• Title/Summary/Keyword: Dual-energy computed tomography (DECT)

Search Result 18, Processing Time 0.013 seconds

Effect of Total Collimation Width on Relative Electron Density, Effective Atomic Number, and Stopping Power Ratio Acquired by Dual-Layer Dual-Energy Computed Tomography

  • Jung, Seongmoon;Kim, Bitbyeol;Yoon, Euntaek;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.165-171
    • /
    • 2021
  • Purpose: This study aimed to evaluate the effect of collimator width on effective atomic number (EAN), relative electron density (RED), and stopping power ratio (SPR) measured by dual-layer dual-energy computed tomography (DL-DECT). Methods: CIRS electron density calibration phantoms with two different arrangements of material plugs were scanned by DL-DECT with two different collimator widths. The first phantom included two dense bone plugs, while the second excluded dense bone plugs. The collimator widths selected were 64 mm×0.625 mm for wider collimators and 16 mm×0.625 mm for narrow collimators. The scanning parameters were 120 kVp, 0.33 second gantry rotation, 3 mm slice thickness, B reconstruction filter, and spectral level 4. An image analysis portal system provided by a computed tomography (CT) manufacturer was used to derive the EAN and RED of the phantoms from the combination of low energy and high energy CT images. The EAN and RED were compared between the images scanned using the two different collimation widths. Results: The CT images with the wider collimation width generated more severe artifacts, particularly with high-density material (i.e., dense bone). RED and EAN for tissues (excluding lung and bones) with the wider collimation width showed significant relative differences compared to the theoretical value (4.5% for RED and 20.6% for EAN), while those with the narrow collimation width were closer to the theoretical value of each material (2.2% for EAN and 2.3% for RED). Scanning with narrow collimation width increased the accuracy of SPR estimation even with high-density bone plugs in the phantom. Conclusions: The effect of CT collimation width on EAN, RED, and SPR measured by DL-DECT was evaluated. In order to improve the accuracy of the measured EAN, RED, and SPR by DL-DECT, CT scanning should be performed using narrow collimation widths.

Analysis of Attenuation Differences According to Radiolucent and Radiopague Materials : Based on DECT (Dual Energy Computed Tomography) (방사선 투과 및 불투과성 물질에 따른 감약 차이의 분석 : DECT 검사 중심으로)

  • Jang, Hyon-Chol;Kim, Yoon-Shin;Kim, Hyeon-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1584-1589
    • /
    • 2014
  • This study analyzed CT values of radiolucent and radiopaque materials by energy region after selecting radiolucent and radiopaque materials at random using GE's DECT((Dual Energy Com-puted Tomography) at S University Hospital located in Gyeonggi-province from July through August in 2013. Besides, it drew out the most analogous energy region to the value of 120kVp CT, which is applied to existing SECT(Single Energy Computed Tomography), by utilizing the analysis method of CT values and tried to find out the most useful and appropriate materials when contrast was applied within visible area in clinical application. As a result, there was little decrease of CT value after 90KeV in the case of materials with low density and high moisture content such as normal saline, methyl-cellulose and gels used in ultra-sonic waves test; energy does not influence much on materials with extremely low or high density such as air and contrast medium; methyl-cellulose and gels used in ultra-sonic waves test are considered to be the most useful materials for clinical applications.

Dual-Energy CT for Pulmonary Embolism: Current and Evolving Clinical Applications

  • Yoo Jin Hong;Jina Shim;Sang Min Lee;Dong Jin Im;Jin Hur
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1555-1568
    • /
    • 2021
  • Pulmonary embolism (PE) is a potentially fatal disease if the diagnosis or treatment is delayed. Currently, multidetector computed tomography (MDCT) is considered the standard imaging method for diagnosing PE. Dual-energy CT (DECT) has the advantages of MDCT and can provide functional information for patients with PE. The aim of this review is to present the potential clinical applications of DECT in PE, focusing on the diagnosis and risk stratification of PE.

Prognostic Value of Dual-Energy CT-Based Iodine Quantification versus Conventional CT in Acute Pulmonary Embolism: A Propensity-Match Analysis

  • Dong Jin Im;Jin Hur;Kyunghwa Han;Young Joo Suh;Yoo Jin Hong;Hye-Jeong Lee;Young Jin Kim;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • v.21 no.9
    • /
    • pp.1095-1103
    • /
    • 2020
  • Objective: The present study aimed to investigate whether quantitative dual-energy computed tomography (DECT) parameters offer an incremental risk stratification benefit over the CT ventricular diameter ratio in patients with acute pulmonary embolism (PE) by using propensity score analysis. Materials and Methods: This study was conducted on 480 patients with acute PE who underwent CT pulmonary angiography (CTPA) or DECT pulmonary angiography (DE CT-PA). This propensity-matched study population included 240 patients with acute PE each in the CTPA and DECT groups. Altogether, 260 (54.1%) patients were men, and the mean age was 64.9 years (64.9 ± 13.5 years). The primary endpoint was all-cause death within 30 days. The Cox proportional hazards regression model was used to identify associations between CT parameters and outcomes and to identify potential predictors. Concordance (C) statistics were used to compare the prognoses between the two groups. Results: In both CTPA and DECT groups, right to left ventricle diameter ratio ≥ 1 was associated with an increased risk of all-cause death within 30 days (hazard ratio: 3.707, p < 0.001 and 5.573, p < 0.001, respectively). However, C-statistics showed no statistically significant difference between the CTPA and DECT groups for predicting death within 30 days (C-statistics: 0.759 vs. 0.819, p = 0.117). Conclusion: Quantitative measurement of lung perfusion defect volume by DECT had no added benefit over CT ventricular diameter ratio for predicting all-cause death within 30 days.

Comparison of Estimated and Measured Doses of Dual-energy Computed Tomography (Dual-energy 컴퓨터단층촬영에서 장비 제공선량과 측정선량 비교)

  • Kim, Yung-Kyoon;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.405-411
    • /
    • 2018
  • We will provide basic data on the evaluation of patient dose in terms of DECT quality control by comparing the equipment-provided dose with the measured dose according to the configuration method of the X-ray generator by the manufacturer of the dual-energy CT unit. For computed tomography (CT) equipment, Discovery 750HD, Aquilion ONE GENESIS Edition, and Somatom Definition Flash were used. The $CTDI_{vol}$ value was measured by inserting the Unfors Xi ion chamber into a 32 cm PMMA acryl Phantom. The results of estimated $CTDI_{vol}$ DECT and measured $CTDI_{vol}$ showed that the dose difference between DECT 80 + 140 kVp of G company was at least 0.51% and -1.90% max, and measured $CTDI_{vol}$ was slightly lower (p<0.05). The difference of 80 + 140 kVp of S company was the minimum of 5.84% and the maximum of 7.52% (p<0.05). The measured $CTDI_{vol}$ was less than estimated $CTDI_{vol}$. The C company's 80 + 135 kVp showed a difference of at least 7.58% and a maximum of 13.58% (P<0.05), and all of measured $CTDI_{vol}$ was less. The linearity of exposure dose for all DECT equipment was very linearly reflected with $R^2$ being 0.97 or above, and the measured dose of the ionization chamber was less than the predicted dose of the monitor.

Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors

  • Shota Tanoue;Takeshi Nakaura;Yasunori Nagayama;Hiroyuki Uetani;Osamu Ikeda;Yasuyuki Yamashita
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.951-958
    • /
    • 2021
  • Objective: To evaluate the usefulness of virtual monochromatic images (VMIs) obtained using dual-layer dual-energy CT (DL-DECT) for evaluating brain tumors. Materials and Methods: This retrospective study included 32 patients with brain tumors who had undergone non-contrast head CT using DL-DECT. Among them, 15 had glioblastoma (GBM), 7 had malignant lymphoma, 5 had high-grade glioma other than GBM, 3 had low-grade glioma, and 2 had metastatic tumors. Conventional polychromatic images and VMIs (40-200 keV at 10 keV intervals) were generated. We compared CT attenuation, image noise, contrast, and contrast-to-noise ratio (CNR) between tumor and white matter (WM) or grey matter (GM) between VMIs showing the highest CNR (optimized VMI) and conventional CT images using the paired t test. Two radiologists subjectively assessed the contrast, margin, noise, artifact, and diagnostic confidence of optimized VMIs and conventional images on a 4-point scale. Results: The image noise of VMIs at all energy levels tested was significantly lower than that of conventional CT images (p < 0.05). The 40-keV VMIs yielded the best CNR. Furthermore, both contrast and CNR between the tumor and WM were significantly higher in the 40 keV images than in the conventional CT images (p < 0.001); however, the contrast and CNR between tumor and GM were not significantly different (p = 0.47 and p = 0.31, respectively). The subjective scores assigned to contrast, margin, and diagnostic confidence were significantly higher for 40 keV images than for conventional CT images (p < 0.01). Conclusion: In head CT for patients with brain tumors, compared with conventional CT images, 40 keV VMIs from DL-DECT yielded superior tumor contrast and diagnostic confidence, especially for brain tumors located in the WM.

Classification of Urinary Stone into Uric Acid & Non-uric Acid by Dual-Energy (이중에너지 전산화단층촬영을 이용한 요로결석의 성분 분석에 관한 연구)

  • Myung-Jin Jung;Sung-Gil Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.835-841
    • /
    • 2023
  • The aim of this study is to evaluate the diagnostic ability of dual-energy computed tomography (DECT) for Composition determination of urinary stones in phantom model. Seventeen cases with urinary stones who underwent DECT were enrolled in the study. The composition of the urinary stones was extracted from the seventeen patients were analyzed with DECT in phantom model with fresh pork. The volume scan method using Dual-energy software was used and the scanned image sets were assessed. All 17 urinary stones of the phantom model were analyzed according to the stone composition using DE stone Analysis were divided into uric acid stones (n=6, 35.29%) and non-uric acid stones (n=11, 64.71%). These urinary stones were pathologically confirmed. The mean attenuation values of uric acid stones at 135 kV, 100 kV and 80 kV was 348.87 ± 166.37 HU, 345.33 ± 151.18 HU and 337.94 ± 172.77 HU, respectively. The mean attenuation values of non-uric acid stones at 135 kV, 100 kV and 80 kV was 551.93 ± 297.09 HU, 747.04 ± 351.31 HU and 958.19 ± 424.72 HU, respectively. At 80 kV, uric acid stones and non-uric acid stones showed significant difference in the attenuation values(P<0.05). The attenuation values of DECT could differentiate the compositions of urinary stones between uric acid and non-uric acid stones at 80 kV in phantom model.

Optimization of Energy Modulation Filter for Dual Energy CBCT Using Geant4 Monte-Carlo Simulation

  • Ju, Eun Bin;Ahn, So Hyun;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.125-130
    • /
    • 2016
  • Dual energy computed tomography (DECT) is used to classify two materials and quantify the mass density of each material in the human body. An energy modulation filter based DECT could acquire two images, which are generated by the low- and high-energy photon spectra, in one scan, with one tube and detector. In the case of DECT using the energy modulation filter, the filter should perform the optimization process for the type of materials and thicknesses for generating two photon spectra. In this study, Geant4 Monte-Carlo simulation toolkit was used to execute the optimization process for determining the property of the energy modulation filter. In the process, various materials used for the energy modulation filter are copper (Cu, $8.96g/cm^3$), niobium (Nb, $8.57g/cm^3$), stannum (Sn, $7.31g/cm^3$), gold (Au, $19.32g/cm^3$), and lead (Pb, $11.34g/cm^3$). The thickness of the modulation filter varied from 0.1 mm to 1.0 mm. To evaluate the overlap region of the low- and high-energy spectrum, Geant4 Monte-Carlo simulation is used. The variation of the photon flux and the mean energy of photon spectrum that passes through the energy modulation filter are evaluated. In the primary photon spectrum of 80 kVp, the optimal modulation filter is a 0.1 mm lead filter that can acquire the same mean energy of 140 kVp photon spectrum. The lead filter of 0.1 mm based dual energy CBCT is required to increase the tube current 4.37 times than the original tube current owing to the 77.1% attenuation in the filter.

Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT (간의 단일선원 Twin Beam과 이중선원 이중에너지 전산화단층촬영의 비조영증강 영상과 가상 비조영증강 영상의 비교 연구)

  • Jeong Sub Lee;Guk Myung Choi;Bong Soo Kim;Su Yeon Ko;Kyung Ryeol Lee;Jeong Jae Kim;Doo Ri Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.170-184
    • /
    • 2023
  • Purpose To assess the magnitude of differences between attenuation values of the true non-contrast image (TNC) and virtual non-contrast image (VNC) derived from twin-beam dual-energy CT (tbDECT) and dual-source DECT (dsDECT). Materials and Methods This retrospective study included 62 patients who underwent liver dynamic DECT with tbDECT (n = 32) or dsDECT (n = 30). Arterial VNC (AVNC), portal VNC (PVNC), and delayed VNC (DVNC) were reconstructed using multiphasic DECT. Attenuation values of multiple intra-abdominal organs (n = 11) on TNCs were subsequently compared to those on multiphasic VNCs. Further, we investigated the percentage of cases with an absolute difference between TNC and VNC of ≤ 10 Hounsfield units (HU). Results For the mean attenuation values of TNC and VNC, 33 items for each DECT were compared according to the multiphasic VNCs and organs. More than half of the comparison items for each DECT showed significant differences (tbDECT 17/33; dsDECT 19/33; Bonferroni correction p < 0.0167). The percentage of cases with an absolute difference ≤ 10 HU was 56.7%, 69.2%, and 78.6% in AVNC, PVNC, and DVNC in tbDECT, respectively, and 70.5%, 78%, and 78% in dsDECT, respectively. Conclusion VNCs derived from the two DECTs were insufficient to replace TNCs because of the considerable difference in attenuation values.

Detection of Monosodium Urate Crystal of Hand and Wrist in Suspected Gouty Arthritis Patients on Dual-Energy CT and Relationship with Serum Urate Level (손과 손목의 통풍관절염에서 이중에너지 CT를 이용한 요산나트륨 결정 검출과 혈중 요산 농도와의 관계)

  • Hana Choi;Jeongah Ryu;Seunghun Lee;Yeo Ju Kim;Soyoung Bang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.212-225
    • /
    • 2023
  • Purpose We retrospectively investigated the characteristics of patients with monosodium urate (MSU) deposits of the hand and wrist on dual-energy CT (DECT) compared to those without. We also attempted to determine the pattern of MSU distribution in DECT. Materials and Methods In total, 93 patients were included who had undergone DECT for evaluation of the hand or wrist pain under the clinical impression of gouty arthritis. The total volume of MSU deposits on DECT was calculated and the pattern of MSU distribution on DECT was analyzed. Also, the level of the serum urate at the time of DECT and the highest level of the serum urate of the patients were obtained from their records and the relationship between MSU and serum urate level was evaluated. Results The range of the volume of MSU deposits on DECT was 0.01-16.11 cm3 (average: 1.07 cm3). The average level of serum urate was significantly higher in the MSU positive group than that in the MSU negative group. MSU deposits were most frequently observed in the wrists followed by fingers and digitorum tendons. Conclusion On DECT, MSU deposits were most frequently detected in the wrist and related with high serum urate level.