• Title/Summary/Keyword: Distribution of body heat

Search Result 100, Processing Time 0.024 seconds

A study on the methods of regional body temperature palpation in Hwangdineijing (『황제내경』의 체열 분포 진단 방법 연구)

  • Kim, Kiwang
    • Journal of Korean Medical classics
    • /
    • v.30 no.1
    • /
    • pp.51-55
    • /
    • 2017
  • Objectives : Though regional body temperature palpation is one of well stylized diagnosis methods in Huangdineijing, it has not been thoroughly reconstructed. So I tried to find and reconstruct the methods in Huangdineijing to diagnose regional body temperature as a objective sign. Material and Methods : Huangdineijing(in Zhonghuayidian) was used for text search. "Heat(熱)", "Cold and Heat(寒熱)", "Cold and Warmth(寒溫)", "Root and Terminal(本末)" was used as searching keywords. By classifying and analysing searched sentences I reconstructed the original palpation methods. Results : Two types of regional temperature palpation method was found in Huangdineijing. One is the method palpating the Root(origin) points and Terminal points of the meridians, while the other method is that palpating the skin in anterior side of forearm. It was proved that they had been collaboratively used to diagnose the diseases related to meridians and it's collaterals. Conclusions :In the era of Huangdineijing, there was at least two types of regional temperature palpation method and their clinical usage was in complementary relations.

Using DITI to examine the pattern of subcutaneous heat of the climacteric patients (DITI를 이용한 갱년기 환자의 체열분포 양상)

  • Kim, Ro-Sa;Choi, Jung-Eun;Kim, Young-Suk;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.1 no.1
    • /
    • pp.38-46
    • /
    • 2002
  • 1. Objectives Among many symptoms that the climacteric patients complain of, the major subjective symptom is both heat in the upper part and cold in the lower part of the body(e.g foot, knee, and leg). We use DITI as a method to prove the symptoms of climacteric patients such as both heat in the upper part and cold in the lower part of the body, diagnose these symptoms, and follow up the progress of the clinical treatments. 2. Subjects and Methods We compare the subcutaneous heat of the climacteric patients with the symptom of heat in the upper part and cold in the lower part of the body with young women without any specific disease. The age distribution of the experimental group is 28 patients in 40's, and 22 in 50's. The mean age of the experimental group is $48.5{\pm}4.25$. The age distribution of the control group is 17 patients in teen, 26 in 20's, 7 in 30's. The mean age of the control group is $23.31{\pm}6.45$. We measure the subcutaneous heat on the cheeks, upper arms, palms, thighs, knees, dorsum pedis, lower back, hip, upper abdomen, lower abdomen of both groups and analyse the results. 3. Statistical methods All the results are statiscally analysed using student T-test of Microsoft Exel program. Statistically significant value by the analysis of variance procedure is P<0.05. 4. Results 1. The subcutaneous heat of the whole body of the experimental group shows hypothermia compared with control group, and the hypothermic pattern gets severe on the periphery. ${\Delta}T$ between the right and left side of the body in experimental group is larger than that of control group. 2. ${\Delta}T$ between the cheeks and the hypogastric in the experimental group is significantly larger than that of the control group, which shows cold face. 3. ${\Delta}T$ between the upper arms and the palms in the experimental group is significantly larger than that of the control group, which shows cold hand. 4. ${\Delta}T$ between the thighs and the knees in the experimental group is significantly larger than that of the control group, which shows cold knee. 5. ${\Delta}T$ between the thighs and the feet in the experimental group is significantly larger than that of the control group, which shows cold foot. 6. ${\Delta}T$ between the hip and the lower back in the experimental group is significantly larger than that of the control group. That shows the Lower back is warmer than the hip. 7. ${\Delta}T$ between the upper and the lower abdomen in the experimental group is significantly larger than that of the control group, which shows cold hypogastric.

  • PDF

Effect of Post Weld Heat Treatment for Crystal Orientation Distribution on Friction Stir Welds of Al-Mg-Si Series Aluminum Alloy Sheets (Al-Mg-Si계 알루미늄 합금 판재 마찰교반접합부의 결정 방위 분포에 대한 용접후열처리의 영향)

  • Lee, Kwang-Jin
    • Journal of Welding and Joining
    • /
    • v.27 no.6
    • /
    • pp.62-67
    • /
    • 2009
  • Friction stir welding (FSW) was carried out for Al-Mg-Si series aluminum alloys which are being used for automotive body structure. Consequently, Post weld heat treatment (PWHT) was applied to the friction stir welds to evaluate the effect of the paint baking process which is one of the automotive fabrication process on friction stir welded zone (FSWZ) in 443K for 1.2Ks. Grain structure and its crystal orientation distribution was measured about both the as welded specimens and the post weld heat treated specimens. An optical microscope (OM) and an field emission scanning electron microscope (FE-SEM) was used for observing the grain structure and measuring its crystal orientation distribution, respectively. Changes on the grain structure and its crystal orientation distribution were not detected. From the present results, it was confirmed that the paint baking process after FSW do not affect on the grain structure and its crystal orientation distribution of FSWZ. The comprehensive investigations will be performed for various automotive aluminum alloys manufactured by different processes, in the future.

Analysis of Natural Convection Heat Transfer and Solidification of a Two-Layered Pool (2층으로 성층화된 풀 내에서의 자연대류 열전달과 고화현상에 대한 연구)

  • Kim J.;Kang K. S.;Kim S. B.;Kim H. D.
    • Journal of computational fluids engineering
    • /
    • v.6 no.1
    • /
    • pp.1-13
    • /
    • 2001
  • The natural convection heat transfer and solidification in a stratified pool are studied. The flow and heat transfer characteristics in a heat generating pool are compared between single-layered and double-layered pools. And local Nusselt number distributions on outer walls are obtained to consider thermal loads on a vessel wall. The cooling and solidification of Al₂O₃/Fe melt in a hemispherical vessel are simulated to study the mechanism of heat transfer and temperature distribution. A unstructured mesh is chosen for this study because of the non-orthogonality originated from the boundaries of double-layered pool. Interface between the layers is modeled to be fixed. With this assumption mass flux across the interface is neglected, but shear force and heat flux are considered by boundary conditions. The colocated cell-centered finite volume method is used with the Rhie-Chow interpolation to compute cell face velocity. To prevent non-physical solutions near walls in case body force is large the wall pressure is extrapolated by the way to include body force. The numerical solutions calculated by current method show that averaged downward heat flux of the double-layered pool increases compared to single-layered pool and maximum temperature occurs right below the interface of the layers.

  • PDF

THEORITICALL ANALYSIS OF TEMPERATURE DISTRIBUTION IN TWO-DIMENSIONAL FIELD USING F.E.M (유한요소법을 이용한 2차원 Field 내의 온도분포의 이론적 해석)

  • Kim, N.H.;Choi, C.S.;Choi, H.H.;Hong, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1292-1295
    • /
    • 1987
  • In noninvasive temperature measurement within body, this paper is presented temperature measurement method in security and with effect from Applicator by electromagnetic, and it is analyzed heat generation quantity or temperature rise distribution by computer simulation within body. In this paper, two-dimensional model is considered and temperature distribution produced by RF capacitive heating system is analyzed by using Finit Element Method (F.E.M). A passibility of temperature distribution control is examined based on the position and size of Applicator.

  • PDF

Preliminary Study on Usual Cold or Heat as a Risk Factor for Hypertension in an University Faculty (일개 대학 교직원 집단에서 고혈압의 위험요인으로서의 평소 한열 예비 연구)

  • Jung, Kyung Sik;Kim, Yun Young;Baek, Young Hwa;Jang, Eunsu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.33 no.4
    • /
    • pp.226-232
    • /
    • 2019
  • This study was aimed to reveal that the usual cold or heat state was associated with hypertension and could be a risk. We emailed educational personnel in D university to join this study and 182 subjects participated in from March to December in 2016. The usual cold or heat diagnosis was conducted by two experts who had over 10 years expertise. The blood pressure was measured from the subjected after 10 minute rest with Jawon medical device. The hypertension was diagnosed by the guide of the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. The frequency analysis was used in general characteristics, Pearson's Correlation Coefficient analysis was conducted in among continuous variables, and chi-square test was also used between hypertension and cold or heat group. Logistic regression was analyzed to generate the odds ratios (ORs) and 95% confidence interval (CI) for hypertension. The cold score was suggested to have negative association with Body mass Index (BMI, -.374, p<.001), systolic blood pressure (-.333, p<.001), and diastolic pressure (-.261, p<.001). The heat score was analyzed to have positive association with Body mass Index (.413, p<.001), systolic blood pressure (.249, p<.001), and diastolic pressure (.156, p<.001). The distribution of the cold group (35.1%) and non-cold group (64.9%) in hypertension was significantly different (p=0.18). The distribution of the heat group (62.2%) and non-heat group (37.8%) was significantly different (p=0.27). The usual cold was associated with decreased ORs (ORs 0.405, 95% CI=0.191-0.857), and usual heat was associated with increased ORs (ORs 2.327, 95% CI=1.108-4.888). However, after adjusting body mass index, sex, and smoking, the association was not significantly different. It is possible that usual cold or heat associate with hypertension. Further study is needed to show that usual heat may be a independent risk factor for hypertension through follow up design.

Temperature Rise Test and Temperature Distribution Analysis of Pole Mount Mold Transformer with One-body Molding (일체형 주상용 몰드 변압기의 온도분포 및 특성 비교)

  • Cho, Han-Goo;Lee, Un-Yong;Kang, Tack-Sou;Choi, In-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1154-1159
    • /
    • 2006
  • The mold transformers have been widely used in underground substations of large building and have some advantages when compared with oil-transformer. Those advantages are low fire risk, environmental compatibility, compact size and high reliability. The mold transformer is generally known to have cooling duct between low voltage and high voltage coil. To achieve better compact structure and low loss, mold transformers made by one body molding method has been developed. Nevertheless, such kinds of transformer need better cooling method because heat radiation between each winding is still of problem. The life of transformer is significantly dependent on the thermal behavior in windings. Many designers have calculated temperature distribution in transformers and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, the temperature distribution analysis of 100 kVA pole mold transformer for power distribution were investigated by FEM program and the thermal analysis results were compared with temperature rise test.

Thermal Analysis According to Material of Manifold (매니폴드 재질에 따른 열 해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.3
    • /
    • pp.33-37
    • /
    • 2009
  • Manifold could apply stainless steel with light weight and durability to improve fuel efficiency at automotive industry. This study is analyzed and compared by heat transfer and deformation according to the materials of cast iron and stainless steel. The heat transfer at manifold of cast iron at the distribution of heat temperature is more than that of stainless steel. But the value of maximum heat deformation in case of stainless steel is 1.5 times as great as that in case of cast iron. The value of maximum heat equivalent stress in case of stainless steel is 2.7 times as great as that in case of cast iron. This maximum stress at manifold is shown at the part assembled with engine body.

  • PDF

Real Time Estimation in 1-Dimensional Temperature Distribution Using Modal Analysis and Observer (모드해석과 관측기를 이용한 1차원 온도분포의 실시간 예측)

  • An, Jung-Yong;Park, Yeong-Min;Jeong, Seong-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.2
    • /
    • pp.195-201
    • /
    • 2001
  • An inverse heat conduction problem(IHCP) arises when unknown heat fluxes and whole temperature field are to be found with temperature measurements of a few points. In this paper, observers are proposed as solution algorithm for the IHCP. A 1-dimensional heat transfer problem is modeled with modal analysis and state space equations. Position of the heat source is estimated through test heat inputs and the autocorrelation among a few of temperature data. The modified Bass-Gura method is used to design a state observer to estimate the intensity of heat source and the whole temperature field of a 1-dimensional body. To verify the reliability of this estimator, analytic solutions obtained from the proposed method are compared.

A Study on the Characteristics of Perceived Temperature over the Korean Peninsula During 2007 Summer (한반도 2007년 여름철 인지온도 특성 연구)

  • Byon, Jae-Young;Kim, Jeong-Sik;Kim, Ji-Young;Choi, Byoung-Cheol;Choi, Young-Jean;Graetz, Angelika
    • Atmosphere
    • /
    • v.18 no.2
    • /
    • pp.137-146
    • /
    • 2008
  • This study examines one thermal index, perceived temperature (PT), over the Korean Peninsula during 2007 summer. Heat/cold stress has been described using air temperature and humidity for warm seasons and air temperature and wind velocity in the cold conditions, while PT is based on a heat budget model of the human body that considers air temperature, humidity, wind velocity and radiation effect regardless of climates, regions and seasons. PT is higher about $4-5^{\circ}C$ than air temperature in the summer. Humidity increases PT, while wind tends to reduces PT possibly by evaporation of water vapor. The geographical distribution of summer PT indicates that the lowest PT happened in the east central region, with the appearance of the highest PT in the inland of southern region in Korea. Although the latitudinal trend shows that PT decreases northward, inland PT is higher than that of coastal region. Compared to the heat index or the discomfort index that considers air temperature and humidity, PT represents distinctive regional characteristics of thermal comfort. The distribution of PT shows that it may be a useful thermal index for the assessment of thermal comfort or stress region in the Korean Peninsula.