EFFECT OF THE EXPONENTIAL CURING OF COMPOSITE RESIN ON THE MICROTENSILE DENTIN BOND STRENGTH OF ADHESIVES (복합레진의 exponential 중합법이 상아질접착제의 미세인장접착강도에 미치는 영향)

  • Seong, So-Rae;Seo, Duck-kyu;Lee, In-Bog;Son, Ho-Hyun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.125-133
    • /
    • 2010
  • Objectives: Rapid polymerization of overlying composite resin causes high polymerization shrinkage stress at the adhesive layer. In order to alleviate the shrinkage stress, increasing the light intensity over the first 5 seconds was suggested as an exponential curing mode by an LED light curing unit (Elipar FreeLight2, 3M ESPE). In this study, the effectiveness of the exponential curing mode on reducing stress was evaluated with measuring microtensile bond strength of three adhesives after the overlying composite resin was polymerized with either continuous or exponential curing mode. Methods: Scotchbond Multipurpose Plus (MP, 3M ESPE), Single Bond 2 (SB, 3M ESPE), and Adper Prompt (AP, 3M ESPE) were applied onto the flat occlusal dentin of extracted human molar. The overlying hybrid composite (Denfil, Vericom, Korea) was cured under one of two exposing modes of the curing unit. At 48h from bonding, microtensile bond strength was measured at a crosshead speed of 1.0 mm/min. The fractured surfaces were observed under FE-SEM. Results: There was no statistically significant difference in the microtensile bond strengths of each adhesive between curing methods (Two-way ANOVA, p > 0.05). The microtensile bond strengths of MP and SB were significantly higher than that of AP (p < 0.05). Mixed failures were observed in most of the fractured surfaces, and differences in the failure mode were not observed among groups. Conclusion: The exponential curing method had no beneficial effect on the microtensile dentin bond strengths of three adhesives compared to continuous curing method.

Influence of airborne-particle abrasion on flexural strength of fiber-reinforced composite post (미세입자 분사마모 표면처리가 Fiber-Reinforced Composite 포스트의 굴곡 강도에 미치는 영향)

  • Sim, Eun-Ju;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.24-31
    • /
    • 2016
  • Purpose: Many studies have shown that airborne-particle abrasion of fiber post can improve the bonding strength to resin cement. But, airborne-particle abrasion may influence the property of fiber post. The purpose of this study is to evaluate the influence of airborne-particle abrasion on flexural strength of fiber post. Materials and Methods: Two fiber-reinforced posts; DT Light Post Size 2 (1.8 mm diameter, Bisco Inc) and RelyX Fiber Post Size 3 (1.9 mm diameter, 3M ESPE); were used in this study. Each group was divided into 3 subgroups according to different surface treatments; without pretreatment: $50{\mu}m$ aluminum oxide (Cobra$^{(R)}$, Renfert): and $30{\mu}m$ aluminum oxide modified with silica (Rocatec Soft$^{(R)}$, 3M ESPE). After airborne-particle abrasion procedure, three-point bending test was done to determine the flexural strength and flexural modulus. The diameter of each posts was measured to an accuracy of 0.01 mm using a digital micrometer. There was no diameter change before and after airborneparticle abrasion. The mean flexural moduli and flexural strengths calculated using the appropriate equations. The results were statistically analyzed using One-way ANOVA and Scheffe's post-hoc test at 95% confidencial level. Results: There was no significant difference on flexural strength between groups. Conclusion: In the limitation of this study, flexural strength and flexural modulus of fiber post are not affected by airborne-particle abrasion.

The influence of surface conditioning on the shear bond strength of self-adhesive resin cement to zirconia ceramics (표면처리방법이 지르코니아와 수종의 시멘트의 전단결합강도에 미치는 영향)

  • Jung, Ji-Hye;Jung, Seung-Hyun;Cho, Hye-Won;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.251-258
    • /
    • 2010
  • Purpose: To evaluate the effect of surface conditioning on the shear bond strength of zirconium-oxide ceramic to 4 luting agents. Materials and methods: A total of 120 diskshaped zirconium-oxide ceramic blocks (3Y-TZP, Kyoritsu, Japan) were treated as follows: (1) Sandblasting with $110\;{\mu}m$ aluminum-oxide ($Al_2O_3$) particles; (2) tribochemical silica coating (Rocatec) using $110\;{\mu}m$ $Al_2O_3$ particles modified by silica; (3) no treatment. Then zirconium-oxide ceramic blocks bonded with 4 luting cements (RelyX luting (3M ESPE), Maxcem (Kerr), Nexus3 (Kerr), Rely X Unicem (3M ESPE)). Each group was tested in shear bond strengths by UTM. A 1-way analysis of variance and 2-way analysis of variance was used to analyze the data ($\alpha$ = .05). Results: RelyX unicem in combination tribochemical silica-coating produced a highest bond strength (P < .05). Air abrasion group and Rocatec treatment groups resulted in significantly higher than no conditioning group (P < .05). RelyX Luting groups showed lower bond strength than other groups. There were significant differences among groups (P < .05). Conclusion: Within the limitation of this study, RelyX Unicem cement provided the highest bond strength and Rocatec treatment enhanced the bond strength.

Effect of Conditioning Methods on the Shear Bond Strength of Veneering composite on Zirconia Ceramic (Y-TZP ceramic의 표면처리에 따른 전장용 레진의 전단결합강도)

  • Nam, Hyun-Seok;Song, Kwang-Yeob;Ahn, Seung-Geun;Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.253-264
    • /
    • 2010
  • The purpose of this study is to know whether Yttrium-stabilized-tetragonal -zirconia-polycrystal(Y-TZP ceramic) gets enough shear bond strength for clinical uses by applying veneering composite resin through surface treatment on it and finally to compare it with the case of applying veneering porcelain. LavaTM zirconia frameworks(3M ESPE, Seefeld, Germany) were prepared. Group P was manufactured with LavaTM Ceram(3M ESPE, Seefeld, Germany) in cylindrical shape which has 4mm diameter, 5mm height. Group ZSR disposed sandblasting and applied silane, bonding agent and after that indirect composite resin was applied. Group ZRR got tribochemical coating by RocatecTM system(3M ESPE. Seefeld, Germany) and treated silane. Finally Group ZPR took the same treatment and applied LavaTM Ceram in the size of 0.3-0.5mm height. After burning out, sandblasting, HF and silane was applied. And then, indirect composite resin was applied. 1000 cycle thermocycling was performed in $5-55^{\circ}C$ and shear bond strength was measured. There were no significant differences between combining veneering porcelain to Y-TZP ceramic group and combining veneering resin to Y-TZP ceramic group in the aspect of shear bond strength (p>.05).

EFFECT OF VARIOUS LINERS ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN (수종의 이장재가 복합레진의 중합수축에 미치는 영향)

  • Choi, Ji-Won;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.606-614
    • /
    • 2006
  • The purpose of this study was to evaluate the polymerization contraction of composite resin(Tetric $ceram^{(R)}$, Ivoclar Vivadent Liechtenstein) according to various liners(Tetric $flow^{(R)}$, Ivoclar Vivadent, Liechtenstein/$Ionosit^{(R)}$, DMG, German/ $Vitrebond,^{TM}$ 3M-ESPE, USA). The strain gauge method was used for measurement of polymerization shrinkage strain. Specimens were divided by 8 groups according to curing units and liners. Group A, E: Tetric $ceram^{(R)}$ bulk filing, Group B, F: Tetric $flow^{(R)}$ lining, Tetric $ceram^{(R)}$ filling, Group C, G: $Ionosit^{(R)}$ lining, Tetric $ceram^{(R)}$ filling, Group D, H: $Vitrebond^{TM}$ lining, Tetric $ceram^{(R)}$ filling. Group A, B, C and D were cured using the conventional halogen light($XL3000^{TM}$ 3M ESPE, USA) for 40 seconds at $400mW/cm^2$. Group E, F G and H were cured using light emitted diode(LED) light(Elipar Freelight $2^{TM}$, 3M-ESPE, USA) for 15 seconds at 800 $mW/cm^2$. Strain gauge attached to each sample was connected to a strainmeter. Measurements were recorded at each second for the total of 750 seconds including the periods of light application. Obtained data were analyzed statistically using Repeated measures ANOVA and Tukey test. The results of this were as follows : 1. Contraction stresses in flowable resin and glass ionomer lining group were lower than that in compomer lining group(p<0.05). 2, Contraction stresses in LED curing light groups were higher than that in halogen curing light groups, but there was no significant difference (p>0.05).

  • PDF

A STUDY ON THE FORMATION OF SHEAR BONDING STRENGTH AND HYBRID LAYER ACCORDING TO THE APPLICATION TIME AND FREQUENCY OF AN ALL-IN-ONE SYSTEM IN PRIMARY TEETH. (유치에서 All-In-One system의 적용 시간과 적용 횟수에 따른 전단 결합 강도 및 혼성층 형성에 관한 연구)

  • Hong, Sang-Jin;Park, Jong-Whi;Park, Heon-Dong;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.263-271
    • /
    • 2003
  • The purpose of the present study was to evaluate the patterns of hybrid layer according to the application time and the frequency and its effects on the shear bonding strength of All-In-One system in primary teeth. A single bonding agent(Scotchbond Multi-Purpose Plus, 3M) and an All-In-One system(Prompt L-pop, 3M ESPE) were applied on the dentin varying the application time and the frequency in primary teeth. Shear bond strength was measured and the patterns of hybrid layers were observed by SEM. The following results were obtained ; 1. The shear bonding strength of single bonding agent was significantly higher than that of All-In-One system(P<0.05). 2. The shear bonding strength of All-In-One system applied twice or 3 times were higher than that of applied once (P<0.05). And thickness of the hybrid layer was increased when applied twice or 3 times compared to once. 3. The shear bonding strength of All-In-One system when applied for 15 second and 30 second were higher than that of 7 second (P<0.05). And the hybrid layer thickness of 15 second and 30 second's application time were higher than that of 7 second. 4. Thickness of hybrid layer applied with single bonding agent was $2-4{\mu}m$ and that of All-In-One system was $1-2{\mu}m$.

  • PDF

Effect of Different Surface Treatment on the Shear Bond Strength between Yttria-Tetragonal Zirconia Polycrystal and Non-10-Methacryloyloxydecyl Dihydrogen Phosphate-Containing Resin Cement

  • Lee, Yoon;Yi, Young-Ah;Kim, Sin-Young;Seo, Deog-Gyu
    • Journal of Korean Dental Science
    • /
    • v.7 no.2
    • /
    • pp.49-57
    • /
    • 2014
  • Purpose: To evaluate the effect of different surface treatment methods (yttria-tetragonal zirconia polycrystal [Y-TZP] primers, air-abrasion, and tribochemical surface treatment) on the shear bond strength between (Y-TZP) ceramics and etch-and-rinse non-10-methacryloyloxydecyl dihydrogen phosphate (MDP)-containing resin cements. Materials and Methods: Y-TZP ceramic surfaces were ground flat with 600-grit silicone carbide abrasives paper and then divided into seven groups of ten. They were treated as the following: untreated (control), Monobond Plus (IvoclarVivadent), Z-PRIME Plus (Bisco Inc.), ESPE Sil with CoJet (3M ESPE), air-abrasion, Monobond Plus with air-abrasion, and Z-PRIME Plus with air-abrasion. The surface of Y-TZP specimens was analyzed under a scanning electron microscope (SEM). Non-MDP-containing cements were placed on the surface-treated Y-TZP specimens. After thermocycling, shear bond strength test was performed. Bond strength values were statistically analyzed using one-way analysis of variance and Student-Newman-Keuls multiple comparison test (P<0.05). Result: The Z-PRIME Plus treatment in combination with air-abrasion produced the highest bond strength ($14.94{\pm}1.70MPa$) followed by Monobond Plus combined with air-abrasion ($10.70{\pm}1.71MPa$), air-abrasion ($10.47{\pm}1.60MPa$), ESPE Sil after CoJet treatment ($10.38{\pm}0.87MPa$), Z-PRIME Plus application ($10.00{\pm}1.70MPa$), and then Monobond Plus application ($9.25{\pm}0.86MPa$). The control ($6.70{\pm}1.49MPa$) indicated the lowest results (P<0.05). The SEM results showed different surface morphologies according to surface treatment methods compared with the Y-TZP control. Conclusion: The shear bond strength between the Y-TZP ceramic and the non-MDP-containing resin cement was the greatest when the surface was treated with air-abrasion and MDP-containing Z-PRIME Plus primer.

Effect of water storage on flexural strength of silorane and methacrylate-based composite resins

  • Panahandeh, Narges;Torabzadeh, Hassan;Naderi, Hani;Sheikh-Al-Eslamian, Seyedeh Mahsa
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.309-315
    • /
    • 2017
  • Objectives: This study assessed the effect of water storage on the flexural strength (FS) of low shrinkage composites. Materials and Methods: A total of 165 bar-shaped specimens ($2{\times}2{\times}25mm$) were fabricated of 2 low shrinkage composites (Filtek P90 [3M ESPE], GC Kalore [GC International]) and a conventional methacrylate-based composite (Filtek Z250 [3M ESPE]). The specimens were subjected to 3-point bending test at 6 time intervals, namely: immediately after curing, at 24 hours, 1 week, 1 month, 6 months, and 1 year following storage in wet and dry conditions. The FS of the specimens were measured by applying compressive load at a crosshead speed of 1.0 mm/min. Data was analyzed using 3-way analysis of variance (ANOVA) and Tukey's test. Results: Three-way ANOVA revealed significant interactions between time, type of composite, and storage condition (p = 0.001). Tukey's multiple comparison test revealed significant reductions in FS of all composites after 6 months and 1 year of storage in distilled water compared to dry condition. Conclusions: Filtek P90 showed the highest and GC Kalore showed the lowest FS after 1 year storage in distilled water. The immediate high strength of Filtek Z250 significantly decreased at 1 year and its final value was lower than that of Filtek P90.

Microhybrid versus nanofill composite in combination with a three step etch and rinse adhesive in occlusal cavities: five year results

  • Tuncer, Safa;Demirci, Mustafa;Oztas, Evren;Tekce, Neslihan;Uysal, Omer
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.253-263
    • /
    • 2017
  • Objectives: The aim of the study was to evaluate the 5-year clinical performance of occlusal carious restorations using nanofill and microhybrid composites, in combination with 3-step etch-and-rinse adhesives, in patients who were going to commence orthodontic treatment. Materials and Methods: A total of 118 restorations for occlusal caries were conducted prior to orthodontic treatment. Occlusal restorations were performed both with Filtek Supreme XT (3M ESPE) and Filtek Z250 (3M ESPE) before beginning orthodontic treatment with fixed orthodontic bands. Restorations were clinically evaluated at baseline and at 1, 2, 3, 4, and 5-year recalls. Results: None of the microhybrid (Filtek Z250) and nanofill (Filtek Supreme XT) composite restorations was clinically unacceptable with respect to color match, marginal discoloration, wear or loss of anatomical form, recurrent caries, marginal adaptation, or surface texture. A 100% success rate was recorded for both composite materials. There were no statistically significant differences in any of the clinical evaluation criteria between Filtek Z250 and Filtek Supreme XT restorations for each evaluation period. Conclusions: The composite restorations showed promising clinical results relating to color matching, marginal discoloration, wear or loss of anatomical form, recurrent caries, marginal adaptation, and surface texture at the end of the 5-year evaluation period.

Shear Bond Strengths of Dentin Bonding Agent containing 0.2% Chlorhexidine (클로르헥시딘을 함유한 상아질 결합제의 전단결합강도)

  • Kim, Jinhyock;Kim, Kiseob;Kim, Jongsoo;Kim, Jongbin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.82-88
    • /
    • 2017
  • The purpose of this study is to investigate shear bond strengths of $Peak^{(R)}$ Universal Bond (Ultradent, USA) containing 0.2% chlorhexidine in bovine dentin. Total of 30 bovine teeth were divided into three groups, 10 teeth each. Before comparing and evaluating shear bond strength, in group I, $Adper^{TM}$ Single Bond Universal (3M ESPE, USA) was applied, in group II, processing with $Consepsis^{(R)}$ (Ultradent, USA) was followed by applying $Adper^{TM}$ Single Bond Universal, and in group III, $Peak^{(R)}$ Universal Bond was applied and filled with $Filtek^{TM}$ Z-350 XT (3M/ESPE, USA) shade B3. As a result, processing with $Consepsis^{(R)}$ after acid etching showed no statistically significant influence on shear bond strength of dentin (p > 0.05). The shear bond strength of with or without $Consepsis^{(R)}$ on $Adper^{TM}$ Single Bond Universal and that of $Peak^{(R)}$ Universal Bond showed statistically significant difference (p < 0.05).