• Title/Summary/Keyword: Discharge Control

Search Result 1,425, Processing Time 0.03 seconds

Water Resources Utilization Pattern of JangSung Reservoir (장성호 수자원 이용 패턴)

  • Yoon, Kwang-Sik;Han, Kuk-Heon;Yoon, Suk-Gun;Jung, Jae-Woon
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.291-294
    • /
    • 2003
  • The Water resources utilization pattern of Jangsung reservoir was studied. The observed precipitation and existing reservoir operation data such as irrigation amount, reservoir storage, river maintenance requirement, flood control discharge were collected for ten years period and analyzed. Major findings of this study are as follows: The observed average, minimum, maximum annual precipitation were 905.1mm, 1,977.3mm, 1,554.3mm during study period, respectively. The average annual irrigation amount was 554.5mm, irrigation amount of drought years of '92 and '94 was 604.6mm, 679.2mm, respectively. However, irrigation amount of extended drought year '95 was 384.9mm. It showed that supplying capacity of Jangsung reservoir was limited when consecutive 2 year drought occurred. The main water resources usage of Jangsung reservoir was irrigation, but flood control discharge exceed irrigation amount exceptionally when high precipitation occurred. The reservoir operation record revealed that discharge for river maintenance was delivered even drought years.

  • PDF

A Performance Testing Device of Drycell (건전지의 성능평가 장치)

  • Jeong, Heon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.2
    • /
    • pp.171-175
    • /
    • 2011
  • In this paper, I have developed a high-speed and high-resolution measuring device in order to check the performance of drycell. The system is developed for the drycell manufacturing plant. Measuring time is one of key factors to inference on the production speed. So the developed system is designed to generate the classified result up to 1200ea/min. In the other words, each product can be classified within 25ms. There have been many studies to estimate both state of charge as well as state of health, such as OCV (Open Circuit Voltage), SC (Short Circuit) and measuring impedance with frequency pulse. But those methods take a few second due to surface discharge. To overcome the phenomenon, I developed the method to engage the reverse current to two electrodes of battery. As a result, I could achieve to measure the indigenous capacity without the problem of surface discharge.

The improved characteristics of the Stand-alone PV system (소규모 독립형 태양광 발전 시스템의 특성 개선)

  • Kang, Sin-Young;Lee, Yang-Guy;Kim, Kwang-Heon
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.58-62
    • /
    • 2002
  • The MPPT methods is used to get the maximum energy from the limited size of a photovoltaic array. This study deals with the suitable MPPT method of solar lighting lamp and the improved charge and discharge characteristics. So we proposed the control algorithm for stand-alone photovoltaic array(SPVS). The result of experiment is presented the improved charge characteristics and the charge and discharge times reduction, the depth of discharge control. so, the system stabilization goes up. It is possible economical effect to apply for solar lighting lamp used photovoltaic array

  • PDF

Water Pollution and Economic Growth in Western China

  • Lu, Xing;Lei, Shi;Weili, Ye
    • Environmental and Resource Economics Review
    • /
    • v.16 no.3
    • /
    • pp.629-641
    • /
    • 2007
  • Chinese government has implemented the West Development Strategy since 1999 to boost the region's growth and prevent the environmental degradation. Until now, the regional economy and living standard in Western China have been greatly improved, while it also indicated by the State Council that the ecological environment still deteriorated with part improvement, and pressure of water shortage increased. The paper focus on the relationship of GDP per capita and the volume of industrial waste water discharge of all the 12 provinces in Western China from 1989 to 2004, by the expanded EKC model in the cubic form. Results show that they mainly have down trend in the whole sample space but small up trend in the recent years. That means controlling of industrial wastewater discharge is still an important task to be insisted in the Western China.

  • PDF

Some Problems of the Partial Discharge Burning Time

  • Kinsht Nikolay V.;Katz Marat A.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.319-323
    • /
    • 2006
  • The problem of the partial discharge (PD) extinction is investigated. The transient process takes place in a small spherical inclusion which is located in the dielectric. Both the losses caused by polarization and ohmic losses as the dielectric parameters are taken into account. From the inclusion standpoint the dielectric is considered as an active two-pole element (equivalent generator) and inclusion represents by own current-voltage curve. PD extinction voltage was shown to depend on the polarization loss tangent.

Charged Cable Model (CCM) ESD Damage to ECU (Charged Cable Model (CCM) 정전기 방전(ESD)에 의한 전자제어장치의 손상)

  • Ha, MyongSoo;Jung, JaeMin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.2
    • /
    • pp.159-165
    • /
    • 2013
  • ESD damage by Charged Cable Model (CCM) is introduced. Due to its own impedance characteristic unlike Human Body Model (HBM) or Machine Model (MM) electric component can be destroyed even though it is located after typical protection circuit. Possible mechanism of ESD damage to automotive electric control unit (ECU) in vehicle environment by CCM discharge was investigated. Based on investigation, field-returned vehicle whose ECU is expected to be damaged by CCM discharge was tested to reproduce it and similar electric component destruction inside ECU was observed. Suggestions to reduce the possibility of ESD damage by CCM are introduced.

Bidirectional Pulse Power Supply for Dielectric Barrier Discharge (유전체 장벽 방전을 위한 양방향 펄스 전원장치)

  • Shin, Wan-Ho;Hong, Won-Seok;Jeoung, Hwan-Myoung;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1521-1523
    • /
    • 2005
  • High voltage plasma power supply was adopted to control polluted gases and an ozone generation. Bidirectional pulse power supply consisted of power semiconductor switch devices, a high voltage transformer, and a control board adapted switching method. Plasma power supply with sinusoidal bidirectional pulse, which has output voltage range of 0-20kV and output frequency range of 1kHz-20kHz, is realized. Using proposed system, pulsed high voltage/high frequency discharges were tested in a DBD(dielectric barrier discharge) reactor, and the spatial distribution of a glow discharge was observed. The system showed stable operational characteristics, even though the voltage and the frequency increased. Above features were verified by experiments.

  • PDF

Auto-Leveling of HID Headlamp Using Preview Control

  • Yang, Boojoong;Kang, Heeyong;Yang, Sungmo
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.11
    • /
    • pp.1404-1411
    • /
    • 2002
  • A newly developed high intensity discharge (HID) automotive headlamp results in a high luminous gradient at the cutoff line, and proves the superior concept in safer and more com-fortable nighttime driving. This new headlamp technology Provides drivers expanded night vision by a significantly improved light pattern. However, the HID headlamp may dazzle other traffics during traversing a rough road or encountering an unexpected bump. To resolve this problem, an automatic headlamp leveling device is necessary. A preview control is presented for the design of the leveling system. The proposed control algorithm is capable of attenuating a dynamic glare which is one of the major detractors to a driving in dark roads. Computer simulations using ADAMS are carried out to confirm the effectiveness on the control system.

Alternating Battery Discharge Method Using Discharge Time Balancing (방전 시간 밸런싱을 사용한 배터리 교대 방전 기법)

  • Lee, Jong-Bae;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.366-370
    • /
    • 2015
  • This paper proposes an alternating battery discharge method by balancing discharge time of battery cells, which significantly increases battery lifetime. In the conventional method, several battery cells are alternately discharged to make battery recovery effect, and this increases battery lifetime. In this case, there are some overlap intervals where several battery cells are ON to avoid system power cut-off, but this makes several problems due to the voltage differences of battery cells. To mitigate these problems, discharge time of battery cells are controlled to make battery cell voltages as equal as possible. Measurements show that the battery lifetime is exxtended by 19.2% in the proposed method.

The numerical simulation on variation of phytoplankton maximum region in the estuary of Nakdong river -II. The numerical simulation on variation of phytoplankton maximum region- (낙동강 하구지역의 식물플랑크톤 극대역 변동에 관한 수직시뮬레이션 -II. 식물플랑크톤 극대역 변동의 수치시뮬레이션-)

  • 이대인
    • Journal of Environmental Science International
    • /
    • v.9 no.5
    • /
    • pp.375-384
    • /
    • 2000
  • It is very important to interprete and simulate the variation of phytoplankton maximum region for the prediction and control of red tide. This study was composed of two parts first the hydrodynamic simulation such as residual current and salinity diffusion and second the ecological simulation such as phytoplankton distribution according to freshwater discharge and pollutant loads. Without the Nakdong river discharge residual current was stagnated in inner side of this estuary and surface distribution of salinity was over 25psu. On the contrary with summer mean discharge freshwater stretched very far outward and some waters flowed into Chinhae Bay through the Kadok channel and low salinity extended over coastal sea and salinity front occurred. From the result of contributed physical process to phytioplankton biomass the accumulation was occurred at the west part of this estuary and the Kadok channel with the Nakdong river discharge. When more increased input discharge the accumulation band was transported to outer side of this estuary. The frequently outbreak of red tide in this area is caused by accumulation of physical processes. The phytoplankton maximum region located inner side of this estuary without the Nakdong river discharge and with mean discharge of winter but it was moved to outer side when mean discharge of the Nakdong river was increased. The variation of input concentration from the land loads was not largely influenced on phytoplankton biomass and location of maximum region. When discharge was increased phytoplankton maximum region was transferred to inner side of the Kadok channel. ON the other hand when discharge was decreased phytoplankton maximum region was transferred to inner side of this estuary and chlorophyll a contents increased to over 20$\mu\textrm{g}$/L Therefore if any other conditions are favorable for growth of phytoplankton. decreas of discharge causes to increase of possibility of red tide outbreak.

  • PDF