• 제목/요약/키워드: Dose management

검색결과 869건 처리시간 0.03초

일반인들의 항공여객기 이용 시 우주방사선 피폭선량 비교 분석 (Analysis of Cosmic Radiation Dose of People by Abroad Travel)

  • 장동근;신상화
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권4호
    • /
    • pp.339-344
    • /
    • 2018
  • Humans received an exposure dose of 2.4 mSv of natural radiation per year, of which the contribution of spacecraft accounts for about 75%. The crew of the aircraft has increased radiation exposure doses based on cosmic radiation safety management regulations There is no reference to air passengers. Therefore, in this study, we measured the radiation exposure dose received in the sky at high altitude during flight, and tried to compare the radiation exposure dose received by ordinary people during flight. We selected 20 sample specimens, including major tourist spots and the capital by continent with direct flights from Incheon International Airport. Using the CARI-6/6M model and the NAIRAS model, which are cosmic radiation prediction models provided at the National Radio Research Institute, we measured the cosmic radiation exposure dose by the selected flight and departure/arrival place. In the case of exposure dose, Beijing was the lowest at $2.87{\mu}Sv$ (NAIRAS) and $2.05{\mu}Sv$ (CARI - 6/6M), New York had the highest at $146.45{\mu}Sv$ (NAIRAS) and $79.42{\mu}Sv$ (CARI - 6/6M). We found that the route using Arctic routes at the same time and distance will receive more exposure dose than other paths. While the dose of cosmic radiation to be received during flight does not have a decisive influence on the human body, because of the greater risk of stochastic effects in the case of frequent flights and in children with high radiation sensitivity Institutional regulation should be prepared for this.

자체제작 Pb 밴딩을 이용한 피폭선량 감소 (Exposure dose Reduction using Pb Banding of own manufacturing)

  • 김창규
    • 디지털융복합연구
    • /
    • 제11권6호
    • /
    • pp.269-273
    • /
    • 2013
  • 치과 진료시 파노라마 장치를 이용한 검사에서 유리선량계를 사용하여 피검자의 피폭선량을 측정하였다. 특히 방사선에 민감한 수정체의 피폭선량을 줄이기 위하여 자체 제작한 Pb밴딩의 크기에 따라 수정체 피폭선량을 측정한 결과 Pb밴딩의 크기에 따라서 수정체의 피폭선량이 다르다는 것을 확인할 수 있었다. Pb밴딩의 크기가 $3{\times}20{\times}0.2cm$에서는 정상치보다 피폭선량이 증가하는 경향을 보였으며 $5{\times}20{\times}0.2cm$ 이상의 크기에서는 피폭선량이 감소하는 결과를 보였다. 또한 획득되어진 영상 $7{\times}20{\times}0.2cm$ 크기에서 진단에 부적합한 영상으로 판정되었다. 그러므로 피폭선량을 최소화하고 효과적인 파노라마 검사를 수행하기 위해서는 Pb밴딩 $5{\times}20{\times}0.2cm$이상 $6{\times}20{\times}0.2cm$이하 크기를 사용하여 검사에 활용하면 피폭선량이 감소될 것으로 기대한다.

고용량 방사성옥소 치료 병실의 최대치 산출 (Maximum Value Calculation of High Dose Radioiodine Therapy Room)

  • 이경재;조현덕;고길만;박영재;이인원
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.28-34
    • /
    • 2010
  • 갑상선암 환자가 증가함에 따라 고용량 방사성옥소 치료환자 또한 적체되고 있는 추세이다. 따라서 현재 시설의 수용 능력을 고려하여 치료할 수 있는 병실의 최대치를 산출해 보고자 한다. 본원에 입원하는 고용량 방사성옥소 치료 환자의 방출 오 폐수량과 오 폐수의 방사능을 측정하고 고용량 방사성옥소 치료 병실에서 대기 중으로 방출하는 공기 중의 방사능 농도를 측정한다. 측정된 오 폐수의 방사능과 방출하는 공기 중의 농도가 교육과학기술부에서 고시하는 기준인 배수 중의 배출 관리 기준 30 Bq/L 및 배기 중의 배출관리기준 3 $Bq/m^3$을 만족할 때 치료 가능한 병실의 최대치를 계산한다. 가장 보수적인 수치로 계산하여 환자 1명을 치료할 경우 배출되는 오 폐수의 평균 방사능의 농도는 8 MBq/L였으며, 정화조에서 117일의 감쇠 시간을 거친 후의 평균 방사능의 농도는 29.5 Bq/L였다. 환자 2명을 치료할 경우 배출되는 오 폐수의 평균 방사능의 농도는 16 MBq/L였으며, 정화조에서 70일의 감쇠 시간을 거친 후의 평균 방사능의 농도는 29.7 Bq/L였다. 또한 같은 조건일 경우 치료 병실에서 RI 배기 filter를 통과하여 방출된 공기 중의 방사능 농도는 0.38 $Bq/m^3$였다. 수용 능력을 고려하여 치료할 수 있는 고용량 방사성옥소 치료 병실의 최대치를 산출하여 현재의 시설에 적용하고 병실 내 구조개선 등으로 2인실로 운영한다면 적체되어 있는 환자의 치료 대기 기간을 단축할 수 있으리라 사료된다.

  • PDF

연소도이득효과를 적용한 사용후핵연료 수송용기의 방사선원별 차폐영향 분석 (A Study on the Radiation Source Effect to the Radiation Shielding Analysis for a Spent-Fuel Cask Design with Burnup-Credit)

  • 김경오;김순영;고재훈;이강욱;김태만;윤정현
    • 방사성폐기물학회지
    • /
    • 제9권2호
    • /
    • pp.73-80
    • /
    • 2011
  • 한국방사성폐기물관리공단 주관 하에 개념 설계된, 연소도이득효과 적용 대용량 수송용기에 대해 방사선 차폐 안전성을 평가하였으며 여러 방사선원들이 수송용기 주변 선량률 분포에 미치는 영향을 분석하였다. 가능한 모든 방사선원(중성자선원, 감마선원, 방사화선원)들을 고려하였으며 보수적인 가상의 핵연료(너비: WH 17 RFA, 축방향: CE Type)를 선정, 실제 상황과 동일한 조건이 되도록 계산모델을 구축하였다. 모든 조건(정상 및 가상사고 조건)에서 표면선량률과 외부선량률이 법적기준치를 만족하고 있었으며 축방향 높이에 따라 각 선원들의 기여도가 변하고 있었지만 정상조건에서의 최대 표면선량률과 외부선량률은 방사화선원에 의한 영향이 가장 높은 것으로 확인되었다. 가상사고 조건에서는, 중성자선원의 선량률 기여도가 대략 90%에 달하고 있었으나 수송용기 끝단에서는 방사화선원에 의한 선량률이 급격하게 상승함에 따라 BUC 적용 수송용기의 방사선 차폐해석시 충분히 보수적으로 해석되도록 방사화선원을 정밀하게 분석하여 설정하여야 할 것으로 판단되었다.

SHIELDING ANALYSIS OF DUAL PURPOSE CASKS FOR SPENT NUCLEAR FUEL UNDER NORMAL STORAGE CONDITIONS

  • Ko, Jae-Hun;Park, Jea-Ho;Jung, In-Soo;Lee, Gang-Uk;Baeg, Chang-Yeal;Kim, Tae-Man
    • Nuclear Engineering and Technology
    • /
    • 제46권4호
    • /
    • pp.547-556
    • /
    • 2014
  • Korea expects a shortage in storage capacity for spent fuels at reactor sites. Therefore, a need for more metal and/or concrete casks for storage systems is anticipated for either the reactor site or away from the reactor for interim storage. For the purpose of interim storage and transportation, a dual purpose metal cask that can load 21 spent fuel assemblies is being developed by Korea Radioactive Waste Management Corporation (KRMC) in Korea. At first the gamma and neutron flux for the design basis fuel were determined assuming in-core environment (the temperature, pressure, etc. of the moderator, boron, cladding, $UO_2$ pellets) in which the design basis fuel is loaded, as input data. The evaluation simulated burnup up to 45,000 MWD/MTU and decay during ten years of cooling using the SAS2H/OGIGEN-S module of the SCALE5.1 system. The results from the source term evaluation were used as input data for the final shielding evaluation utilizing the MCNP Code, which yielded the effective dose rate. The design of the cask is based on the safety requirements for normal storage conditions under 10 CFR Part 72. A radiation shielding analysis of the metal storage cask optimized for loading 21 design basis fuels was performed for two cases; one for a single cask and the other for a $2{\times}10$ cask array. For the single cask, dose rates at the external surface of the metal cask, 1m and 2m away from the cask surface, were evaluated. For the $2{\times}10$ cask array, dose rates at the center point of the array and at the center of the casks' height were evaluated. The results of the shielding analysis for the single cask show that dose rates were considerably higher at the lower side (from the bottom of the cask to the bottom of the neutron shielding) of the cask, at over 2mSv/hr at the external surface of the cask. However, this is not considered to be a significant issue since additional shielding will be installed at the storage facility. The shielding analysis results for the $2{\times}10$ cask array showed exponential decrease with distance off the sources. The controlled area boundary was calculated to be approximately 280m from the array, with a dose rate of 25mrem/yr. Actual dose rates within the controlled area boundary will be lower than 25mrem/yr, due to the decay of radioactivity of spent fuel in storage.

Web-based Personal Dose Management System for Data Recording on Dosimeter Usage: A Case of Tanzania Atomic Energy Commission

  • Mseke, Angela;Ngatunga, John Ben;Sam, Anael;Nyambo, Devotha G.
    • International Journal of Computer Science & Network Security
    • /
    • 제22권2호
    • /
    • pp.15-22
    • /
    • 2022
  • Modern technology drives the world, increasing performance while reducing labor and time expenses. Tanzania Atomic Energy Commission (TAEC) tracks employee's levels of exposure to radiation sources using dosimeters. According to legal compliance, workers wear dosimeters for three months and one month at the workplace. However, TAEC has problems in tracking, issuing and returning dosimeters because the existing tracking is done manually. The study intended to develop a Personal Dose Management System (PDMS) that processes and manages the data collected by dosimeters for easy and accurate records. During the requirements elicitation process, the study looked at the existing system. PDMS' requirement gathering included document reviews, user interviews, and focused group discussions. Development and testing of the system were implemented by applying the evolutionary prototyping technique. The system provides a login interface for system administrators, radiation officers, and Occupational Exposed Workers. The PDMS grants TAEC Staff access to monitor individual exposed workers, prints individual and institutional reports and manages workers' information. The system reminds the users when to return dosimeters to TAEC, generate reports, and facilitates dispatching and receiving dosimeters effectively. PDMS increases efficiency and effectiveness while minimizing workload, paperwork, and inaccurate records. Therefore, based on the results obtained from the system, it is recommended to use the system to improve dosimeter data management at the institution.

두개부 혈관조영실에서 공간산란선량의 분포와 관리 (Distribution and Management of Spatial Dose Rate in Neuro Angio Room)

  • 이미화;정홍량;임청환;홍동희;김기정;김상현
    • 디지털융복합연구
    • /
    • 제12권4호
    • /
    • pp.427-435
    • /
    • 2014
  • 본 연구는 두개부 혈관조영실에서 시행되는 중재적시술 시 거리 및 방향 별로 공간산란선량의 분포를 측정함으로써 산란선 노출범위를 알고, 방사선관계종사자에게 적절한 작업위치와 거리 등을 인지하여 스스로 산란선으로 부터 최소의 피폭을 받을 수 있도록 하는데 목적이 있다. 팬텀에서 반시계 방향으로 $45^{\circ}$ 각도로 분류하여 7방향의 구획 방향(A, B, C, D, E, F, G)을 설정하고, 팬텀의 중심에서부터 길이를 측정하여 각 방향마다 50cm, 100cm, 150cm, 200cm로 분류하였다. 총 28곳에서 투시의 정면, 측면, 양방향의 공간선량을 측정하여 분석하였다. 측정된 선량은 거리 별로는 50cm에서 가장 높게 측정되었으며, 200cm로 거리가 증가할수록 선량이 급격히 감소하였다. 동일한 구역에서라면 저격촬영의 공간선량이 거리와 방향에 따라 크게는 9배 이상 차이가 나타났다. 방호용 칸막이 설치만으로 약 84.52%~93.54% 이상의 피폭선량이 감쇄되었다.

방사선관리구역내의 종사자 및 임상실습 학생의 개인피폭선량 비교 분석 (Analysis of Individual Exposure Dose of Workers and Clinical Practice Students in Radiation Management Area)

  • 이주아
    • 한국콘텐츠학회논문지
    • /
    • 제17권11호
    • /
    • pp.383-388
    • /
    • 2017
  • 방사선구역내의 종사자 간 선량 비교 및 동일한 구역 내에서 임상실습에 임하는 학생들의 선량을 추가하여 비교함으로써 방사선방어의 최적화 구현에 대한 기초자료를 제공하고자 하였다. 연구 대상은 2016년 1월부터 동년 12월까지 C대학병원 방사선 관리구역에 재직 중인 방사선관계종사자 121명과 방사선작업종사자 36명, 그리고 8주간의 임상실습을 이수한 121명의 학생을 비교 대상으로 하였다. 방사선관계종사자와 작업종사자 간의 심부 및 표층 선량은 관계종사자가 각각 $.7440{\pm}1.676mSv$$.7753{\pm}1.730mSv$로 가장 높게 나타났으며, 통계적으로 매우 유의하였다(p<.01). 세 그룹 간에는 심부 선량의 경우 임상실습학생이 $.143{\pm}.136mSv$로 가장 높게 나타났고, 표층 선량에서도 $.1513{\pm}.139mSv$로 가장 높게 나타났으며, 작업종사자가 두 경우 모두 가장 낮았다. 그룹 간의 평균의 차이는 통계적으로 매우 유의하였다(p<.01). 결론적으로 ALARA(As Low As Reasonably Achievable)원칙에 의거 철저한 관리가 필요하며, 특히 방사선안전관리의 사각지대에 놓여 있는 임상실습 학생에 대한 체계적인 피폭선량 관리가 필요할 것으로 사료된다.

C 대학병원의 개인선량계 판독과 영향 (Reading and Influence of Personal Dose Meter in University Hospital C)

  • 이주아
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.357-363
    • /
    • 2022
  • 본 연구 목적은 방사선관계종사자와 방사선작업종사자들의 직종별 방사선 피폭선량을 분석하여 폐 부작용 유발확률을 연구하는 데에 있다. 즉, 피폭관리 실태를 점검함으로써 방사선종사자들의 직업상 피폭에 대한 안전 점검 의식을 향상시키고 방사선안전관리에 도움을 주고자 한다. 방사선관계종사자와 방사선작업종사자 각각 3개의 직종별 (방사선사, 의사, 간호사)로 분류하였다. 피폭선량으로 인한 폐의 부작용 유발확률을 산출하기 위하여 ICRP103에 근거한 명목위험계수(Nominal risk factor)를 활용하였다. 방사선관계종사자의 1년간 심부선량은 방사선사 1.63 ± 2.84 mSv, 의사는 0.12 ± 0.22 mSv, 간호사는 0.59 ± 1.08 mSv로 나타났다. 이로 인하여, 폐의 부작용 유발 확률은 방사선사는 100,000당 1.1명, 의사는 10.082명, 간호사는 0.4명으로 나타났다. 방사선작업종사자의 1년간 심부선량은 방사선사 2.44 ± 3.30 mSv, 의사의 경우 0.19 ± 0.26 mSv, 간호사의 경우 0.12 ± 0.00 mSv이었다. 이 선량으로 인하여, 폐의 부작용 유발 확률은 방사선사는 100,000당 1.2명, 의사는 0.096명, 간호사는 0.06명으로 나타났다. 본 연구에서는 방사선 피폭선량의 직종별 폐에 부작용이 발생할 확률을 연구하여 향후 확률적 영향과 관련하여 방사선 안전관리를 위하여 유용한 자료로 활용될 것으로 사료된다.

A Case of Successful Management of Lung Cancer Pain Using Ultrahigh-dose Fentanyl Patch

  • Kim, Soo-Ok;Kim, Min-Jee;Kwon, Yong-Soo;Lim, Sung-Chul;Ban, Hee-Jung;Oh, In-Jae;Kim, Kyu-Sik;Kim, Young-Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • 제68권5호
    • /
    • pp.286-289
    • /
    • 2010
  • A 55-year old woman with advanced stage non-small cell lung cancer was admitted to hospital for the management of severe chest pain, which measured 7 out of 10 on a numerical rating scale (NRS). Despite palliative radiation and the application of multiple epidural blocks, she continued to experience severe cancer pain. We gradually increased the dose of transdermal fentanyl patches from $500{\mu}g/hr$ to $3,650{\mu}g/hr$, for 3 months without any significant side effects. Concomitantly, adjuvant therapy with antidepressants and anticonvulsants were added, decreasing the patient's pain to NRS 3~4 down from 7. After being transferred to a hospice clinic, her chest pain was well-controlled below NRS 4 by means of strong opioid medications, including the highest dose of transdermal fentanyl $4,050{\mu}g/hr$ for more than 16 months.