SHIELDING ANALYSIS OF DUAL PURPOSE CASKS FOR SPENT NUCLEAR FUEL UNDER NORMAL STORAGE CONDITIONS

  • Received : 2013.05.16
  • Accepted : 2014.02.19
  • Published : 2014.08.25

Abstract

Korea expects a shortage in storage capacity for spent fuels at reactor sites. Therefore, a need for more metal and/or concrete casks for storage systems is anticipated for either the reactor site or away from the reactor for interim storage. For the purpose of interim storage and transportation, a dual purpose metal cask that can load 21 spent fuel assemblies is being developed by Korea Radioactive Waste Management Corporation (KRMC) in Korea. At first the gamma and neutron flux for the design basis fuel were determined assuming in-core environment (the temperature, pressure, etc. of the moderator, boron, cladding, $UO_2$ pellets) in which the design basis fuel is loaded, as input data. The evaluation simulated burnup up to 45,000 MWD/MTU and decay during ten years of cooling using the SAS2H/OGIGEN-S module of the SCALE5.1 system. The results from the source term evaluation were used as input data for the final shielding evaluation utilizing the MCNP Code, which yielded the effective dose rate. The design of the cask is based on the safety requirements for normal storage conditions under 10 CFR Part 72. A radiation shielding analysis of the metal storage cask optimized for loading 21 design basis fuels was performed for two cases; one for a single cask and the other for a $2{\times}10$ cask array. For the single cask, dose rates at the external surface of the metal cask, 1m and 2m away from the cask surface, were evaluated. For the $2{\times}10$ cask array, dose rates at the center point of the array and at the center of the casks' height were evaluated. The results of the shielding analysis for the single cask show that dose rates were considerably higher at the lower side (from the bottom of the cask to the bottom of the neutron shielding) of the cask, at over 2mSv/hr at the external surface of the cask. However, this is not considered to be a significant issue since additional shielding will be installed at the storage facility. The shielding analysis results for the $2{\times}10$ cask array showed exponential decrease with distance off the sources. The controlled area boundary was calculated to be approximately 280m from the array, with a dose rate of 25mrem/yr. Actual dose rates within the controlled area boundary will be lower than 25mrem/yr, due to the decay of radioactivity of spent fuel in storage.

Keywords

References

  1. NUREG-1536, Standard Review Plan for Spent Fuel Dry Storage Systems at a General License Facility, US NRC, July 2010.
  2. NRC Docket No. 72.1008, "Final Safety Analysis Report for the HI-STAR 100 Cask System. Rev.0"
  3. NRC Docket No. 72.1014, "Final Safety Analysis Report for the HI-STORM 100 Cask System. Rev.4", June, 2006.
  4. ORNL/TM-2005-39, SCALE A Modular Code for performing Standardized computer Analyses for Licensing Evaluation, Sect. 32 S2 "SAS2:A Coupled 1-D Depletion and Shielding Analysis Module." Ver. 5.1
  5. A. G. Croff, M. A. Bjerke, G. W. Morrison, and L. M. Petrie, "Revised U-Pu Cycle PWR and BWR Models for the ORIGEN Computer Code", Oak Ridge National Laboratory Report ORNL-6051, 1978.
  6. NUREG/CR-6802, Recommendations for Shielding Evaluations for Transport and Storage Packages, Oak Ridge National Laboratory, US NRC, May 2010.
  7. LA-UR-03-1987, MCNP - A General Monte Carlo N Particle Transport Code, Version 5, Release 1.40, 2005
  8. YAEC-1937, Axial Burnup Profile Database Pressurized Water Reactors, Yankee Atomic Electric Company, Bolton, Massachusetts, May 1997.
  9. Conversion Coefficients for Use in Radiological Protection against External Radiation, Annals of the ICRP Publication 74, 1996.
  10. 10 CFR Part 72, Licensing requirements for the independent storage of spent nuclear fuel and high-level radioactive waste
  11. NUREG-1567, Standard Review Plan for Spent Fuel Dry Storage Facility, US NRC, 2000.