• Title/Summary/Keyword: Digital Calibration

검색결과 379건 처리시간 0.028초

철도 선형 복원을 위한 지상사진측량의 적용 (Application of the Terrestrial Photogrammetric for Railway Alignments Reconstruction)

  • 이종출;박운용;강인준;장호식
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2006년도 춘계학술발표회 논문집
    • /
    • pp.265-269
    • /
    • 2006
  • In this study, horizontal alignment of railroad obtained by digital photogrammetry method. The two-dimensional horizontal alignment was reappeared by camera calibration and digital image data. This method's result showed more satisfactory value than existing survey method in horizontal alignment of railroad. Hereafter, this method would be a appropriate method lot the decision of railroad facility' position in small rural area and construction of DB for the design of alignment.

  • PDF

계측기기 자동 교정프로그램 개발 (Development of Auto Calibration Program on Instruments)

  • 조현섭;오명관
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2009년도 추계학술발표논문집
    • /
    • pp.636-639
    • /
    • 2009
  • In spite of the presence of various kind of Integrated Circuits it's not always easy to get the right part. Besides, it is hard to find a vendor for a small quantity consumers like who develop prototype applications. In this study, we've tried to get the logical signals from the PC based device we've developed that correspondents with the real ICs. It can emulate decoder ICs, multiplexers, demultiplexers and basic logic gates.

  • PDF

Three Dimensional Shape Measurement of a Micro Fresnel Lens with In-line Phase-shifting Digital Holographic Microscopy

  • Kang, Jeon-Woong;Hong, Chung-Ki
    • Journal of the Optical Society of Korea
    • /
    • 제10권4호
    • /
    • pp.178-183
    • /
    • 2006
  • An in-line phase-shifting digital holographic microscopy system was constructed by inserting a conventional microscope in the object arm of a Mach-Zehnder interferometer. It was used to measure the three dimensional shape of a micro Fresnel lens. It was also shown that both the lateral and the axial resolutions of the in-line phase-shifting system using a self-calibration algorithm were superior to those of the best off-axis system.

Stereo Vision과 디지털 화상상관법을 이용한 파괴시험편의 측면 함몰의 현장 측정 (In situ Measurement of Lateral Side-Necking of a Fracture Specimen Using a Stereo Vision and Digital Image Correlation)

  • 이정현;강기주
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.154-161
    • /
    • 2004
  • An experimental method for measuring side-necking deformation near a crack-tip is described. It is based on Stereoscopic Digital Speckle Photography and Digital Image Correlation, and it is simple and robust to mechanical vibration inherent to a hydraulic material test system. The validity and accuracy are evaluated through a calibration fur rigid body translation. A case study has been performed for a CT specimen made of a ductile steel and the three dimensional profiles of the side-necked region are presented as the load increases. Also, the details of the procedure and the surface treatment are discussed.

Functional Integration of Serial Dilution and Capillary Electrophoresis on a PDMS Microchip

  • Chang, Jun-Keun;Heo, Yun-Seok;Hyunwoo Bang;Keunchang Cho;Seok Chung;Chanil Chung;Han, Dong-Chul
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제8권4호
    • /
    • pp.233-239
    • /
    • 2003
  • For the quantitative analysis of an unknown sample a calibration curve should be obtained, as analytical instruments give relative, rather than absolute measurements. Therefore, researchers should make standard samples with various known concentrations, measure each standard and the unknown sample, and then determine the concentration of the unknown by comparing the measured value to those of the standards. These procedures are tedious and time-consuming. Therefore, we developed a polymer based microfluidic device from polydimethylsiloxane, which integrates serial dilution and capillary electrophoresis functions in a single device. The integrated microchip can provide a one-step analytical tool, and thus replace the complex experimental procedures. Two plastic syringes, one containing a buffer solution and the other a standard solution, were connected to two inlet holes on a microchip, and pushed by a hydrodynamic force. The standard sample is serially diluted to various concentrations through the microfluidic networks. The diluted samples are sequentially introduced through microchannels by electro-osmotic force, and their laser-induced fluorescence signals measured by capillary electrophoresis. We demonstrate the integrated microchip performance by measuring the fluorescence signals of fluorescein at various concentrations. The calibration curve obtained from the electropherograms showed the expected linearity.

저잡음화 계측회로에 의한 다음극형 용존산소센서의 산소투과특성 (Oxygen Permeability Characteristics of the Multi-Cathode Type Dissolved Oxygen Sensor Using the Low Noise Measuring Circuit)

  • 이동희;김태진;김영환;성영권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.764-766
    • /
    • 1998
  • An evaluation method for oxygen permeable characteristics of the membrane covering to each cathode of multiple cathode - single anode type dissolved oxygen sensor, which has high reproducibility and is capable of measuring multiple components in solutions. For this purpose, a measuring circuit for the multiple cathode type DO sensor was designed to lower the noise signal by adapting a digital LPF to readout the sensor output accurately. Digital LPF is designed by setting up the transfer function to set the cutoff frequency to 10Hz, and the transfer function is programmed by C language, and then the filtering characteristics are evaluated with the simulation and experiments. Using this LPF added measuring circuit for the multiple cathode type DO sensor, we have obtained the calibration factor for each cathode to calibrate the variation of the output signals. The calibration factor was obtained by measuring the sensor output signal followed by oxygen partial pressure, using the same oxygen permeable membrane at each cathode of the multiple cathode type DO sensor.

  • PDF

u-Health 서비스를 위한 스마트폰용 스펙트럼 측정 시스템 개발 (Development of Smart Phone Application With Spectrometer for u-Health Service)

  • 김동수;이서준;이태로
    • 디지털융복합연구
    • /
    • 제11권7호
    • /
    • pp.261-269
    • /
    • 2013
  • u-Health는 최근 기술이며 의료 진단과 건강관리를 위한 새로운 방법론이다. 그러나 이를 실현하려면 몇 가지 기술적 장벽들(이동성, 소형화, 배터리 수명 문제 등)을 넘어서야 한다. 본 논문에서는 u-Health 서비스에 적합한 스마트폰용 스펙트럼 측정 시스템을 개발하였다. 실험 결과 기존 솔루션에 비해 무선이면서 크기가 매우 작지만 성능 면(재현성 비교실험에서 Spectrum, Calibration Curve, Prediction)에서 거의 일치한다는 것을 확인하였다. 따라서 개발된 솔루션은 u-Health 분야에서 널리 활용되어질 것으로 기대된다.

스테레오 카메라와 비균일 메시를 이용한 체적 계산 알고리즘 (Volume Calculation Using Stereo Camera and Non-uniform Mesh)

  • 이영대;조성윤
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2012년도 제46차 하계학술발표논문집 20권2호
    • /
    • pp.429-432
    • /
    • 2012
  • 이 논문에서는 쓰레기 매립의 표준화를 위한 일환으로 쓰레기 체적을 주기적으로 계산하는 알고리즘을 제시하였다. 안전하고 쾌적한 도시 환경을 조성하기 위해 폐기물 매립 시설은 필요하며 폐기물 부피 관리의 신뢰성 및 용량 정보의 정확성을 파악하는 것이 필요하다. 카메라 캘리브레이션 이후에 대상체의 표면에 대한 포인트 클라우드(point cloud)를 얻을 수 있었으며 이것을 물체의 체적 계산 알고리즘의 입력으로 선택하였다. 비균일 격자(uniformmeshing) 방법에 기초한 체적 계산 알고리즘을 제안하였으며 알고리즘의 타당성을 시뮬레이션과 실제 실험을 통해 입증하였다. 제시된 알고리즘은 쓰레기 매립의 체적 계산 뿐 만이 아니라 삼차원 객체의 일반적인 체적 계산을 위한 알고리즘으로도 사용될 수 있다.

  • PDF

만경강유역에서의 HSPF 모형의 보정 (Calibration of HSPF Model from Mangyeong River Watershed)

  • 정재운;장정렬;정지연;최강원;임병진;김상돈;김갑순;윤광식
    • 한국관개배수논문집
    • /
    • 제18권1호
    • /
    • pp.58-67
    • /
    • 2011
  • The HSPF (Hydrological Simulation Program-Fortran) model was applied to Mangyeong river watershed to examine its applicability through calibration using monitoring data. For the model application, digital maps were constructed for watershed boundary, land-use, Digital Elevation Model of Mangyeong river watershed using BASINS (Better Assessment Science for Intergrating point and Nonpoint Sources) program. The observed runoff was 1976.4mm while the simulated runoff was 1913.4mm from 2007 to 2008. The model results showed that the simulated runoff was in a good agreement with the observed data and indicated reasonable applicability of the model. In terms of water quality, trends of the observed value were in a good agreement with simulated value despite its model performance lower than expected. However, its reliability and performance were with the expectation considering complexity of the watershed, pollutant sources and land use intermixed in the watershed. Overall, we identified application of HSPF model as reliable evidence by model performance.

  • PDF

복사전달모델을 이용한 KOMPSAT-3A 중적외선 데이터의 복사보정계수 산출: 탐구적 사례 (Derivation of Radiometric Calibration Coefficients for KOMPSAT-3A Mid-wave Infrared Data Using a Radiative Transfer Model: An Exploratory Example)

  • 김용승
    • 대한원격탐사학회지
    • /
    • 제36권6_2호
    • /
    • pp.1629-1634
    • /
    • 2020
  • 위성데이터 처리과정에서 지표온도와 같은 지구물리변수를 산출하려면 위성에서 관측한 수치 값(Digital Number, DN)을 물리적 변수인 복사량(Radiance)으로 변환시키는 과정이 필수적이다. 본 연구의 목적은 위성발사 전에 실험실 측정치로 수립된 DN·Radiance 관계식을 KOMPSAT-3A 중적외선 데이터와 MODTRAN 복사전달모델을 이용하여 개선하는데 있다. 연구결과는 개선된 DN Radiance 관계식이 현실적인 복사량 값을 제공할 수 있음을 보였다. 후속연구에서는 이들 복사량에 대해 지상관측과 복사전달모델을 이용해 보다 정량적인 검증이 이루어지기를 기대한다.