• Title/Summary/Keyword: Dynamic imaging

Search Result 494, Processing Time 0.029 seconds

Usefulness of MRCP in the Diagnosis of Common Bile Duct Dilatation caused by Non-stone or Non-tumorous Conditions (비결석, 비종양성 총담관 확장의 진단에 있어서 자기공명담췌관조영술(MRCP)의 유용성)

  • 정재준;양희철;김명진;김주희;이종태;유형식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.129-136
    • /
    • 2002
  • Purpose : To evaluate the usefulness of MRCP in the diagnosis of the variable causes of common bile duct(CBD) dilatation, except stone or tumor Materials and methods : Twenty-six patients(M:F=15:11, mean age; 62 years) with both MRCP and ERCP were included in this study. Dynamic MRCP(n=12) and contrast-enhanced MRI(n=10) of abdomen were also added. Dilatation of CBD, intrahepatic ducts and pancreatic duct was evaluated, including coexistence of intrahepatic ductal stone, pancreatic pseudocyst, and papillary or papillary edema. The criteria of CBD dilatation was over than 7mm(n= 21, without cholecystectomy) or 10 mm(n=5, with cholecystecto-my) in diameter on T2-weighted coronal image. Results : The mean diameter of CBD was 12.7mm without cholecystectomy(9-19 mm) and 13.0 mm with cholecystectomy(10-15mm), respectively(p 〉0.05). Cholangitis(n=11, 42.3%), chronic pancreatitis(n=8, 30.8%), stenosis of distal CBD(n= 6, 23.1%), periampullary diverticulum(n=3, 11.5%), stenosis of ampulla of Vater(n=2, 7.7%), dysfunction of sphincter of Oddi(n=2, 7.7%), acute focal pancreatitis in the pancreatic head(n=2, 7.7%), papillitis(n=1, 3.8%), pseudocyst in the pancre atic head(n = 1, 3.8%), and ascaris in CBD(n=1, 3.8%) were noted. Pancreatic duct dilatation(n=10, 38.5%) and duodenal diverticulum(n=3, 11.5%) were also seen on MRC P. On dynamic MRCP(12 patients), distal CBD was visualized in 2 patients(16.7%), which was not shown on routine MRCP. Only 1 patient(10.0%) showed papillitis with slightly enhancing papilla on contrast-enhanced MRI (10 patients). Conclusion : MRCP was thought to be helpful in the evaluation of the causes of CBD dilatation, not caused by stone or tumor, especially in the cases of stenosis of distal CBD and chronic pancreatitis, dysfunction of sphincter of Oddi on dynamic MRCP and cholangitis and pericholangitic abnormality on contrast-enhanced MRI.

  • PDF

Kit Preparation and Biodistribution of $Bz-MAG_3$ (benzoylmercaptoacetylglycylglycylglycine) for Renal Imaging (신장기능영상용 방사성의 약품 $Bz-MAG_3$(Benzoylmercaptoacetylglycylglycylglycine) 의 키트화 및 체내분포)

  • Kim, Young-Ju;Jeong, Jae-Min;Cho, Jung-Hyuk;Chang, Young-Soo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.367-371
    • /
    • 1996
  • The $MAG_3$ is a tubular excreting radiopharmaceutical for renal image. We synthesized benzoyl $MAG_3\;(Bz-MAG_3)$ and made a kit for labeling with $^{99m}Tc$. We checked the labeling efficieny of $^{99m}Tc$ labeled $MAG_3$ and biodistribution. Labeling efficieny was checked by TLC-SG (acetonitrile/$H_2O$=2/1). After injecting of 1 mCi of $^{99m}Tc-MAG_3$ to ICR-mice, $T_{max}(min),\;T_{1/2}(min)$ were obtained in the renogram. Sequential images (30sec, 2min, 5min, 10min, 15min, 20min) of $^{99m}Tc-MAG_3$ were compared with those of commercial $^{99m}Tc$-DTPA (Du Pont Merck Pharmaceutical Co.) kit. 1) The $R_f$ value of synthesized $^{99m}Tc-MAG_3$ was 0.78 and labeling efficiency was $97.5{\pm}1.9%$ (n=10). 2) The dynamic images of the $^{99m}Tc-MAG_3$ were better than those of the $^{99m}Tc$-DTPA. 3) The $T_{max}(min.)$ and $T_{1/2}(min.)$ of $^{99m}Tc-MAG_3$ (n=10) were $1.5{\pm}0.5$ (left), $1.4{\pm}0.4$ (right), and $4.3{\pm}1.4$ (left), $4.8{\pm}2.0$ (right), respectively. The $T_{max}(min.)$ and $T_{1/2}(min.)$ of $^{99m}Tc$-DTPA (n=7) were $2.7{\pm}1.6$ (left), $2.7{\pm}1.6$ (right), and $3.8{\pm}1.7$ (left), $4.5{\pm}2.7$ (right), respectively. The quaility of image and labeling efficiency of the synthesized $Bz-MAG_3$ kit were excellent, that it was supposed to be used in routine clinical work.

  • PDF

Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder (무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법)

  • Yoon, Moon-Hyun;Sung, Mi-Sook;Yin, Chang-Sik;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.98-107
    • /
    • 2006
  • Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.

  • PDF

Biodistribution and Metabolism of I-123 Labelled Fatty Acid(I) : [I-123]15-(p-iodophenyl)pentadecanoic acid(IPPA) (I-123 표지 지방산의 체내 분포 및 대사(I) : [I-123]15-(p-iodophenyl)pentadecanoic acid(IPPA))

  • Chang, Young Soo;Lee, Dong Soo;Jeong, Jae Min;Suh, Yong-Sup;Chung, June-Key;Lee, Myung Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.50-60
    • /
    • 1998
  • I-123 labelled fatty acids are suitable for investigation of regional myocardial metabolism, so they are on the clinical trial. However, the precise properties of these materials are not characterized yet. We have synthesized phenylpentadecanoic acid and labeled this compound with I-123. The purpose of this study was to examine the stability, biodistribution, metabolism and SPECT imaging of [I-123]15-(p-iodophenyl)pentadecanoic acid(I-123-IPPA) that we made. The stability test of I-123-IPPA in serum of rat, mouse and human showed no free I-123 after 1 hour. In biodistribution study in mice for various time intervals after injection(5, 10, 15, 30, 60 minutes), uptake in myocardium was 14.5%ID/g(5 min), and 1.9%ID/heart(5 min), while uptake in muscles was 2.6%ID/g(5 min). Myocardium to blood ratio and myocardium to lung ratio increased for 5 min after injection and then decreased rapidly. Chromatographic data of rat blood and urine showed that little PPA was found in blood and urine at 15-20 min after injection. The myocardial I-123-IPPA SPECT images of a dog with myocardial infarction showed defects similar to those of Tc-99m-MIBI and F-18-FDG. These data suggest that I-123-IPPA is quite stable in vitro and shows favorable biodistribution in mice. SPECT imaging with I-123-IPPA demonstrated infarct zone as photon defect in dog model of myocardial infarction. I-123-IPPA may be used for the evaluation of fatty acid metabolism in clinical trials in Korea.

  • PDF

Correlation Analysis of Diffusion Metrics (FA and ADC) Values Derived from Diffusion Tensor Magnetic Resonance Imaging in Breast Cancer (유방암의 확산텐서 자기공명 영상에서 유도된 확산 지표(FA, ADC) 값의 연관성 분석)

  • Lee, Jae-Heun;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.755-762
    • /
    • 2018
  • The purpose of this study was to compare the FA(faractional anisotropy) and ADC(apparent diffusion coefficient) values, which were derived from diffusion tensor imaging in breast cancer patients. The diffusion gradient used in this study was derived from quantitative diffusion indices using 20 directions(b-value, 0 and $1,000s/mm^2$). Quantitative analysis was analyzed using Pearson's correction and qualitative analysis using for correction coefficients. As a result, $FA_{min}$, $FA_{mean}$ and $FA_{max}$ were $0.098{\pm}0.065$, $0.302{\pm}0.142$ and $0.634{\pm}0.236$, respectively(p > 0.05). The $ADC_{min}$, $ADC_{mean}$ and $ADC_{max}$ were $0.741{\pm}0.403$, $1.095{\pm}0.394$ and $1.530{\pm}0.447$, respectively(p > 0.05). The $FA_{min}$, $FA_{mean}$, and $FA_{max}$ mean values were $0.132{\pm}0.050$, $0.418{\pm}0.094$, and $0.770{\pm}0.164$ for Category 6 and Kinetic Curve Pattern III, respectively. $ADC_{min}$, $ADC_{mean}$, and $ADC_{max}$ were $0.753{\pm}0.189$, $1.120{\pm}0.236$, and $1.615{\pm}0.372$, respectively. Quantitative analysis showed negative correlation between $ADC_{mean}-FA_{mean}$ and $ADC_{max}-FA_{max}$(p = 0.001, 0.003). The qalitative analysis showed ADC 0.628(p = 0.001), FA 0.620(p = 0.001) in the internal evaluations, ADC 0.677(p = 0.001), FA 0.695(p = 0.001) in external evaluations. In conclusion, based on the morphological examination, time to signal intensity graph is the form of wash-out(pattern III) in the dynamic contrast enhance examination, As a result, the $ADC_{mean}$ $1.120{\pm}0.236$ and $FA_{mean}$ values were $0.032{\pm}0.142$ with a negative correlation (Y=1.44-1.12X). Therefore, If we understand the shape of time to signal intensity graph and the relationship between ADC and FA, It will be a criterion for distinguishing malignant diseases in breast cancer.

LI-RADS Treatment Response versus Modified RECIST for Diagnosing Viable Hepatocellular Carcinoma after Locoregional Therapy: A Systematic Review and Meta-Analysis of Comparative Studies (국소 치료 후 잔존 간세포암의 진단을 위한 LI-RADS 치료 반응 알고리즘과 Modified RECIST 기준 간 비교: 비교 연구를 대상으로 한 체계적 문헌고찰과 메타분석)

  • Dong Hwan Kim;Bohyun Kim;Joon-Il Choi;Soon Nam Oh;Sung Eun Rha
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.331-343
    • /
    • 2022
  • Purpose To systematically compare the performance of liver imaging reporting and data system treatment response (LR-TR) with the modified Response Evaluation Criteria in Solid Tumors (mRECIST) for diagnosing viable hepatocellular carcinoma (HCC) treated with locoregional therapy (LRT). Materials and Methods Original studies of intra-individual comparisons between the diagnostic performance of LR-TR and mRECIST using dynamic contrast-enhanced CT or MRI were searched in MEDLINE and EMBASE, up to August 25, 2021. The reference standard for tumor viability was surgical pathology. The meta-analytic pooled sensitivity and specificity of the viable category using each criterion were calculated using a bivariate random-effects model and compared using bivariate meta-regression. Results For five eligible studies (430 patients with 631 treated observations), the pooled per-lesion sensitivities and specificities were 58% (95% confidence interval [CI], 45%-70%) and 93% (95% CI, 88%-96%) for the LR-TR viable category and 56% (95% CI, 42%-69%) and 86% (95% CI, 72%-94%) for the mRECIST viable category, respectively. The LR-TR viable category provided significantly higher pooled specificity (p < 0.01) than the mRECIST but comparable pooled sensitivity (p = 0.53). Conclusion The LR-TR algorithm demonstrated better specificity than mRECIST, without a significant difference in sensitivity for the diagnosis of pathologically viable HCC after LRT.

Radiologic Findings of Cervical Mass Type Cervical Pregnancy (자궁경부 종괴형 자궁경부임신의 영상 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.1
    • /
    • pp.43-51
    • /
    • 2005
  • Background: To examine the ultrasonographic and magnetic resonance (MRI) imaging findings of a cervical mass type cervical pregnancy. Materials and Methods: The ultrasonographic and MRI findings of 5 patients pathologically confirmed as having a cervical pregnancy were analyzed retrospectively. On ultrasonography, the size and echo pattern of the uterine cervix, the shape and echo pattern of the lesion, the degree and the pattern of blood flow on the color Doppler study and the spectral Doppler pattern were analyzed. The shape, signal intensity, and degree and pattern of enhancement of the lesion were evaluated on MRI. Results: The uterine cervix was enlarged and the size of the lesion was 6.1 to 7.1 (average, 6.5) cm. The endocervical canal was irregularly dilated and showed heterogeneous echogenicity in all 5 cases. Four of the 5 lesions were heterogeneously hyper- or mixed echoic and remaining one was relatively homogeneous echogenic. Doppler ultrasonography revealed an increased vascularity of the peritrophoblastic flow pattern. In all 4 cases where MRI performed, the lesion was irregular in shape and the margin was not sharply demarcated. The T2-weighed image showed that the lesions were mixed signal intensity. Three of the 4 lesions contained high signal intensity nodular portions and a low signal intensity rim was observed along the margin of the nodular portions. The T1-weighted image revealed multiple signal voids along the periphery of the lesions and high signal intensity portions as a result of hemorrhage were noted. The dynamic enhanced study showed that the high signal intensity portions on the T2-weighted image were strongly enhanced similar to the vessels on the early phase and the contrast enhancement gradually decreased with time. Conclusion: A cervical mass type cervical pregnancy can be correctly diagnosed using the patient's clinical symptom, the elevation in the serum ${\beta}$-HCG level, and characteristic ultrasonographic and MRI findings.

  • PDF

Changes of abdominal muscle thickness during stable and unstable surface bridging exercise in young people

  • Kim, Tae Hoon;Hahn, Joohee;Jeong, Ju-Ri;Lee, Changjoo;Kim, You Jin;Choi, Sung Min;Jeon, Da Young;Lee, Jin Hwa;Lim, In-Hyuk;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.4
    • /
    • pp.210-214
    • /
    • 2016
  • Objective: The aim of this study was to measure the muscle architectural parameters of abdominal muscles in healthy individuals by rehabilitative ultrasound imaging (RUSI) and to investigate their changes after bridging exercise in various environments. Design: Cross-sectional study. Methods: The study included 40 healthy participants (19 men, 21 women). Subjects were randomly allocated to a stable surface group (SG, n=20) or an unstable surface group (UG, n=20). The participants assumed three positions in rest, bridging exercise with knee flexion $60^{\circ}$, and bridging exercise with knee flexion $90^{\circ}$ for the measurement of abdominal muscle thickness by RUSI. For the resting position, the participants held the head neutral in a hook-lying position and the dominant side was measured. For contraction, the participants performed the bridging exercise with the knee joint in $60^{\circ}$ and $90^{\circ}$ of flexion for 10 seconds each. Results: For transversus abdominis, external oblique muscle thickness, within the stable surface group and the unstable surface group, no significant contraction difference was observed in both the $60^{\circ}$ and $90^{\circ}$ bridge exercise conditions. Contraction difference of internal oblique muscle was significantly larger at $90^{\circ}$ than at $60^{\circ}$ within the SG (p<0.05). But within the UG, no significant contraction difference was shown. There was no significant contraction difference between the surface group and the unstable SG at $60^{\circ}$ condition and at $90^{\circ}$ condition in all measured muscles. Conclusions: The contraction difference is different for each muscle during bridge exercise with knee flexion $60^{\circ}$ and bridging exercise with knee flexion $90^{\circ}$. Muscle contraction difference is generally large when exercised on an unstable surface than a stable surface, but these are not statistically significant when bridging exercise is performed using dynamic air cushion for unstable surface.

Study on Development of Automated Program Model for Measuring Sensibility Preference of Portrait (인물사진의 감성 선호도 측정 자동화 프로그램 모형 개발 연구)

  • Lee, Chang-Seop;Jung, Da-Yeon;Lee, Eun-Ju;Har, Dong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.9
    • /
    • pp.34-43
    • /
    • 2018
  • The purpose of this study is to develop measurement program model for a human being-oriented product through the between the evaluation factors of portrait and general preferences of portraits. We added new items that are essential to the image evaluation by analysing previous studies. In this study, We identified the facial focus for the first step, and the portraits were evaluated by dividing it into objective and subjective image quality evaluation items. RSC Contrast and Dynamic Range were selected as the Objective evaluation items, and the numerical values of each image could be evaluation items, and the numerical values of each image could be evaluated by statistical analysis method. Facial Exposure, Composition, Position, Ratio, Out of focus, and Emotions and Color tone of image were selected as the Subjective evaluation items. In addition, a new face recognition algorithm is applied to judge the emotions, the manufacturer can get the information that they can analyze the people's emotion. The program developed to quantitatively and qualitatively compiles the evaluation items when evaluating portraits. The program that I developed through this study can be used an analysis program that produce the data for developing the evaluation model of the product more suitable to general users of imaging systems.

A study of Brain Micro-PET Imaging and Bindingpotential with a Different Specific Activity of 18F-Fallypride in the Small Animal (소동물에서 18F-Fallypride의 비방사능에 따른 뇌의 PET이미지와 Binding Potential 차이에 대한 연구)

  • Cho, Kyu-Sang;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.418-424
    • /
    • 2015
  • In this study, we proceed if there are any changes in binding ability of receptor-ligand in some degree of SA and in radioactive uptake from the corpus striatum based on small animal experiment in vivo based on the S.A values. By dividing 18F-Fallypride into 3 S.A values(high S.A : 43.29~74 GBq/umol, ordinary S.A : 20.72~29.23 GBq/umol, low S.A : 6.29~8.51 GBq/umol), we injected directly into the veins and performed 90 minutes of dynamic scan using Micro PET. After scanning, we compared and analyzed with Binding Potential (Binding Potential) from the bilateral striatum. high SA and low SA, ordinary SA and low SA showed significant differences. Also, in the image comparison using 18F-Fallypride show high radioactive uptake in the striatum at high SA and ordinary SA, but the radioactive uptake at low SA is lower than other two SA. Since 18F-Fallypride has affinity to dopamine D2/3 pharmacokinetic, the difference of Binding Potentials at decreased level of SA values was not that significant. However, further PET research of the corpus striatum using 18F-Fallypride is necessary because the differences in images and Binding Potentials at 6.5 times smaller SA values compared to high SA value showed were significant.