• 제목/요약/키워드: Double Fourier

검색결과 148건 처리시간 0.023초

2개 매개변수를 갖는 탄성지반위에 놓인 복합재료 적층판의 점탄성적 휨, 진동 좌굴해석 (Viscoelastic Bending, Vibration and Buckling Analysis of Laminated Composite Plates on Two-parameter Elastic Foundation)

  • 한성천;장석윤
    • 한국강구조학회 논문집
    • /
    • 제13권5호
    • /
    • pp.443-455
    • /
    • 2001
  • 전단 층을 갖는 2개 매개변수 탄성지반 위에 놓인 복합재료 적층판에서 휨 진동 및 좌굴해석을 위해 에너지 방법을 사용해 탄성해를 구하였다. 복합재료 적층판의 점탄성 해석은 유사-탄성방법을 사용해 탄성해를 구하였다. 전단에 의한 효과는 3창 전단변형이론을 적용하여 고려하였다. 유도된 식들을 검증하기 위해 LUSAS 프로그램에 의한 탄성지반위에 놓인 이방성 판의 처짐과 비교하였다. 점탄성 휨 진동 및 좌굴해석에 관한 수치해석결과들은 적층순서, 적층 수 재료 비등방성과 전단지반계수 등에 따른 효과를 보여 준다.

  • PDF

Estimation of Displacements Using the Transformed Response in Time and Frequency Domain

  • Jung, Beom-Seok
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • 제6권1호
    • /
    • pp.44-50
    • /
    • 2003
  • If the accelerometers are used in measuring the response, the absolute values of the velocity and displacement are not usually obtainable because their initial values are not accounted for in the integration of the acceleration response. A new dynamic response conversion algorithm of both the time domain and the frequency domain is proposed for the problem in estimating the displacement data by defining the transformed responses. In this algorithm, the displacement response can be obtained from the measured acceleration records by integration without requiring the knowledge of the initial velocity and displacement information. The applicability of the technique is tested by an example problem using the real bridge's superstructure under several cases of moving load. In the response conversion procedure of the frequency domain, the identified response according to the frequency can be estimated by changing over the limits of integration. If the reliability of the identified responses is ensured, it is expected that the proposed method for estimating the impact factor can be useful in the bridge's dynamic test. This method can be useful in those practical cases when the direct measurement of the displacement is difficult as in the dynamic studies of huge structure.

  • PDF

전달함수와 진동응답 측정에 의한 원심펌프에서의 유체력 특성에 관한 연구 (A Study on the Hydraulic Excitation Forces Using Transfer Function and Operational Measured Data for the Centrifugal Pump)

  • 최복록;박진무;김광은
    • 대한기계학회논문집A
    • /
    • 제24권8호
    • /
    • pp.1931-1939
    • /
    • 2000
  • Operating excitation forces of the linear vibratory system are normally determined by direct measurement techniques using load cells, strain gauges, etc. But, hydraulic forces of the rotating turbomachinery such as centrifugal pumps are exerted on an impeller due to asymmety of the flow by the interaction between pump impeller and volute. So, investigations of wide range of hydraulic designs and geometric deviations are difficult by direct method. This paper presents a hybrid approach for fourier transformed operational excitation forces, which uses pseudo-inverse matrix of the transfer matrix for the system and the measured vibrational data with standard installed pump. The determination of the transfer function matrix is based on a linear rotor/stationary system and steady state harmonic response in finite element analysis. And, vibrational data is collected in both vertical and horizontal directions at inboard and outboard bearing housings. The results of the process may be enhanced by making acceleration measurements at many more locations than there are forces to be determined.

비등방성 복합적층판 및 쉘의 고차전단변형을 고려한 비감쇄 동적응답 (Undamped Dynamic Response of Anisotropic Laminated Composite Plates and Shell Structures using a Higher-order Shear Deformation Theory)

  • 윤석호;한성천;장석윤
    • 한국강구조학회 논문집
    • /
    • 제9권3호통권32호
    • /
    • pp.333-340
    • /
    • 1997
  • 본 연구에서는 복합재료로 구성된 복합적층판 및 쉘에 대하여 3차 전단 변형이론을 이용한 변위를 가정하여 단순지지 경계조건을 만족하는 변위형상함수를 퓨리예급수로 전개하고 동적 평형 방정식을 유도하여 뉴마크의 수치적분법을 사용하여 단면특성계수, 재료의 특성, 층의 배열에 따른 복합적층판 및 쉘의 비감쇄 동적응답특성을 연구하였다.

  • PDF

플렉서블 디스플레이 적용을 위한 저온 실리콘 질화막의 N2 플라즈마 처리 영향 (Influence of Nitrogen Plasma Treatment on Low Temperature Deposited Silicon Nitride Thin Film for Flexible Display)

  • 김성종;김문근;권광호;김종관
    • 한국전기전자재료학회논문지
    • /
    • 제27권1호
    • /
    • pp.39-44
    • /
    • 2014
  • Silicon nitride thin film deposited with Plasma Enhanced Chemical Vapor Deposition was treated by a nitrogen plasma generated by Inductively Coupled Plasma at room temperature. The treatment was investigated by Fourier Transform Infrared Spectroscopy and Atomic Force Microscopy on the surface at various RF source powers at two RF bias powers. The amount of hydrogen was reduced and the surface roughness of the films was decreased remarkably after the plasma treatment. In order to understand the causes, we analyzed the plasma diagnostics by Optical Emission Spectroscopy and Double Langmuir Probe. Based on these analysis results, we show that the nitrogen plasma treatment was effective in the improving of the properties silicon nitride thin film for flexible display.

EVALUATION OF WATER REPELLENCY FOR SILICON OXIDE FILMS PREPARED BY RF PLASMA-ENTRANCED CVD

  • Sekoguchi, Hiroki;Hozumi, Atsuhi;Kakionoki, Nobuyuki;Takai, Osamu
    • 한국표면공학회지
    • /
    • 제29권6호
    • /
    • pp.781-787
    • /
    • 1996
  • Silicom oxide films with good water repellency were prepared by rf plasma-enhanced CVD (rf-PECVD) using four kinds of organosilicon compound, which had different number of methyl ($CH_3$) groups, and oxygen as gas sources. The differences in the deposition rates, film composition and film properties were studied in detail. Water repellency depended on the number of $CH_3$ groups in the organosilicon compounds and the partial pressure of oxygen in the plasma. The highest contact angle for water drops, about 95 degrees, was obtained when trimethy lmethoxy silane (TMMOS) was used. The contact angle decreased with the amount of oxygen gas introduced into the plasma. The dissociation of $CH_3$ groups by adding oxygen was comfirmed by Fourier transform infrared spectroscopy(FTIR) and X-ray photoelectron spectroscopy (XPS). The optical properties were estimated by double-beam spectroscopy and ellipsometry. The transmittance of the glass plate coated by the film prepared with tetramethoxy silane (TMOS) was about 90% and the refractive index of film was 1.44. This value was smaller than the refractive index of a glass plate(soda lime glass, refractive index is 1.515) and this film played a role of anti-refractive coating.

  • PDF

Compositional Characterization of Petroleum Heavy Oils Generated from Vacuum Distillation and Catalytic Cracking by Positive-mode APPI FT-ICR Mass Spectrometry

  • Kim, Eun-Kyoung;No, Myoung-Han;Koh, Jae-Suk;Kim, Sung-Whan
    • Mass Spectrometry Letters
    • /
    • 제2권2호
    • /
    • pp.41-44
    • /
    • 2011
  • Molecular compositions of two types of heavy oil were studied using positive atmospheric pressure photoionization (APPI) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Vacuum gas oil (VGO) was generated from vacuum distillation of atmospheric residual oil (AR), and slurry oil (SLO) was generated from catalytic cracking of AR. These heavy oils have similar boiling point ranges in the range of 210-$650^{\circ}C$, but they showed different mass ranges and double-bond equivalent (DBE) distributions. Using DBE and carbon number distributions, aromatic ring distributions, and the extent of alkyl side chains were estimated. In addition to the main aromatic hydrocarbon compounds, those containing sulfur, nitrogen, and oxygen heteroatoms were identified using simple sample preparation and ultra-high mass resolution FT-ICR MS analysis. VGO is primarily composed of mono- and di-aromatic hydrocarbons as well as sulfur-containing hydrocarbons, whereas SLO contained mainly polyaromatic hydrocarbons and sulfur-containing hydrocarbons. Both heavy oils contain polyaromatic nitrogen components. SLO inludes shorter aromatic alkyl side chains than VGO. This study demonstrates that APPI FT-ICR MS is useful for molecular composition characterization of petroleum heavy oils obtained from different refining processes.

기하학적 초기결함을 갖는 원통형 쉘의 탄성 좌굴신뢰성 해석 (Elastic Buckling Reliability Analysis of Circular Cylindrical Shell with Random Geometric Initial Imperfection)

  • 양영순;김두기
    • 대한조선학회논문집
    • /
    • 제29권2호
    • /
    • pp.103-114
    • /
    • 1992
  • 본 논문에서는 기하학적 초기결함을 갖는 원통형 쉘이 축방향 압축하중을 받는 경우의 탄성좌굴 신뢰성 해석을 수행하였다. 이를 위하여 Donnell형의 비선형 편미분 방정식으로부터 Galerkin근사법을 사용하여 좌굴모드간의 연성효과를 고려한 불완전한 원통형 쉘의 좌굴하중을 구할 수 있는 다중모드 해석기법을 정식화하였다. 이때 기하학적 초기결함은 축대칭 및 비 축대칭 좌굴모드 형태의 이중급수로 가정하고, 각 급수의 계수는 결합정규분포특성을 갖는 확률변수로 취급하였다. 신뢰성 해석방법으로는 Monte Carlo기법을 사용하였고 초기결함의 통계적 특성의 변화에 따른 좌굴신뢰도의 변화 특성을 살펴보고 실제 경우에 적용하여 그 결과를 검토하였다.

  • PDF

Investigation of Performance Degradation of Shack Hartmann Wavefront Sensing Due to Pupil Irradiance Profile

  • Lee Jun-Ho;Lee Yaung-Cheol;Kang Eung-Cheol
    • Journal of the Optical Society of Korea
    • /
    • 제10권1호
    • /
    • pp.16-22
    • /
    • 2006
  • Wavefront sensing using a Shack-Hartmann sensor has been widely used for estimating wavefront errors or distortions. The sensor combines the local slopes, which are estimated from the centroids of each lenslet image, to give the overall wavefront reconstruction. It was previously shown that the pupil-plane irradiance profile effects the centroid estimation. Furthermore, a previous study reported that the reconstructed wavefront from a planar wavefront with a Gaussian pupil irradiance profile contains large focus and spherical aberration terms when there is a focus error. However, it has not been reported yet how seriously the pupil irradiance profiles, which can occur in practical applications, effect the sensing errors. This paper considered two cases when the irradiance profiles are not uniform: 1) when the light source is Gaussian and 2) when there is a partial interference due to a double reflection by a beam splitting element. The images formed by a Shack-Hartmann sensor were simulated through fast Fourier transform and were then supposed to be detected by a noiseless CCD camera. The simulations found that sensing errors, due to the Gaussian irradiance profile and the partial interference, were found to be smaller than RMS ${\lambda}/50$ when ${\lambda}$ is $0.6328\;{\mu}m$, which can be ignored in most practical cases where the reference and test beams have the same irradiance profiles.

DEGRADATION OF Zn$_3$$N_2$ FILMS PREPARED BY REACTIVE RF MAGNETRON SPUTTERING

  • Futsuhara, Masanobu;Yoshioka, Katsuaki;Takai, Osamu
    • 한국표면공학회지
    • /
    • 제29권5호
    • /
    • pp.563-569
    • /
    • 1996
  • Degradation of $Zn_3N_2$ films is studied by using several analytical techniques. Polycrystalline $Zn_3N_2$ films prepared by reactie rf magnetron sputtering are kept in the air. Electrical and optical properties are measured by using van der Pauw technique and double-beam spectrometry. Structure and chemical bonding states are studied by X-ray diffraction(XRD), Fourier transfer infrared ray spectroscopy(FT-IR) and X-ray photoelectron specroscopy (XPS). Significant differences are observed in optical properties between the degraded film and the ZnO film. XRD analysis reveals that the degraded film contains very small ZnO grains because very weak and broad ZnO peaks are observed. XPS and FT-IR measurements reveal the formation of $Zn(OH)_2$ in the degraded film. The existence of N-H bonds in degraded films is exhibited from the N 1s spectra. $Zn_3N_2$ change into the mixture of ZnO, $Zn(OH)_2$ and an ammonium salt.

  • PDF