• Title/Summary/Keyword: Digital calibration

Search Result 379, Processing Time 0.026 seconds

Using SWAT Model for streamflow simulation in Burundi

  • Habimana, Jean de Dieu;Ha, Doan Thi Thu;Bae, Deg-Hyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.117-117
    • /
    • 2020
  • The main objective of this study was to setup model and evaluate the model performance for streamflow simulation in Burundi using Soil and Water Assessment Tool (SWAT) model. The total area of Burundi is 27,834 ㎢. The elevation of Burundi ranges from 780 m to 2,700m. The West and East are low lands, while the Central part is high land. The topographic data (30 meters Digital Elevation Model) and land use and land cover data of Burundi were obtained respectively from Shuttle Radar Topography Mission (SRTM) and the Regional Centre for Mapping of Resources for Development (RCMRD). The soil data used was obtained from Food and Agriculture Organization (FAO). The local weather data and discharge data were provided by Burundi Hydro meteorological Service (IGEBU). Mean Areal Precipitation (MAP) and Mean Areal Temperature (MAT) were estimated. The streamflow simulation was done for the period 1980-2017. The calibration and validation of river discharge was performed at a daily time step from 2005 through 2011 as the calibration period and 2012 up to 2017 as the validation period. The findings show that streamflow decreases during Jun to September and increases during March to May and October to December.

  • PDF

Accuracy of Close-Range Industrial Photogrammetry Using CCTV Type CCD Camera (CCTV유형 CCD 카메라를 이용한 근거리 산업사진측량의 정확도)

  • 이진덕;최용진
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.19 no.3
    • /
    • pp.283-290
    • /
    • 2001
  • This paper demonstrates the performance of industrial precise measurement using the digital close-range photograrmmetric system based on a off-the-shelf CCTV-type CCD camera. The system was constructed with a CCD camera and a PC with a frame grabber, coupled with digital image mensuration and self-calibrating bundle adjustment techniques. An artificial fish reef with cubic shape was taken as an object for the application test of the system and the digital images were acquired on multi-station convergent network around the object. The geometric calibration of the CCD camera and the phototriangulation of the entire surface of the object was carried out simultaneously by means of self-calibrating bundle adjustment technique. Also the system comprising a high resolution still-video camera Kodak DCS, which high accuracy potential has been already established, were employed in similar network condition. Then the results from two different camera systems were compared in the accuracies of phototriangulation.

  • PDF

System Strategies for Time-Domain Emission Measurements above 1 GHz

  • Hoffmann, Christian;Slim, Hassan Hani;Russer, Peter
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.4
    • /
    • pp.304-310
    • /
    • 2011
  • The application of time-domain methods in emission measurement instruments allows for a reduction in scan time by several orders of magnitude and for new evaluation methods to be realized such as the real-time spectrogram to characterize transient emissions. In this paper two novel systems for time-domain EMI measurements above 1 GHz are presented. The first system combines ultra-fast analog-to-digital-conversion and real-time digital signal processing on a field-programmable-gate-array (FPGA) with ultra-broadband multi-stage down-conversion to enable measurements in the range from 10 Hz to 26 GHz with high sensitivity and full-compliance with the requirements of CISPR 16-1-1. The required IF bandwidths were added to allow for measurements according to MIL-461F and DO-160F. The second system realizes a system of time-interleaved analog-to-digital converters (ADCs) and has an upper bandwidth limit of 4 GHz. With the implementation of an automatic mismatch calibration, the system fulfills CISPR 16-1-1 dynamic range requirements. Measurements of the radiated emissions of electronic consumer devices and household appliances like the non-stationary emissions of a microwave oven are presented. A measurement of a personal computer's conducted emissions on a power supply line according to DO-160F is given.

Validation Experiments for the Determination of Particle Focal Positions in Digital Particle Holography (디지털 입자 홀로그래피의 입자 초점면 결정에 관한 실험적 검증)

  • Yang, Yan;Kang, Bo-Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.10
    • /
    • pp.784-790
    • /
    • 2008
  • The feasibility and the accuracy of the correlation coefficient(CC) method for the determination of particle positions along the optical axis in digital particle holography were verified by alidation experiments. A traverse system with capable of high precision was used to move the particle objects by exact known distances between several different positions. The particle positions along the optical axis were calculated by the CC method and compared with their exact values to obtain the errors of the focal plane determination. The tested particles were 2D dots in a calibration target along with different sized glass beads and droplets that reflected and caused a three-dimensional effect. The results show that the CC method can work well for both the 2D dots and the 3D particles. The effect of other particles on the focal plane determination was also investigated. The CC method can locate the focal plane of particles with a high precision, regardless of the existence of other particles.

Evaluation of SWAT Model Applicability for Runoff Estimation in Nam River Dam Watershed (남강댐 상류 소유역의 유출량 추정을 위한 SWAT 모형의 적용성 평가)

  • Kim, Dong-Hyeon;Kim, Sang-Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.4
    • /
    • pp.9-19
    • /
    • 2016
  • The objective of this study was to evaluate the applicability of SWAT (Soil and Water Assessment Tool) model for runoff estimation in the Nam river dam watershed. Input data for the SWAT model were established using spatial data (land use, soil, digital elevation map) and weather data. The SWAT model was calibrated and validated using observed runoff data from 2003 to 2014 for three stations (Sancheong, Shinan, Changchon) within the study watershed. The $R^2$ (Determination Coefficient), RMSE (Root Mean Square Error), NSE (Nash-Sutcliffe efficiency coefficient), and RMAE (Relative Mean Absolute Error) were used to evaluate the model performance. Parameters for runoff calibration were selected based on user's manual and references and trial and error method was applied for parameter calibration. Calibration results showed that annual mean runoff were within ${\pm}5%$ error compared to observed. $R^2$ were ranged 0.64 ~ 0.75, RMSE were 2.51 ~ 4.97 mm/day, NSE were 0.48 ~ 0.65, and RMAE were 0.34 ~ 0.63 mm/day for daily runoff, respectively. The runoff comparison for three stations showed that annual runoff was higher in Changchon especially summer and winter seasons. The flow exceedance graph showed that Sancheong and Shinan stations were similar while Changchon was higher in entire fraction.

A Study on the Transducer Calibration for Acoustic Emission Measurement (AE 측정을 위한 탐촉자의 보정에 대한 고찰)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.6 no.2
    • /
    • pp.53-58
    • /
    • 1996
  • In order to investigate the source mechanism of micro cracks through acoustic emission measurement induced by rock fracture, careful calibration of the entire linkage of the detecting system, from the transducers to transient recorder, is an essential requirement prior to testing. Transducers and digitiging system are generally the weakest links in the measurement system because they must translate mechanical motions into digital electric signals. In this study, PAC piezoelectric pressure transducers are calibrated with a standard NBS conical shaped displacement transducer and a DG piezoelectric displacement transducer. The NBS and PAC transducers are insensitive to changes in horizontal impingement angle but sensitive to changes in incident angle. The ray path along the logitudinal axis of the tranducer produced a maximum response while the ray path perpendicular to the transducer axis gave a minimum. And a difference in individual transducers factor for a peak-to-peak amplitude of PAC transducers was within 40%. An average PAC transducer coefficient was determined as 77mv/pm by an absolute calibration test using NBS transducer.

  • PDF

Modeling and Experimental Verification on Static Landing Accuracy of Droplets from Magnetostrictive Inkjet Head (자기변형잉크젯헤드에서 토출된 액적의 정적 착지정확도 모델링 및 실험적 검증)

  • Yoo, Eun Ju;Park, Young Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.1
    • /
    • pp.77-84
    • /
    • 2013
  • Most research on the inkjet printing technology has focused on the development of inkjet head itself, and of process, not on the landing accuracy of the droplets to a target. Thus, this paper presents the modeling and experimental verification on the static landing accuracy and precision of the droplets from the magnetostrictive inkjet head. A simple model based on the angle deviation of a nozzle tip and on a distance to a substrate is considered, assuming that there is no ambient effect. The angle deviation of the nozzle tip is determined by using its digital image with the aid of a pixel calculation program, and the distance to the substrate is set to 1 mm. Three experiments have planned and preformed. The first experiment is to collect the initial data for the landing distribution of the droplets. The second experiment is to collect the repeatability data of the stage used. Then, these data are used to rederive the equation for the final landing position of the droplet. The final experiment is to verify the equation and to show the calibration results. The respective landing accuracy of the droplet after calibration on the x-axis and on y axis has improved from $338.51{\mu}m$ and $-133.63{\mu}m$ to $7.06{\mu}m$ and $13.11{\mu}m$. The respective percent improvement on the x-axis and on y axis reaches about 98 and about 90. The respective landing precision of the droplet after calibration on the x-axis and on y axis has improved from ${\pm}182.6{\mu}m$ and ${\pm}182.88{\mu}m$ to ${\pm}24.64{\mu}m$ and ${\pm}42.76{\mu}m$. The respective percent improvement on the x-axis and on y axis reaches about 87 and about 77.

Design of Fractional-N Digital PLL for IoT Application (IoT 어플리케이션을 위한 분수분주형 디지털 위상고정루프 설계)

  • Kim, Shinwoong
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.800-804
    • /
    • 2019
  • This paper presents a dual-loop sub-sampling digital PLL for a 2.4 GHz IoT applications. The PLL initially performs a divider-based coarse lock and switches to a divider-less fine sub-sampling lock. It achieves a low in-band phase noise performance by enabling the use of a high resolution time-to-digital converter (TDC) and a digital-to-time converter (DTC) in a selected timing range. To remove the difference between the phase offsets of the coarse and fine loops, a phase offset calibration scheme is proposed. The phase offset of the fine loop is estimated during the coarse lock and reflected in the coarse lock process, resulting in a smooth transition to the fine lock with a stable fast settling. The proposed digital PLL is designed by SystemVerilog modeling and Verilog-HDL and fully verified with simulations.

Design of Phase Locked Loop (PLL) based Time to Digital Converter for LiDAR System with Measurement of Absolute Time Difference (LiDAR 시스템용 절대시간 측정을 위한 위상고정루프 기반 시간 디지털 변환기 설계)

  • Yoo, Sang-Sun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.5
    • /
    • pp.677-684
    • /
    • 2021
  • This paper presents a time-to-digital converter for measuring absolute time differences. The time-to-digital converter was designed and fabricated in 0.18-um CMOS technology and it can be applied to Light Detection and Ranging system which requires long time-cover range and 50ps time resolution. Since designed time-to-digital converter adopted the reference clock of 625MHz generated by phase locked loop, it could have absolute time resolution of 50ps after automatic calibration and its cover range was over than 800ns. The time-to-digital converter adopted a counter and chain delay lines for time measurement. The counter is used for coarse time measurement and chain delay lines are used for fine time measurement. From many times experiments, fabricated time-to-digital converter has 50 ps time resolution with maximum INL of 0.8 LSB and its power consumption is about 70 mW.

Design of a High-Resolution Integrating Sigma-Delta ADC for Battery Capacity Measurement (배터리 용량측정을 위한 고해상도 Integrating Sigma-Delta ADC 설계)

  • Park, Chul-Kyu;Jang, Ki-Chang;Woo, Sun-Sik;Choi, Joong-Ho
    • Journal of IKEEE
    • /
    • v.16 no.1
    • /
    • pp.28-33
    • /
    • 2012
  • Recently, with mobile devices increasing, as a variety of multimedia functions are needed, battery life is decreased. Accordingly the methods for extending the battery life has been proposed. In order to implement these methods, we have to know exactly the status of the battery, so we need a high resolution analog to digital converter(ADC). In case of the existing integrating sigma-delta ADC, it have not convert reset-time conversion cycle to function of resolution. Because of this reason, all digital values corresponding to the all number of bits will not be able to be expressed. To compensated this drawback, this paper propose that all digital values corresponding to the number of bits can be expressed without having to convert reset-time additional conversion cycle to function of resolution by using a up-down counter. The proposed circuit achieves improved SNDR compared to conventional converters simulation result. Also, this was designed for low power suitable for battery management systems and fabricated in 0.35um process.