• 제목/요약/키워드: Dynamic UPS

검색결과 67건 처리시간 0.028초

크리깅 근사모델기반 복합충격 저항 샌드위치 패널 최적설계 (Design Optimization of Blast and Ballistic Impact Resistance Sandwich Panels Based on Kriging Approximate Models)

  • 장성우;백운경;최해진;박순석
    • 한국CDE학회논문집
    • /
    • 제20권4호
    • /
    • pp.367-374
    • /
    • 2015
  • Sandwich panels consisting of various materials have widely been applied for mitigating dynamic impacts such as ballistic and blast impacts. Especially, the selection of materials for different core set-ups can directly influence its performance. In this study, we design the sandwich panels for alleviating ballistic and blast impacts by controlling the stacking sequence of core materials and their thicknesses. FEM studies are performed to simulate the dynamic behavior of sandwich panels subjected to ballistic and blast impacts. Delamination between the core layers is also considered in the FEM studies for feasible design. Based on the FEM data, kriging models are generated for approximating design space and quickly predicting the FEM outputs. Finally, design optimizations are implemented to find the optimum stacking sequence of core materials and thicknesses with given impact situations.

An SCR Thyristor Based Three-Phase Voltage Disturbance Generator

  • Han, Heung-Soo;Jung, Jae-Hun;Nho, Eui-Cheol;Kim, In-Dong;Kim, Heung-Geun;Chun, Tae-Won
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.372-378
    • /
    • 2012
  • This paper deals with a 3-phase voltage disturbance generator for a performance test of custom power devices such as dynamic voltage restorers (DVR), dynamic uninterruptable power supplies (UPS), etc. The operating principle of the proposed circuit is described in each mode of voltage sag, swell, outage, and unbalance. The main components of the proposed disturbance generator are silicone controlled rectifier (SCR) thyristors, variable autotransformers, and transformers. Therefore, the disturbance generator can be implemented with a considerably low cost compared to the conventional pulse width modified (PWM) inverter and converter type generators. Furthermore, it has good features of high reliability with simple structure, high efficiency caused by no PWM switching of the SCR thyristors, and easy control with a wide variation range. To verify the validity of the proposed scheme, simulations and experiments are carried out.

Dynamic Precipitation and Substructure Stablility of Cu Alloy during High Temperature Deformation

  • Han, Chang-Suk;Choi, Dong-Nyeok;Jin, Sung-Yooun
    • 한국재료학회지
    • /
    • 제29권6호
    • /
    • pp.343-348
    • /
    • 2019
  • Structural and mechanical effects of the dynamical precipitation in two copper-base alloys have been investigated over a wide range of deformation temperatures. Basing upon the information gained during the experiment, also some general conclusion may be formulated. A one concerns the nature of dynamic precipitation(DP). Under this term it is commonly understood decomposition of a supersaturated solid solution during plastic straining. The process may, however, proceed in two different ways. It may be a homogeneous one from the point of view of distribution and morphological aspect of particles or it may lead to substantial difference in shape, size and particles distribution. The effect is controlled by the mode of deformation. Hence it seems to be reasonable to distinguish DP during homogeneous deformation from that which takes place in heterogeneously deformed alloy. In the first case the process can be analyzed solely in terms of particle-dislocation-particle interrelation. Much more complex problem we are facing in heterogeneously deforming alloy. Deformation bands and specific arrangement of dislocations in form of pile-ups at grain boundaries generate additional driving force and additional nucleation sites for precipitation. Along with heterogeneous precipitation, there is a homogeneous precipitation in areas between bands of coarse slip which also deform but at much smaller rate. This form of decomposition is responsible for a specially high hardening rate during high temperature straining and for thermally stable product of the decomposition of alloy.

내진검증(안전)을 위한 실험적 고찰을 이용한 해석 모델 개발연구 (A Test Verified Model Development Study for Seismic Qualification(Safety))

  • Uk-Hwan Sur
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.286-291
    • /
    • 1998
  • 이 논문은 기기검증 중 내진검증(안전)을 위한 접근방법의 일환으로 실험을 통한 유한요소 해석 모델을 개발하였다. 이 모델은 한국원자력연구소 내의 하나로원자로 전기설비 중의 일부분인 UPS를 내진검증하기 위한 것이다. 이 시험증명용 모델은 50Hz 미만의 모든 주요 모드에서 고유진동수가 약 5%이내의 오차를 갖는 값을 예측하였다. 이 모델은 내진검증을 위한 최종 응력해석에 적합하였으며 실제 기기의 동적특성의 예측에 고 정밀도를 보여주었다.

  • PDF

전력품질 보상장치의 순간전압강하에 관한 연구 (A study on Voltage Sag Detection of Power Quality Compensator)

  • 이재영;이원선;한운동;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.760-763
    • /
    • 2004
  • The recent growth in the use of impactive and nonlinear loads, electronic, and medical devices sensitive to power quality has caused many power quality problems and power supply-and-demand problem. Recently, in power system not only the reliability of the power supply but also the DVR(Dynamic Voltage Restorer), UPS, and APF are being studied more and more. Hence, in this paper, Voltage sag detection algorithm for voltage sag corrector is proposed. Also, simple circuit for the experimental voltage sag is Introduced.

  • PDF

DSP를 기반으로한 DVR의 전압제어기 구현 (Design of Voltage Controller of DVR based on DSP)

  • 이원선;김수곤;임병국;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.566-569
    • /
    • 2004
  • The recent growth in the use of impactive and nonlinear loads, electronic devices sensitive to power quality has caused many power quality problems. Recently, in power system, not only the reliability of the power supply but also the DVR(Dynamic Voltage Restorer) are being studied more and more. The DVR is a series compensator which can instantaneously compensate a voltage variation in supply side, and is a more effective than a existing UPS(Uninterruptible Power Supply) which can be only used in limited range of loads such as single load. Hence, in this paper, a study of inverter side L-C filter output Voltage for DVR is discussed.

  • PDF

다이나믹 UPS의 성능시험을 위한 순시전압 변동 발생기 (Instantaneous Voltage Disturbance Generator for the Performance Test of Dynamic UPS)

  • 김중원;이기수;변우열;노의철;김인동;전태원;김흥근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1254-1256
    • /
    • 2004
  • This paper deals with a novel 3-phase power quality disturbance generator. The proposed generator can be applied to the performance that of custom power devices. Voltage sag, swell and outage are provided by the generator. The control scheme for the disturbance generation is simple, and hardware setup is cost effective, compared with conventional scheme. The operating principle of the generator is described and the usefulness verified through simulation with 10KVA power rating.

  • PDF

DSP에 의한 PWM 인버터의 Real-Time Digital 제어 (Real-Time Digital Control of PWM Inverter Empolyed DSP)

  • 박가우;민완기;최재호;최성률
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.724-727
    • /
    • 1993
  • This paper is presented real-time digital control techniques of the PWM inverter for UPS. This proposed system is based on instantaneous digital control scheme which is empolyed double dead beat control and prediction method. Especially, to supply the load current from the inverter without the computation delay, the predictive methods are used to generate the load current signal. From the simulation and experimental results, it is shown that presented scheme has good performance such as very low THD of the output voltage, and good dynamic response under the nonlinear load. The experimental implementation of the system is estabilished by using the TMS320C25 DSP.

  • PDF

액셀러레이터 프로그램과 스타트업 성과의 구조적 관계에서 동적역량의 영향 (The Influence of Dynamic Capabilities on the Structural Relationship between Accelerator Programs and Startup Performance)

  • 최보라 ;동학림
    • 벤처혁신연구
    • /
    • 제6권1호
    • /
    • pp.95-114
    • /
    • 2023
  • 창업기업의 5년내 생존율이 30% 내외인 점을 감안하면 스타트업의 지속가능성은 중요한 이슈로 부상하고 있다. 최근들어 스타트업을 지원하는 액셀러레이터의 역할이 강조되고 있다. 이에 본 연구에서는 액셀러레이터들이 스타트업에 제공하는 서비스 중 멘토링서비스, 교육서비스, 펀딩서비스, 네트워킹서비스가 스타트업의 동적역량을 거쳐 스타트업 성과에 영향을 미치는 구조적인 관계를 실증 분석하고자 했다. 이를 위해 액셀러레이터 프로그램 서비스를 받은 경험이 있는 스타트업 CEO 및 임원진을 대상으로 2023년 2월에 설문 조사를 실시하였다. 이중 유효한 238개를 분석 대상으로 삼았다. 실증분석은 Amos 24를 활용한 구조방정식으로 했다. 실증 분석 결과는 다음과 같다. 액셀러레이터 프로그램 중 멘토링서비스, 교육서비스, 펀딩서비스 및 네트워킹서비스는 스타트업 동적 역량에 유의한 정(+)의 영향을 미쳤다. 액셀러레이터 프로그램 하위 요소가 스타트업 동적역량에 미치는 영향력의 순위는 네트워킹서비스, 멘토링서비스, 펀딩서비스, 교육서비스 순으로 나타났다. 또한 스타트업의 동적 역량은 스타트업 창업 성과에 유의한 정(+)의 영향을 미치는 것으로 나타났다. 한편, 스타트업의 동적 역량은 멘토링서비스, 교육서비스, 펀딩서비스, 네트워킹서비스와 스타트업 창업성과간 유의한 매개 역할을 하는 것으로 나타났다. 스타트업에 있어서 동적 역량은 매우 중요한 요소이며, 액셀러레이터 프로그램은 이러한 동적 역량을 매개로 해서 창업 성과에 유의한 영향을 미치다는 점은 학술적으로나 실무적으로나 나름 의미있는 시사점이라 할 수 있을 것이다.

한국 신용카드기업의 역량과 차별성 : 신용카드기업 종사자에 대한 Q 분석결과를 중심으로 (The Core Capabilities and Differences of Korean Credit Card Companies: Based on Q Analysis Results of Employers in Credit Card Companies)

  • 고형면
    • 한국조사연구학회지:조사연구
    • /
    • 제9권2호
    • /
    • pp.85-118
    • /
    • 2008
  • 이 연구는 한국의 신용카드기얼 종사자들에게 Q 방법을 접목시켜, 해당 기업의 역량과 차별성을 검증하려는 목적 하에 이루어졌다. 사회과학 내에서 제도의 진화에 초점을 두는 이론 진영은, 기업 구성원들의 가장 일상적인 활동 속에 기업의 경쟁력이 배태돼(embedded) 있음을 강조한다. 즉 암묵적이면서도 비공식화된 방식으로 이루어지는 매일의 학습, 의사소통, 의사결정이 조직의 동태적 역량(dynamic capabilities)을 결정짓는다. 기업 구성원들의 내적, 잠재적 활동을 객관적으로 측정하고자 이 연구는, 계량화가 어려운 인간의 질적.주관적 속성들을 수치화시키는데 장점을 지닌 Q 방법을 활용한다. 분석결과에 의하면, 다수의 응답자들이 기업역량과 경쟁력의 질적 수준이 향상되어야 함을 강조한다. 하지만 응답자들 중 은행계의 경우 주로 성장 지향적 정책과 기업발전을 중시하며, 기업계는 정책으로부터의 독립성을 강조하나 기업조직 우선적 사고에 갇혀 있다. 2000년 이후 고착화된 한국 신용카드산업의 주기적인 부침은, 신용카드기업의 역량(경쟁력), 산업환경, 정책의 개선에 대한 기업현장의 기대나 요구가 충분히 반영되지 않은 것과 결코 무관하지 않다.

  • PDF