Analysis of Water Flux Uniformity for Various Fire Sprinkler Head Type (화재 진압용 스프링클러 헤드 유형에 따른 살수 균일도 분석)

  • Saemi Bang;Chanseob Ahn;Taehoon Kim
    • Journal of ILASS-Korea
    • /
    • v.28 no.2
    • /
    • pp.97-104
    • /
    • 2023
  • A sprinkler is a fire suppression system that extinguishes combustible materials in the early stages of a fire, creating a spray. However, spray formation method of the sprinkler can result in an uneven distribution of water spray on the surface of combustible materials. It is necessary to ensure a consistent water flux density regardless of the spray direction and angle. In this study, the water flux distribution was analyzed for the various types of sprinkler head: circular, flush, pendent, and upright types. All sprinkler heads have a K-factor of 80 LPM/(0.1MPa)0.5. In this study, water collection cubes were used to examine the water flux distribution. The upright type sprinkler head showed a low standard deviation in total sprayed area, indicating a high level of uniformity. The upright type head showed the lowest standard deviation in the radial direction, and also showed the lowest standard deviation in the azimuthal direction. Upright sprinkler head has no obstructing structure along the path of droplets after they are generated. For this reason, upright sprinkler head showed the most uniform water flux distribution on the floor.

Fire Suppression Test using the Automatic Monitor System for Double-Deck Tunnel (복층터널 자동 모니터 소화설비를 이용한 화재진압 실험)

  • Park, Jin-Ouk;Yoo, Yong-Ho;Kim, Hwi-Seung;Park, Byoung-Jik;Kim, Yang-Kyun
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.40-46
    • /
    • 2017
  • As one of the solutions to deal with economic loss caused by traffic congestion in metropolitan area, a deep underground road has been planned and implemented at home and abroad. The part of them has been pushed ahead with a double-deck scheme which has an advantage in constructability and cost efficiency comparing to traditional road tunnel. However, the double-deck tunnel has a lower floor height than the general road tunnel due to the special structure used as the upper and lower lines by installing the middle slab on one excavation section. Therefore, it is relatively weak against fire accidents and ventilation problems occurring in tunnels. Thus study to develop the life safety system optimized to a double-deck tunnel has been systematically carried out in order to overcome their weak point. In this study, automatic monitoring fire extinguisher (AMFE) is developed to suppress a fire and prevent its spread at early stage of tunnel fire, conducting the performance test through vehicle fire tests as verification. The tests were conducted with AMFE being 30 m apart from the vehicle and 10 m apart from engine room. As a results, it was confirmed that AMFE enables to suppress a fire and prevent its spread in both cases.

Methods to Improve the Design of Household Fire Extinguishers through an Empirical Analysis of Consumer Compatibility (소비자의 적합성 실증분석을 통한 가정용 소화기의 디자인 개선방안)

  • Lee, Sung-Woo
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.58-66
    • /
    • 2020
  • Households are categorized as exceptions in the Fire Services Act; oftentimes, the 'Golden Time' is missed at the early stages of a fire, resulting in loss of life. As such, due to the high number of deaths caused by household fires, the Korean government amended the Fire Services Act to make it mandatory for all detached houses to be equipped with a fire extinguisher from 2017 onwards. Only 34.8% of households were properly equipped with a fire extinguisher, according to the 2018 factual survey on fire extinguishing facilities in households conducted by the Fire Department. Fire extinguishers are crucial in case of fire but many households avoid them because they are red and have a rough aesthetic, which does not suit the household environment. There is now a need for diverse simple fire extinguisher designs so that they can be used as interior décor in the household in the day-to-day while being available for putting out a fire when necessary. If fire extinguishers have designs that go well with any household space like other decorative ornaments, this will greatly increase consumers' motivation to purchase them. It is greatly anticipated that various companies will work on developing designs for fire extinguishers to commercialize them for households in the future.

An Improvement of Fire Safety Code for Rack-Type Warehouse in Korea (국내 랙크식 창고의 방화관련 규정 개선에 관한 연구)

  • Kim, Woon-Hyung;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.69-75
    • /
    • 2014
  • Recently Amore pacific rack-type warehouse fire broke out and argue an urgent improvement of fire protection design code including automatic sprinkler and detection design. Various type of commodities have their unique fire characteristics from fire spread rate and heat lease rate and fire hazard depends on storage height, rack arrangement, aisle width, fire load etc. With increasing ceiling height for more storage space prevent effective water spray of sprinkler head, also delays detection time causes failure of early suppression. To achieve fire protection code performance of this occupancy, Major code articles relating to a classification of commodity, sprinkler system installation, detection and fire fighting are reviewed and suggested based on fire case analysis, code review between country and field survey.

A Study about Research on the Actual Condition for Fire Counterplan of Main Temple Wooden Cultural Properties (중요사찰목조문화재의 소방대책을 고려한 실태조사에 관한 연구)

  • Back, Min-Ho;Shin, Ho-Jun
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.121-130
    • /
    • 2009
  • This study is researched about the field trip of temples and the data for fire extinguishment manual of fire stations: it is done from June 2008 to December 2008 the 80 main temple wooden cultural properties among the 124 main wooden cultural properties appointed by the Cultural Heritage Administration. Cultural properties appointment classification, location classification, temple area, building area in a temple, building area of appointment cultural properties, a fire engine drive direction for fire suppression in a fire, distance from a fire station, and present condition of a fire administrator are researched. The cultural properties possess characteristic is in 2 cases: the whole things in a temple are appointed as cultural properties and only the wooden building is. The cultural properties are classified: the transport is possible or not. The special quality of cultural properties are classified for early correspondence and cultural properties transport in a fire and the basic data are arranged for damage limitation.

An Experimental Study on Characteristics of Sprinkler Head Activation in Low Growth Rate Fire (저성장속도 화재에서의 스프링클러 헤드 동작특성에 관한 실험적 연구)

  • Choi, Yong-Seob;Yoon, Jong-Chil
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.26-35
    • /
    • 2016
  • Sprinkler installations shall be operated at normal operating temperature of the atmosphere as a fire sprinkler head in any facility to control and extinguish the fire when the fire initially. Recently, however, some flush type quick response automatic sprinkler heads in slow fire place is a problem that can not be normal operation are raised. In this paper, by using the experimental model of the Apartment house of Commons and Cabinet burner size bedrooms fire conditions to form a slow growth rate and can supply more than 0.2 MPa pressure is the minimum pressure that can be applied inside the pipe in the field experiment was conducted. In the majority of experiments lush type quick response automatic sprinkler heads which is used in the country it was confirmed to be incompletely opened as the Cold Soldering occur. This phenomenon is likely to fail early fire suppression and control because they can cause the spread of fire and casualties needed to complement domestic product testing and type approval standards through additional research.

Development of Independent Sprinkler for Fire Safety (소방안전을 위한 독립 스프링클러 개발)

  • Yun, Hae-Yong;Kim, Seon-Yeop;Kim, Ho-Chan;Park, In-Beck
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.124-128
    • /
    • 2017
  • Sprinklers are a necessary device for the early suppression of fires to prevent large fires. The installation has been obligatory for certain buildings recently through the digestion method. In an aging building, it is difficult to find sprinklers, because of their significant cost, long installation times, and they require installation by experts. That is why we are able to install all, was designed with enough independent integrated sprinklers with fire-extinguishing capabilities. The designed sprinklers are fitted with a conventional sprinkler head in a container of 20cm * 20cm * 10cm. Inside the container and potassium carbonate, which warms the rubber material and the plate line by pressing the potassium carbonate, the line weight is a 5kg pressing plate at the entrance at the pressure of 0.5Mpa when operating. The glass sprinkler valve blocking the entrance at about $68^{\circ}C$ is operated open. At this time, the potassium out of the digestive fire to combustible materials and heat off a chain reaction.

Study on the Disaster Prevention System for Wooden Cultural Assets Using USN -Focusing on the System Checking the Malfunction of Flame Detector- (USN을 이용한 목조문화재 방재시스템에 관한 연구 -불꽃감지기 오작동 확인시스템을 중심으로-)

  • Back, Min-Ho;Kim, Jeong-Ho
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.49-54
    • /
    • 2010
  • The wooden cultural assets have the characteristics such as the fast spread of flame and leading to total destruction. Therefore, there is a need for a system for early countermeasure of recognized problem, along with the technological response for accurately recognizing the situation, for the prevention and early suppression of fire. To utilize such technology for detecting the situation through the latest ubiquitous technology and for a quick response to suppress fire, the ubiquitous sensor network (USN) technology, flame detector, image sensor, USN-based cultural asset disaster prevention management application case and malfunction identification system realization were examined in this study and the study result was presented focusing on the flame detector malfunction identification system for the ubiquitous-type cultural asset disaster prevention system.

He Study of Fire Suppression Capability of Low Pressure Water-Mist System for Wooden Cultural Properties (목조한옥에 대한 저압식 미분무 소화설비의 소화성능에 관한 연구)

  • Roh, Sam-Kew;Kim, Dong-Cheol;Ham Eun-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.401-410
    • /
    • 2012
  • The study verified the extinguishing performance of the low pressure water-mist system, which is used to extinguish fire at domestic wooden architecture, through a fire test. Made of inflammable materials, a wooden house is vulnerable to fire, and the size of fire may vary from the early stage in case of arson. With the discharging pressure of 8 bar and the flow rate of 35 lpm, the low pressure water-mist nozzle used in the experiment has considerable discharging amount compared to other water-mist nozzles. The extinguishing performance was tested based on the size of fire and architecture. Test results demonstrated that the extinguishing performance was not affected by the size of a house, but decreased significantly when the size of fire was above unit 1. Taking into account that the environment of actual wooden cultural properties is more vulnerable than that of the experiment model, sufficient investigation on extinguishing performance is required to apply the water-mist extinguishing system to wooden architecture.

Development of Forest Fire Occurrence Probability Model Using Logistic Regression (로지스틱 회귀모형을 이용한 산불발생확률모형 개발)

  • Lee, Byungdoo;Ryu, Gyesun;Kim, Seonyoung;Kim, Kyongha
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • To achieve the forest fire management goals such as early detection and quick suppression, fire resources should be allocated at high probability area where forest fires occur. The objective of this study was to develop and validate models to estimate spatially distributed probabilities of occurrence of forest fire. The models were builded by exploring relationships between fire ignition location and forest, terrain and anthropogenic factors using logistic regression. Distance to forest, cemetery, fire history, forest type, elevation, slope were chosen as the significant factors to the model. The model constructed had a good fit and classification accuracy of the model was 63%. This model and map can support the allocation optimization of forest fire resources and increase effectiveness in fire prevention and planning.