The Head Scatter Factor For Quasi - small Field Sizes (준소조사면에서의 산란인자)

  • 이상공;김진기;김정홍;김부길;권형철;김정수
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.13-19
    • /
    • 1995
  • The behavior of the correction factor associated with the collimator opening(head-scatter factor) were investigated for the 6MV x-ray beams of medical linear accelerator. The primary photon fluence was measured in air quasi-small fied size. Consideration in this study was given to the effect of head scatter factor with quasi-small fied size, the upper and lower collimator jaw scatter collection factors of quasi-small field (4-10cm) were measured with ion chamber. In general, the wedge factors which are used clinical practics are ignored of dependency on field sizes and depth. In wedge factors for each wedge filter were measured at various depth by using 6MV X-ray. In this present we inverstigated systematically the depth and field sizes dependency to determine the absorbed dose more accurately. Head scatter(upper-lower collimator jaw)appears to be (1) a small effect, less than 5% over the range of clinical field sizes (2) generated primarily at the flattening filter and therefored influenced most by the upper collimator setting.

  • PDF

Optimum Design and Tolerance Analysis of Multilayer Mirror for Obtaining Characteristic X-ray of 17.5 keV (몰리브덴(Mo) 특성방사선 획득을 위한 다층박막 거울의 최적 설계 및 공차 분석)

  • Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.23-28
    • /
    • 2009
  • Monochromatic X-ray can make a medical image of high contrast under a low radiation dose and can be easily generated by combining an X-ray tube and a multilayer mirror. A W/C multilayer mirror was optimally designed for a characteristic X-ray generated from a X-ray tube with Mo target. The d-spacing and the thickness ratio in design parameters were determined under the maximum-reflectivity condition. Tolerances for deposition and alignment of the W/C multilayer mirror were calculated. Within a deposition tolerance of 0.2nm and a alignment tolerance of ${\pm}0.01^{\circ}$, 85% of the theoretical peak reflectivity could be achieved. A multilayer mirror can be widely used for making medical images because of generating high fluence monochromatic X-ray.

  • PDF

Neutron Dosimetry with Solid State Track Detector (고체비적검출기(固體飛跡檢出器)를 이용(利用)한 중성자선량(中性子線量) 측정(測定))

  • Yook, Chong-Chul;Ro, Seung-Gy
    • Journal of Radiation Protection and Research
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 1977
  • A base of photographic posi-film which is commecially available has been found to be a possible alpha-particle track detector. Its neutron dosimetric characteristics, i. e., alpha-particle track registrating efficiency and optimum condition of track formation by chemical etching, have been determined experimentally. The range of neutron fluence and dose capable of being measured by a neutron dosimeter consisting of alpha-particle radiator foils $(^{10}B\;and\;^{27}Al)$ and posi-flim solid state track detector, has been estimated on the basis of experimental results and theoryetical background. This detector seems to be useful for neutron dosimetry because of many favorable properties, i. e., simplicity, cheapness and a wide range of sensitivitiy.

  • PDF

Research of Antioxidant Activity from Plant Resources using Proton Beam(I) (양성자 빔을 이용한 식물자원의 항산화 활성에 관한 연구(I))

  • Moon, Byung-Sik;Son, Gui-Youp;Choi, Jin-Kuk;Seo, Dong-Won;Lee, Kap-Duk
    • Journal of Life Science
    • /
    • v.17 no.8 s.88
    • /
    • pp.1100-1103
    • /
    • 2007
  • In proton therapy, the Bragg peak is spread out by modulating or degrading the energy of the particles to cover a well-defined target volume at a given depth. Proton transfer plays a key role in a variety of biological, the origin of the elements, tests of the standard model along with applications in medicine, industry and chemical phenomena such as water autoionization, fast proton diffusion, acid-base neutralization. We have studied the radiolysis of various natural resources and have evaluated the antioxidant activity of radiolysis products by proton beam. The most of antioxidant activities of natural resources were decreased with increasing proton fluence. Proton beam induced antioxidant activities both in 1,1-diphenyl-2-picrylhydrazyl radical (DPPH) assay and 2,2'-azinobis(3-ethylbenzot hialozinesulfonic acid) cation radical $(ABTS^{.+})$ assay by a dose dependent fashion.

Hydrophilic property by contact angle change of ion implanted polycarbonate (이온주입 Polycarbonate의 접촉각 변화에 의한 친수특성)

  • Lee, Chan-Young;Lee, Jae-Hyung;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.533-538
    • /
    • 2003
  • It has been shown that ion implantation produces remarkable improvements in surface-sensitive physical and chemical properties as well as other mechanical properties, in polymers. In this study, ion implantation was performed onto polymer, PC(polycarbonate), in order to investigate surface hydrophilic property through contact angle measurement using distilled water. PC was irradiated with N, Ar, Xe ions at the irradiation energy of $20\;{\sim}\;50keV$ and the dose range of $5{\times}10^{15},\;1{\times}10^{16},\;7{\times}10^{16}\;ions/cm^2$. The contact angle of water has been reduced with increasing fluence and ion mass but increased with increasing implanted energy. The changes of chemical and structural property are discussed in view of infrared spectroscopy and FT-IR, XPS, which shows increasing C-O bonding and C-C bonding. The root mean square of surface roughness examined by means of AFM changed smoothly from 0.387nm to 0.207nm and the change of wettability was discussed with respect to elastic and inelastic collisions obtained as results of TRIM simulation. It was found that wettability of the modified PC surface was affected on change of functional group and nuclear stopping or linear energy transfer(LET, energy deposited per unit track length per ion) that causes chain scission by displacing atom from polymer chains, but was not greatly dependant on surface morphology.

  • PDF

Dosimetric Characterization of an Ion Chamber Matrix for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석)

  • Lee, Jeong-Woo;Hong, Se-Mie;Kim, Yon-Lae;Choi, Kyoung-Sik;Jung, Jin-Beom;Lee, Doo-Hyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.131-135
    • /
    • 2006
  • A commercial ion chamber matrix was examined the characteristics and its performance for radiotherapy qualify assurance. The device was the I'mRT 2D-MatriXX (Scanditronix-Wellhofer, Schwarzenbruck, Germany). The 2D-MatriXX device consists of a 1020 vented ion chamber array, arranged in $24{\times}24cm^2$ matrix. Each ion chamber has a volume of $0.08cm^3$, spacing of 0.762 cm and minimum sampling time of 20 ms. For the investigation of the characteristics, dose linearity, output factor, short-term reproducibility and dose rate dependency were tested. In the testing of dose linearity. It has shown a good signal linearity within 1% in the range of $1{\sim}800$cGy. Dose rate dependency was found to be lower than 0.4% (Range: 100-600 Mu/min) relative to a dose rate of 300 Mu/min as a reference. Output factors matched very well within 0.5% compared with commissioned beam data using a ionization chamber (CC01, Scanditronix-Wellhofer, Schwarzenbruck, Germany) in the range of field sizes $3{\times}3{\sim}24{\times}24cm^2$. Short-term reproducibility (6 times with a interval of 15 minute) was also shown a good agreement within 0.5%, when the temperature and the pressure were corrected by each time of measurement. in addition, we compared enhanced dynamic wedge (EDW, Varian, Palo Alto, USA) profiles from calculated values in the radiation planning system with those from measurements of the MatriXX. Furthermore, anon-uniform IMRT dose fluence was tested. All the comparison studies have shown good agreements. In this study, the MatriXX was evaluated as a reliable dosimeter, and it could be used as a simplistic and convenient tool for radiotherapy qualify assurance.

  • PDF

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

The Output Factor of Small Field in Multileaf Collimator of 6 MV Photon Beams (다엽제한기 소조사면의 6 MV 광자선 출력선량계수)

  • Lee, Ho Joon;Choi, Tae-Jin;Oh, Young Kee;Jeun, Kyung Soo;Lee, Yong Hee;Kim, Jin Hee;Kim, Ok Bae;Oh, Se An;Kim, Sung Kyu;Ye, Ji Woon
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • The IMRT is proper implement to get high dose deliver to tumor as its shape and selective approach in radiation therapy. Since the IMRT is performed as modulated the radiation fluence by the MLC created the open shapes and its irradiation time, the dose of segment of radiation field effects on the cumulated portal dose. The accurate output factor of small and step shape of segment is important to improve the determination of deliver tumor dose as it is directly proportional to dose. This experiment performed with the 6 MV photon beam of Clinac Ex(Varian) from $3{\times}3cm^2$ to $0.5{\times}0.5cm^2$ small field size for collimator jaw in MLC free and/or for MLC open field in fixed collimator jaw $10{\times}10cm^2$ using the CC01 ion chamber, SFD diode, diamond detector and X-Omat film dosimetry. As results of normalized to the reference field of $10{\times}10cm^2$ of MLC, the output factor of $3{\times}3cm^2$ showed $0.899{\pm}0.0106$, $0.855{\pm}0.0106$ for $2{\times}2cm^2$, $0.764{\pm}0.0082$ for $1{\times}1cm^2$ and $0.602{\pm}0.0399$ for $0.5{\times}0.5cm^2$. The output factor of MLC open field has shown a maximum 3.8% higher than that of the collimator jaw open field.

Fast Neutron Dosimetry in Nuclear Criticality Accidents (핵임계사고시(核臨界事故時)에 있어서 속중성자선량(速中性子線量) 측정(測定))

  • Yook, Chong-Chul;Ro, Seung-Gy
    • Journal of Radiation Protection and Research
    • /
    • v.2 no.1
    • /
    • pp.17-23
    • /
    • 1977
  • The neutron dosimetrical parameters, i. e., the fission neutron spectrum-averaged cross-sections and the fluence-to-dose conversion factors have been calculated for some threshold detectors with the aid of a computer. The threshold detectors under investigation were the $^{115}In(n,\;n')^{115m}In,\;^{32}S(n,\;p)^{32}P$ and $^{27}Al(n,\;{\alpha})^{24}Na$ reactions. It is revealed that the average cross-sections($\bar{\sigma}$) for the $^{32}S(n,\;p)^{32}P$ reaction are independent of the spectral functions, namely, the Watt-Cranberg and Maxwellian forms. In the case of the $^{27}Al(n,\;{\alpha})^{24}Na$ reaction a variation of the $\bar{\sigma}$ values appears to be highly dependent on the fissioning types. It seems that both the average cross-section for the $^{115}In(n,\;n')^{11m}In$ reaction and the conversion factor are insensitive to the spectral deformation of fission neutrons. These phenomena make it applicable to use indium as a possible integral fast neutron dosimeter in nuclear criticality accidents provided that the virgin fission neutrons are completely free from the scattered neutrons.

  • PDF