• 제목/요약/키워드: Education Buildings

검색결과 307건 처리시간 0.027초

명치기(明治期) 일본(日本) 소학교건축(小學校建築)의 표준화 과정 및 특성에 관한 연구 - 문부성 제정 표준도 분석을 중심으로 - (A Study on the Change and Characteristics of Stereotyped Japanese Elementary School in Meiji Era - Focusing on the Standard Drawings by Japanese Ministry of Education -)

  • 이정우;심우갑
    • 교육시설
    • /
    • 제15권2호
    • /
    • pp.27-38
    • /
    • 2008
  • This study aims to examine Japanese elementary school architecture in Meiji Era, in which Japanese modern education system was settled down and the school architecture flourished by mass construction of stereotyped school buildings. It is assumed that stereotyped school architecture is due to the influence of the standard drawings made by Japanese Ministry of Education, therefore standard drawings could be a key to understand the characteristics of the stereotyped school buildings in Meiji Era. In this perspective this study attempts to analyze 4 standard drawings and interpret it in relation to regulations and design guidelines for school architecture in that time. As results of this study the change and characteristics of stereotyped school architecture in Meiji Era are clarified in several categories. They are as follows : the deviation of classroom and corridor, the change of classroom size fixing to 4 kan(間) by 5 kan(間), the absolute use of north-lacing single corridor type block-plan, and the change of other space such as waiting room(控所), special instruction room, auditorium and gymnasium.

국내 학교시설 천장재의 내진성능 분석 (Analysis on the Seismic Performance of Ceiling System in School Buildings)

  • 박성철;조진일;정태환
    • 교육녹색환경연구
    • /
    • 제15권1호
    • /
    • pp.11-18
    • /
    • 2016
  • 본 연구는 학교현장의 안전교육 과정에서 학교시설 비구조재 중 위험도가 상대적으로 높은 천장재의 내진성능을 평가하고 대책방안을 제시하는 것이다. 평가도구의 개발을 위하여 본 연구는 다음과 같은 4단계로 진행되었다. 첫 단계에서는 국내 외의 내진성능평가 가이드라인들을 분석하여 주요 천장재의 구성품목과 각 품목별 평가방법들을 조사하고, 두 번째 단계에서는 문헌조사의 결과를 기반으로 주요 품목들의 내진성능 실태를 면밀하게 조사하였다. 세 번째 단계에서는 조사된 천장재 구조를 정량적으로 평가하여 지반 및 지진의 유형에 따른 적정성을 평가하였다. 마지막으로 국내 학교시설 천장재에서 우선적으로 고려되어야 할 내진성능보강 대책방안을 제시하였다.

Contribution of non-structural brick walls distributions on structures seismic responses

  • Farghaly, Ahmed Abdelraheem;Rahim, Hamdy H.A. Abdel
    • Earthquakes and Structures
    • /
    • 제5권5호
    • /
    • pp.553-570
    • /
    • 2013
  • Using of masonry infill as partitions, in flat slab frame buildings is a common practice in many parts of the world. The infill is, generally, not considered in the design and the buildings are designed as bare frames. More of fundamental information in the effect of masomary infill on the seismic performance of RC building frames is in great demand for structural engineers. Therefore the main aim of this research is to evaluate the seismic performance of such buildings without (bare frame) and with various systems of the masonary infill. For this purpose, thirteen three dimensional models are chosen and analyzed by SAP2000 program. In this study the stress strain relation model proposed by Crisafulli for the hysteric behaviour of masonary subjected to cyclic loading is used. The results show that the nonstructural masonary infill can impart significant increase global strength and stiffness of such building frames and can enhance the seismic behaviour of flat slab frame building to large extent depending on infill wall system. As a result great deal of insight has been obtained on seismic response of such flat slab buildings which enable the structural engineer to determine the optimum position of infill wall between the columns.

대한제국기 근대적 측량의 도입과 측량도면의 성격 (The Development of Modern Survey and the Characteristics of Survey Drawings in Early Modern Korea)

  • 이규철
    • 건축역사연구
    • /
    • 제19권6호
    • /
    • pp.187-208
    • /
    • 2010
  • The purpose of this study is to understand the transition process of Korean architecture and urbanism from traditional state to modern state, by investigating the development of modern survey and the characteristics of survey drawings during the Great Han Empire (大韓帝國), the early modern Korea. The governmental efforts of the Great Han Empire to introduce a modern survey system named Gwangmu Land survey (光武量田事業) ended in failure. After the Russo-Japanese War (露日戰爭, 1904-1905), the Residency-General (統監府) held the hegemony of Korean Peninsula. It reintroduced a modern survey system for the survey of land and buildings all over the country and enforced the Land and Buildings Certification System (土地家屋證明制度). Since then, the land and buildings survey was propagated rapidly and the modern system for land use was gradually organized. With the progress of modern survey, the survey bureau of Cabinet (內閣) and Department of Royal Household (宮內府) created survey drawings that had some characteristics of colonialism. Takjibu (度支部) produced cadastral maps of major cities, with which the modern land system was developed. In addition, the Royal Property Bureau (帝室財産整理局) produced survey drawings of land and buildings owned by the Royal Household which were finally converted into modern facilities.

학교 건축에 대한 BIPV시스템의 성능 평가 (Performance Evaluation of BIPV Systems Applied in School Buildings)

  • 박경은;김진희;김준태
    • 교육시설
    • /
    • 제11권5호
    • /
    • pp.14-23
    • /
    • 2004
  • Building-integrated photovoltaic(BIPV) systems can operate as a multi-functional building components, which generates electricity and serves as part of building envelope. It can be regarded as a new architectural elements, adding to the building's aesthetics. Besides of these benefits, the application of PV systems into school buildings tends to play an important role in energy education to students. In this context, this study aims to analyse the applicability of PV systems into school buildings. For an existing school building, four types of BIPV designs were developed; rooftops, wall-attached, wall-mounted with angle, and sunshading device. Based on energy modeling of those BIPV systems, the whole 60.1kWp rated PV installation is expected to yield about 65.6MWh of electricity, that is about 50% more than the annual electricity consumption of the school, 44MWh. It was also found that the applicability of the PV systems into the school building was very high, and the rooftop systems with the optimized angle was the most efficient in energy production, followed by sunshading, wall-mounted with angle and wall-attached. It concludes that school buildings have a reasonable potential to apply PV systems in the aspects of building elements and electricity production.

교육 시설기준 변화에 따른 학교건축물의 에너지원 변화에 관한 연구 (A study on the Energy resource in School Buildings with the Changes of Educational Facilities Standard)

  • 김태우;이강국;홍원화
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.73-80
    • /
    • 2010
  • Since the Korean War, Korea has experienced modernization. The population increase by baby booming has asked for more space for educational facilities. In such a situation, the purpose of educational facilities was to accommodate continuously increasing students, rather than seeking for quantitative demands. In addition, in accordance with social changes, educational shifts were required. After the revision of the seventh national curriculum in education in 1997, the school buildings became varied. The design of buildings in accordance with educational curriculum has been improved, but still lack of forming comfortable environment and considering energy efficiency in school buildings. For the improvement of educational environments, educational media such as TV and computers have been provided, and energy systems, including heating and cooling systems, has been continuously increased. As a result, it appeared that energy use in school buildings and facilities has been steadily increased and that the structure of energy consumption has been also changed, especially with regard to electricity use. Living in the 21st century, human beings face global environmental issues, such as global warming, geographical climate changes, and ozone destruction that are the consequences of fossil energy use. Therefore, even in industrial areas, considering a counterplan for low energy use is being paid attention. Starting with Kyoto Protocol in 1992, people try to decrease carbon dioxide and to develop alternative energies (i.e. natural energy); for example, solar energy, wind force, terrestrial heat, and water power. Advanced countries already set up a criterion for $CO_2$ decrease ranging from office buildings to residential houses and also propose alternatives for the $CO_2$ decrease. However, there is no such a plan for low energy use and $CO_2$ decrease in school facilities, and any research on the actual conditions was not accomplished. Thus, this study examines energy demand in classrooms that take up a large portion of energy demand in school building structure.

경기도의 옥상녹화 가용면적 추정과 이의 정책적 함의 (Estimation of the Potential Area for Roof Greening in Gyeonggi-do and Its Implications)

  • 박은진;남미아;강규이
    • 한국환경복원기술학회지
    • /
    • 제15권1호
    • /
    • pp.107-117
    • /
    • 2012
  • We estimated the potential area roof greening in Gyeonggi-do that will mitigate the heat island effect. The estimation was based on building age, roof shape, and building use which were recorded in the building register from "Sewoomteo, the Building Administration System in the Ministry of Land, Transport and Maritime Affairs. The estimated potential roof greening area in Gyeonggi-do was approximately $102.5km^2$ assuming that the buildings for residence, public, education(school), office, shopping mall are appropriate for roof greening. The area occupied by apartment buildings over six-story was 76.3% of the potential roof greening area 10.2% for individual houses, 5.9% for under five-story apartment buildings, and 3.7% for school buildings. The result indicated that it is residential buildings that we need to pay attention for roof greening, especially high-rise buildings over six-story. Greening of the whole estimated area, $102.5km^2$, in Gyeonggi-do will result in the increase of green space per capita by $8.74m^2$. This is 1.65 times greater than the area of current urban parks, and 1.97 times greater than the total area of neighborhood parks, children's parks, and pocket parks. Greening of the estimated roof area will increase green coverage of urban area by twice, adding to current green coverage of the urban areas, 11.3%, in 10 major cities. In particular, the effect of roof greening would be remarkable in inceasing the green space of Anyang City, Gwangmyeong City, and Guri City where neighborhood park area falls short.

리모델링시 학교시설의 친환경건축물 인증요소 비교분석 연구 (A Study on the Comparative Analysis of the Green Building Certification Criteria for Schools in remodeling)

  • 양원석;주범
    • 한국실내디자인학회논문집
    • /
    • 제20권1호
    • /
    • pp.182-189
    • /
    • 2011
  • This study is purposed on applying to certifying environmental-friendly buildings about remodeling schools as an issue recently, keeping up a worldwide resource conservation movement. Application standard is directed, comparing with systems certifying green-schools in domestic and foreign policies. The following is the primary result of this study. First, on developing systems for certifying environmental-friendly buildings about remodeling schools, characteristics like ‘the phase of certifying essential lists and the diversity of certifying lists’, ‘developing departmentally into new-building, reconstruction, remodeling, existing-building in basic data’, ‘development of certifying existing-buildings as well as new-building’ in foreign systems should be developed appropriately for Korea. Next, not only reuse of the existing facilities but better assessment through diversification of classified contents in domestic system are carried out in comparing remodeling lists. Especially the primary list that is found out commonly limited lists certifying remodeling should be developed appropriately. Impossible lists getting certification should be applied to map out a concrete standard. Lastly, the range of certification should be diversified and developed sustainable like other systems for better assessment. Adding various lists suiting for Korea and departmentalizing score of phases and items in particular, for avoiding a needless collision between certification lists, absence of them. Above of all, basic direction about certifying environmental-friendly buildings about remodeling schools should be developed the only individual instrument, not for gaining it simply as a part of the environmental policy in Korea. This study has significance on vitalization of certifying environmental-friendly buildings, which performing primary environmental-friendly education facilities, based on its advance.

Design review on indoor environment of museum buildings in hot-humid tropical climate

  • Ogwu, Ikechukwu;Long, Zhilin;Okonkwo, Moses M.;Zhang, Xuhui;Lee, Deuckhang;Zhang, Wei
    • Advances in Computational Design
    • /
    • 제7권4호
    • /
    • pp.321-343
    • /
    • 2022
  • Museum buildings display artefacts for public education and enjoyment, ensuring their long-term safety and the comfort of visitors by following strict indoor environment control protocols using mechanical Heating, Ventilation and Air Conditioning (HVAC) systems to keep the (environmental) variables at a fixed comfort level. Maintaining this requires constant supply of energy currently mostly sourced from the combustion of fossil fuels which exacerbates climate change. However, a review on the effects of the indoor environmental variables on museum artefacts as well as museum visitors revealed that there is no specific point at which artefact deterioration occurs, and that there are wide ranges of conditions that guarantee the long-term safety of artefacts and human comfort. Visits to museum buildings in hot-humid tropical climate of Nigeria revealed that strict indoor environmental practices were adopted. Even when appropriate micro-climatic conditions are provided for artefacts, mechanical HVAC systems remain necessary for visitor comfort because almost no consideration is given to natural ventilation. With the current global push towards energy management, this paper reviewed passive environmental control practices, architectural design strategies, and discusses the adaptation of double skin façade with jali screens, and the notion of smart materials, which can satisfy the range of requirements for the long-term safety of artefacts and levels of human comfort in buildings in hot-humid tropical climate, without mechanical HVAC systems. This review would inspire more discussions on passive, energy efficient, smart and climate responsible popular architecture, challenging current thinking on the impact of the more accepted representative architecture.

한국의 제로에너지건축 정책 추진에 따른 건축물 에너지기술 성능 연구 (A Study on the Performance Increase in Building Energy Technology according to the Korea's Zero Energy Building Policy)

  • 심홍석;이성주
    • 한국산학기술학회논문지
    • /
    • 제22권5호
    • /
    • pp.543-553
    • /
    • 2021
  • 한국은 건물부문 온실가스 감축 목표 달성을 위한 핵심정책으로 2020년부터 공공부문 신축 건축물을 대상으로 제로에너지건축물 인증 의무화를 시행하였다. 이 논문은 궁극적인 Net Zero 에너지건축물 달성하는 데 있어서 정부의 정책에 따른 건축물 에너지성능의 변화 추세를 파악하고, 최근 건축물에 적용된 에너지기술 성능의 변화 추이를 분석하는 방법론을 제시함으로써 궁극적으로는 장기적인 Net Zero를 달성하고자 하는 정책 환경의 변화에서 건축 관련 이해 관계자들이 건축물 유형별로 적절한 에너지기술들을 적용하는데 도움을 주고자 한다. 본 연구를 위해 최근 4년간 건축물 에너지효율등급 예비인증 데이터를 수집하여 건축물의 에너지성능이 상승하는 추세를 확인하였다. 또한, 최근 건축물에 적용된 에너지기술들의 에너지성능 현황을 분석하기 위하여 K-means 군집분석 활용해 교육연구 시설과 업무시설의 High, Low 에너지성능 군집을 통해 비교군(2016년~2020년, 2020년) 설정하여, 분석하였다. 분석 결과 교육연구 시설의 High, Low 군집 모두 태양광 모듈 면적의 증가율이 261.1%, 283.5% 급증하였으며, 업무시설은 High, Low 군집 모두 태양광 모듈 면적이 감소하는 반면에 대부분의 패시브, 액티브 기술의 에너지성능이 증가하는 것으로 분석되었다.