• 제목/요약/키워드: Dynamic steady-state

검색결과 680건 처리시간 0.026초

The Starting Characteristics of the Steady Ejector-Diffuser System

  • Gopalapillai, Rajesh;Kim, Heuy-Dong;Matsuo, Shigeru;Setoguchi, Toshiaki
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.680-685
    • /
    • 2008
  • The ejector is a simple device which can transport a low-pressure secondary flow by using a high-pressure primary flow. In general, it consists of a primary driving nozzle, a mixing section, and a diffuser. The ejector system entrains the secondary flow through a shear action generated by the primary jet. Until now, a large number of researches have been made to design and evaluate the ejector systems, where it is assumed that the ejector system has an infinite secondary chamber which can supply mass infinitely. However, in almost all of the practical applications, the ejector system has a finite secondary chamber implying steady flow can be possible only after the flow inside ejector has reached an equilibrium state after the starting process. To the authors' best knowledge, there are no reports on the starting characteristics of the ejector systems and none of the works to date discloses the detailed flow process until the secondary chamber flow reaches an equilibrium state. The objective of the present study is to investigate the starting process of an ejector-diffuser system. The present study is also planned to identify the operating range of ejector-diffuser systems where the steady flow assumption can be applied without uncertainty. The results obtained show that the one and only condition in which an infinite mass entrainment is possible is the generation of a recirculation zone near the primary nozzle exit. The flow in the secondary chamber attains a state of dynamic equilibrium at this point.

  • PDF

이중여자 유도발전기에 의한 가변속 풍력 발전시스템의 동특성 해석 (Dynamic Analysis of Variable Speed Wind Power Systems with Doubly-Fed Induction Generators)

  • 최장영;장석명
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권6호
    • /
    • pp.325-336
    • /
    • 2006
  • This paper deals with the dynamic analysis of variable speed wind power systems with doubly-fed induction generators (DFIG). First, the mathematical modeling of wind farm which consists of turbine rotor, DFIG, rotor side and grid side converter and control systems is presented. In particular, the equation for dynamic modeling of the DFIG and the AC/DC/AC converter is expressed as dq reference frame. And then, on the basis of mathematical modeling for each component of wind farm, dynamic simulation algorithms for speed and pitch angle control of wind turbine and generated active and reactive power control of the DFIG and the AC/DC/AC converter are established. Finally, Using the MATLAB/SIMULINK, this paper presents dynamic simulation model for 6MW wind power generation systems with the DFIG considering distribution systems and performs the dynamic analysis of wind power systems in steady state. Moreover, this paper also presents the dynamic performance for the case when the voltage sag in grid source and phase fault in bus are occurred.

석유화학 플랜트의 배관계 설계기준에 대한 연구 (A Study on Design Criteria of Piping System in Petrochemical Plant)

  • 민선규;최명진
    • 한국정밀공학회지
    • /
    • 제19권6호
    • /
    • pp.192-199
    • /
    • 2002
  • Largely, there are three kinds of the design criteria of piping system in petrochemical plant. The first is on the pipe thickness in accordance with the design pressure of piping system. The second is on the static state evaluation by thermal growth and the other is on the dynamic evaluation by piping vibration. According to the ASME B31.3 code, the internal pressure design thickness fur straight pipe shall be calculated as a code formula. And the static design by thermal displacement is defined 7000 cycles of fatigue life in operating the piping system with a design condition. However, the dynamic design evaluation in comparative with small displacements of high frequencies to the static condition has not established clearly the method, yet. So, this study purposes to present the trial of a proposal of dynamic design criterion on the basis of static design method.

순시전압 sag 및 고조파 전류 보상을 위한 공간벡터 검출법 기반의 3상 하이브리드 직렬형 능동전력필터 (The Space Vector Detection based Three-Phase Hybrid Series Active Power Filter for Compensating Dynamic Voltage Sag and Harmonic Current)

  • 양승환;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제9권4호
    • /
    • pp.303-310
    • /
    • 2004
  • 본 연구에서는 순시전압 sag 및 고조파 전류 보상을 위한 공간벡터 검출법을 기반으로 한 3상 하이브리드 직렬형 능동전력필터 시스템을 제안하고 있다. 순시전안 sag 및 고조파 전류를 검출하기 위한 공간벡터 검출법은 종전의 이론에 비해 곱셈 연산 과정을 감소할 수 있고 좌표 변환이 필요치 않기 때문에 간략화한 보상 알고리즘 구현이 가능하다. 본 연구의 타당성은 전력전자전용 시뮬레이터 PSIM에 의해 정상상태와 과도상태에서 입증하였다. 그 결과 3상 교류 전원 모두에 순간적인 전압 sag가 발생되거나, 임의의 상에 왜형 및 sag가 있는 경우, 전압 보상 및 고조파 전류 보상이 모두 가능함을 입증하였다.

절연형 Inverse-SEPIC의 모델링 및 제어 특성 (Modeling and Control Characteristics of Isolated Inverse-SEPIC)

  • 박한얼;김은석;김수석;송중호
    • 전력전자학회논문지
    • /
    • 제13권1호
    • /
    • pp.1-8
    • /
    • 2008
  • 상태 공간 평균화법을 이용하여 절연형 inverse-SEPIC(Isolated Inverse-SEPIC)의 동적 모델링을 정립하고, 그 제어특성을 해석한다. 정상 상태 해석을 통해 회로의 주요 소자들에 대한 설계식을 유도한다. 근 궤적과 주파수 해석을 통해 II-SEPIC의 동특성 및 제어 특성을 파악하여, 적절한 제어성능을 가지는 제어기를 설계한다. 본 논문에서 제시하는 방법에 따라 설계된 II-SEPIC의 회로파라미터 및 전압제어기를 포함한 전체 제어시스템의 시뮬레이션과 실험을 수행한다. 시뮬레이션과 실험결과는 논문에서 제시한 모델링 및 제어기 설계방법의 타당성 및 유용성을 확인시켜 주고 있다.

DYNAMIC SIMULATION MODEL OF A HYBRID POWERTRAIN AND CONTROLLER USING CO-SIMULATION - PART I: POWERTRAIN MODELLING

  • Cho, B.;Vaughan, N.D.
    • International Journal of Automotive Technology
    • /
    • 제7권4호
    • /
    • pp.459-468
    • /
    • 2006
  • The objective of this paper is the development of the forward-looking dynamic simulation model of a hybrid electric vehicle(HEV) for a fuel economy study. The specification of the vehicle is determined based on two factors, engine peak power to curb weight ratio and specific engine power. The steady state efficiency models of the powertrain components are explained in detail. These include a spark ignition direct injection(SIDI) engine, an integrated starter alternator(ISA), and an infinitely variable transmission(IVT). The paper describes the integration of these models into a forward facing dynamic simulation diagram using the AMESim environment. Appropriate vehicle and driver models have been added and described. The controller was designed in Simulink and was combined with the physical powertrain model by the co-simulation interface. Finally, the simulation results of the HEV are compared with those of a baseline vehicle in order to demonstrate the fuel economy potential. Results for the vehicle speed error and the fuel economy over standard driving cycles are illustrated.

마찰감쇠기가 설치된 건물 응답의 근사해 : 재 고찰 및 새로운 결과 (Approximate solution for a building installed with a friction damper : revisited and new result)

  • 민경원;성지영;이성경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.850-854
    • /
    • 2009
  • Approximate analysis for a building installed with a friction damper is revisited to get insight of its dynamic behavior. Energy balance equation is used to have a closed analytical form solution of dynamic magnification factor (DMF) for the building with combined viscous and friction damping. It is found out that DMF is dependent on friction force ratio and resonance frequency. Linear transfer function from input external force to output building displacement is obtained by simplifying DMF equation. Root mean square of building displacement is derived under earthquake-like random excitation. Finally, design of friction damper is proposed by processing target control ratio, damping ratio factor, and friction force in sequence.

  • PDF

열해석 모델 간략화 및 동적특성에 관한 연구 (A STUDY ON THERMAL MODEL REDUCTION AND DYNAMIC RESPONSE)

  • 전형열;김정훈
    • 한국전산유체공학회지
    • /
    • 제19권4호
    • /
    • pp.37-44
    • /
    • 2014
  • A detailed satellite panel thermal model composed of more than thousands nodes can not be directly integrated into a spacecraft thermal model due to its node size and the limitation of commercial satellite thermal analysis programs. For the integration of the panel into the satellite thermal model, a reduced thermal model having proper accuracy is required. A thermal model reduction method was developed and validated by using a geostationary satellite panel. The temperature differences of main components between the detailed and the reduced thermal model were less than $1^{\circ}C$ in steady state analysis. Also, the dynamic responses of the detailed and the reduced thermal model show very similar trends. Thus, the developed reduction method can be applicable to actual satellite thermal design and analysis with resonable accuracy and convenience.

내부 비정상 유동을 갖는 파이프계의 스펙트럼요소해석 (Spectral Element Analysis of the Pipeline Conveying Internal Unsteady Fluid)

  • 박종환;이우식
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1574-1585
    • /
    • 2005
  • In this paper, a spectral element model is developed for the uniform straight pipelines conveying internal unsteady fluid. Four coupled pipe-dynamics equations are derived first by using the Hamilton's principle and the principles of fluid mechanics. The transverse displacement, the axial displacement, the fluid pressure and the fluid velocity are all considered as the dependent variables. The coupled pipe-dynamics equations are then linearized about the steady state values of the fluid pressure and velocity. As the final step, the spectral element model represented by the exact dynamic stiffness matrix, which is often called spectral element matrix, is formulated by using the frequency-domain solutions of the linearized pipe-dynamics equations. The FFT-based spectral dynamic analyses are conducted to evaluate the accuracy of the present spectral element model and also to investigate the structural dynamic characteristics and the internal fluid transients of an example pipeline system.

솔레노이드 가스 인젝터의 유량제어와 천연가스엔진에서의 응용 (Flow Control of a Solenoid Gas Injector and Its Application on a Natural Gas Engine)

  • 심한섭
    • 한국기계가공학회지
    • /
    • 제8권2호
    • /
    • pp.83-89
    • /
    • 2009
  • An air-fuel ratio control is essential in reducing hazardous exhaust emissions from a compressed natural gas(CNG) engine, and can be accomplished by accurate control of gas injection flow. In this study, theoretical research was conducted on injection characteristics of a solenoid gas injector, and injection experiments for calibration and analysis were performed. Various factors for gas injection flow such as injection pressure, gas temperature, and supply voltage are studied. A dynamic flow equation of the natural gas was proposed on the basis of flow dynamics theories and results of the injection experiment. The verification of the dynamic flow equation of the solenoid injector was carried out with a large CNG-engine applied to an urban bus. Air-fuel ratio control experiments were conducted in both steady and transient state. Results of injection experiments for the solenoid injector and the CNG-engine was proved the control method proposed herein to be effective.

  • PDF