• Title/Summary/Keyword: Dilution of Precision

Search Result 114, Processing Time 0.647 seconds

Design and Implementation of Assisted GPS Navigation Systems Using TPEG Protocol of Terrestrial DMB Data Services (지상파 DMB 데이터 서비스의 TPEG프로토콜을 이용한 Assisted GPS 항법 시스템의 설계 및 구현)

  • Kim, Byung-Soo;Min, Seung-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.11B
    • /
    • pp.1618-1623
    • /
    • 2010
  • In this paper, we propose a new assisted global positioning system (A-GPS) using terrestrial digital multimedia broadcasting (T-DMB) data services. Because of the weak signal strength from GPS satellite and the signal blockage, it is difficult for the telematics terminal to determine the position in urban area. Proposed A-GPS system calculates pseudo range (PR) from timing information of GPS satellites and obtains the satellite information such as ephemeris from T-DMB station to determine the current position. Compared to conventional GPS system, the proposed system has better performance in terms of the fast time to first fix (TTFF), low horizontal dilution of precision (HDOP). Experimental results show that the proposed system is a feasible and robust solution.

Thermal Ion Mass Spectrometry with Isotope Dilution Method: An application to Rare Earth Element Geochemistry (동위원소희석법을 이용한 열이온 질량분석: 희토류원소 지구화학에의 응용)

  • ;;;增田彰正
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.190-201
    • /
    • 2001
  • Isotope Dilution Mass Spectrometry(IDMS) is one of the analytical method which uses enriched isotope spikes and analyzes the abundance of element by comparison of the spectrum between spiked mass and non-spike mass. Especially, the Thermal Ion Mass Spectrometry with isotope dilution technique (in general ID-TIMS) is the most accurate method of the chemical analysis, which enables us to obtain the data better than 1% in accuracy and precision. In IDMS, enriched isotope spike is one of the most important factor in order to obtain the best data. For rare earth elements, in general, a mixture of /sup 138/La, /sup 142/Ce, /sup 145/Nd, /sup 149/Sm, /sup 151/Sm, /sup 151/Eu, /sup 157/Gd, /sup 163/Dy, /sup 167/Er, /sup 171/Yb, and /sup 176/Lu is used as composite spike. IDMS is very useful in geochronology and REE geochemistry. Especially, it is very effective in studying the “tetrad effect” of rare earth elements in natural samples.

  • PDF

Estimation of Measurement Uncertainty in Vitamin C Analysis from Vegetable and Fruit Juice (야채음료 중 비타민 C 분석에 있어서의 측정불확도 추정)

  • Kim, Young-Jun;Kim, Hyeon-Wee
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1053-1059
    • /
    • 2003
  • This study aimed to determine the amount of vitamin C from vegetable & fruit juice by high performance liquid chromatograhy (HPLC). Components for estimation of measurement uncertainty associated with the analysis of vitamin C, such as standard weight, purity, molecular weight, dilution of standard solution, calibration curve, recovery, and precision, were importantly applied. The estimation of uncertainty obtained with systematic and random error based on the GUM (Guide to the expression of uncertainty in measurement) and EURACHEM document with mathematical calculation and statistical analysis. The components, evaluated ty either Type A or Type B methods, were combined to produce an overall value of uncertainty known as the combined standard uncertainty. An expanded uncertainty was obtained by multiplying the combined standard uncertainty with a coverage factor (k) calculated from the effective degree of freedom. The content of vitamin C from vegetable and fruit juice was 27.53 mg/100g and the expanded uncertainty by multiplying by the coverage factor (k, 2.06) was 0.63 mg/100g at a 95% confidence level. It was concluded that the main sources were, in order of recovery and precision, weight and purity of the reference material, dilution of the standard solution, and calibration curve. Careful experiments on other higher uncertainties is further needed in addition to better personal proficiency in sample analysis in terms of accuracy and precision.

A Simulation Study on the Use of GPS Signals to Infer 3-D Atmospheric Wet Refractivity Structure

  • Chiang, Chen-Ching;Liou, Yuei-An
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1021-1023
    • /
    • 2003
  • Atmospheric water vapor is a key variable in numerical weather prediction (NWP) models, but it is a crucial factor to limit the accuracy of high-precision GPS positioning technique. For both issues, knowledge about the amount of water vapor is extremely important. In this study, we perform a simulation study to utilize GPS signals through a developed tomographic scheme to retrieve 3D structure of atmospheric wet refractivity, which may be assimilated into NWP models for advancing forecasting or position calculation for improving GPS positioning accuracy. For the purpose of knowing the absolute accuracy of the developed tomographic method, a well-defined temporal and spatial varying state of atmospheric profile is utilized. Under such circumstance, several factors that may influence the retrievals can be easily examined and their impacts may be clearly quantified. They include the values of the positional dilution of precision (PDOP) factors of the GPS signals, ... etc. Based upon the use of a variety spectrum of adjustable factors, many interesting findings are obtained. For example, the more is the number of the observed GPS signals the better becomes the retrievals as expected. Also, the smaller is the PDOP value the better becomes the retrievals.

  • PDF

A study on improvement of positioning accuracy using DGPS technique with low cost GPS modules (저가의 GPS 모듈에 DGPS 기술을 이용한 위치측정정확도 개선에 관한 연구)

  • 이창복;안준석;주세철;김기두
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.12 no.2
    • /
    • pp.155-161
    • /
    • 1994
  • Accurate positioning method using low cost GPS modules is proposed, which use the technique of differential GPS. DGPS experiments have been made using two coarse-acquisition (C/A) code GPS modules. Position accuracy of better than 5 m was obtained for position dilution of precision (PDOP) of 2-3 and that of better than 10 m after filtering was obtained for PDOP of about 9 in a local area. Static DGPS experiments were performed at Kookmin university with the DGPS correction data of KRISS reference station at Taejon. The distance between two stations is about 140 km. The results show that precision of the position is about 10 m (2 drms), which is ten times better than the results with the GPS module alone. Accuracy of about 10 meters can be obtained in near real time by the DGPS service with a reference station in our country.

  • PDF

Real-Time Orbit Determination for Future Korean Regional Navigation Satellite System

  • Shin, Kihae;Oh, Hyungjik;Park, Sang-Young;Park, Chandeok
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • This paper presents an algorithm for Real-Time Orbit Determination (RTOD) of navigation satellites for the Korean Regional Navigation Satellite System (KRNSS), when the navigation satellites generate ephemeris by themselves in abnormal situations. The KRNSS is an independent Regional Navigation Satellite System (RNSS) that is currently within the basic/preliminary research phase, which is intended to provide a satellite navigation service for South Korea and neighboring countries. Its candidate constellation comprises three geostationary and four elliptical inclined geosynchronous orbit satellites. Relative distance ranging between the KRNSS satellites based on Inter-Satellite Ranging (ISR) is adopted as the observation model. The extended Kalman filter is used for real-time estimation, which includes fine-tuning the covariance, measurement noise, and process noise matrices. Simulation results show that ISR precision of 0.3-0.7 m, ranging capability of 65,000 km, and observation intervals of less than 20 min are required to accomplish RTOD accuracy to within 1 m. Furthermore, close correlation is confirmed between the dilution of precision and RTOD accuracy.

The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF

Error Analysis of 3-Dimensional GPS Attitude Determination System

  • Park Chan-Sik;Cho Deuk-Jae;Cha Eun-Jong;Hwang Dong-Hwan;Lee Sang-Jeong
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.4
    • /
    • pp.480-485
    • /
    • 2006
  • In this paper, the error investigation of a 3-dimensional GPS attitude determination system using the error covariance analysis is given. New efficient formulas for computing the Euler Angle Dilution of Precision (EADOP) are also derived. The formulas are easy to compute and represent the attitude error as a function of the nominal attitude of a vehicle, the baseline configuration and the receiver noise. Using the formula, the accuracy of the Euler angle can be analytically predicted without the use of computer simulations. Applications to some configurations reveal the effectiveness of the proposed method.

Two-Dimensional Navigation Error for Geometry of Landmark in Line-Of-Sight Measurement Based Vision Navigation System (시선각 측정기반 비전항법시스템에서 랜드마크의 기하학적 배치에 대한 2차원 항법오차)

  • Kim, Young-Sun;Ji, Hyun-Min;Hwang, Dong-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.479-484
    • /
    • 2012
  • Geometric effect of landmarks to the navigation error is investigated in the two-dimensional line-of-sight measurement based vision navigation system. DOP is derived between line-of-sight measurement error and navigation solution error. For cases of three landmarks in an area, variations of the DOP were observed through computer simulations. Vision navigation system experiments were performed for the cases. Simulation and experimental results show that navigation solution errors have similar trend to DOP values of the simulation.

Partial molal volumes of tetraalkylammonium chlorides in isopropanol-water mixtures (2-프로판올-물 혼합용매에서의 Tetraalkylammonium Chlorides의 분몰랄 부피)

  • Byung-Rin Cho
    • Journal of the Korean Chemical Society
    • /
    • v.15 no.2
    • /
    • pp.95-105
    • /
    • 1971
  • The apparent molal volumes ${\phi}_v$ of a series of homologous tetraalkylammonium chlorides, $Me_4NCl, Et_4NCl, Pr_4NCl,\;and\;Bu_4NCl$, in a series of isopropanol-water mixtures have been determined at $30^{\circ}C$ from precision density measurements using pycnometers. The values of ${\phi}_v$ extrapolated to infinite dilution give partial molal volumes $\={V}^{\circ}$s which are almost additive for successive homologues and enable one to determine the absolute individual ionic partial molal volumes. The experimental results are discussed in terrns of the varying size and surface charge of the ions and the structure of the binary solvent mixtures. The results indicate that at 0.1 mole fraction isopropanol the maximum structuredness of water causes a minimum in the tetraalkylammonium-cation partial molal volumes, while at 0.2 mole fraction the solvent structure is such that the free volumes is a minimum and the electrostrictive effect of chloride ion is a maximum.

  • PDF