• Title/Summary/Keyword: Direct Loss

Search Result 907, Processing Time 0.026 seconds

Analysis of Insulation Life Loss due to Fault Occurrence of TP Cable for HVDC Systems (고장 발생에 따른 HVDC 시스템용 TP 케이블의 절연체 수명 손실 분석)

  • Woo-Hee Jeong;Jae-In Lee;Seok-Ju Lee;Minh-Chau Dinh
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.29 no.4
    • /
    • pp.55-66
    • /
    • 2024
  • In order to safely use thermoplastic (TP) cables in high-voltage direct current (HVDC) systems, it is necessary to analyze the life loss rate of the cable due to system fault that may occur during operation through various research and tests. In this paper, we analyzed the insulation life loss rate of TP cable according to the type of faults that may occur during HVDC system operation. Electric power due to fault was applied to the TP cable model, and the life loss rate of the insulator was analyzed by applying the Arrhenius-Inverse Power Model (IPM) based on the analysis results through the 2D finite element method. As a result of the analysis, the life loss rate of the insulator was highly influenced by the electric field strength, and the loss rate was highest inside the insulator when a fault occurred. These results can be used as important characteristics in the early design stage for commercialization of TP cables.

An engineering-based assessment methodology on the loss of residential buildings under wind hazard

  • Li, Mingxin;Wang, Guoxin
    • Wind and Structures
    • /
    • v.30 no.1
    • /
    • pp.1-13
    • /
    • 2020
  • The loss prediction and assessment during extreme events such as wind hazards is always crucial for the group low-rise residential buildings. This paper analyses the effect of variation in building density on wind-induced loss for low-rise buildings and proposes a loss assessment method consequently. It is based on the damage matrices of the building envelope structures and the main load-bearing structure, which includes the influence factors such as structure type, preservation degree, building density, and interaction between different envelope components. Accordingly, based on field investigation and engineering experience, this study establishes a relevant building direct economic loss assessment model. Finally, the authors develop the Typhoon Disaster Management System to apply this loss assessment methodology to practice.

Transmission Loss Characteristics of the Panel Type Silencer (패널형 소음기의 투과손실 특성 연구)

  • 서상현;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.178-183
    • /
    • 2003
  • This paper deals with transmission loss characteristics of the panel type silencer to control low frequency noise. The panel type silencer is composed of many Helmholtz resonators by side branch. Each resonator has high transmission loss on the narrow band of its resonance frequency. Direct arrangement of the resonators increases mainly the magnitude of transmission loss. If we arrange the resonators in a row, the peak and band of transmission loss are increased. This makes the resonator array to have high transmission loss in the broader band. Using this idea, we design a silencer that has broader band characteristics and smaller volume.

  • PDF

Torque Estimation Using Precise Calculations of Inductance and Iron loss Mathematization

  • Cho, Gyu-Won;Kim, Gyu-Tak
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.300-305
    • /
    • 2013
  • The torque was calculated with inductance and iron loss. Because the linkage flux can change the inductance, and q-axis current can change the iron loss. Therefore, precise estimation of torque can achieve with the inductance and iron loss detail calculations. So, in this paper, the d, q-axis inductance was verified through CVCT(Current Vector Control Test) and DCT(Direct Current Test). Also in the iron loss calculation, the prediction of all areas of current magnitude, phase angle and speed was very difficult. And LUT(Look-Up Table) was spent time and resource largely. Therefore, iron loss mathematization was proposed according to current magnitude, phase angle and speed. Also, characteristics of IPMSM were comprised of analyzed and experimental values.

Drying Efficiency of Betung Bamboo Strips (Dendrocalamus asper) Based on Different Solar Drying Oven Designs

  • Ihak SUMARDI;Anggit Kusuma Dewan DARU;Alfi RUMIDATUL;Rudi DUNGANI;Yoyo SUHAYA;Neil PRIHANTO;Rudi HARTONO
    • Journal of the Korean Wood Science and Technology
    • /
    • v.52 no.1
    • /
    • pp.1-12
    • /
    • 2024
  • Betung bamboo (Dendrocalamus asper) is used as a building and handicraft material in Indonesia; however, bamboo needs to be dried to increase its stability. This study aimed to evaluate the efficiency of drying bamboo using solar energy and different drying oven designs. The betung bamboo pieces were dried using a direct solar dryer (direct drying) and an indirect solar dryer (indirect drying) and then the decrease in levels that occurred based on the relative humidity (RH) and temperature values achieved in the two dryers were compared. The highest average temperature in the direct indirect drying oven compartment was 60.1 ± 13.1℃ with 19.9 ± 16.4% RH and 60.2 ± 11.9℃ with 19.5 ± 15.5% RH, respectively. The drying defect in indirect drying was lower than that in direct drying, and indirect drying had a 61.7% greater average water loss than direct drying with significant difference (95%, analysis of variance) based on water loss/compartment volume parameters. Thus, the solar drying oven can be used to air-dry bamboo (14%) for 7 d from an initial moisture content of 70%-80% in bamboo strips. The results of this research can be used for small-scale bamboo processing industries that have limited use of electrical energy with quite good results.

Direct Pars Repair Surgery Using Two Different Surgical Methods : Pedicle Screw with Universal Hook System and Direct Pars Screw Fixation in Symptomatic Lumbar Spondylosis Patients

  • Shin, Myung-Hoon;Ryu, Kyeong-Sik;Rathi, Nitesh Kumar;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.1
    • /
    • pp.14-19
    • /
    • 2012
  • Objective : The authors performed a retrospective study to assess the clinical and radiological outcome in symptomatic lumbar spondylolysis patients who underwent a direct pars repair surgery using two different surgical methods; pedicle screw with universal hook system (PSUH) and direct pars screw fixation (DPSF), and compared the results between two different treated groups. Methods : Forty-seven consecutive patients (PSUH; 23, DPSF; 15) with symptomatic lumbar spondylolysis who underwent a direct pars repair surgery were included. The average follow-up period was 37 months in the PSUH group, and 28 months in the DPSF group. The clinical outcome was measured using visual analogue pain scale (VAS) and Oswestry disability index (ODI). The length of operation time, the amount of blood loss, the duration of hospital stay, surgical complications, and fusion status were also assessed. Results : When compared to the DPSF group, the average preoperative VAS and ODI score of the PSUH group were less decreased at the last follow-up; (the PSUH group; back VAS : 4.9 vs. 3.0, leg VAS : 6.8 vs. 2.2, ODI : 50.6% vs. 24.6%, the DPSF group; back VAS : 5.7 vs. 1.1, leg VAS : 6.1 vs. 1.2, ODI : 57.4% vs. 18.2%). The average operation time was 174.9 minutes in the PSUH group, and 141.7 minutes in the DPSF group. The average blood loss during operation was 468.8 cc in the PSUH group, and 298.8 cc in the DPSF group. The average hospital stay after operation was 8.9 days in the PSUH group, and 7 days in the DPSF group. In the PSUH group, there was one case of a screw misplacement requiring revision surgery. In the DPSF group, one patient suffered from transient leg pain. The successful bone fusion rate was 78.3% in the PSUH group, and 93.3% in the DPSF group. Conclusion : The present study suggests that the technique using direct pars screw would be more effective than the method using pedicle screw with lamina hook system, in terms of decreased operation time, amount of blood loss, hospital stay, and increased fusion success rate, as well as better clinical outcome.

Analysis on Core Loss of Brushless DC Motor Considering Pulse Width Modulation of Inverter

  • Kim, Ki-Chan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1914-1920
    • /
    • 2014
  • In this paper, characteristics of blushless direct current (BLDC) motor including core loss are analyzed considering pulse width modulation (PWM) of inverter. Input voltage of BLDC motor due to PWM is calculated considering duty ratio and carrier frequency of inverter in order to control torque or speed of BLDC motor. For the calculation of core loss, the input current with harmonics due to PWM voltage is calculated by using equivalent circuit model of BLDC motor according to switching pattern and carrier frequency. Next, core loss is analyzed by inputting the currents as a source of BLDC motor for FEM. Characteristics including core loss are compared with ones without PWM waveform according to reference speed.

Path Loss Characteristics in Subway Platform at 2.45GHz Band (2.45GHz 대역의 지하철 플랫폼에서 경로손실 특성)

  • 최낙일;공민한;강영진;송문규
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.318-321
    • /
    • 2003
  • In this paper, path loss and delay profile characteristics are measured in the subway platform. To evaluate the fading characteristics of the measured signals, the standard deviations are computed. The standard deviation is bigger for shorter distance. The shorter the distance, the bigger the phase difference between direct wave and reflected waves according the distance, which results in heavy fading. To compute the path loss according to distance, the average values of path loss exponent(n) is evaluated. The path loss exponents measured in the subway environment for Omni-VP(omni-directional vertical polarization) antenna and CP(circular polarization) antenna are 1.418 and 1.680, respectively, which are considerably less than 2.0, the free space path loss exponent.

  • PDF

A Study on the Scope of Claimable Loss for Damage: Focused on the CISG and the PICC (국제상거래에서 손해배상청구가 가능한 손해의 범위: CISG와 PICC를 중심으로)

  • Cho, Hyun-Sook
    • Korea Trade Review
    • /
    • v.43 no.4
    • /
    • pp.51-68
    • /
    • 2018
  • This study examined the scope of damages resulting from types of loss under the CISG and the PICC(2016). The CISG and PICC stipulate the rights of aggrieved parties to recover losses under the full compensation principle, but the PICC features more specific provisions regarding damages compared to the CISG. Therefore the PICC might provide practical insight resolving problems concerning damages under the CISG. There are direct and incidental losses, consequential losses, lost profit, and loss of chance that can be claimed by aggrieved parties under the CISG or the PICC but the scope of claimable losses differs by cases. For example, even though there are no specific clauses in the CISG or the PICC, some losses might include based on the requisite of damage under CISG or PICC. Therefore, it is important to know standards in which losses are covered by these agreements. In conclusion, related parties who engage in international trade should understand the requisite and limitation of damages, and need to clearly define specific losses that might not be governed under the CISG or the PICC.

  • PDF

Air-Water Test on the Direct ECC Bypass During LBLOCA Reflood Phase with DVI : UPTF Test 21-D Counterpart Test

  • Yun, Byong-Jo;Kwon, Tae-Soon;Song, Chul-Hwa;Euh, Dong-Jin;Park, Jong-Kyun;Cho, Hyoung-Kyu;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.33 no.3
    • /
    • pp.315-326
    • /
    • 2001
  • Direct ECC bypass phenomena that occur in a reactor vessel downcomer with a Direct Vessel Injection (DVI) system during the reflood phase of a Large Break Loss-of-Coolant Accident (LBLOCA) are experimentally investigated using a transparent l/7.5 scaled down test facility of the Upper Plenum Test Facility (UPTF). A series of separate effect tests are peformed in order to investigate the mechanisms of direct ECC bypass and to find out its scaling parameters. Various flow regimes and phasic distribution in downcomer are identified and mapped, and the fraction of direct ECC bypass is measured under a wide range of air and water injection conditions. From the counterpart test of the UPTF Test 21-D, the dimensionless gas velocity ( $j^{*}$$_{g,eff}$) is derived experimentally, which is believed to be a major scaling parameter for the fraction of direct ECC bypass. And it is found out that the direct ECC bypass is greatly affected by the spreading width of ECC water film and the geometric configuration of the downcomer.r.

  • PDF