handling. Therefore, it has been required that the economic alternative carbon source must be developed. By-product from a fine chemical industry can be Purified by removing high molecular weight substances using the ultrafilter membrane separation process and RBDCOD fraction becomes $98{\sim}99%$ of COD substances in the purified by-product. The purified by-product containing three types of alcohols, methanol, prophylenglycol and methoxypropanol; showed similar chemical characteristics to the methanol, a main external carbon source, in biodegradation pathway. Shown above, the compatibility between main and alternative carbon sources has been achieved. Also very short or no adaptation period is necessary in the case of exchanging these carbon sources. The compatibility between external carbon sources is an essential element for stabilizing WWTP operations. During the full-scale application test of the by-product, the alternative carbon source line got on par with the treatment efficiency of the methanol line. With the test result, J-WWTP changed methanol to a fine chemical by-product, in two out of three J-WWTP lines. Moreover, it is expected that 55.4% of the external carbon source cost reduction can be achieved in the alternative carbon source applied lines.

A Study on the Establishment of the Technology Road Map for Container Ports in Korea - Focusing on the Logistics and the Handling Equipment in Ports - (국내 컨테이너 항만기술 로드맵 수립 연구 - 항만물류 및 장비기술을 중심으로 -)

  • Choi, Sang-Hei;Ha, Tae-Young;Won, Seung-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.33 no.3
    • /
    • pp.199-206
    • /
    • 2009
  • Since Emma Maersk, which is a container vessel capable of holding a freight capacity of 11,000 TEU, was launched early last year, the appearance of the ULCS (Ultra Large Container Ship) will be expected in 5 years. That requires the high productivity, the high technology, the automation, and the high efficiency in port operations. GTO (Global Terminal Operator) and port equipment companies are striving for the prior occupation of the port market and the development of the port technology. Within the country, however, there has been few systematic, analytic, and detailed technology road map, and the effective execution of the development policy for the port technology and the activation of port industries has not been achieved. In this study, we deduces the development subject of the domestic port technology and analyzes the priority of them. In conclusion, we establishes the macro technology road map and the product-related road map for container ports in Korea.

Utilization of EPRI ChemWorks tools for PWR shutdown chemistry evolution modeling

  • Jinsoo Choi;Cho-Rong Kim;Yong-Sang Cho;Hyuk-chul Kwon;Kyu-Min Song
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3543-3548
    • /
    • 2023
  • Shutdown chemistry evolution is performed in nuclear power plants at each refueling outage (RFO) to establish safe conditions to open system and minimize inventory of corrosion products in the reactor coolant system (RCS). After hydrogen peroxide is added to RCS during shutdown chemistry evolution, corrosion products are released and are removed by filters and ion exchange resins in the chemical volume control system (CVCS). Shutdown chemistry evolution including RCS clean-up time to remove released corrosion products impacts the critical path schedule during RFOs. The estimation of clean-up time prior to RFO can provide more reliable actions for RCS clean-up operations and transients to operators during shutdown chemistry. Electric Power Research Institute (EPRI) shutdown calculator (SDC) enables to provide clean-up time by Co-58 peak activity through operational data from nuclear power plants (NPPs). In this study, we have investigated the results of EPRI SDC by shutdown chemistry data of Co-58 activity using NPP data from previous cycles and modeled the estimated clean-up time by EPRI SDC using average Co-58 activity of the NPP. We selected two RFO data from the NPP to evaluate EPRI SDC results using the purification time to reach to 1.3 mCi/cc of Co-58 after hydrogen peroxide addition. Comparing two RFO data, the similar purification time between actual and computed data by EPRI SDC, 0.92 and 1.74 h respectively, was observed with the deviation of 3.7-7.2%. As the modeling the estimated clean-up time, we calculated average Co-58 peak concentration for normal cycles after cycle 10 and applied two-sigma (2σ, 95.4%) for predicted Co-58 peak concentration as upper and lower values compared to the average data. For the verification of modeling, shutdown chemistry data for RFO 17 was used. Predicted RCS clean-up time with lower and upper values was between 21.05 and 27.58 h, and clean-up time for RFO 17 was 24.75 h, within the predicted time band. Therefore, our calculated modeling band was validated. This approach can be identified that the advantage of the modeling for clean-up time with SDC is that the primary prediction of shutdown chemistry plans can be performed more reliably during shutdown chemistry. This research can contribute to improving the efficiency and safety of shutdown chemistry evolution in nuclear power plants.

Experimental Study on Ventilation Efficiency of Leakage Gas Based on Supply and Exhaust Vent Location (밀폐공간에서 급·배기구 위치에 따른 누출 가스의 환기효과에 관한 실험적 연구)

  • Ha-Young Kim;Seong-Min Lee;Byeol Kim;Kwang-Il Hwang
    • Journal of Navigation and Port Research
    • /
    • v.48 no.4
    • /
    • pp.274-283
    • /
    • 2024
  • Climate change is currently one of the most pressing environmental issues, primarily caused by carbon emissions from fossil fuel usage. As a result, alternative fuels that effectively reduce carbon emissions are garnering more attention. Among these alternatives, hydrogen has numerous advantages, such as its ability for large-scale storage and transport. However, it is crucial to prioritize safety measures, particularly in facilities that handle hydrogen, due to its highly flammable and fast-spreading nature. This study aims to compare and analyze the placement of supply and exhaust vents to efficiently release hydrogen in the event of a leak in an enclosed space. The experiments involved six different scenarios, each with various combinations of supply and exhaust vents. To ensure the experimental process's safety, helium, which shares similar physical properties with hydrogen, was used to analyze the internal oxygen concentration during ventilation system operations. The results revealed that among the six scenarios, Case 2, which employed a lower side supply vent and an upper side exhaust vent, exhibited the shortest ventilation time of 4 minutes and 30 seconds. Additionally, the decrease rate in oxygen concentration was examined in the upper, middle, and lower areas. Ventilation utilizing an upper surface supply vent and two exhaust vents on the upper surface and upper side (Case 6), showed lower oxygen concentration values in the upper area, while Case 2 yielded lower values in the middle and lower areas. Therefore, it is crucial to select an appropriate supply and exhaust vent configuration considering the space's characteristics and usage environment.

An Enhanced Colorwave Reader Anti-collision Algorithm in RFID System (RFID 시스템에서의 Enhanced Colorwave 리더 충돌 방지 알고리즘)

  • Lee Su-Ryun;Lee Chae-Woo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.2 s.344
    • /
    • pp.27-38
    • /
    • 2006
  • When an RFID reader attempts to read tags, interference might occur if the neighboring readers also attempt to communicate with the same tag at the same time or the neighboring readers use the same frequency at the same time. These interferences cause the RFID reader collision. When the RFID reader collision occirs, either the command from the reader can not be transmitted to the tags or the response from the tags can not be received by the reader correctly. RFID reader anti-collision algorithms have been developed to reduce it. One of the best blown reader anti-collision algorithms is the Colorwave algorithm proposed by MIT. The Colorwave algorithm reduces the reader collisions by having the readers operate at different times. In Colorwave the time is divided into frames and a frame is divided into a number of slots. Each reader can access the tags using the slot time assigned to it. Depending on the probability of the interference, the colorwave adjusts the frame size to improve the efficiency. In this paper, we analyze the operations and the performance of the Colorwave algorithm and identify the problems of the algorithm. We also show that by adding some modifications to the algorithm the performance can be improved significantly.

A Case Study on Chlorine Dioxide Usage at a Conventional Water Treatment Plant (기존 정수장 이산화염소 시범도입 사례연구)

  • Lee, Song-Hee;Lee, Byung-Doo;Kim, Jin-Keun;Seog, Kwon-Soo;Lee, Joung-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.115-119
    • /
    • 2005
  • As the regulations on DBPs are tightened, many water treatment plants (WTPs) in Korea have already introduced or will introduce enhanced coagulation, alternative disinfectants and advanced treatments such as ozonization and granular activated carbon to improve drinking water qualify. After a phenol leakage accident at the Nakdong-River in 1991, 26 WIPs in Korea introduced carbon dioxide generators, but there has been no accumulation of significant operating data. This research summarizes things that should be considered for the introduction of carbon dioxide disinfection process to WTPs based on one year operation data from A WTP that has had high concentration of DBP during a specific period in the summer. The removal efficiency of DBP was $30{\sim}40%$, but those of 2-MIB, Geosmin were less than 10%. The generation rate of $ClO_2$ by-products such as chlorite and chlorate were $70{\sim}100%$ of input dosage, but the ratios increased over time. At the same time, strong chlorine odors may be produced in the distribution system when $ClO_2$ was used with $Cl_2$ as a result of reaction between the chlorite and residual chlorine.

Design of Illumination Control System Using Microwave Sensors and Dimming Control (마이크로웨이브센서와 디밍제어를 활용한 조명제어시스템 설계 및 구현)

  • Song, Eun-Seong;Min, Byoung-Won;Oh, Yong-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.19-26
    • /
    • 2013
  • In this paper, we present a novel illumination system for parking lots constructed underground. We design and implement this system using microwave sensors and dimming control of LED fluorescent lamps so that we can obtain lighting efficiency of the illumination scheme. We construct an effective illumination system in the aspects of performance and cost, resulting in energy-saving and electricity reduction. Recently conventional energy-saving method applied to old underground parking lots mainly relies upon turning off the half of total number of lamps installed in the parking lot. Sometimes there are some lots that have infrared sensor to be used to turn on/off the fluorescent lamps to realize these operations smoothing. The other schemes utilize timer to control lighting time of the fluorescent lamps. These conventional schemes are forcing to turn off a part of lamps installed so that we cannot apply them in a systematic way. Moreover they will be most inefficient when we leave them alone to be continuous consumers. The lighting control system proposed in this paper can recognize objects through microwave sensors and inform the appropriate lighting time, furthermore we can adjust brightness of LED lamps following the surroundings using dimming control scheme so that we can epochally improve the illumination system for underground parking lots. According to our sophisticated test experiments, we can maximally obtain 81.9% of energy-saving effectiveness using the system proposed in this paper.

A Study of an Association Admission Method for Public Wireless LAN Systems (고속 공중 무선랜 시스템을 위한 효율적인 연결 수락 제어방법의 연구)

  • Lee, Hyun-Woo;Yoon, Hong;Yoon, Chong-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.7 no.2
    • /
    • pp.149-155
    • /
    • 2003
  • This paper generally relates to the field of wireless local area networks(WLANs), and more particularly, to AP selection and association methods for the performance of a station. In these days, IEEE 802.11 Wireless LAN network is widely deployed and used as an emerging service to connect high-speed Internet in the public wireless environment. But, if there are many users in hot spot area, they suffer a severe decrease of performance. Thus it needs an association and access control mechanism especially when it is used in the public environment. In this paper, we suggest a selection and association method using Beacon or Probe Response frames based IEEE 802.11. Station selects AP using the information of the capacity area in a Beacon or a Probe Response frame. According to the present paper, an association method for a public WLAN service, which includes a WLAN user terminal and an AP for relaying WLAN communications to and from the user terminal, includes the steps of the user terminal asking the AP's states for access to a radio channel; and the station selects and associates with the AP. According to the above-described selection in a high speed wireless Internet service based on public WLAN technologies that are currently in operations. Further, it is possible to improve the efficiency of network management.

  • PDF