• 제목/요약/키워드: Dual Units

검색결과 67건 처리시간 0.027초

A Broadband Microstrip Array Antenna for 3G Smart Antenna System Testbed

  • Rashid, Zainol Abidin Abdul;Islam, Mohammad Tariqul;Jiunn, Ng Kok
    • 정보통신설비학회논문지
    • /
    • 제7권1호
    • /
    • pp.41-58
    • /
    • 2007
  • A compact and broadband $4{\times}1$ array antenna was developed for 3G smart antenna system testbed. The $4{\times}1$ uniform linear array antenna was designed to operate at 1.885 to 2.2GHz with a total bandwidth of 315MHz. The array elements were based on the novel broadband L-probe fed inverted hybrid E-H (LIEH) shaped microstrip patch, which offers 22% size reduction to the conventional rectangular microstrip patch antenna. For steering the antenna beam, a commercial variable attenuator (KAT1D04SA002), a variable phase shifter (KPH350SC00) with four units each, and the corporate 4-ways Wilkinson power divider which was fabricated in-house were integrated to form the beamforming feed network. The developed antenna has an impedance bandwidth of 17.32% ($VSWR{\leq}1.5$), 21.78% ($VSWR{\leq}2$) with respect to center frequency 2.02GHz and with an achievable gain of 11.9dBi. The design antenna offer a broadband, compact and mobile solution for a 3G smart antenna testbed to fully characterized the IMT-2000 radio specifications and system performances.

  • PDF

80μW/MHz 0.68V Ultra Low-Power Variation-Tolerant Superscalar Dual-Core Application Processor

  • Kwon, Youngsu;Lee, Jae-Jin;Shin, Kyoung-Seon;Han, Jin-Ho;Byun, Kyung-Jin;Eum, Nak-Woong
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권2호
    • /
    • pp.71-77
    • /
    • 2015
  • Upcoming ground-breaking applications for always-on tiny interconnected devices steadily demand two-fold features of processor cores: aggressively low power consumption and enhanced performance. We propose implementation of a novel superscalar low-power processor core with a low supply voltage. The core implements intra-core low-power microarchitecture with minimal performance degradation in instruction fetch, branch prediction, scheduling, and execution units. The inter-core lockstep not only detects malfunctions during low-voltage operation but also carries out software-based recovery. The chip incorporates a pair of cores, high-speed memory, and peripheral interfaces to be implemented with a 65nm node. The processor core consumes only 24mW at 350MHz and 0.68V, resulting in power efficiency of $80{\mu}W/MHz$. The operating frequency of the core reaches 850MHz at 1.2V.

Inverted RTK system and its applications in Japan

  • Kanzaki, Masayuki
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 International Symposium on GPS/GNSS Vol.1
    • /
    • pp.455-458
    • /
    • 2006
  • The Real Time Kinematic (RTK) technique is the most productive and accurate GPS positioning method today, as it can be determinate position within few centimeters instantly. This method is widely used for applications such as surveying, structure monitoring and machine guidance etc. In order to perform RTK processing for large scale systems (i.e. precise vehicle monitoring with many rovers), many expensive RTK receivers and same number of bidirectional communication units have to be installed to collect observation data communicate with the reference site and monitor its RTK solutions. Moreover, if applications require remote control or apply sensing instruments, we have to install computers at each rover. To limit expense and complexity of system management with a large number of rovers, we have developed server based RTK processing platform to share RTK function for all rovers. The system can be process many GPS stations with a single personal computer. we have also developed a specialized dual frequency GPS receiver unit without on-board RTK processing capability to reduce receiver cost in order to demonstrate the advantage of our server based RTK platform. This paper describes the concept of our server based RTK platform and specialized GPS receiver unit with existing applications in Japan.

  • PDF

Robust Design of Pulse Oximeter Using Dynamic Control and Motion Artifact Detection Algorithms

  • Cho, Jung Hyun;Kim, Jong Cheol;Yoon, Gil Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1780-1787
    • /
    • 2014
  • Arterial oxygen saturation ($SpO_2$) monitoring for newborns requires special attention in neonatal intensive care units (NICUs). Newborns have very low photo-plethysmogram (PPG) amplitudes and their body movements are difficult to contain. Hardware design and its associated signal processing algorithms should be robust enough so that faulty measurements can be avoided. In this study, improved designs were implemented to deal with low perfusion, motion artifact, and the influence of ambient light. Dynamic range was increased by using different LED intensities and a feedback system. To minimize the effects of motion artifact and to discard other unqualified data, four additional algorithms were used, which were based on dual-trace detection, continuity of DC level, morphology of PPG, and simultaneity check of $SpO_2$. Our $SpO_2$ system was tested with newborns with normal respiration in the NICU. Our system provided fast, real-time responses and 100% artifact detection was accomplished under 84% of $SpO_2$.

A High Efficiency Controller IC for LLC Resonant Converter in 0.35 μm BCD

  • Hong, Seong-Wha;Kim, Hong-Jin;Park, Hyung-Gu;Park, Joon-Sung;Pu, Young-Gun;Lee, Kang-Yoon
    • Journal of Power Electronics
    • /
    • 제11권3호
    • /
    • pp.271-278
    • /
    • 2011
  • This paper presents a LLC resonant controller IC for secondary side control without external active devices to achieve low profile and low cost LED back light units. A gate driving transformer is adopted to isolate the primary side and the secondary side instead of an opto-coupler. A new integrated dimming circuitry is proposed to improve the dynamic current control characteristic and the current density of a LED for the brightness modulation of a large screen LCD. A dual-slope clock generator is proposed to overcome the frequency error due to the under shoot in conventional approaches. This chip is fabricated using 0.35 ${\mu}m$ BCD technology and the die size is $2{\times}2\;mm^2$. The frequency range of the clock generator is from 50 kHz to 500 kHz and the range of the dead time is from 50 ns to 2.2 ${\mu}s$. The efficiency of the LED driving circuit is 97 % and the current consumption is 40 mA for a 100 kHz operation frequency from a 15 V supply voltage.

Solvent-Induced Photoemissions of High-Energy Chromophores of Conjugated Polymer MEH-PPV: Role of Conformational Disorder

  • Traiphol, Rakchart;Charoenthai, Nipaphat
    • Macromolecular Research
    • /
    • 제16권3호
    • /
    • pp.224-230
    • /
    • 2008
  • This study examined the photoemission behaviors of isolated chains of poly[2-methoxy, 5-(2'-ethylhexyloxy)-1,4-phenylenevinylene](MEH-PPV) dispersed in various solvents including dichloromethane, chloroform and tetrahydrofuran(THF). A change in polymer-solvent interactions in these solutions caused the MEH-PPV chains to adopt different local conformations, which in turn affected their radiative de-excitation pathways. For the polymer in dichloromethane and chloroform, in which the conjugated chains are relatively extended, photoemission occurs mostly at the long chromophores with lowest HOMO-LUMO energy gap. Their emission spectra showed a main peak at ${\sim}560\;nm$. Dual photoemission of high- and low-energy chromophores was observed when the conjugated chains were forced to partially collapse in a poor solvent THF. Novel high-energy peaks and a typical low-energy peak were detected at ${\sim}414\;nm$ and ${\sim}554\;nm$, respectively. The observation of the high-energy peaks indicates significant suppression of the intrachain energy transfer process, which was attributed to the increase in conformational disorder in the partially collapsed coils. An analysis of the excitation spectra suggests that the high-energy peaks belong to short chromophores constituting of one or two repeat units. This study systematically investigated the effects of polymer concentration, temperature and single bond defects along the backbone on the photoemission of the high-energy chromophores.

Effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy CT

  • Jeong, Dae-Kyo;Lee, Sam-Sun;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제49권4호
    • /
    • pp.273-279
    • /
    • 2019
  • Purpose: This study was performed to investigate the effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield unit (HU) values of hydroxyapatite (HA) in virtual monochromatic images (VMIs) obtained with dual-energy computed tomography (DECT)(Siemens Healthineers, Erlangen, Germany). Materials and Methods: A bone density calibration phantom with 3 HA inserts of different densities(CTWATER®; 0, 100, and 200 mg of HA/㎤) was scanned using a twin-beam DECT scanner at 120 kVp with tube rotation times of 0.5 and 1.0 seconds. The VMIs were reconstructed by changing the energy level (with options of 40 keV, 70 keV, and 140 keV). In order to investigate the impact of the reconstruction kernel, virtual monochromatic images were reconstructed after changing the kernel from body regular 40 (Br40) to head regular 40 (Hr40) in the reconstruction phase. The mean HU value was measured by placing a circular region of interests (ROIs) in the middle of each insert obtained from the VMIs. The HU values were compared with regard to energy level, reconstruction kernel, and tube rotation time. Results: Hydroxyapatite density was strongly correlated with HU values(correlation coefficient=0.678, P<0.05). For the HA 100 and 200 inserts, HU decreased significantly at increased energy levels(correlation coefficient= -0.538, P<0.05) but increased by 70 HU when using Hr40 rather than Br40 (correlation coefficient=0.158, P<0.05). The tube rotation time did not significantly affect the HU(P>0.05). Conclusion: The HU values of hydroxyapatite were strongly correlated with hydroxyapatite density and energy level in VMIs obtained with DECT.

A COMPARATIVE STUDY OF THE 1-PIECE AND 2-PIECE CONICAL ABUTMENT JOINT: THE STRENGTH AND THE FATIGUE RESISTANCE

  • Kwon, Taek-Ka;Yang, Jae-Ho;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.780-786
    • /
    • 2007
  • Statement of problem. The performance and maintenance of implant-supported prostheses are primarily dependent upon load transmission both at the bone-to-implant interface and within the implant-abutment-prosthesis complex. The design of the interface between components has been shown to have a profound influence on the stability of screw joints. Purpose. The Purpose of this study was to compare the strength and the fatigue resistance of 1-piece and 2-piece abutment connected to oral implant, utilizing an internal conical interface. Material and methods. Twenty $Implatium^{(R)}$ tapered implants were embedded to the top of the fixture in acrylic resin blocks. Ten $Combi^{(R)}$(1-piece) and $Dual^{(R)}$(2-piece) abutments of the same dimension were assembled to the implant, respectively. The assembled units were mounted in a testing machine. A load was applied perpendicular to the long axis of the assemblies and the loading points was at the distance of 7mm from the block surface. Half of 1-piece and 2-piece abutment-implant units were tested for the evaluation of the bending strength, and the others were cyclically loaded for the evaluation of the fatigue resistance until plastic deformation occurred. Nonparametric statistical analysis was performed for the results. Results. Mean plastic and maximum bending moment were $1,900{\pm}18Nmm,\;3,609{\pm}106Nmm$ for the 1-piece abutment, and $1,250{\pm}31Nmm,\;2,688{\pm}166Nmm$ for the 2-piece abutment, respectively. Mean cycles and standard deviation when implant-abutment joint showed a first plastic deformation were $238,610{\pm}44,891$. cycles for the 1-piece abutment and $9,476{\pm}3,541$ cycles for the 2-piece abutment. A 1-piece abutment showed significantly higher value than a 2-piece abutment in the first plastic bending moment (p<.05), maximum bending moment (p<.05) and fatigue strength (p<.05). Conclusion. Both 1-piece and 2-piece conical abutment had high strength and fatigue resistance and this suggests long-term durability without mechanical complication. However, the 1-piece conical abutment was more stable than the 2-piece conical abutment in the strength and the fatigue resistance.

Machine Learning Model to Predict Osteoporotic Spine with Hounsfield Units on Lumbar Computed Tomography

  • Nam, Kyoung Hyup;Seo, Il;Kim, Dong Hwan;Lee, Jae Il;Choi, Byung Kwan;Han, In Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.442-449
    • /
    • 2019
  • Objective : Bone mineral density (BMD) is an important consideration during fusion surgery. Although dual X-ray absorptiometry is considered as the gold standard for assessing BMD, quantitative computed tomography (QCT) provides more accurate data in spine osteoporosis. However, QCT has the disadvantage of additional radiation hazard and cost. The present study was to demonstrate the utility of artificial intelligence and machine learning algorithm for assessing osteoporosis using Hounsfield units (HU) of preoperative lumbar CT coupling with data of QCT. Methods : We reviewed 70 patients undergoing both QCT and conventional lumbar CT for spine surgery. The T-scores of 198 lumbar vertebra was assessed in QCT and the HU of vertebral body at the same level were measured in conventional CT by the picture archiving and communication system (PACS) system. A multiple regression algorithm was applied to predict the T-score using three independent variables (age, sex, and HU of vertebral body on conventional CT) coupling with T-score of QCT. Next, a logistic regression algorithm was applied to predict osteoporotic or non-osteoporotic vertebra. The Tensor flow and Python were used as the machine learning tools. The Tensor flow user interface developed in our institute was used for easy code generation. Results : The predictive model with multiple regression algorithm estimated similar T-scores with data of QCT. HU demonstrates the similar results as QCT without the discordance in only one non-osteoporotic vertebra that indicated osteoporosis. From the training set, the predictive model classified the lumbar vertebra into two groups (osteoporotic vs. non-osteoporotic spine) with 88.0% accuracy. In a test set of 40 vertebrae, classification accuracy was 92.5% when the learning rate was 0.0001 (precision, 0.939; recall, 0.969; F1 score, 0.954; area under the curve, 0.900). Conclusion : This study is a simple machine learning model applicable in the spine research field. The machine learning model can predict the T-score and osteoporotic vertebrae solely by measuring the HU of conventional CT, and this would help spine surgeons not to under-estimate the osteoporotic spine preoperatively. If applied to a bigger data set, we believe the predictive accuracy of our model will further increase. We propose that machine learning is an important modality of the medical research field.

광대역 위성 통신/방송용 삼중 대역 이동형 안테나 시스템 설계에 관한 연구 (A Study on Mobile Antenna System Design with Tri-band Operation for Broadband Satellite Communications and DBS Reception)

  • 엄순영;정영배;손성호;윤재승;전순익
    • 한국전자파학회논문지
    • /
    • 제17권5호
    • /
    • pp.461-475
    • /
    • 2006
  • 본 논문은 Ka/K 통신 대역 및 Ku 방송 대역에서 동작하는 무궁화 3호 정지 궤도 위성을 이용하여 화상 전화, 인터넷과 같은 위성 멀티미디어 및 방송 서비스를 제공하는 이동체 탑재형 안테나 시스템 설계에 관한 것이다. 앙각 방향으로 팬 빔 특성을 갖는 안테나 시스템의 방사부는 준-오프셋 이중 성형 반사판과 삼중 대역 급전기로 구성된다. 또한, 삼중 대역 급전기는 돌출 유전체 막대를 이용한 Ka/K 이중 대역 급전기 및 원형 편파기, 직교 모드 변환기 그리고 Ku 대역 원형 편파 급전 배열로 구성된다. 특히, Ka/K 이중 대역 원형 편파기는 제작이 용이한 comb 구조를 사용하여 구현되었다. Ku 대역 급전 배열은 이동시 위성을 고속으로 추적하기 위하여 전자 빔을 형성할 수 있는 $2{\times}2$ 능동 위상 배열 구조를 갖는다. 그리고, 급전 배열에서 $90^{\circ}$ 하이브리드 결합기를 이용하여 원형 편파를 생성하는 4개의 방사 소자들을 $90^{\circ}$씩 회전하여 배열함으로써 원형 편파 특성을 개선하였다. Ku 대역 전자 빔을 생성하는 4개의 빔 성형 채널은 출력에서 주 빔 채널 및 추적 빔 채널로 구분되며, 각 채널의 내부 구성 유니트들의 잡음 온도 기여도를 바탕으로 채널 잡음 온도 특성을 분석하였다. 제작된 안테나 시스템으로부터 측정된 Ka 송신 채널의 $P_{1dBc}$ 출력은 34.1 dBm 이상, K/Ku 수신 채널의 잡음 지수는 각각 2.4 dB 및 1.5 dB 이하의 전기적인 성능들을 보여주었다. 안테나 시스템은 근접 전계 측정 방법을 사용하여 삼중 대역에서의 주 편파 및 교차 편파 방사 패턴들을 측정하였다. 특히, Ku 대역의 방사 패턴 측정은 급전 배열들의 독립 여기에 의한 부분 방사 패턴들을 측정하여 각 능동 채널들의 초기 위상들을 보정한 후 이루어졌다. 안테나 시스템의 Ka/K/Ku 대역에서 측정된 안테나 이득은 각각 39.6 dBi, 37.5 dBi, 29.6 dBi 이상이었으며, 그리고 Ka 대역 송신 EIRP는 43.7 dBW 이상, K/Ku 대역 수신 감도 G/T는 각각 13.2 dB/K와 7.12 dB/K 이상의 우수한 시스템 성능들을 보여주었다.