• Title/Summary/Keyword: Diameter Measurement

Search Result 1,210, Processing Time 0.026 seconds

On the Development of In-process Measurement System for Guidance Core Diameter (유도심경의 인프로세스 측정시스템 개발)

  • 김정두
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.190-195
    • /
    • 1998
  • The guidance core is a principal part installed between the ink and the pen nib for the function of supplying ink to paper with reqularity. The current measurement of this product, Guidance core, in service is done by on operator with a micrometer, which could result in the decrease of productivity and working efficiency as well as causing errors. In this study, the existing measurement of the dialmeter of the Guidance core in the centerless grinding process is changed to the inprocessor measurement which enables consecutive measurement during the production of the Guidance core, and this system is also developed to work properly under bad circumstances and to have superior reliance and operational efficiency.

  • PDF

Measurement Data Comparison of Fast SAR Measurement System by Probe Arrays with Robot Scanning SAR Measurement System

  • Kim, Jun Hee;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.336-341
    • /
    • 2014
  • Dosimetry of radiating electromagnetic wave from mobile devices to human body has been evaluated by measuring Specific Absorption Rate (SAR). Usual SAR measurement system scans the volume by robot arm to evaluate RF power absorption to human body from wireless devices. It is possible to fast estimate the volume SAR by software deleting robot moving time with the 2D surface SAR data acquired by arrayed probes. This paper shows the principle of fast SAR measurement and the measured data comparison between the fast SAR system and the robot scanning system. Data of the fast SAR is well corresponding with data of robot scanning SAR within ${\pm}3$ dB, and its dynamic range covers from 10 mW/kg to 30 W/kg with 4.8 mm probe diameter.

Development of Effective Measurement Method for Burr Geometry (효율적인 버 형상 측정방법 개발)

  • 고성림;김원섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.81-87
    • /
    • 2003
  • Triangulation method, conoscopic holography method and interferometry method are analyzed for effective measurement of micro burr geometry, which is formed in micro drilling. To select proper sensor, the cross section of a cylinder with 0.5mm diameter is measured and the result shows that conoscopic holography method is effective for measuring highly inclined surface in cylinder. Burrs with 1.0mm and 30${\mu}{\textrm}{m}$ height are measured by three suggested methods. As a result, the conoscopic holography method is proved to be most proper in measuring burr geometry. Burr measurement system is developed, which consists of conoscopic laser sensor, X-Y table, controller and burr measurement program. Burrs can be measured automatically and the result is displayed in 3D shape

Measurement Algorithm of Bi-directional Diameter in Ground Spindles Using Extended Kalman Filter (확장 칼만필터를 이용한 연삭스핀들 외경의 측정알고리즘)

  • Bae, Jong-Il;Bae, Min-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.468-473
    • /
    • 2017
  • This paper presents an in-process measurement system for shaft radius measurement during grinding process. This system does not require to stop the grinding process, which can enhance productivity and quality. In order to measure the radius, the system employs an eddy current sensor that can measure without any contact with the shaft. This type of sensor is very appropriate because it is insensitive to interference such as cutting fluid, coolant, contact pressure, and wear. For data analysis, the measurement system is modeled as a linearized discrete form where the states with noise are estimated by an extended Kalman filter. This system has been validated through simulations and experiments.

Real-Time Measurement Technology for Bi-directional Diameter in Ground Spindle (연삭 스핀들류의 실시간 외경 측정기법)

  • Lee, Man-Hyung;Jung, Young-Il;Bae, Jong-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.3 s.96
    • /
    • pp.136-144
    • /
    • 1999
  • This paper presents an in-process measurement system for shaft radius measurement during grinding process. This system does not require to stop the grinding process, which can enhance productivity and quality. In order to measure the radius, the system employs an eddy current sensor that can measure without any contact with the shaft. This type of sensor is very appropriate because it is insensitive to interference such as cutting fluid, coolant, contact pressure, and wear. For data analysis, the measurement system is modeled as a linearized discrete form where the states with noise are estimated by an extended Kalman filter. This system has been validated through simulations and experiments.

  • PDF

The Atomization Performance of Ceramic Nozzles in Air Carrier Sprayer (공기운반분무기용 세라믹 노즐의 미립화 성능)

  • 박석호;노수영
    • Journal of Biosystems Engineering
    • /
    • v.20 no.3
    • /
    • pp.236-244
    • /
    • 1995
  • Droplet size is one of the important factors in the deposition and drift of agrichemical application. In this study, droplet size and its distribution of the three different sizes of ceramic hollow cone nozzles being used in the air carrier sprayer for apple production were investigated at the various nozzle pressures and the three air velocities. The Malvern particle size analyzer were used for the measurement of droplet size and its distribution. The important results emerged from th is study can be summarized as follows. 1. Discharged rate was increase with the increase of the nozzle diameter and pressure, amount of the difference was remarkable between the nozzle diameter of 1.0, 1.2 and 1.5 mm, but no difference were found between the diameter of 1.0 and 1.2 mm in the same nozzle pressure. 2. Mass median diameter were varied as 40~160 ${mu}m$ at the air velocity of 0 m/s, 70~140 ${mu}m$ of 15 m/s and 100~160 ${mu}m$ of 20 m/s 3. It appeared that the air velocity range of 15~20 m/s was desirable for both drift and deposition control in the given experimental conditions.

  • PDF

Quantitative Comparison of Acupuncture Needle Force Generation According to Diameter

  • Lee, YeonSun;Bong, SungMin;Kim, Eun Jung;Lee, Seung Deok;Jung, Chan Yung
    • Journal of Acupuncture Research
    • /
    • v.35 no.4
    • /
    • pp.238-243
    • /
    • 2018
  • Background: Various factors can alter the efficacy of acupuncture treatment, such as the location of points, manipulations, depth of insertion, needle retention time, and needle type. In this study, the effect of needle diameter on the efficacy of acupuncture treatment was quantitatively evaluated. Methods: Five acupuncture needles of different diameters used in clinical practice were compared. Force on the porcine tissue phantom was measured using a sensor. Lifting-thrusting and twisting-rotating movements were performed using a needle insertion-measurement system. After repeated measurements, force magnitude was calculated and compared. Following this, we correlated needle diameter and force magnitude during lifting-thrusting and twisting-rotating movements. Results: The force magnitude was significantly altered between needle diameters during lifting-thrusting movements, as shown by a significant positive correlation between needle diameter and force magnitude. In contrast, there was no difference in force magnitude with different needle diameters during twisting-rotating movements. Conclusion: Needle diameter can significantly affect stimuli and force magnitude dependent upon the type of manipulation. Research into the effect of other needle type characteristics and stimulation method is necessary to fully elucidate the role of acupuncture needle choice in treatment efficacy.

A study on the automatic inspection system for inner diameter and parallelism of automobile hubs (자동차 허브의 내경 및 평행도 자동검사 시스템에 대한 연구)

  • Kang, Byung-Soo;Yoo, Hyeong-Min
    • Design & Manufacturing
    • /
    • v.16 no.3
    • /
    • pp.16-21
    • /
    • 2022
  • In order to reduce the weight of parts and materials for the development of high-efficiency engines in accordance with the strengthening of automobile fuel efficiency regulations, the existing casting material is changed to a iron plate material, and plastic processing and turning operations are performed to lighten the weight and reduce the manufacturing cost. Among the pulley components applied to the damper pulley, the HUB product was manufactured by plastic machining instead of the existing casting process, and the inspection standardized for automating the inner diameter and parallelism measurement of the turning result of the new hub part with improved quality, and the inspection system for this Development of design and operation software to automate the inspection of the inner diameter and parallelism of the hub was described. The representative specifications of the development equipment are a hub inner diameter 22mm inspection system, a three-point inspection system with a parallelism of 0.15mm on the top.

A Study on the Particle Behavior in Turbulent Pulverized Coal Flame (난류 미분탄화염 내 입자거동에 관한 연구)

  • Hwang, Seung-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.12
    • /
    • pp.1111-1118
    • /
    • 2010
  • Combustion measurements based on optical techniques have recently become of major interest as tools not only for clarifying the combustion mechanism but also for validating the computational results for the combustion fields. In this study, the particle behavior in turbulent pulverized coal flame are investigated using advanced optical diagnostics. A laboratory-scale pulverized coal combustion burner is specially fabricated as open type in order to apply various optical measurement techniques. The detailed particle behavior is performed by LDV (laser Doppler velocimetry) and SDPA (shadow Doppler particle analyzer). It is observed that the particle mean diameter increase as the distance from burner increases, and this is found to be caused by the decrease of small particles' diameter and increase of large particles' diameter. This is because of result in the char reaction and the particle swelling due to devolatilization, respectively. The size-classified streamwise velocities of pulverized coal particles in the central region of the jet show the same magnitude, whereas those in the outer region are different depending on the particle size. The results show that the velocity and size-classified diameter of the pulverized coal particles in the flame can be measured well by SDPA.

A Study on the Temperature Accuracy due to Conditions of Thermocouple Installation (열전대의 설치상태에 따른 온도측정 오차에 관한 연구)

  • 선양래
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.49-54
    • /
    • 1982
  • In the equipments of industrial plant and marine engine, an exact temperature measurement is indispensable. Temperature measurement errors are induced by electrical and heat errors, and the insufficient immersion length of thermowell exerts an important effect to the haet error. In this paper, the author analyses the relation between temperature errors and the rate of immersion length to outside diameter (L/D) in order to reduce the heat errors.

  • PDF