Proficiency Test for the Dosimetry Audit Service Provider

  • Chul-Young Yi;In Jung Kim;Jong In Park;Yun Ho Kim;Young Min Seong
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.72-79
    • /
    • 2022
  • Purpose: The proficiency test was conducted to assess the performance of the dosimetry audit service provider in the readout practice of the dose delivered to patients in medical institutions. Methods: A certain amount of the absorbed dose to water for the high-energy X-ray from the medical linear accelerator (LINAC) installed in the Korea Research Institute of Standards and Science (KRISS) was delivered to the postal dose audit package given by the dosimetry audit service provider, in which the radio-photoluminescence (RPL) glass dosimeters were mounted. The dosimetry audit service provider read the RPL glass dosimeters and sent the readout dose value with its uncertainty to KRISS. The performance of the dosimetry audit service provider was evaluated based on the En number given in ISO/IEC 17043:2010. Results: The evaluated En number was -0.954. Based on the ISO/IEC 17043, the performance of the dosimetry service provider is "satisfactory." Conclusions: As part of the conformity assessment, the KRISS performed the proficiency test over the postal dose audit practice run by the dosimetry audit service provider. The proficiency test is in line with confirming the traceability of the medical institutions to the primary standard of absorbed dose to the water of the KRISS and ensuring the confidence of the dosimetry audit service provider.

A new research program that aims to establish an external audit system to radiotherapy QA in Japan

  • Shimbo, Munefumi;Tabushi, Katsuyoshi;Endo, Masahiro;Ikeda, Hiroshi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.17-18
    • /
    • 2002
  • Last year, a three-year research program was started in order to establish an external audit system to radiotherapy QA in Japan. It consists of questionnaire surveys, mailed (off-site) dosimetry and visited (on-site) dosimetry at radiotherapy facilities in Japan. The first questionnaire was sent to all Japanese radiotherapy facilities in October 2001, surveying basic QA procedures at each facility. 628 answers were returned with the return rate of 87%. In February 2002, the second questionnaire was sent. Off-site and on-site dosimetry have been tested in several facilities, and will be started soon. We anticipates that this program will gradually grow to a radiotherapy quality control center similar to Radiological Physics Center at MD Anderson Hospital.

  • PDF

Postal Dosimetry Audits for the Domestic Medical Linear Accelerator

  • Kim, Kum Bae;Choi, Sang Hyoun
    • 한국의학물리학회지:의학물리
    • /
    • 제31권2호
    • /
    • pp.20-28
    • /
    • 2020
  • Purpose: The objective of this study is to perform Postal dosimetry audits for medical linear accelerators in radiation therapy institutions using glass dosimeters and Gafchromic film reading systems and postal dosimetry audit procedures, and to evaluate radiation therapy doses and mechanical accuracy in medical institutions. Methods: Photon output measured and analyzed using a standard phantom for measuring photon output dose using a glass dosimeter for medical linear accelerators. Mechanical accuracy was measured and analyzed using software for film measurement. Results: Measurement and analysis of photon beam output dose using a standard phantom glass dosimeter for photon beam output dose measurement was completed. All tolerance doses were within 5%. Mechanical accuracy measurement and analysis using a standard phantom for verifying the mechanical accuracy of linear accelerator (LINAC) using a Gafchromic film were completed, and all results were shown within tolerances (2 mm or less). Conclusions: In this study, Postal dosimetry audits were performed on the output dose and mechanical accuracy of photon beams (207 beams) for 106 LINACs from 48 institutions. As a result of corrective action and re-execution, it was confirmed that all engines met the acceptable standard within 2 mm in the linear accelerator.

식품의약품안전청의 치료방사선 선량보증과 측정불확도 (KFDA TLD Dose Quality Audit and Measurement Uncertainty)

  • 정희교;이현구;김귀야;양현규;임천일
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.153-156
    • /
    • 2004
  • 식품의약품안전청은 1978년 12월 방사선 분야의 국가교정검사기관으로 지정되어 현재까지 Co-60선원을 이용 치료준위 방사선측정기에 대한 교정을 수행하고 있다. 식약청의 에어커마와 물 흡수선량 측정값은 국제도량형국(BIPM)과 측정소급성을 유지하고 있으며, 교정계수의 확장불확도는 0.9 %(k=2)이다. 식약청에서는 외부방사선에 대한 선량보증의 일환으로 1999년 전리함을 이용하여 방사선치료기관의 선량측정을 수행하였으며, 2002년부터 열형광선량계(TLD)를 이용한 선량측정체계를 확립 ${\cdot}$ 운영하고 있다. TLD 판독에 대한 측정불확도는 1.6 %(k=1)이며, 측정불확도를 감안하여 선량보증의 허용한계를 ${\pm}$ 5 %로 설정하였다. TLD 판독값을 선량으로 전환하는 과정에서 선질, 비선형성, 홀더사용 등의 영향을 보정하기 위한 보정정수를 사용하였다. 2003년도 치료방사선 선량보증사업에는 53개 기관(71개 선질)이 참여하였다. 선량보증 결과 71개 선질 중63개 선질(89 %)이 1차 측정에서 허용한계를 만족하였다. 허용한계 초과기관에 대해서는 재측정을 수행하였고, 그 결과 모두 허용한계 이내의 값을 나타냄을 확인하였다.

  • PDF

Design of Multipurpose Phantom for External Audit on Radiotherapy

  • Lim, Sangwook
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.122-129
    • /
    • 2021
  • Purpose: This study aimed to design a multipurpose dose verification phantom for external audits to secure safe and optimal radiation therapy. Methods: In this study, we used International Atomic Energy Agency (IAEA) LiF powder thermoluminescence dosimeter (TLD), which is generally used in the therapeutic radiation dose assurance project. The newly designed multipurpose phantom (MPP) consists of a container filled with water, a TLD holder, and two water-pressing covers. The size of the phantom was designed to be sufficient (30×30×30 cm3). The water container was filled with water and pressed with the cover for normal incidence to be fixed. The surface of the MPP was devised to maintain the same distance from the source at all times, even in the case of oblique incidence regardless of the water level. The MPP was irradiated with 6, 10, and 15 MV photon beams from Varian Linear Accelerator and measured by a 1.25 cm3 ionization chamber to get the correction factors. Monte Carlo (MC) simulation was also used to compare the measurements. Results: The result obtained by MC had a relatively high uncertainty of 1% at the dosimetry point, but it showed a correction factor value of 1.3% at the 5 cm point. The energy dependence was large at 6 MV and small at 15 MV. Various dosimetric parameters for external audits can be performed within an hour. Conclusions: The results allow an objective comparison of the quality assurance (QA) of individual hospitals. Therefore, this can be employed for external audits or QA systems in radiation therapy institutions.

흡수선량 측정 시 동종 원통형 이온함에서 이온함 간 변화 (Chamber-to-chamber Variations in the Same Type of a Cylindrical Chamber for the Measurements of Absorbed Doses)

  • 김성훈;허현도;최상현;김혁주;임천일;신동오;최진호
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.120-125
    • /
    • 2010
  • 물흡수선량에 기반한 표준 측정법을 사용하여 흡수선량을 측정 시에 여러 요인들이 크건, 작건, 미미하건 간에 선량 측정의 정확성에 영향을 미칠 수 있다. 이온함의 선질 보정 인자(the beam quality correction factor) ${\kappa}_{Q,Q_0}$ 값 또한 그 중 한 요인이 될 수 있다. 본 연구에서는 특정 이온함 유형(PTW30013, PTW, Germany)을 선정하여, 국내에서 사용하고 있는 기관들로부터 9개의 이온함을 수집하였다. 동일한 전위계와 전기선으로 9개 이온함을 국내 이차표준기관으로부터 교정을 받았다. 이렇게 교정받은 이온함들을 사용하여 Siemens ONCOR 장비의 광자 빔 6 MV와 10 MV 그리고 전자 빔 12 MeV에 대해 기준 조건하에서 흡수선량을 측정하였다. 이온함 간 선량 값의 최대 차이는 광자 빔 6 MV의 경우엔 2.4%, 10MV의 경우에 0.8%, 전자 빔 12 MeV의 경우엔 0.8%이었다. 6 MV에서의 큰 차이는 측정 과정에 문제가 없었다면, 동일한 ${\kappa}_{Q,Q_0}$ 값을 모든 이온함에 적용한 게 한 요인이 될 수 있다. 이는 또한 외부 독립검사가 왜 중요한지를 보여 주는 예라 하겠다.

열형광선량계를 이용한 전자선 품질보증 프로그램에 관한 연구 (Quality Assurance Program of Electron Beams Using Thermoluminescence Dosimetry)

  • 라정은;김귀야;정희교;신동오;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제16권2호
    • /
    • pp.62-69
    • /
    • 2005
  • 본 연구에서는 열형광선량계에 대한 전자선에너지 보정인수를 구하여 이온함을 이용한 물 흡수선량과 상호 비교 분석하여 열형광선량계를 이용한 전자선의 품질보증 프로그램을 개발하고자 한다. 열형광물질은 분말형태인 $^7LiF$을 사용하였고 판독기는 Fimel사의 PCL-3 모델을 사용하였으며 전자선 선량측정에 이용되는 홀더는 PMMA 재질로 제작하였다. 열형광선량계는 선형가속기(Varian CL 2100C)에서 방출되는 전자선 에너지 6, 9, 12, 16, 20 MeV를 이용하여 각 에너지에 해당하는 기준깊이 $Z_{ref}$에 위치시켰으며 물 흡수선량 2 Gy가 되도록 조사하였다 이때 기준선량은 IAEA TRS-398 프로토콜에서 권고하고 있는 절차에 따라 식품의약품안전청에서 교정 받은 Roos형 평행평판형이온함을 사용하여 결정하였다. 열형광선량계의 물 흡수선량을 결정하기 위해 열형광선량계의 교정계수 및 선량 반응도에 대한 보정인수, 퇴색보정인수, 에너지보정인수 등을 산출하였다. 또한 본 연구를 통해 결정된 교정계수 및 각각의 보정인수의 정확도를 검증하기 위해 백지정사(blind test)를 실시하였으며 그 결과, 에너지 9, 16, 20 MeV전자선에서 상대 표준편차가 각각 $2.98\%,\;3.39\%$ 그리고 $0.01\%$로 나타났다 이는 전자선의 허용수준인 $\pm5\%$이내 포함되는 결과로 향후 국내 의료기관에서 사용하고 있는 전자선의 출력 선량측정에 대한 주기적인 품질보증을 위해 열형광선량계가 적극 활용될 것으로 기대한다.

  • PDF

한국의학물리학회 선형가속기 외부 품질관리 실시 현황보고 (Report on the External Audits Conducted by Korean Society of Medical Physics)

  • 허현도;조광환;조삼주;최상현;김동욱;황의중;김기환;민철기;최태진;오영기;이승준;박달;박성광;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.315-322
    • /
    • 2013
  • 전문가 그룹의 외부검사를 통하여 의료기관 자체적으로 시행되고 있는 품질관리를 평가하고 구조적 문제점에 대한 상호보완을 하고자 하였다. 외부 검사의 정당성 확보를 위해 전국 80여 개의 의료기관 중 지역 분포를 고려하여 30여 개를 선정하였고, 최종 25개의 의료기관이 자발적 참여의사를 신청하였다. 참여의료기관은 비공개를 원칙으로 하였고, 사전에 상호 비교하여 검증된 측정 장비를 가지고 직접 방문하여 측정하는 것을 원칙으로 하였다. 두 개 이상의 광자선을 대상으로 출력선량을 측정하였고, 갠트리회전 정확도, 콜리메이터 회전 정확도, 다엽콜리메이터 이동 위치 정확도 등을 측정하였다. 출력선량 측정에서 6 MV의 경우 -0.8%~4.5%까지 절대오차를 보였고, 10 MV의 경우 -0.79%~3.01%이었고, 15 MV에서 -0.7%~0.07% 절대오차를 나타내었다. 25개 의료 기관을 대상으로 한 50개의 광자선 중에서 절대 흡수선량이 2% 이상 되는 에너지가 8개(16%)로 나타났다. 조사면과 갠트리, 콜리메이터 회전축 일치도는 2개 의료기관을 제외하고 모두 ${\pm}2$ mm 이내의 결과를 보였다. 다엽콜리메이터 이동 위치 정확도는 모두 ${\pm}1$ mm 이내의 정확도를 보였다. 에너지 선질 조사에서 광자선 6 MV의 경우 KQ 값의 최고값과 최저값의 차이는 0.4%로 나타났다. 물 흡수선량 기반 측정 기준서 사용기관은 21개(84%), 공기 흡수선량 기반 측정 기준서 사용기관은 4개(16%)로 조사되었고, SSD 측정법을 사용하는 기관은 22개, SAD 측정법을 사용하는 기관은 3개 기관으로 조사되었다. 외부검사는 자체적으로 시행되고 있는 품질관리의 구조적인 문제점을 찾아 상호 보완하는 것임으로 매우 중요하다. 따라서 전문가 그룹 및 국가가 함께 주기적이고, 지속적인 외부검사가 시행 될 수 있도록 국제 수준의 전문가의 양성 및 국가지원 제도가 필요하다고 사료된다.

고체팬텀을 이용한 국내 방사선 치료시설의 흡수선량에 대한 조사 (External Auditing on Absorbed Dose Using a Solid Water Phantom for Domestic Radiotherapy Facilities)

  • 최창헌;김정인;박종민;박양균;조건우;조운갑;임천일;예성준
    • Radiation Oncology Journal
    • /
    • 제28권1호
    • /
    • pp.50-56
    • /
    • 2010
  • 목 적: 제 3기관에 의해 독립적으로 수행된 방사선 치료 빔의 흡수 선량을 외부 감사의 결과로 보고 한다. 이를 위해 쉽고 편리하게 설치 가능 한 고체 팬텀을 이용하여 흡수 선량을 측정하는 방법을 개발했다. 대상 및 방법: 2008년 12개 방사선 치료 시설에서 외부 감사 프로그램에 참여하였고 47개의 광자선과 전자선의 제 3기관에 의해 American Association of Physicists in Medicine (AAPM) task group (TG)-51 프로토콜을 사용하여 독립적으로 교정되었다. AAPM TG-51 프로토콜은 물에서의 측정을 권고 하고 있지만 팬텀으로 물은 바쁜 병원 상황에선 몇 가지 단점이 있다. 설치와 수송이 편리하고 재현성이 있는 고체 팬텀을 사용하였다. 광자선과 전자선에 대한 물과 고체 팬텀 사이의 선량 보정인자는 스케일링 방법과 실험적 측정에 의해 결정되었다. 결 과: 대부분의 빔은(74%) 제3기관의 프로토콜로 측정한 결과 2%의 편차 이내였다. 그러나 20개 중 2개의 광자선과 27개 중 3개의 전자선은 허용범위(3%)를 초과 하였다. 특히 그중 2개의 빔은 10% 이상의 편차를 보여주고 있다. 6 MV 초과의 고에너지 광자선은 보정인자가 없었다. 6 MV 광자선의 경우 고체 팬텀에서의 흡수선량은 물에서의 흡수 선량보다 0.4% 작게 나타났다. 전자선에 대한 보정인자도 결정되었는데 전자선의 에너지가 증가함에 따라 보정인자는 작아지는 경향을 보여준다. 고체팬텀을 사용한 TG-51 프로토콜의 측정 오차는 ${\pm}1.22%$로 나타났다. 결 론: 개발된 방법은 다기관 임상 연구의 인증 프로그램에 참여할 수 있는 외부 감사 기관 프로그램에 성공적으로 적용되었다. 이 선량측정은 선량을 측정하기 위한 시간을 줄이고 물을 설치할 때의 생길 수 있는 측정오차를 감소시킨다.