• Title/Summary/Keyword: Discharge current

Search Result 1,805, Processing Time 0.039 seconds

A Clinicostastical Analysis of Genitourinary Diseases from the Nationwide Hospital Discharge Survey (전국 퇴원환자 자료분석을 통한 소아 청소년의 비뇨생식기질환의 분포)

  • Kim, Sa-Ra;Park, Hyun-Ju;Moon, Jin-Soo;Lee, Chong-Guk
    • Childhood Kidney Diseases
    • /
    • v.13 no.1
    • /
    • pp.63-74
    • /
    • 2009
  • Purpose : The current nationally representative data on inpatient care are important to make the of the national public health policy because distributions and the prevalence of diseases among children and adolescents represent the socioeconomic status of the society. The prevalence of chronic disease is increasing now in Korea as the socioeconomic condition is improving. We analyzed a part of genitourinary tract disease of the cross-sectional hospital discharge survey data in Korea collected recently to delineate the trend of genitourinary tract diseases. Methods : Korean nationwide hospital discharge survey for pediatric inpatients in the period from 2004 to 2006 was analyzed. Diagnoses in the data were coded using ICD-10 classification. Totally 826,896 cases were collected from the 85 training hospitals. Selected data of genitourinary tract diseases (belonging to N00-N99 by ICD-10) among 826,896 cases of final inpatients data were analyzed for this study. Results : Among total patients of 826,896, diseases of the genitourinary system accounted for 4.1%. and four diagnostic categories accounted for 92.8%. These were other diseases of the urinary system (N30-39), 45.8%, disease of male genital organs (N40-51),19.1%, glomerular diseases (N00-08), 17.3%, renal tubulo-interstitial diseases (N10-16), 10.6%, respectively. Conclusion : Genitourinary tract disease in pediatric inpatient shows decreasing tendency but the prevalence of chronic diseases is increasing in Korea as the socioeconomic condition is improving. For further comprehensive analysis, regular and organized nationwide survey should be performed. Development of a new data collecting system will improve the performance of such nationwide survey.

Initial Charge/Discharge of $LiCoO_2$ Composite Cathode with Various Content of Conductive Material for the Lithium ion Battery (리튬이온전지용 $LiCoO_2$정극의 도전재료에 따른 초기 충방전 특성)

  • Doh Chil-Hoon;Moon Seong-In;Yun Mun-Soo;Yun Suong-Kyu;Yum Duk-Hyung;Park Chun-Jun
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.3
    • /
    • pp.123-129
    • /
    • 1999
  • Initial electrochemical characteristics of $LiCoO_2$ electrode for lithium ion battery with various content of super s black as conductive material were evaluated through the charge/discharge with the potential range of 4.3V to 2.0V versus $Li^+/Li^+$. The rate of C/4 and C/2 by the 3 electrode test cell composed with an electrolytic solution of 1 mol/l $LiPF_6/EC+DEC(1:3\;by\; weight)$. Lithium was used as reference electrode. High impedance charge behavior was observed at early stage of charge. In the case of $3\%w/w$ of super s black as conductive material, the specific resistance of the high impedance releasing was $3.82\;{\Omega}\;{\cdot}\;g-LiCoCo_2$ at the current density of $0.5 mA/cm^2$, which corresponds 7 times of the specific resistance of electrode $(0.728 g-LiCoO_2)$. At second charge, the specific resistance of the high impedance releasing was 63 mn · g-Lico02, which corresponds 12eio of the specific resistance of electrode and only $1.7\%$ of that of the first charge. The first charge and discharge specific capacities at C/4 rate were 160-161 and $153\~155mAh/g-LiCoO_2$, respectively, to lead $95.4\~96.4\%$ of coulombic efficiencies and ca. $6 mAh/g-LiCoO_2$ of initial irreversible specific capacity. Specific resistance at the end of charge and rest showed low value at content of super s black between 2 and $7\%w/w$, which agreed with characteristics of irreversible specific capacity. Capacity densities were reduced by the increasing the content of conductive material. They were 447 and 431mAh/ml when 2 and $2.9\%w/w$ of super s black were used, respectively, at the rate of C/4.

The Effect of Different Membranes on the Performance of Aqueous Organic Redox Flow Battery using Methyl Viologen and TEMPOL Redox Couple (다양한 멤브레인을 적용한 메틸 바이올로겐과 템폴 활물질 기반 수계 유기 레독스 흐름 전지 성능 평가)

  • Park, GyunHo;Lee, Wonmi;Kwon, Yongchai
    • Korean Chemical Engineering Research
    • /
    • v.57 no.6
    • /
    • pp.868-873
    • /
    • 2019
  • In this study, the evaluation of performance of AORFB using methyl viologen and TEMPOL as organic active materials in neutral supporting electrolyte (NaCl) with various membrane types was performed. Using methyl viologen and TEMPOL as active materials in neutral electrolyte solution, the cell voltage is 1.37V which is relatively high value for AORFB. Two types of membranes were examined for performance comparison. First, when using Nafion 117 membrane which is commercial cation exchange membrane, only the charge process occurred in the first cycle and the single cell couldn't work because of its high resistance. However, when using Fumasep anion exchange membrane (FAA-3-50) instead of Nafion 117 membrane, the result was obtained as the totally different charge-discharge graphs. When current density was $40mA{\cdot}cm^{-2}$ and cut off voltage range was from 0.55 V to 1.7 V, the charge efficiency (CE) was 97% and voltage efficiency (VE) was 78%. In addition, the discharge capacity was $1.44Ah{\cdot}L^{-1}$ which was 54% of theoretical capacity ($2.68Ah{\cdot}L^{-1}$) at $10^{th}$ cycle and the capacity loss rate was $0.0015Ah{\cdot}L^{-1}$ per cycle during 50 cycles. Through cyclic voltammetry test, it seems that this difference in the performance between the full cell using Nafion 117 membrane and Fumasep anion exchange membrane came from increasing resistance due to chemical reaction between membrane and active material, not the capacity loss due to cross-over of active material through membrane.

The Fabrication of the Single Crystal Wire from Cu Single Crystal Grown by the Czochralski Method and its Physical Properties (Czochralski법을 이용한 금속 단결정의 성장과 구조적, 전기적 성질에 관한 연구)

  • Park, Jeung-Hun;Cha, Su-Young;Park, Sang-Eon;Kim, Sung-Kyu;Cho, Chae-Ryong;Park, Hyuk-K.;Kim, Hyung-Chan;Jeong, Myung-Hwa;Jeong, Se-Young
    • Korean Journal of Crystallography
    • /
    • v.16 no.2
    • /
    • pp.141-148
    • /
    • 2005
  • It is well known that the general metals have a lot of grain boundaries. The grain boundaries play a negative role to increase the resistivity and to decrease the conductivity. The small resistivity and the large conductivity have been a goal of the material scientists, and no signal noise, perfect signal transfer, and the realization of the real sound are the dream of electronic engineers and audio manias. Generally, oxygen free copper (OFC) and Ohno continuous casting (OCC) copper cables have been used for the purpose of the precise signal transfer and low noise. However they still include a lot of grain boundaries. In our study, we have grown the single crystal by the Czochralski method and succeeded to produce single crystal wires from the crystal in the dimension of $0.5{\times}0.5{\times}2500mm$. The produced wire still possesses very good single crystal properties. We observed the structure of the wire, and measured the resistance and impedance. Glow Discharge Spectrometer (GDS) was used for analyzing the compositions of copper single crystals and commercial copper. Current-Voltage curve, resistance, total harmonic distortion and speaker frequency response were measured for comparing electrical and acoustic properties of two samples.

Deposition Characteristics of the Sandbar and Estimation of the Mass Transport Flux in the Nakdong Estuary (낙동강 하구역의 사주 퇴적특성과 물질수송플럭스 산정)

  • YOON RAN-SAM;LEE IN-CHEOL;Ryu CHEONG-RO
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.131-137
    • /
    • 2004
  • This paper is intended as an investigation of the deposition characteristics and mass transport flux estimation in the Nakdong estuary. In order to understand the effects of the tidal current circulation which influenced to an estuary terrain change, the seawater circulation calculation by the use of 2D numerical model for the three cases of without riverflow, mean and flood riverflow quantity condition practiced and each sectional net-flux of water quantity between sandbars(so called, dung) estimated. It may be that an estuary terrain change due to the large scale construction and reclamation at the Nakdong estuary influence to the long-time deposition characteristics. by the revim for the old research, we know that the development of the local sandbars has been moved toward the east-side from the west-side estuary area after the construction of the Nakdong river dike, at present the strong-acted location is the Bakhap-dung of the front sea of Tadea. The seawater circulation pattern at this large scale area of tidal flat bring on a change due to the water quantity outflowing from the Nakdong river. Base on the calculated results for the section net-flux of water quantity, we see that the accumulating action very strong at the local sea around Jangjado, Bakhapdung and Tadae for the case of flood riverflow quantity condition, but at the local sea around Jinudo for the another cases. Consequently, it is emphasized that in the Nakdong estuary the main sensitive regions which influenced from the discharge of riverflow were the local sea around Jangjado, Bakhapdung, Tadae and Jinudo.

  • PDF

Effects of Sequential Application of Superficial Cold and Heat on Pain, Patient Satisfaction with Pain Control, Comfort Level and Subjective Response after Spine Surgery (순차적 냉·온 요법이 척추 수술 후 통증과 통증 조절 만족도, 안위, 주관적 반응에 미치는 효과)

  • Kim, Jeoung Hee;Lhim, Seung Chul;Roh, Sung Woo;Lee, Sun Jin;Ko, Young Mi;Kim, Yeo Ok;Shin, Yong Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.23 no.2
    • /
    • pp.184-193
    • /
    • 2016
  • Purpose: The aims of the current study were to evaluate the effects of superficial cold and heat after spine surgery on pain, satisfaction with pain control and comfort level, and to identify subjective responses and adverse effects. Methods: A prospective, single-blind, randomized controlled trial was utilized. The intervention group (n=36) received superficial cooling until the wound drain was removed and thereafter followed by superficial heating until discharge, while the control group (n=34) received only superficial cooling until wound drain was removed. Data were collected from August 4 to November 11 2014. Results: There was significant difference in pain according to time within groups (F=71.87, p<.001). However, we found no difference in pain between groups. The intervention group reported higher patient satisfaction with pain control (4 vs 3, z=-2.83, p=.005) and higher comfort level (5 vs 4, z=-4.12, p<.001) than the control group. Conclusion: Results indicate that sequential application of superficial cold and heat is a useful method in clinical practice for management of pain after spine surgery.

Design of Automotive Fuel Tank for Preventing Liquid Carry Over Using Taguchi Method and Approximate Optimization (다구치 방법과 근사최적설계를 이용한 자동차 연료탱크의 연료 넘침 방지 시스템 설계)

  • Park, Gyu-Byung;Lee, Yongbin;Cho, In-Geun;Choi, Dong-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.8
    • /
    • pp.1059-1067
    • /
    • 2013
  • Automotive fuel tank is generally divided into two parts: main frame and assembly parts. While the car is running, valves are used to prevent liquid carry over and to discharge evaporated gas from the fuel tank. However, current fuel tank designs focus on the gas ventilation or secured location. In this study, the location of the parts used to prevent liquid carry over within the fuel tank is evaluated during an optimal design process. To develop this design process, an approximate optimization is applied. Through the optimal design process, the optimal valve location in fuel tank is determined and the approximate optimization is validated by the Taguchi method. Finally, the optimized valve location is used to reduce the development cost and time and to contribute toward improved automobile quality owing to enhanced reliability.

Study on LED Low-cost Control Technology Associated with User Information Situation (사용자 정보상황 연계형 LED 절감제어기술에 관한 연구)

  • Jang, Tae-Su;Hong, Geun-Bin;Kang, Eun-Young;Kim, Yong-Kab;Kim, Byun-Gon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.743-744
    • /
    • 2012
  • LED digital control convergence technology is receiving attention. It enables to analyze lighting and living environments by recognizing user information and situations through a signal process system composed of a multi-functional composite sensor's module. LED lighting is higly efficient, long-lived, environmentally, and is possible to converge with communication, and receiving as a next-generation general lighting that will replace a florescent light including the light bulb. The proposed system is an intelligent LED control system that uses solar light. This study is about a lighting control technology associated with user-estimated information/situation and related low-cost technology. Also, this study aims to embody emotional lighting by appropriately lighting 10% of the discharge current with supplementary colored LED according to the surrounding environment.

  • PDF

Developing Equipment to Detect the Deterioration Status of 6.6kV Power Cables in Operation at Power Station (발전소에서 운전 중인 활성 6.6kV 전력 케이블의 고장상태를 파악하는 장치의 개발)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.197-203
    • /
    • 2014
  • The technology to predict and prevent an accident of the cable system in power station is required. The techniques of inactivated diagnosis, partial discharge and $tan{\delta}$, have been adopted to diagnoze the operating characteristics of cables, but it is not so easy to find out problems in cables in an inactive state before the cable accident happens. In this paper, we did a research on the 6.6kV high-power cables, installed at Korean Western Power Station Co., Ltd. in order to diagonize the cables, playing a major role at the station. We have developed an equipment to measure an insulation resistance based on the temperature and current of the cable. By installing the system in a power station, we could find abnormal status for evaluation of the lifetime. In the short term, by analyzing the data, we apply the research result to the diagnosis and evaluation of the 6.6kV power cables. In the long run, however, we plan to reduce the cost of the installation and operation of cable systems at power stations.

Electrochemical Characteristics of Silicon/Carbon Anode Materials using Petroleum Pitch (석유계 피치를 사용한 실리콘/탄소 음극소재의 전기화학적 특성)

  • Lee, Su Hyeon;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.56 no.4
    • /
    • pp.561-567
    • /
    • 2018
  • In this study, the electrochemical characteristics of Silicon/Carbon anode materials were analyzed to improve the cycle stability of silicon as an anode materials of lithium ion battery. Porous silicon was prepared from TEOS by the $st{\ddot{o}}ber$ method and the magnesiothermic reduction method. Silicon/Carbon anode materials were synthesized by varying the mass ratio between porous silicon and pitch. Physical properties of the prepared Silicon/Carbon anode materials were analyzed by XRD and TGA. Also the electrochemical performances of Silicon/Carbon anode materials were investigated by constant current charge/discharge, rate performance, cyclic voltammetry and electrochemical impedance tests in the electrolyte of $LiPF_6$ dissolved in organic solvents (EC : DEC = 1 : 1 vol%). The Silicon/Carbon anode composite (silicon : carbon = 5 : 95 in weight) has better capacity (453 mAh/g) than those of other composition cells. The cycle performance has an excellent capacity retention from 2nd cycle to 30th cycle.