• 제목/요약/키워드: Dimensional Change Control

검색결과 200건 처리시간 0.029초

소아 편평족 환자에서 Pressure Based Customized 3-Dimensional Printing Insole의 유용성 (Effect of Pressure Based Customized 3-Dimensional Printing Insole in Pediatric Flexible Flat Foot Patients)

  • 이시욱;최정훈;권혁준;송광순
    • 대한족부족관절학회지
    • /
    • 제24권3호
    • /
    • pp.113-119
    • /
    • 2020
  • Purpose: A flatfoot that fails to form a longitudinal foot arch is a common lower limb deformity in children. This study evaluated the structural and functional effects of the insole for pediatric flexible flat foot (PFFF). Materials and Methods: Twenty-nine PFFF patients (20 boys and 9 girls, 58 feet) with bilateral symptomatic flatfoot deformities between February 2017 and May 2019 were included in this study. Sixteen patients (32 cases, study group) were treated with a pressured based 3-dimensional printing insole, and 13 patients (26 cases, control group) were followed up regularly without any treatment. Flatfoot was diagnosed by a lateral talo-first metatarsal angle of more than 4° in convex downward and talocalcaneal angles of more than 30° and a calcaneal pitch of less than 20°. The foot pressures, including the midfoot pressure, total foot pressure, and the ratio of the midfoot pressure to the total foot pressure, were evaluated by pedobarography. The clinical scores were assessed using the visual analogue scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS), and Pediatrics Outcomes Data Collection Instrument (PODCI) scores. Results: The mean age of the study group was 9.16 years, and the mean age of the control group was 7.73 years. The mean follow-up period was 16 months. The change in the lateral talocalcaneal angle was -4.664°±1.239° in the study group and -0.484°±1.513° in the control group. A significant difference in the amount of change of the lateral talocalcaneal angle was observed between the two groups (p=0.034). The midfoot pressures were similar in the two groups. Conclusion: Pressure based customized 3-dimensional printing insole in PFFF may have some effect on the hindfoot bony alignment, but it does not affect the changes in midfoot pressure.

Multi-dimensional seismic response control of offshore platform structures with viscoelastic dampers (II-Experimental study)

  • He, Xiao-Yu;Zhao, Tie-Wei;Li, Hong-Nan;Zhang, Jun
    • Structural Monitoring and Maintenance
    • /
    • 제3권2호
    • /
    • pp.175-194
    • /
    • 2016
  • Based on the change of traditional viscoelastic damper structure, a brand-new damper is designed to control simultaneously the translational vibration and the rotational vibration for platforms. Experimental study has been carried out on the mechanical properties of viscoelastic material and on its multi-dimensional seismic response control effect of viscoelastic damper. Three types of viscoelastic dampers with different shapes of viscoelastic material are designed to test the influence of excited frequency, strain amplitude and ambient temperature on the mechanical property parameters such as circular dissipation per unit, equivalent stiffness, loss factor and storage shear modulus. Then, shaking table tests are done on a group of single-storey platform systems containing one symmetric platform and three asymmetric platforms with different eccentric forms. Experimental results show that the simulation precision of the restoring force model is rather good for the shear deformation of viscoelastic damper and is also satisfied for the torsion deformation and combined deformations of viscoelastic damper. The shaking table tests have verified that the new-type viscoelastic damper is capable of mitigating the multi-dimensional seismic response of offshore platform.

수열합성중 계면활성제를 이용한 ZnO 나노구조 형상 제어 (Morphology Control of ZnO Nanostructures by Surfactants During Hydrothermal Growth)

  • 박일규
    • 한국분말재료학회지
    • /
    • 제23권4호
    • /
    • pp.270-275
    • /
    • 2016
  • We report on an all-solution-processed hydrothermal method to control the morphology of ZnO nanostructures on Si substrates from three-dimensional hemispherical structures to two-dimensional thin film layers, by controlling the seed layer and the molar contents of surfactants during their primary growth. The size and the density of the seed layer, which is composed of ZnO nanodots, change with variation in the solute concentration. The ZnO nanodots act as heterogeneous nucleation sites for the main ZnO nanostructures. When the seed layer concentration is increased, the ZnO nanostructures change from a hemispherical shape to a thin film structure, formed by densely packed ZnO hemispheres. In addition, the morphology of the ZnO layer is systematically controlled by using trisodium citrate, which acts as a surfactant to enhance the lateral growth of ZnO crystals rather than a preferential one-dimensional growth along the c-direction. X-ray diffraction and energy dispersive X-ray spectroscopy results reveal that the ZnO structure is wurtzite and did not incorporate any impurities from the surfactants used in this study.

수종 인상재의 침지 소독이 경석고 모형의 크기 안정성에 미치는 영향에 관한 연구 (A STUDY ON DIMENSIONAL STABILITY OF IMPRESSION MATERIALS FOLLOWING IMMERSION DISINFECTION)

  • 송기용;양재호;이선형;정헌영
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.506-515
    • /
    • 1999
  • Dental practice can produce and spread some infectious diseases from patients to dentist, dental assistant, and dental labors. One possible method for preventing these cross-contamination is to immerse dental impression in chemical disinfectants. So for many investigators studied on the dimensional changes of dental impressions and on the surface qualities of stone casts made from impression following immersion in disinfectants. This study was proposed to evaluate some popular impression disinfectant combination from the point of dimensional stability. Impression was taken from dental arch-shaped metal model. Irreversible hydrocolloid and 3 elastomers(polyvinyl siloxane, polysulfide, polyether) were immersed in 3 disinfectants (2% glutaraldehyde, 1% povidone-iodine, 0.5% sodium hypochlorite) for 10 minutes and measured both cross-arch and anterior-posterior distance under stereo microscope to evaluate dimensional change. The results obtained were as follows: 1. Dimensional changes of irreversible hydrocolloid impression was statistically different in cross-arch and anterior-posterior distance when immersed in 2% glutaraldehyde solution and in anterior-posterior distance when immersed in 0.5% sodium hypochlorite solution from control group (p<0.05). 2. Dimensional changes of polyvinyl siloxane and polysulfide impression were not statistically different from control group (p>0.05). 3. Dimensional changes of polyether impression was statistically different in cross-arch distance when immersed in 0.5% sodium hypochlorite solution and in anterior-posterior distance when immersed in 1% povidone-iodine solution from control group (p<0.05). 4. In all cases, dimensional changes were less than 0.1% from the original dimension and concluded clinically acceptable.

  • PDF

Flexure hinge mechanism having amplified rectilinear motion for confocal scanning microscopy using optical section

  • Kwon, Oh-Kyu;Park, Poo-Gyeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.162.6-162
    • /
    • 2001
  • Confocal scanning microscopy (CSM) is an important instrument in a wide variety of imaging applications because of its ability to provide three-dimensional images of thick, volume specimens. The mechanism for two-dimensional beam scanning and optical sectioning has an important roe in CSM as the three-dimensional profiler. This optical sectioning property arises from the use of a point detector, which serves to attenuate the signals from out-of-focus. The intensity profile for the open loop scanning should be matched with its response for the standard. The non-linearity can be minimized with the optical sectioning or the optical probe of the closed loop control. This paper shows the mathematical expression of the light such as the extinction curve in the optical fields of system using AO deflector, the axial/lateral response experimentally when the error sources change, and the methods of optical sectioning. Thorough design of optical sectioner is crucial to the success of CSM in the field ...

  • PDF

Effects of the partially movable control fin with end plate of underwater vehicle

  • Jung, Chul-Min;Paik, Bu-Geun;Park, Warn-Gyu
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권1호
    • /
    • pp.55-65
    • /
    • 2017
  • Underwater torpedo has control fin with very low aspect ratio due to launching from limited size of cylindrical torpedo tube. If the aspect ratio of control fin of underwater vehicle is very low three-dimensional flow around control fin largely reduces control forces. In this study, the end plate was applied to reduce the three-dimensional flow effects of partially movable control fin of underwater vehicle. Through numerical simulations the flow field around control fin was examined with and without end plate for different flap angles. The pressure, vorticity, lift and torque on the control fin were analyzed and compared to experiments. The comparison have shown a reasonable agreement between numerical and experimental results and the effect of end plate on a low aspect ratio control fin. When the end plate was attached to the movable control fin, the lift increased and the actuator shaft torque did not significantly change. As this means less consumption of the actuator shaft torque compared to the control fin that has the same control force, the inner actuator capacity can be reduced and energy consumption can be saved. Considering this, it is expected to be effectively applied to the control fin design of underwater vehicles such as torpedoes.

2,3차원배열을 갖는 섬유상 A12O3-(m-ZrO2)/t-ZrO2 복합재료의 제조 (Fabrication of Fibrous A12O3-(m-ZrO2)/t-ZrO2 Composites Having 2, 3-Dimensional Array)

  • 김기현;이병택
    • 한국재료학회지
    • /
    • 제15권9호
    • /
    • pp.608-612
    • /
    • 2005
  • Microstructure and mechanical properties of fibrous $A1_2O_3-(m-ZrO_2)/t-ZrO_2$ composite were investigated depending on the dimensional array. By the change of stacking arrangement of fibrous filaments, 2 and 3-dimensional fibrous composites were successfully obtained without bulk defects such as shrinkage cavity and cracks. The maximum mechanical properties were achieved In the 3-dimensional array composite, due to the fine fibrous and dense microstructure control, in which the values of vickers hardness, fracture toughness and bending strength were about 1507 Hv, $7.2MPa{\cdot}m^{1/2}$ and 650 MPa, respectively.

가상현실 시스템에서의 3차원 입력장치의 인간성능 평가 (Human performance evaluation of the three-dimensional input devices in virtual environment system)

  • 박재희;박경수
    • 대한인간공학회지
    • /
    • 제19권1호
    • /
    • pp.49-61
    • /
    • 2000
  • An experiment was designed to evaluate Fitts' law for the three-dimensional virtual pointing task and to compare the three input devices; Spaceball, Spacemouse, and 3D-Mouse. The result showed that Fitts law fitted poorly for the three-dimensional pointing tasks with relatively low coefficients of determinant. Three reasons, high degree-of-freedom, dynamic egocentric viewpoint change, and clutching problem were discussed to explain the poor fitness of Fitts' law. In terms of device comparison, the 3D-Mouse was superior to the other input devices. Also, the stereoscopic display significantly increased the performance. The results of this study can be used for the design of virtual control tasks and the selection of suitable input devices.

  • PDF

The Rate of Change of an Energy Functional for Axially Moving Continua

  • Yang, Kyung-Jinn;Hong, Keum-Shik;Matsuno, Fumitoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2707-2712
    • /
    • 2003
  • In this paper, with the utilization of a three-dimensional version of Leibniz’s rule, the procedure of deriving the time rate of change of an energy functional for axially moving continua is investigated. It will be shown that the method in [14], which describes the way of getting the time rate of change of an energy functional in Eulerian description, and subsequent results in [10, 11] are not complete. The key point is that the time derivatives at boundaries in the Eulerian description of axially moving continua should take into account the velocity of the moving material itself. A noble way of deriving the time rate of change of the energy functional is proposed. The correctness of the proposed method has been confirmed by other approaches. Two examples, one-dimensional axially moving string and beam equations, are provided for the purpose of demonstration. The results following the procedure proposed and the results in [14] are compared.

  • PDF

Three dimensional analysis of temperature effect on control rod worth in TRR

  • Yari, Maedeh;Lashkari, Ahmad;Masoudi, S. Farhad;Hosseinipanah, Mirshahram
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1266-1276
    • /
    • 2018
  • In this paper, three-dimensional neutronic calculations were performed in order to calculate the dependency of CRW on the temperature of fuel and moderator and the moderator void. Calculations were performed using the known MTR_PC computer codes in the core configuration 61 of TRR. The dependency of CRW on the fuel temperature in the range of $20-340^{\circ}C$ and the moderator temperature of each control rods were studied. Based on the positions of the control rods, the calculations were performed in three different cases, named case A, B and C. By the results, the worth of each control rods increases by increasing of the coolant temperature in all methods, however, the total CRW is somewhat independent of the fuel temperature. In addition, the results showed that the variation of CRW versus density depends on the positions of the control rods and the most change in CRW in the coolant temperature, $20-100^{\circ}C$ (279 pcm), belongs to SR4. Finally the effect of void on CRW was studied for different void fraction in coolant. The most worth change is about $2 for 40% void fraction related to SR1 and SR3 in case B. For 40% void fraction, the total CRW increases about $7.5, $6 and $7 in cases, A, B and C, respectively.