• Title/Summary/Keyword: Diaphragm frequency

Search Result 89, Processing Time 0.024 seconds

Analysis of Total Harmonic Distortion in Microspeaker Considering Coupling Effect (연성 효과를 고려한 마이크로스피커 왜율분석)

  • Kwon, Joong-Hak;Kim, Kwang-Suk;Bang, Ki-Chang;Hwang, Sang-Moon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.4
    • /
    • pp.473-479
    • /
    • 2008
  • With the advent of mobile phone, digital multimedia broadcasting(DMB) service is to be realized for multimedia data communication. For an acoustic part, a smaller and lighter microspeaker is also soon to be realized as an MP3 song player and a speakerphone. Sound quality in the microspeaker is becoming more important in mobile phones. It is evaluated by total harmonic distortion(THD). THD is the proportion of higher order frequencies output response to sinusoidal input signal. It is affected by uneven magnetic distribution and nonlinear response of diaphragm. In this paper, harmonic distortion is analyzed by considering magnetic and mechanical coupling effects. Simulated results of THD are compared with experimental data. Results show that THD in lower frequency range is higher due to high displace on voice coil and high mechanical response of high order frequency.

Analysis of total harmonic distortion in microspeaker considering coupling effect (연성 효과를 고려한 마이크로스피커 왜율분석)

  • Kwon, Joong-Hak;Kim, Kwang-Suk;Bang, Ki-Chang;Hwang, Sang-Moon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.236-241
    • /
    • 2008
  • With the advent of mobile phone, Digital multimedia broadcasting (DMB) service is to be realized for multimedia data communication. For an acoustic part, a smaller and lighter microspeaker is also soon to be realized as an MP3 song player and a speakerphone. Sound quality in the microspeaker is becoming more important in mobile phones. It is evaluated by total harmonic distortion (THD). THD is the proportion of higher order frequencies output response to sinusoidal input signal. It is affected by uneven magnetic distribution and nonlinear response of diaphragm. In this paper, harmonic distortion is analyzed by considering magnetic and mechanical coupling effects. Simulated results of THD are compared with experimental data. Results show that THD in lower frequency range is higher due to high displace on voice coil and high mechanical response of high order frequency.

  • PDF

A Design and manufacture of acoustic-optic converter in the Uniform FBG hydrophone sensor. (균일한 FBG(Fiber Bragg Grating) Hydrophone의 음향-광변환기 설계 및 제작)

  • Kim, Kyung-Bok;Kwack, Kae-Dal
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.281-287
    • /
    • 2000
  • For the improvement of frequency characteristics of FBG(Fiber Bragg Grating) hydrophone sensor, we can detected the frequency ranging to 1.4KHz and acoustic directivity by the development of newly designed diaphragm and united type of FBG.

  • PDF

A Study on the Small Size Loudspeaker for Hi-Fi Low Frequency Sound Reproduction (저음재생용 소형 스피커의 개발에 관한 연구)

  • 남경준;이채봉;김천덕
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.8
    • /
    • pp.31-37
    • /
    • 2001
  • Following the recent trends of reducing the size of multimedia devices, we tried for the development of a compact-sized speaker to produce low-frequency sounds efficiently. For this work, equivalent-circuit analysis was used to get fundamental resonant frequency and then the structure of speaker components has been changed appropriately. As a result, an 80mm small-sized speaker was developed. The performance test showed that the resonant frequency of our system is 79 Hz while that of numerical analysis was 81Hz. At a distance of 1m from our speaker, the frequency ranges 80 Hz to 15kHz and the average sound pressure was found to be 84±2 dB. The second (at 400 Hz) and the third (at 100 Hz) high-frequency distortions of our system were 0.5% and 1.8% respectively, which is to be compared with the distortions of 0.9% and 6% in conventional speakers.

  • PDF

The Influences of Residual Stress on the Frequency of Ultrasonic Transducers with Composite Membrane Structure

  • Lee Seungmock;Kim Jong-Min;Shin Young-Eui
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.76-84
    • /
    • 2006
  • Arrayed ultrasonic sensors based on the piezoelectric thin film (lead-zirconate-titanate: Pb($Zr_{0.52}Ti_{0.48})O_{3}$) having composite membrane structure are fabricated. Different thermal and elastic characteristics of each layer generate the residual stress during the high temperature deposition processes, accomplished diaphragm is consequently bowing. We present the membrane deflection effects originated from the residual stress on the resonant frequencies of the sensor chips. The resonant frequencies ($f_r$) measured of each sensor structures are located in the range of $87.6{\sim}111\;kHz$, these are larger $30{\sim}40\;kHz$ than the resultant frequencies of FEM. The primary factors of $f_r$ deviations from the ideal FEM results are the membrane deflections, and the influence of stiffness variations are not so large on that. Membrane deflections have the effect of total thickness increase which sensitively change the $f_r$ to the positive direction. Stress generations of the membrane are also numerically predicted for considering the effect of stiffness variations on the $f_r$.

The Frequency Effect in the Somatosensory Cortex Response to Vibrotactile Stimulator in fMRI (기능적 자기공명영상에서 진동자의 자극 주파수가 감각피질의 반응에 미치는 영향)

  • Lee Hyunsook
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.128-133
    • /
    • 2004
  • The fMRI response of the somatosensory cortex was investigated with vibrotactile stimulation. Three different frequencies of 8, 15, or 25 Hz were applied in order to mainly focus on the hemodynamic response of Meissner corpuscles sensitive to frequencies of 5-40 Hz. A closed-system, pneumatically-driven, rubber diaphragm was fabricated that overcame many of the limitations of existing vibrotactile devices and produced robust sensory cortex activation in an fMRI experiment. Increasing frequency vs. activation area was analyzed in terms of signal percent change and number of pixels. Our preliminary results indicated that the distribution of the signal percentage change widened and more activated pixels were obtained with higher frequencies.

  • PDF

High Performance Piezoelectric Microspeakers and Thin Speaker Array System

  • Kim, Hye-Jin;Koo, Kun-Mo;Lee, Sung-Q;Park, Kang-Ho;Kim, Jong-Dae
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.680-687
    • /
    • 2009
  • This paper reports on an improved piezoelectric microspeaker with a high sound pressure level of 90 dB, a total harmonic distortion of less than 15%, and coherence higher than 0.9. The fabricated Pb(Zr,Ti)$O_3$ (PZT) microspeakers have a thickness of only 1 mm including the speaker frame and an active area of 18 mm${\times}$20 mm. To achieve higher sound pressure and lower distortion, the PZT piezoelectric microspeaker has a well-designed speaker frame and a piezoelectric diaphragm consisting of a tilted PZT membrane and silicone buffer layer. From the simulation and measurement results, we confirmed that the silicon buffer layer can lower the first resonant frequency, which enhances the microspeaker's sound pressure at a low frequency range and can also reduce useless distortion generated by the harmonics. The fabricated PZT piezoelectric microspeakers are implemented on a multichannel speaker array system for personal acoustical space generation. The output sound pressure at a 30 cm distance away from the center of the speaker line array is 15 dB higher than the sound pressure at the neighboring region 30 degrees from the vertical axis.

Implementation of a Waveguide Cross Guide directional Coupler for Ku-Band using Polynomial Approximations for the Polarizabilities of the Rounded End Slot (끝이 둥근 슬롯의 분극률에 대한 다항 근사식을 이용한 Ku-Band용 도파관 십자형 방향성 결합기 제작)

  • 유경완;이재현;박광량;김재명
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.8
    • /
    • pp.7-15
    • /
    • 1994
  • In this paper, the directional coupler for Ku-band, which is designed is of the crossguide type with a coupling value of about 3-dB. The apertures chosen for this design are crosses. We used polynomial approximations of rounded end slot to obtain the electric and magnetic polarizability of crossed-slot and compared the results with Cohn's experimental results. The optimized dimensions and positions of the cross aperture are obtained by a trial-and-error reiteration of the program. This paper presents the measurement results for the designed coupler. The very flat coupling shows a total variation of only 29.80$\pm$0.04dB for the design frequency ranges of 12.25GHz-12.75GHz. The measured minimum directivity is 25dB. The aperture attenuation for the finite diaphragm thickness is about 2dB pr 0.5mm, which is in agreement with the theoretical value. The transmission loss and input return loss at center frequency are 0.0564dB and 48.16dB respectively. We obtained the measured minimum directivity of the coupler. Whose apertures are both circles is better than that containing holes in the performance of directivity.

  • PDF

Fabrication of Microactuators Using Conductive Polymer (전도성 고분자를 이용한 마이크로 액추에이터 제작)

  • Lee, Seung-Ki;ChoI, Young;An, Ho-Jung;Park, Jung-Ho;Sim, Woo-Young;Yang, Sang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.12
    • /
    • pp.698-704
    • /
    • 2000
  • Mechanical performances of beam shaped and bridge-shaped conductive polymer actuator have been measured and analyzed varying polymerization conditions and operating conditions such as applied current, polymerizing time, frequency of the current and kinds of electrolytes. For the application of conductive polymer actuator to micropump, the diaphragm structure has been fabricated, which is composed of polypyrrole, solid polymer electrolyte and parylene. Measured results how the possibility of the practical application of conductive polymer actuator.

  • PDF

Primary Rib Chondrosarcoma in a Dog (원발성 개 늑연골육종 1예)

  • 권오경;이충호;최재훈;최지혜;김대용;윤정희;최민철;윤화영;남치주
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.261-265
    • /
    • 2000
  • Primary rib tumors occur in dogs at a much lower frequency than appendicular bone neoplasms. A 3-year-old 3.5kg female maltese was referred to the Veterinary Medical Teaching Hospital because of a 2-month history of severe coughing and a 1-month history of dyspnea, gaging, and anorexia. The plain thoracic radiography revealed a huge well-defined mass in the left thoracic cavity, and a diagnosis of primary rib chondrosarcoma was established by histopathologic evaluation of the surgical biopsy specimen. At operation, a 8-x12-x4.5-cm relatively large firm mass was found filling the lumen of the thoracic, which was diffusely attached to the left 2-9th rib. This mass oppressed the heart, left lung and diaphragm.

  • PDF