• Title/Summary/Keyword: E-J power

Search Result 823, Processing Time 0.027 seconds

Calculation of Reclosing Dead Time of 500 kV Horizontal Single Circuit Transmission Line (500 kV 수평배열 1회선 송전선로의 재폐로 무전압시간 산정)

  • Shim, E.B.;Kwak, J.S.;Joo, H.J.;Park, H.S.;Kang, Y.W.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.641-643
    • /
    • 2005
  • It is usual to operate the long transmission line with transposition of each phase in order to avoid voltage unbalance due to unbalanced capacitances at each phase of the line end. This paper described the Ferranti voltage rise of line end, charging current and secondary arc current according to the transposition of line or not. The positive and negative sequence current was derived by the phase current, and then the unbalanced rate was calculated. Then, we obtained the reclosing dead time of the single phase reclosing scheme for 500 kV single circuit horizontal arrangement transmission line system.

  • PDF

Overvoltage Analysis and Air Clearance Design of 345kV/154kV Transmission Tower (345kV/154kV 계통 과전압 해석과 공기절연간격 산정)

  • Shim, E.B.;Woo, J.W.;Kwak, J.S.;Yoon, S.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.449-451
    • /
    • 2001
  • This paper described the switching overvoltage analysis on the 345kV and 154kV transmission system by EMTP(Electromagnetic transient Program) for the enactment of current insulation design standards of KEPCO. The air clearance design of current transmission tower was reviewed and revised by the calculated result, considering swing angle for the each type of insulator string by the wind velocity.

  • PDF

Educational Simulator for Transmission Network Use of System Charge (송전망 이용요금산정을 위한 교육용 시뮬레이터 개발)

  • Kim, H.H.;Song, H.Y.;Lee, C.J.;Park, J.B.;Shin, J.R.
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.201-203
    • /
    • 2006
  • This paper presents a graphical windows-based software for the education and training of the transmission network use of system charge. The developed simulator consist of the main module(MMI,GUI), the power flow module(PF), the power flow tracing module(PFT) and management of usage cost DB module(UCD). Each module has a separate graphical and interactive interfacing window. To have effective education for transmission network use of system charge, the developed simulator are provided with two power system analysis methods. Input data of power system can use the format of PSS/E input data. Also calculation of power flow tracing are provided with four methods such as "Felix Wu","Modified Felix Wu", "DCLF ICRP" and "Reverse MW mile". Results of calculation for usage cost are shown on the window through the table or chart. Therefore user can confirm the detailed differences of results from each calculation method.

  • PDF

MC21/CTF and VERA multiphysics solutions to VERA core physics benchmark progression problems 6 and 7

  • Kelly, Daniel J. III;Kelly, Ann E.;Aviles, Brian N.;Godfrey, Andrew T.;Salko, Robert K.;Collins, Benjamin S.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.6
    • /
    • pp.1326-1338
    • /
    • 2017
  • The continuous energy Monte Carlo neutron transport code, MC21, was coupled to the CTF subchannel thermal-hydraulics code using a combination of Consortium for Advanced Simulation of Light Water Reactors (CASL) tools and in-house Python scripts. An MC21/CTF solution for VERA Core Physics Benchmark Progression Problem 6 demonstrated good agreement with MC21/COBRA-IE and VERA solutions. The MC21/CTF solution for VERA Core Physics Benchmark Progression Problem 7, Watts Bar Unit 1 at beginning of cycle hot full power equilibrium xenon conditions, is the first published coupled Monte Carlo neutronics/subchannel T-H solution for this problem. MC21/CTF predicted a critical boron concentration of 854.5 ppm, yielding a critical eigenvalue of $0.99994{\pm}6.8E-6$ (95% confidence interval). Excellent agreement with a VERA solution of Problem 7 was also demonstrated for integral and local power and temperature parameters.

Ion-induced secondary electron emission coefficient and work function for MgO thin film with $O_2$ plasma treatment

  • Jung, J.C.;Jeong, H.S.;Lee, J.H.;Oh, J.S.;Park, W.B.;Lim, J.Y.;Cho, J.W.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.525-528
    • /
    • 2004
  • The ion-induced secondary electron emission coefficient ${\gamma}$ and work function for MgO thin film with $O_2$ plasma treatment has been investigated by ${\gamma}$ -FIB (focused ion beam) system. The MgO thin film deposited from sintered material with $O_2$ plasma treatment is found to have higher ${\gamma}$ and lower work function than those without $O_2$ plasma treatment. The energy of various ions used has been ranged from 100eV to 200eV throughout this experiment. It is found that the highest secondary electron emission coefficient ${\gamma}$ has been achieved for 10 minutes of $O_2$ plasma treatment under RF power of 50W.

  • PDF

Study for the development of assembly type joint boxes for extra high voltage power cables (초고압 전력 케이블용 조립식 접속상의 개발을 위한 연구)

  • Seo, J.Y.;Park, J.S.;Lee, H.S.;Oh, E.J.;Han, B.S.;Hahn, K.M.;Lee, K.C.;Jeon, S.I.;Han, M.K.;Lee, J.H.;Shin, P.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.925-927
    • /
    • 1992
  • Since that the portion of failures caused by mis-installation of accessories is about 50% of whole failures in power transmission lines, the necessity of assembly type joint boxes, which have excellent installation capability and which can be electrically tested before installation, is gradually increasing. In this paper, we presented the results from the study from the point of design and the results of experiments using models. With the results of study, we could make it clear that the possibility of practical use of assembly type joint boxes instead of conventional molding type joint boxes is very high.

  • PDF

The new lightning detection system of KEPCO Lightning Detection & information Network (한전의 새로운 낙뢰측정 네트워크 KLDNet)

  • Woo, J.W.;Kwak, J.S.;Shim, E.B.;Won, B.J.;Moon, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.83-84
    • /
    • 2006
  • Lightning induced faults accounts for more than 66% at the transmission lines of KEPCO. The lightning causes damages to power system equipments including transmission line, the shut down of electricity and the electro-magnetic interference. Because of this reason, we need the real time lightning information for the optimal operation of power system. And, it is required to obtain and accumulate the lightning current parameters for the insulation design. A lightning detection system, LPATS, has been operated since 1995 in KEPCO. For the improved detection efficiency, we had in stalled the new lightning detection network named as KLDNet in 2005. Also, we had developed the new software for the lightning parameters analysis and real time information service on the WEB. In this paper, we would like to introduce about the new system.

  • PDF

Analysis of the lightning characteristics by LPATS Data during 7 year (LPATS에 의한 7년간의 한반도 뇌격특성분석)

  • Woo, J.W.;Shim, E.B.;Kwak, J.S.;Kweon, D.J.;Moon, J.D.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.509-511
    • /
    • 2003
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF