• Title/Summary/Keyword: Dual-cure

검색결과 55건 처리시간 0.022초

Evaluation of shear bond strength between dual cure resin cement and zirconia ceramic after thermocycling treatment

  • Lee, Jung-Jin;Kang, Cheol-Kyun;Oh, Ju-Won;Seo, Jae-Min;Park, Ju-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE. This study was performed to evaluate shear bond strength (SBS) between three dual-cured resin cements and silica coated zirconia, before and after thermocycling treatment. MATERIALS AND METHODS. Sixty specimens were cut in $15{\times}2.75mm$ discs using zirconia. After air blasting of $50{\mu}m$ alumina, samples were prepared by tribochemical silica coating with $Rocatec^{TM}$ plus. The specimens were divided into three groups according to the dual-cure resin cement used: (1) Calibra silane+$Calibra^{(R)}$, (2) Monobond S+$Multilink^{(R)}$ N and (3) ESPN sil+$RelyX^{TM}$ Unicem Clicker. After the resin cement was bonded to the zirconia using a Teflon mold, photopolymerization was carried out. Only 10 specimens in each group were thermocycled 6,000 times. Depending on thermocycling treatment, each group was divided into two subgroups (n=10) and SBS was measured by applying force at the speed of 1 mm/min using a universal testing machine. To find out the differences in SBS according to the types of cements and thermocycling using the SPSS, two-way ANOVA was conducted and post-hoc analysis was performed by Turkey's test. RESULTS. In non-thermal aged groups, SBS of Multilink group (M1) was higher than that of Calibra (C1) and Unicem (U1) group (P<.05). Moreover, even after thermocycling treatment, SBS of Multilink group (M2) was higher than the other groups (C2 and U2). All three cements showed lower SBS after the thermocycling than before the treatments. But Multilink and Unicem had a significant difference (P<.05). CONCLUSION. In this experiment, Multilink showed the highest SBS before and after thermocycling. Also, bond strengths of all three cements decreased after thermocycling.

이원중합형 코어 축조용 복합레진의 결합강도에 대한 NaOCI의 영향에 대한 연구 (Influence of Sodium Hypochlorite on Bond Strength of Dual-cured Core Build-up Resin Composite)

  • 이준봉;박종덕;권수미;유미경;이광원
    • 구강회복응용과학지
    • /
    • 제23권4호
    • /
    • pp.283-292
    • /
    • 2007
  • Two-step or one-step bonding systems generally inhibit curing process of dual-cured core build-up resin composite for their adhesive acidity. In addition this dual-cured core build-up resin composite can be applied to dentin of pulp chamber and root at the time that complete the endodontic treatment. The purpose of this investigation was to determine the influence of sodium hypochlorite on rnicrotensile bond strength of dual-cured core build-up resin composite. Extracted human molars were horizontally sectioned with 1mm thickness using low speed diamond saw. After the sectioned specimens were divided into 8 groups, adhesive systems (Clearfil SE-Bond, Prime&Bond NT[2-step, 1-step], Adper Prompt L-Pop) were then applied with or without sodium hypochlorite pretreatment. The treated specimen was filled with dual-cured core build-up resin composite (Luxacore, DMG corp., German). Then light cured for 40 seconds and soaked in $37^{\circ}C$ water bath for 24 hours. After the treated specimen was grinded with 1mm width and measured rnicrotensile bond strength by testing machine. Additionally 8 teeth were prepared for SEM evaluation. The results were as follows. : NaOCl treated groups generally had lower rnicrotensile bond strength but did not show any difference statistically except Adper Prompt L-Pop. When the teeth were treated by NaOCl, though the difference of applied adhesive system, it had no statistically significant difference within the NaOCl treated groups except the relation of between ClearFil SE-Bond adhesive system and Adper Prompt L-Pop adhesive system. In the SEM evaluation, NaOCl treated groups presented relatively long resin tags and incomplete hybrid layer formation generally.

아르곤레이저를 이용한 레진인레이 하부의 레진 시멘트 및 광중합형 복합레진 중합 (THE MICROHARDNESS OF RESTORATIVE COMPOSITE AND DUAL-CURED COMPOSITE CEMENT UNDER THE PRECURED COMPOSITE OVERLAY)

  • 박성호;이창규
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.109-115
    • /
    • 2000
  • This study was designed to evaluate the microhardness of restorative composite resin and dual-cured composite resin cement which were light cured through the 1.5mm thickness composite overlay. For restorative materials, Z100 and Tetric Ceram were used. For dual cured composite cements, Variolink II((VL II) of three consistency (low, high, ultra high) were used. To determine the optimal microhardness of Z100, Tetric Ceram and Variolink II, each material was packed into the 1mm thickness teflon mold without composite overlay and light cured for 60 seconds. Then the microhardnesses of each sample were measured, averaged and regarded as optimal hardness of each material. To evaluate the microhardness of restorative composite resin and dual-cured composite resin cement which were light cured through the 1.5mm thickness composite overlay, the composites were packed into 1mm thickness teflon mold, coverd with celluloid strip, and then precured composite overlay which was made of Targis(Ivoclar/Vivadent, Liechtenstein) was positioned. 2 types of visible light curing machine, the power density of one of which was 400$mW/cm^2$ and the other was 900$mW/cm^2$, and one type of argon laser were used to cure the restorative composite and dual cured cement. For each group, 10 sample were assigned. The light curing tip was positioned over the composite overlay and light cured for 1min., 2min. or 3min with visible light curing machine or 15sec, 30 sec, 45sec, and 60 sec with argon laser. The Vickers hardnesses of upper and lower surface of Z100, Tetric Ceram, and 3 types of VL II cement were measured. When the 900 $mW/cm^2$ curing light was used, 2min. was needed for optimal curing of Z100 and Tetric Ceram. Variolink II did not be cured optimally even though the curing time was extended to 3min. When 400$mW/cm^2$ curing light was used, 3min. was necessary for Z100, whereas 3min. was not enough for Tetric Ceram. Variolink II was not cured optimally even though the curing time was extended to 3min. When argon laser was used, Z100, Tetric Ceram and Variolink II were not cured optimally in 60 seconds.

  • PDF

접착제의 접착변수가 레진계 근관충전제의 근단밀폐효과에 미치는 영향 (The effects of total-etch, wet-bonding, and light-curing of adhesive on the apical seal of a resin-based root canal filling system)

  • 류원일;손원준;백승호;이인한;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제36권5호
    • /
    • pp.385-396
    • /
    • 2011
  • 연구목적: 본 연구는 치근벽의 전처리 개념과 접착제의 중합방법이 레진계 근관충전제의 치근단 밀폐능에 미치는 영향을 평가하였다. 연구 재료 및 방법: 3가지 다른 접착변수를 조합하여 충전한 Resilon-RealSeal 시스템의 근단미세누출을 색소침투법을 이용하여 통상의 가타퍼쳐 충전과 비교하였다. 실험군은 자가부식형 RealSeal primer와 이중중합형 RealSeal sealer를 이용하여 Resilon 충전한 SEDC군, 산부식없이 Scotchbond Multi-Purpose primer를 적용한 후 접착제는 광중합하고 Resilon을 충전한 NELC군, 및 Scotchbond Multi-Purpose의 접착강화제와 접착제를 total etch/wet bonding과 광중합의 술식을 정확하게 지켜서 Resilon을 충전한 TELC군으로 구분하였다. 대조군(GPCS)에서는 통상의 AH26 plus sealer를 사용하여 가타퍼쳐를 충전 하였다. 결과: 치아장축방향의 색소침투는 TELC군에서 GPCS군과 SEDC군에 비해 유의하게 작았다(Kruskal-Wallis test, p < 0.05). 횡단면의 미세누출 점수도 TELC군이 근첨으로부터 2 - 5 mm의 범위에서 다른 군에 비해 유의하게 낮았다(Kruskal-Wallis test, p < 0.05). 결론: 레진계 근관충전제를 사용 시에는, 자가부식형 전처리제와 이중중합형 sealer보다는, total etch/wet bonding 개념과 적절한 광중합을 도모하는 전처리제 및 접착제의 사용이 치근단 미세누출을 감소시키므로 추천된다.

접착레진의 부가도포가 레진 시멘트의 결합강도에 미치는 영향에 대한 연구 (The Effect of Bonding Resin on Bond Strength of Dual-Cure Resin Cements)

  • 김덕수;박상혁;최기운;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제32권5호
    • /
    • pp.426-436
    • /
    • 2007
  • 본 연구에서는 접착레진의 부가적인 도포가 레진 시멘트의 결합강도에 미치는 영향을 연구하였다. One-Step Plus와 Choice, Single Bond와 Rely X ARC, One-Up Bond F와 Bistite II DC를 사용하였고 접착레진으로 D/E Bonding resin과 Pre-Bond Resin을 선택하였다. 적용 및 광중합 유무에 따라 12개의 군을 설정하였다. 제 3대구치의 건전한 상아질 면에 간접 복합레진 수복물을 제작하여 접착을 시행하고$1\;{\times}\;1\;mm^2$의 시편을 만들어 미세인장강도를 측정하였다. 또한 투과전자현미경으로 접착계면을 관찰하였다. 그리하여 다음과 같은 결론을 얻을 수 있었다. 1. Single Bond와 Rely X ARC, 그리고 One-Step Plus와 Choice를 조합하고 광중합을 시행한 군에서, 접착 레진을 부가적으로 도포할 경우 미세인장강도가 증가하였다. 2. One-Up Bond F와 Bistite II DC를 조합한 군에서 접착레진의 부가적인 도포에 의한 미세인장강도의 차이는 나타나지 않았다. 3. 광중합을 시행한 군들 중, One-Step Plus와 Choice를 조합한 군이 다른 군보다 높은 미세인장결합강도를 보였다. 4. 자가중합만을 시행한 군간에는 접착레진의 부가적인 도포에 의한 차이가 나타나지 않았다. 투과전자현미경 관찰을 시행하여 광중합을 시행하고 접착레진을 부가적으로 도포한 실험군에서 미세누출이 감소하고 접착층의 두께가 증가한 것을 확인할 수 있었다. 본 연구결과 완전산부식 상아질 접착제와 이중중합 레진 시멘트를 사용할 경우 부가적인 접착레진의 도포가 임상적으로 유용할 수 있다는 사실을 확인할 수 있었다.

Comparative Analysis of the Physical and Biochemical Properties of Light-cure Resin-modified Pulp Capping Materials

  • Tae Gyeom Kim;Jongsoo Kim;Joonhaeng Lee;Jisun Shin;Mi Ran Han;Jongbin Kim;Yujin Kim;Jae Hee Park
    • 대한소아치과학회지
    • /
    • 제51권2호
    • /
    • pp.149-164
    • /
    • 2024
  • This study compared the solubility, water absorption, dimensional stability, release of various ions (hydroxyl, calcium, sulfur, strontium, and silicon), and cytotoxicity of light-cured resin-modified pulp-capping materials. Resin-modified calcium hydroxide (Ultra-blendTM plus, UBP), light-cured resin-modified calcium silicate (TheraCal LCTM, TLC), and dual-cure resin-modified calcium silicate (TheraCal PTTM, TPT) were used. Each material was polymerized; solubility, 24-hour water absorption, and 30- day dimensional stability experiments were conducted to test its physical properties. Solubility was assessed according to the ISO 6876 standard, and 24 hours of water absorption, 30 days of dimensional stability were assessed by referring to the previous protocol respectively. Eluates at 3 and 24 hours and on 7, 14, and 28 days were analyzed according to the ISO 10993-12 standard. And the pH, Ion-releasing ability, cell proliferation rate, and cell viability were assessed using the eluates to evaluate biochemical characteristics. pH was measured with a pH meter and Ion-releasing ability was assessed using inductively coupled plasma atomic emission spectrometry (ICP-AES). Cell proliferation rate and cell viability were assessed using human dental pulp cells (hDPCs). The former was assessed by an absorbance assay using the CCK-8 solution, and the latter was assessed by Live and Dead staining. TPT exhibited lower solubility and water absorption than TLC. UBP and TPT demonstrated higher stability than TLC. The release of sulfur, strontium, calcium, and hydroxyl ions was higher for TLC and TPT than for UBP. The 28-day release of hydroxyl and silicon ions was similar for TLC and TPT. TLC alone exhibited a lower cell proliferation rate compared to the control group at a dilution ratio of 1 : 2 in cell proliferation and dead cells from Live and Dead assay evaluation. Thus, when using light-cure resin-modified pulp-capping materials, calcium silicate-based materials can be considered alternatives to calcium hydroxide-based materials. Moreover, when comparing physical and biochemical properties, TPT could be prioritized over TLC as the first choice.

이중상 구조를 가진 보강성 충전제의 물리적 특성 연구 (A Study on the Physical Properties of Reinforcing Fillers with Dual Phase Structure)

  • 이석;박남국
    • 공업화학
    • /
    • 제9권4호
    • /
    • pp.608-613
    • /
    • 1998
  • 본 연구의 목적은 순수 카본블랙과 이중상 구조의 카본블랙 (DPCB)이 함유되어 있는 고무조성물의 물리적 특성에 대하여 조사하였다. DPCB는 FT-IR분석결과 1100~1200 파장에서 실리카 표면에 존재하는 Si-O 피크를 나타냈다. DPCB와 유기 실란커프링제 (Si69)를 함유하는 고무조성물의 가황속도는 순수 카본블랙을 함유한 고무조성물에 비해 지연되었다. Si69를 함유한 DPCB의 300% 모듈러스와 상호작용계수 ($a_f$)는 순수 카본블랙보다 높게 나타났으며, 내마모특성 지표인 피코 무게감소량은 일정하게 나타났다. DPCB의 $0^{\circ}C$에서의 tan ${\delta}$는 DPCB 50 phr 기준 실란커플링제를 2.0% 사용한 수준에서 순수 카본블랙보다 우수하였으며, $60^{\circ}C$에서의 tan ${\delta}$는 실란커프링제의 사용량이 증가 할수륵 감소하였다. 결국 본 연구에 사용된 DPCB는 일정한 마모저항을 유지하면서 회전저항을 개선하는데 적합하다고 생각한다.

  • PDF

카본 블랙/유기화 클레이로 보강된 SBR 나노 복합재료: 모폴로지와 기계적 물성 (Properties of SBR Nanocomposites Reinforced with Organoclay/Carbon Black Dual Phase Fillers)

  • 강병석;김원호
    • Elastomers and Composites
    • /
    • 제42권1호
    • /
    • pp.9-19
    • /
    • 2007
  • 본 연구에서는 카본블랙과 유기화 클레이(C18-MMT) 로 보강된 SBR 나노 복합재료를 라텍스법(latex method)으로 제조하였다. 필러의 함량은 50 phr로 고정하였으며, 카본 블랙/C18-MMT의 함량비를 50/0, 49/1, 48/2, 47/3, 45/5, 44/6, 40/10 phr로 정하고 함량비에 따른 가황 특성 및 기계적 물성을 비교하였다. 각 컴파운드의 가황 특성 및 기계적 물성을 비교 평가한 결과 carbon black(49phr)/C18-MMT(1phr) 컴파운드가 ODR에서 가장 높은 최대 토크 값을 나타내었으며, 높은 인장 강도 및 모듈러스, 인열 에너지를 나타내었다. 이러한 기계적 물성 증가는 클레이의 박리 정도 및 분산도의 향상으로 인한 C18-MMT의 우수한 보강 효과 때문이라고 판단된다.

생약복합제제(生藥複合製劑)의 품질관리(品質管理)에 관(關)한 연구(硏究)(제1보)(第1報) -TLC Scanner에 의(依)한 삼요탕(三拗湯)의 품질관리(品質管理)- (Studies on the Quality Control Method of Crude Drug Preparations (I) -Studies on the Quality Control by the TLC Profiles Analysis of ‘Samyo-Tang’-)

  • 홍남두;김종우;김남재;손정곤
    • 생약학회지
    • /
    • 제12권3호
    • /
    • pp.119-124
    • /
    • 1981
  • In our country, in order to cure diseases, a large number of crude drug preparations has been available. Nevertheless, the development of crude drug preparations have been inhibited, because the quality control is not completed so far. Therefore, we have eontinued on studing the quality control method by Zig-zag TLC. profile analysis. The water extract of 'Samyo-Tang' and componental crude drug (Glycyrrhizae Radix, Ephedrae Herba, Armenicae Semen) were developed on Silica gel $60F_{254}\;plate\;(E.\;Merck)$ useing elution solvent. The developed plate were examined useing Dual Wavelength Zig-zag Scanner (Shimadzu). According to the results of the experiment, it could be summarized as follow: 1) Original patterns of TLC profiles of 'Samyo-Tang' componental crude drug and mixing two crude drugs of 'Samyo-Tang' were observed. 2) Original patterns TLC profile of each extract after spraying with 2% ninhydrine were observed. 3) In the extract of addition and subtraction of Ephedrae Herba, peak area of Rf 0.48 and Rf 0.60 were varied quantitatively.

  • PDF

비닐하우스 내에서의 발수발유가공 부직포와 복합가공 부직포로 만든 농약 방호복의 착용성능 (Wear Performance of Pesticide Protective Clothing in Vinyl Plastic Hothouse made with Water-Oil Repellent and Dual Functional Finished Nonwoven Fabrics)

  • 최종명;조정숙;조길수
    • 한국의류학회지
    • /
    • 제20권2호
    • /
    • pp.350-361
    • /
    • 1996
  • The objectives of this study mere 1) to investigate whether the different nonwoven fabric types influenced on the objective and subjective wear performances of the experimental pesticide protective pants, 2) to detect whether the different finishes treated to the nonwoven fabrics influenced on the objective and subjective wear performances of the experimental pants, and 3) to detect the relationships between objective wear performances and subjective wear sensation. Three types of nonwoven fabrics (T (Tyvek$\textregistered$), 5 (Sontara$\textregistered$) and K (Kimlon$\textregistered$)) were used as test specimens. By pad-dry.cure method, each of the specimen was treated with fluorocarbon compound for water-oil repellent finish (Tw, Sw, Kw). And each of specimen was treated with organic silicon quarternary ammonium salts and then treated with fluorocabon compound for dual functional finish (76, 50, Kd). Using the three water-oil repellent finished fabrics and the three dual functional finished fabrics, six experimental protective pants (Cl (Tw), C2 (Sw), C3 (Kw), C4 (76), C5 (56), C6 (Kd)) were made according to the same pattern suggested by the Rual Guidance Office. The wear trials of experimental pesticide protective pants were performed in a conditioned vinyl plastic hothouse ($30\pm1^{\circ}C$, $70\pm5%$R.H., 0.25m/sec air velocity). The measurements of skin temperature, microclimate temperature and humidity on the subjects were obtained by the themohygromenter. The subjective wear sensations were measured using previously developed thermal, humidity and overall comfort scales. The results obtained from this study were as follows: 1) There were siginificant differences among nonwoven fabric types on the objective and subjective wear performances, therefore, the skin temperature, microclimate temperature and humidity of subjects who wore the experimental pants made with Sontara were siginificantly lower than those who wore the others. And, the experimental pants made with Sontara were assessed as more comfortable than the others in terms of the subjective thermal, humidity and overall wear sensations. 2) There were no significant differences between two finish types on the objective and subjective wear Performances. 3) The microclimate humidity on the thigh was highly correlated with the overall subjective comfort sensations and the next highly correlated one was the mean skin temperature. That is, the higher the microclimate humidity and the mean skin temperature, the higher the overall subjective comfort sensation ratings which mean the overall subjective sensation was very uncomfortable.

  • PDF