• Title/Summary/Keyword: EMI Test

Search Result 144, Processing Time 0.027 seconds

KoDSat System Level EMC(Electro Magnetic Compatibility) Test and an Analysis of the Test Results (검증위성 시스템레벨 전자기파(EMC) 시험 및 결과에 대한 분석)

  • Seo, Min-Seok;Park, Seok-Jun;Sim, Eun-Seop;Kim, Se-Yeon;Chae, Jang-Su
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.4
    • /
    • pp.102-109
    • /
    • 2006
  • In this paper, the system level EMC radiated emission test results of KoDSat(Korea Demonstration Satellite), its affects upon the Launch vehicle and H/W improving methods regarding its over exceed value of EMC specification are discussed. Regarding its over exceed value, we estimated that DAU of KoDSat generated the exceeded EMC noise source, and these test results were analyzed using the EMC2000 tool to find out how did it affect the FTS(Flight Termination Subsystem) of KSLV-1(Korea Small Launch Vehicle). To diminish the EMC noise source of UHF(430.1Mhz) band level, we redesigned the DAU power board to be applied the various schemes for EMI noise reduction such as grounding, shielding and EMI filtering, and also verified these reworks to analyze its diminishing affects in UHF band level by means of performing the DAU box level EMC test and performing the second KoDSat's system level EMC test.

The Propose of EMI Limits for GETM Cell Using Correlation Factor between OATS and GTEM Cell (야외시험장과 GTEM 셀과의 상관계수를 이용한 GTEM 셀의 허용 기준 제안)

  • Lee, Soon-Yong;Chung, Yeon-Choon;Choi, Jea-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • This study is about the limits of GTEM cell using correlation factor between the OATS(Open area Test Site) and the GTEM cell. First, the field strengths at the 10 m distance OATS and in GTEM cell to obtain the experimental correlation factor are measured. Also, the EMI limits of radiated power are derived in GTEM cell as 3 position method is inversely transformed. The field strengths that calculated from theoretical models by 3 and 15 position methods are programmed and compared with measured data at the OATS. As the EMI limits of GTEM cell is newly defined, it will be use to substitute GTEM cell for OATS to efficiently measure EMI(Electromagnetic Interference).

Evaluation of the Characteristics of Semi-Anechoic Chamber for the Vertical Polarization (전파발무향심의 수직편파에 대한 특성평가)

  • 김동일;정세모;김민석
    • Journal of the Korean Institute of Navigation
    • /
    • v.20 no.3
    • /
    • pp.107-115
    • /
    • 1996
  • With the rapid advance of electronic equipments and the frequent, use of them, the electromagnetic environments including EMC or EMI problems are very complicated. The radiation of electromagnetic waves from electronic equipments has strictly been controlled by the authorities concerned from many years ago. Though it is the most proper to test EMI or EMC in the open area test site, we have used the anechoic chamber in place of the test site because of its various restrictions. To achieve the purpose, in this paper, the performances of a few anechoic chambers according to absorbing materials are analyzed for horizontal and vertical polarizations respectively. Furthermore, the calculated and the measured site attenuations in semi-anechoic chamber made with ferrite grid are compared. The obtained results are to be valuable for designing an anechoic chamber.

  • PDF

The performance evaluation of Stirling cryocooler for thermal imaging system (IV) : Vibration, Noise, Leak test (열상장비용 스터링 극저온 냉동기 특성평가 (IV) : 진동, 소음, 누설시험)

  • 박성제;홍용주;김효봉;김양훈;최상규;나종문
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.167-170
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. A free piston and free displacer(FPFD) Stilting cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM. Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stilting cryocooler is designed, manufactured and fabricated, and performance characteristics for the vibration, acoustic noise, EMI and leak rate are evaluated. Vibration outputs are measured to 20KHz for compressor and expander, respectively. And, the objective of noise test is a noise level, less than 30㏈ at 5 m. EMI tests are carried out according to the standard MIL-STD-461C tests RE01 and RE02. Leak test for the Stilting cryocooler is performed by bombing method.

  • PDF

The Design, Manufacture and Applications of a Gap Noise Generator for Testing the Characteristics of EMI from Transmission Lines (송전선로 EMI 특성 실험용 인공잡음발생장치 설계, 제작 및 적용)

  • Ju, Yun-Ro;Yang, Gwang-Ho;Myeong, Seong-Ho;Lee, Dong-Il;Sin, Gu-Yong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.1
    • /
    • pp.23-28
    • /
    • 2002
  • In order to survey the radiation characteristics of pure line noise of unwanted noise from overhead high voltage AC transmission lines, a disk type gap noise generator was manufactured. Disk size which decides capacitance between the noise generator and earth was selected through preliminary indoor experiments and analysis by using surface charge method. The capacitance is one of principal parameters related to the injection of a proper noise current into lines. On the basis of the capacitance obtained from calculation, 5mm of space was given to the gap of the noise generator to be installed o test line and an aluminum disk of 60cm radius was made. The field experiments were performed with the noise generator hung on the Kochang 765 kV full scale test line. As the results, the useful data which can be used to analysis the radiation characteristics of noise from transmission lines were obtained. Those are the directivity of antenna toward the line, lateral profiles, frequency spectra, height pattern and so on.

A Broadband Reference Antenna to Measure an Electromagnetic Interference in the Range form 30MHz to 300MHz (30 MHz에서 300MHz 대역의 전자파 장해 즉정용 광대역 기준 안테나)

  • 조원서;황호정
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.3A
    • /
    • pp.417-423
    • /
    • 2000
  • A broadband antenna available in the range of 30MHz for electromagnetic interference (EMI) test is proposed in this paper, This antenna is configurated in a disk-loaded cylindrical dipole (DLCD) connected to an 180。 hybrid balun consisting of two coaxial feeders. The performance of EMI antenna is characterized with its accurate antenna factor. The antenna factor for this antenna is obtained by using the method of moments and the calculated results are compared with the measured ones. Normalized site attenuation (NSA) is also measured by using this antenna. The results present that the propose antenna could be used for a reference antenna having measurement reproducibility and represented by a theoretically accurate analysing model in EMI measurement.

  • PDF

The Study of Tilting Train Test for electromagnetic interference(EMI) (한국형 틸팅열차 EMI에 관한 연구)

  • Song, Yong-Soo;Han, Seong-Ho;Jang, Dong-Uk;Lee, Gi-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.494-496
    • /
    • 2008
  • Tilting train has been developed to increase the operational speed of the trains on conventional lines which have many curves. This train are tilted at curves to compensate for unbalanced carbody centrifugal acceleration to a greater extent than compensation produced by the track cant so that passengers do not feel centrifugal acceleration and thus trains can run at higher speed at curves. This paper developed tilting train to evaluate electromagnetic interference(EMI) performance of TTX(tilting train express) with maximum operation speed 160 km/h on Ho_nam Conventional Rail[1].

  • PDF

Broad-Band Design of Ferrite One-body EM Wave Absorbers for an Anechoic Chamber

  • Kim, Dong-Il;Son, June-Young;Park, Woo-Keun;Park, Dong-Han
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.2
    • /
    • pp.51-55
    • /
    • 2004
  • With the progress of the electronics industry and radio communication technology, certain problems, such as electromagnetic interference(EMI), have arisen due to the increased use of electromagnetic(EM) waves. International organizations such as CISPR, FCC, and ANSI have provided the standards for the EM wave environment and for the countermeasure of the electromagnetic compatibility(EMC). EM wave absorbers are used for constructing an anechoic chamber to test and measure EMI and electromagnetic susceptibility(EMS). In this paper, we have designed an one-body EM(electromagnetic) wave ferrite absorber, based on the equivalent material constants method for both normally and obliquely incident waves, whose absorption abilities are superior to that of the conventional ones. The fabricated absorber has a thickness of 27.68 mm and shows an absorption ability over 20 ㏈ in the frequency from 30 MHz to 6 ㎓.

A Study on the Evaluation of Semi-Anechoic Chamber Characteristics (전파반무향실의 특성평가에 관한 연구)

  • 김민석;김동일
    • Journal of the Korean Institute of Navigation
    • /
    • v.21 no.4
    • /
    • pp.29-38
    • /
    • 1997
  • Because of the result of a large use of electronic equipments, the occupation density of microwave frequency band is highly increased, and electromagnetic environment is getting more seriously bad. It is sometimes reported that electronic machines are not normally operated on account of the influence of undesired electromagnetic wave, which often gives fatal blow to even human life and thus becomes serious social problems. OATS(Open Area Test Site) is principally used to measure EMI or examine elelctromagnetic emission. Because of various restrictions we often build semi-anechoic chamber which has the function of OATS to measure EMI or EMS other than OATS. If the difference of the site attenuation between semi-anechoic chamber and OATS is within ${\pm}3dB$, the semi-anechoic chamber is recognized as adequate facility to measure EMI or EMS. Accordingly authors evaluate and analyze site attenuation due to absorbent materials, polarization, mutual coupling effects, etc. The calculated and the measured site attenuation in semi-anechoic chamber are compared. As a result good agreement is obtained.

  • PDF

Equivalent Parallel Capacitance Cancellation of Common Mode Chokes Using Negative Impedance Converter for Common Mode Noise Reduction

  • Dong, Guangdong;Zhang, Fanghua
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1326-1335
    • /
    • 2019
  • Common mode (CM) chokes are a crucial part in EMI filters for mitigating the electromagnetic interference (EMI) of switched-mode power supplies (SMPS) and for meeting electromagnetic compatibility standards. However, the parasitic capacitances of a CM choke deteriorate its high frequency filtering performance, which results in increases in the design cycle and cost of EMI filters. Therefore, this paper introduces a negative capacitance generated by a negative impedance converter (NIC) to cancel the influence of equivalent parallel capacitance (EPC). In this paper, based on a CM choke equivalent circuit, the EPCs of CM choke windings are accurately calculated by measuring their impedance. The negative capacitance is designed quantitatively and the EPC cancellation mechanisms are analyzed. The impedance of the CM choke in parallel with negative capacitances is tested and compared with the original CM choke using an impedance analyzer. Moreover, a CL type CM filter is added to a fabricated NIC prototype, and the insertion loss of the prototype is measured to verify the cancellation effect. The prototype is applied to a power converter to test the CM conducted noise. Both small signal and EMI measurement results show that the proposed technique can effectively cancel the EPCs and improve the CM filter's high frequency filtering performance.