• Title/Summary/Keyword: Dynamic UPS

Search Result 67, Processing Time 0.026 seconds

Single-Chip Microprocessor Based Instantaneous Voltage Control of Inverter for UPS (Single-Chip 마이크로프로세서를 이용한 UPS용 인버터의 순시전압제어)

  • 최재호;박세현;민완기;김재식
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.6
    • /
    • pp.49-57
    • /
    • 1992
  • This paper proposes a Intel 8097 single-chip microprocessor based instantaneous voltage control scheme of inverter for UPS(Uninterruptible Power Supply). There microprocessors are used to control the output voltage and frequency of the inverter, the synchronization with by-pass, and the switching of the static switch. And the status and operating conditions of UPS systems is monitored by micro processor. The inverter output voltage is controlled instantaneously with a double regulation loop so that it has very good dynamic response for the varying loads or nonlinear loads as a rectifier. And also, the software and hardware of control system is described. From simulation and experimental results, it is shown that the proposed scheme has very good performance.

  • PDF

Sag Voltage Compensator using Diode Rectifier and Series Inverter (다이오드 정류기와 인버터를 이용한 순간 전압 강하 보상기)

  • 이준기;박덕희;김희중;한병문;소용철
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.448-451
    • /
    • 1999
  • This paper describes controller development for a dynamic voltage compensator using a shunt diode converter and series inverter. The control system was designed using 1/4 period integrator and vector relationship between the supply voltage and load voltage. A simulation model and scaled hardware model were developed for analyzing performance of the controller and the whole system. Both results confirm that the dynamic compensator can restore the load voltage under the fault of the distribution system.

  • PDF

Internal Model Control of UPS Inverter with Robustness of Calculation Time Delay and Parameter Variation (연산지연시간과 파라미터 변동에 강인한 UPS 인버터의 내부모델제어)

  • Park, Jee-Ho;Keh, Joong-Eup;Kim, Dong-Wan;An, Young-Joo;Park, Han-Seok;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.4
    • /
    • pp.175-185
    • /
    • 2002
  • In this paper, a new fully digital current control method of UPS inverter, which is based on an internal model control, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The internal model controller is adopted to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. That is, the average current of filter capacitor is been exactly equal to the reference current with a time lag of two sampling intervals. Therefore, this method has an essentially overshoot free reference-to-output response with a minimum possible rise time. The effectiveness of the proposed control system has been verified by the simulation and experimental respectively. From the simulation and experimental results, the proposed system is achieved the robust characteristics to the calculation time delay and parameter variation as well as very fast dynamic performance, thus it can be effectively applied to the power supply for the critical load.

Design and Stability Analysis of a Fuzzy Adaptive SMC System for Three-Phase UPS Inverter

  • Naheem, Khawar;Choi, Young-Sik;Mwasilu, Francis;Choi, Han Ho;Jung, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.704-711
    • /
    • 2014
  • This paper proposes a combined fuzzy adaptive sliding-mode voltage controller (FASVC) for a three-phase UPS inverter. The proposed FASVC encapsulates two control terms: a fuzzy adaptive compensation control term, which solves the problem of parameter uncertainties, and a sliding-mode feedback control term, which stabilizes the error dynamics of the system. To extract precise load current information, the proposed method uses a conventional load current observer instead of current sensors. In addition, the stability of the proposed control scheme is fully guaranteed by using the Lyapunov stability theory. It is shown that the proposed FASVC can attain excellent voltage regulation features such as a fast dynamic response, low total harmonic distortion (THD), and a small steady-state error under sudden load disturbances, nonlinear loads, and unbalanced loads in the existence of the parameter uncertainties. Finally, experimental results are obtained from a prototype 1 kVA three-phase UPS inverter system via a TMS320F28335 DSP. A comparison of these results with those obtained from a conventional sliding-mode controller (SMC) confirms the superior transient and steady-state performances of the proposed control technique.

A Study on Strategic Alliances between Terrestrial Broadcasters and Content Start-ups with a Focus on KBS LABS (지상파방송사와 콘텐츠 스타트업의 전략적 제휴에 관한 연구: 'KBS LABS'를 중심으로)

  • Park, Hee Bong
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.5
    • /
    • pp.644-657
    • /
    • 2019
  • This study examines the types of strategic alliances formed between terrestrial broadcasters and content start-ups, their resource inter-dependence and the dynamic evolution of their relationship through a case study of KBS Labs, a strategic alliance between KBS and content start-ups. Mergers, acquisitions and strategic alliances sought by large media companies or strategic alliances made only between disparate providers in broadcasting and telecommunications industries are now actively pursued by traditional media and start-ups. The alliances between traditional media and start-ups are beneficial to both parties: traditional media can quickly implement start-ups' innovative ideas and business models and start-ups can tap into not only vast amounts of content being created by or in the archives of traditional media but also their capital, office space and reputation. Therefore, the case study of KBS Labs will help draw out important implications for motivating strategic alliances between traditional media and start-ups. To this end, the resource-based view and the evolutionary theory of the firm are adopted to explore the characteristics and development process of the KBS Labs business.

A Study on the control method of DYNAMIC UPS (다이나믹 무정전전원장치 제어 방법)

  • Kwak, C.H.;Park, K.S.;Chung, C.H.;Kwon, D.K.;Park, J.S.;Byun, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.10-13
    • /
    • 2004
  • 현재 고도의 정보화 사회에서는 계측기 및 정보통신기기의 발달로 정확한 신뢰성이 요구되고 있으나, 정전이나 순간적 전압강하와 같은 전력장애의 요인은 산업에 막대한 영향을 미치므로 경제적 손실 등의 치명적인 피해를 준다. 이 문제를 해결하는 방안으로 무정전전원장치(UPS : Uninterruptible Power Supply)의 필요성이 요구되는 현실입니다. 그러나 UPS을 사용함으로써 문제점도 야기되고 있는 주요 원인은 밧데리의 불량과 교체에 따른 환경적인 문제가 대두되고 있는 헌상입니다. 문제점을 해소하기 위한 방안으로 축전지없이 정전을 보상하는 방식을 채택시 축전지 설치장소 확보, 운영관리, 교체 등에 따른 경제적 손실을 크게 줄일 수 있으며, 또한 축전지 미사용으로 인한 환경공해 문제가 해결 할 수 있다. 이러한 문제점을 해결하고자 PS 장비의 효율성과 신뢰성 모두가 향상되고 또한 장비의 연간 유지보수 비용 절감 및 환경 공해로부터 문제를 해소 할 수 있는 다이나믹 무정전전원장치(Dynamic Uninterruptible Power Supply)의 필요성이 대두되고 있는 실정입니다.

  • PDF

New 3-Phase Phase Locked Loop(PLL) Strategy Haying Frequency Limiter and Anti-windup Suitable to Uninterruptible Power Supply (무정전전원장치에 적합한 주파수 제한기와 안티 와인드업을 가지는 새로운 3상 전원각 정보 추출 방식)

  • Ji, Jun-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1086-1091
    • /
    • 2006
  • In this paper an advanced PLL strategy suitable to UPS, compared with conventional PLL strategy using the positive sequence component extracted from source voltages, is suggested. Frequency limiter and anti-windup are added to conventional PI controller in suggested PLL strategy. Basic operational principle of suggested PLL is same as that of conventional PLL, but the difference between two strategies is that the suggested PLL can limit the change of frequency in constant range because of inclusion of frequency limiter. Compute. simulation was carried fer the DVR(dynamic voltage restorer) compensating voltage to examine the difference between conventional PLL strategy and the suggested PLL strategy limiting frequency. And the results clearly demonstrate the effectiveness of the suggested PLL strategy for UPS.

  • PDF

우주급 경통 열-흡습 설계

  • Lee, Deog-Gyu
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.108-113
    • /
    • 2005
  • Strucutral and hygrothermal analysis for a composite tube is carried out in this study, that provides critical parameters for the design of a highly dimensionally stable space telescope. Carpet plots for laminate effective engineering constants are generated and used for the best tube lay-ups with high elastic modulus and highly insensitive to thermal and moisture expansion, which is essential for maintaining optical alignment of opto-mechanical system under random force applied during a launch campaign and orbital thermal load. Despace in the longitudinal direction under hygrothermal load of the tubes constructed with the selected lay-ups is calculated for the validation of lay-up designs on the dimensionalstability. Dynamic analysis is also carried out to feature the resonant behaviour. A zig-zag triangular element accurately representing through thickness stress variations for laminated structures is developed in this study and incorporated into the structural and hygrothermal analysis.

  • PDF

Real Time Digital Control of PWM Inverter for Uninterruptible Power Supply(UPS) application (무정전 전원공급장치 적용을 위한 PWM 인버터의 Digital 실시간 제어)

  • Min, Wan-Ki;Lee, Sang-Hun;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.56-60
    • /
    • 1999
  • This paper presents the high performance real time control system of PWM inverter for uninterruptible power supply(UPS). This system is based on a digital control scheme which calculates the pulse widths of the inverter switches for the next sampling time in digital signal processor(DSP). A PI compensator is used to eliminate the voltage error caused by the difference between the actual values of LC filter and those designed. Double regulation loops which are the inner current loop and the outer voltage loop are used to make the transient response time reduce in load disturbance and nonlinear load. This method makes it possible to obtain better response in comparison to conventional digital control system. The proposed scheme provides good performance such as stable operation, low THD of the output voltage, and good dynamic response for load variations and nonlinear load.

  • PDF

Sag-Swell Generator for the test of 3-phase Dynamic UPS (3상 다이나믹 UPS의 성능 시험을 위한 Sag-Swell 발생기)

  • Kim, J.W.;Lee, K.S.;Byun, W.Y.;Nho, E.C.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.514-517
    • /
    • 2004
  • This paper describes a new 3 phase Sag-Swell generator for the test of custom power devices such as UPS, DVR, DSTATCOM, SSTS, etc. The proposed scheme has good features of simple structure, high reliability wide range of sag and swell variation, It can also generate voltage outage. The control scheme for the generation is simple. The operation principle of the proposed scheme is described and verified through simulations.

  • PDF