• Title/Summary/Keyword: Double line

Search Result 776, Processing Time 0.03 seconds

A Study on The Search of Geodesic Line and Cuting Pattern Generation of Membrane Structures (막 구조물의 측지선 탐색과 재단도 작성에 관한 연구)

  • Jeon Jin-Hyung;Jeong Eul-Seok;Shon Su-Deok;Kim Seung-Deog
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.325-332
    • /
    • 2006
  • Membrane structures, a kind of lightweight soft structural system, are used for spatial structures. The design procedure of membrane structures are needed to do shape finding, stress-deformation analysis and cutting pattern generation, because the material property has strong axial stiffness, but little bending stiffness. The problem of cutting pattern is highly varied in their size, curvature and material stiffness. So, the approximation inherent in cutting pattern generation methods is quite different. Therefore the ordinary computer software of structural analysis & design is not suitable for membrane structures. In this study, we develop the program for cutting pattern generation using geodesic line, and investigate the result of example's cutting pattern in detail.

  • PDF

Comparison on Characteristics between air-gap type and gapless In transmission LA (송전선로 피뢰기 적용 및 외부 갭형과 갭레스형의 동작특성 비교)

  • You, Hee-Young;Kim, Jong-Chae;Kim, Byeong-Heon;Park, Yoon-Seok;Lee, Bong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.347-348
    • /
    • 2008
  • This paper presents the use of Line Surge Arresters on 154kV double circuit lines. The ouatge rate which is highly related to the tower footing resistance is showed during the last a few year. The general methods that have been adopted at lines also are introduced. Lightning performance of lines without and with line surge arrester is studied and compared. The characteristics between air-gap type and gapless type LSA also compared. Line surge arrester installation strategy is presented.

  • PDF

The Editions of the Hsin-Ching-Fu-Chu with the Postscripts of Toegye, published between 16th and 17th Centuries. (십육세기.십칠세기 간행 "심경부주" 유후논본의 판본-퇴계서지의 연구 기사)

  • 윤병태
    • Journal of Korean Library and Information Science Society
    • /
    • v.6
    • /
    • pp.141-158
    • /
    • 1979
  • This is a bibliographical study of the editions of the Hsin-Ching-Fu-Chu published between 16th and 17th centuries, together with the postscript written by Yi-Hwang. For this research, 14 kinds of the editions are studied, the results of which are analyzed as follows; (1) The publishing date: 2kinds of the editions are published before 1969, and 12 kinds after 1569 when Yi-Hwng died. (2) The method of publishing: 2 kinds were printed by movable types, the others by block-plates. (3) The publishing place: 12 kinds were put out in Korea, and 2 kinds in Japan. The publishing places of 6 kinds of Korean editions are known. They are Muncheon-Gun, Gyoseokwan, etc.., For other 6 kinds of Korean editions, the publishing places are unknown. (4) 6 kinds of editions were printed in the double-border-line style, and consisted of 10 lines, each line having 17 characters. Such forms are regarded as the traces of the printing style of Gyoseokwan. One kind of editions was printed with single-border-line.

  • PDF

An Effective Utilization of Regenerative Power According to the Output Voltage of Substations in the DC Electric Railways (직류전기철도 시스템에 있어서의 변전소 송출전압에 따른 회생전력유효이용)

  • Kim, Yang-Mo
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.2
    • /
    • pp.149-156
    • /
    • 1990
  • In DC electric railway systems, the feeding currrnt is not permitted to flow backward in almost all the substations and the pantograph voltages at the regenerating cars rise extremely by the voltage drop of the resistance of the feeder line. In order to prevent the overrise of the pantograph voltage in power regenerating cars, the squeezing circuits for the regenerative current are equipped and this leads to double losses, which are an extra worn-out of the brake-shoes and an ineffective use of regenerative power. In this study, the insertion of resistors in the feeder line system is proposed as a possible method for the effective utilization of the regenerative power in the electric railways. Also it is investigated how the output voltages of substations affect the effective use of regenertive capability. The investigation results show that the energy savings and the reduction of the worn-out of the brake-shoe can be achieved at the same time by the insertion of resistors in the feeder line system.

  • PDF

3D Deinterlacing Algorithm Based on Wide Sparse Vector Correlations

  • Kim, Yeong-Taeg
    • Journal of Broadcast Engineering
    • /
    • v.1 no.1
    • /
    • pp.44-54
    • /
    • 1996
  • In this paper, we propose a new 3-D deinterlacing algorithm based on wide sparse vector correlations and a vertical edge based motion detection algorithm. which is an extension of the deinterlacing algorithm proposed in [10. llJ by the authors. The prooised algorithm is developed mainly for the format conversion problem encountered in current HDTV system, but can also be aplicable to the double scan conversion problesm frequently encountered in ths NTSC systems. By exploiting the edge oriented spatial interpolation based on the wide vector correlations, visually annoying artifiacts caused by interlacing such as a serrate line. line crawling, a line flicker, and a large area flicker can be remarkably reduced since the use of the wide vectors increases the range of the edge orientations that can be detected, and by exploiting sparse vectors correlations the HjW complexity for realizing the algorithm in applications cam be significantly simplified. Simulations are provided indicating thet the proposed algorithm results in a high performance comparable to the performance of the deinterlacing algorithm. based on the wide vector correlations.

  • PDF

Insulation coordination of 765 KV double circuit transmission line (765 KV 2 회선(回線) 송전선(送電線) 절연협조(絶緣協助))

  • Kim, Jeong-Boo;Min, Suk-Won;Lee, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.774-777
    • /
    • 1988
  • This paper covers the insulation coordination of 765 KV transmission line in Korea Electric Power Corporation. The design for the lightning, switching surge, and contamination was conducted to increase the reliability of 765 KV line. The authors have used the result of a limited Westinghouse ANACOM swiching surge study of the Korea Electric Corporation's 765 KV Expansion plan. The study investigated the switching surge overvoltage distribution and maximum switching overvoltage when relosing 765 KV lines. They used the technical data of the suspension insulator for the contamination design, which was available from a foreign insulator manufacture. From this paper, the authors find out that the contamination design dominates to determine the number of insulator and the SOV design dominates the air clearance in the tower. Afterwards the authors will confirm this design by Demonstration Test with Korea Electro-technology Research Institute.

  • PDF

An EMTDC Analysis for Ground Faults with a Superconducting Fault Current Limiter (초전도 한류기를 포함한 계통의 지락사고에 대한 EMTDC 해석)

  • Choe, Hyo-Sang;Hyeon, Ok-Bae;Go, Tae-Guk
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.4
    • /
    • pp.161-166
    • /
    • 1999
  • We have performed an EMTDC simulation for the current limiting effects of a superconducting fault current limiter (SFCL). The fault currents in the 154 kV transmission line between the arbitrary S1 and S2 substations increased up to 39 kA during the single and double line-to-ground faults, respectively. The SFCL in the transmission line is sufficient.

  • PDF

Deformation by line heating for thin plate (박판 곡직을 위한 선 가열 시 변형 특성에 관한 연구)

  • Park, Jung-Gu;Jang, Gyeong-Bok;Jo, Si-Hun;Jang, Tae-Won
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.282-284
    • /
    • 2005
  • The line heating methods is very widely employed to correct deformation of thin plate structures. In this study, evaluation was carried out on the temperature distribution of line heating methods using FEA and practical experiments. In FEA, heat input model was established using Tsuji's double Gaussian heat input mode. This model was verified by comparing with experimental data. Thermo elasto-plastic analysis was performed using commercial FE code, MSC/MARC. Transverse shrinkage and angular distortion were measured using 3D measuring apparatus. Based on these results, a simplified analysis method is applied by using equivalent loading method.

  • PDF

The extended narrow-line region kinematics of 3 Type-2 QSOs revealed by the VLTVIMOS IFU spectra

  • Cho, Hojin;Woo, Jonghak;Bennert, Vardha N.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.88.2-88.2
    • /
    • 2012
  • We present kinematic properties of the narrow-line region in three type-2 QSOs at z~0.35, using 2-D spectra obtained with the VIMOS integral field unit spectrograph at the Very Large Telescope. One of the objects shows a line-of-sight velocity shift of the [OIII] and $H{\beta}$ lines up to 40km/s on a 15 kpc scale, which can be interpreted as either outflow or rotation. The outflow scenario is supported by the presence of blue wings and a radio structure showing lobes in the same direction. Another object features double-peaked emission lines which can be decomposed into two velocity components. Its Hubble Space Telescope image shows two nuclei separated by ~0.2"(~1kpc), implying this may be a binary AGN.

  • PDF

On-Line Type Dynamic Voltage Restorer System by Improvement of EDLC's energy utilization ratio (EDLC의 Energy이용 향상에 의한 On-Line type Dynamic Voltage Restorer System)

  • Shon, Jin-Geun;Park, Jong-Chan;Seo, Il-Dong;Jeon, Hee-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1099-1101
    • /
    • 2007
  • In this paper, a study has been performed for development of dynamic voltage restorer(DVR) system using EDLC (Electric Double Layer Capacitor) to solve voltage sags which are considered the dominant disturbances affecting power quality. With the prolific use of semiconductor devices in electrical equipment, modern-day loads are becoming increasingly sensitive to the sags and the disturbances prove to be costly to industries. As a technology-driven custom power installation, the Dynamic Voltage Restorer (DVR) is recognized to be most effective equipment that can be used to counter the voltage sag problem. Hence, this paper proposes the high-performance optimal design of On-Line type DVR system which can efficiently compensate the instantaneous voltage sag and instantaneous interruption of the utility voltage source.

  • PDF