• Title/Summary/Keyword: Diagnostic validation

Search Result 167, Processing Time 0.026 seconds

Evaluation of the cost-effectiveness of ASF detection with or without the use of on-field tests in different scenarios, in Sardinia

  • Cappai, Stefano;Loi, Federica;Rolesu, Sandro;Coccollone, Annamaria;Laddomada, Alberto;Sgarangella, Francesco;Masala, Sergio;Bitti, Giuseppe;Floris, Vincenzo;Desini, Pietro
    • Journal of Veterinary Science
    • /
    • v.21 no.2
    • /
    • pp.14.1-14.10
    • /
    • 2020
  • African swine fever (ASF) is a highly contagious disease of domestic pigs and wild boars (WBs). Without a vaccine, early antibody and antigen detection and rapid diagnosis are crucial for the effective prevention of the disease and the employment of control measures. In Sardinia, where 3 different suid populations coexisted closely for a long time, the disease persists since 1978. The recent ASF eradication plan involves more stringent measures to combat free-ranging pigs and any kind of illegality in the pig industry. However, critical issues such as the low level of hunter cooperation with veterinary services and the time required for ASF detection in the WBs killed during the hunting season still remain. Considering the need to deliver true ASF negative carcasses as early as possible, this study focuses on the evaluation and validation of a duplex pen-side test that simultaneously detects antibodies and antigens specific to ASF virus, to improve molecular diagnosis under field conditions. The main goal was to establish the specificity of the two pen-side tests performed simultaneously and to determine their ability to detect the true ASF negative carcasses among the hunted WBs. Blood and organ samples of the WBs hunted during the 2018/2019 hunting seasons were obtained. A total of 160 animals were tested using the pen-side kit test; samples were collected for virological and serological analyses. A specificity of 98% was observed considering the official laboratory tests as gold standards. The new diagnostic techniques could facilitate faster and cost-effective control of the disease.

Preliminary Validation Study of the Korean Version of the DSM-5 Level 2 Cross-Cutting Symptom Measure: Depression and Irritability for Parents of Children Aged 6-17 Years

  • Shin, Min-Sup;Kim, Bung-Nyun;Jang, Mirae;Shin, Hanbyul;Seo, Gyujin
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.33 no.3
    • /
    • pp.67-72
    • /
    • 2022
  • Objectives: This study investigated the reliability and validity of the Korean version of the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) Level 2 Cross-Cutting Symptom Measure-Patient-Reported Outcomes Measurement Information System (PROMIS)-Depression and the Irritability for parents of children aged 6-17 years. Methods: Participants were 190 children diagnosed with depressive disorder (n=14), anxiety disorder (n=21), attention-deficit/hyperactivity disorder (ADHD; n=111), ADHD with anxious depression (n=13), and tic disorder with somatic symptoms (n=31). Patients were 8-15 years of age. The participants' mothers completed the Korean versions of the DSM-5 Level 2 Cross-Cutting Symptom Measure-PROMIS Depression and Irritability (Affective Reactivity Index, ARI), and the Korean Child Behavior Checklist (K-CBCL). Using these data, we calculated the reliability coefficient and examined the concurrent and discriminant validity of the PROMIS Depression and the Irritability (ARI) scales for assessing depression and irritability in children. Results: The reliability coefficient of the PROMIS Depression scale (Cronbach's α) was 0.93. The correlation coefficient with the K-CBCL DSM emotional problem score was 0.71. The PROMIS Depression scale significantly discriminated children with depressive disorders from those with other conditions. The reliability coefficient of the Irritability (ARI) scale was 0.91, suggesting its high reliability. Conclusion: Our results suggest that the Korean version of the DSM-5 Level 2 Cross-Cutting Symptom Measure for Depression and Irritability Scales for parents of children aged 6-17 years is reliable and valid and may be an efficient alternative to the K-CBCL.

Deep learning-based apical lesion segmentation from panoramic radiographs

  • Il-Seok, Song;Hak-Kyun, Shin;Ju-Hee, Kang;Jo-Eun, Kim;Kyung-Hoe, Huh;Won-Jin, Yi;Sam-Sun, Lee;Min-Suk, Heo
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.351-357
    • /
    • 2022
  • Purpose: Convolutional neural networks (CNNs) have rapidly emerged as one of the most promising artificial intelligence methods in the field of medical and dental research. CNNs can provide an effective diagnostic methodology allowing for the detection of early-staged diseases. Therefore, this study aimed to evaluate the performance of a deep CNN algorithm for apical lesion segmentation from panoramic radiographs. Materials and Methods: A total of 1000 panoramic images showing apical lesions were separated into training (n=800, 80%), validation (n=100, 10%), and test (n=100, 10%) datasets. The performance of identifying apical lesions was evaluated by calculating the precision, recall, and F1-score. Results: In the test group of 180 apical lesions, 147 lesions were segmented from panoramic radiographs with an intersection over union (IoU) threshold of 0.3. The F1-score values, as a measure of performance, were 0.828, 0.815, and 0.742, respectively, with IoU thresholds of 0.3, 0.4, and 0.5. Conclusion: This study showed the potential utility of a deep learning-guided approach for the segmentation of apical lesions. The deep CNN algorithm using U-Net demonstrated considerably high performance in detecting apical lesions.

Development and validation of a clinical phantom reproducing various lesions for oral and maxillofacial radiology research

  • Han-Gyeol Yeom;Jo-Eun Kim;Kyung-Hoe Huh;Won-Jin Yi;Min-Suk Heo;Sam-Sun Lee
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.345-353
    • /
    • 2023
  • Purpose: The objective of this study was to propose a method for developing a clinical phantom to reproduce various diseases that are clinically prevalent in the field of dentistry. This could facilitate diverse clinical research without unnecessarily exposing patients to radiation. Materials and Methods: This study utilized a single dry skull, which was visually and radiographically examined to evaluate its condition. Existing lesions on the dry skull were preserved, and other relevant lesions were artificially created as necessary. These lesions were then documented using intraoral radiography and cone-beam computed tomography. Once all pre-existing and reproduced lesions were confirmed by the consensus of 2 oral and maxillofacial radiologists, the skull was embedded in a soft tissue substitute. To validate the process, cone-beam computed tomography scans and panoramic radiographs were obtained of the fabricated phantom. All acquired images were subsequently evaluated. Results: Most lesions could be identified on panoramic radiographs, although some sialoliths and cracked teeth were confirmed only through cone-beam computed tomographic images. A small gap was observed between the epoxy resin and the bone structures. However, 2 oral and maxillofacial radiologists agreed that this space did not meaningfully impact the interpretation process. Conclusion: The newly developed phantom has potential for use as a standardized phantom within the dental field. It may be utilized for a variety of imaging studies, not only for optimization purposes, but also for addressing other experimental issues related to both 2- and 3-dimensional diagnostic radiography.

Convolutional neural network of age-related trends digital radiographs of medial clavicle in a Thai population: a preliminary study

  • Phisamon Kengkard;Jirachaya Choovuthayakorn;Chollada Mahakkanukrauh;Nadee Chitapanarux;Pittayarat Intasuwan;Yanumart Malatong;Apichat Sinthubua;Patison Palee;Sakarat Na Lampang;Pasuk Mahakkanukrauh
    • Anatomy and Cell Biology
    • /
    • v.56 no.1
    • /
    • pp.86-93
    • /
    • 2023
  • Age at death estimation has always been a crucial yet challenging part of identification process in forensic field. The use of human skeletons have long been explored using the principle of macro and micro-architecture change in correlation with increasing age. The clavicle is recommended as the best candidate for accurate age estimation because of its accessibility, time to maturation and minimal effect from weight. Our study applies pre-trained convolutional neural network in order to achieve the most accurate and cost effective age estimation model using clavicular bone. The total of 988 clavicles of Thai population with known age and sex were radiographed using Kodak 9000 Extra-oral Imaging System. The radiographs then went through preprocessing protocol which include region of interest selection and quality assessment. Additional samples were generated using generative adversarial network. The total clavicular images used in this study were 3,999 which were then separated into training and test set, and the test set were subsequently categorized into 7 age groups. GoogLeNet was modified at two layers and fine tuned the parameters. The highest validation accuracy was 89.02% but the test set achieved only 30% accuracy. Our results show that the use of medial clavicular radiographs has a potential in the field of age at death estimation, thus, further study is recommended.

Multi-block PCA for Sensor Fault Detection and Diagnosis of City Gas Network (도시가스 배관망의 고장 탐지 및 진단을 위한 다중블록 PCA 적용 연구)

  • Yeon-ju Baek;Tae-Ryong Lee;Jong-Seun Kim;Hong-Cheol Ko
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.2
    • /
    • pp.38-46
    • /
    • 2024
  • The city gas pipeline network is characterized by being widely distributed and hierarchically connected in a complex manner over a wide area. In order to monitor the status of the widely distributed network pressures with high precision, Multi-block PCA(MBPCA) is recommended. However, while MBPCA has excellent performance in identifying faulty sensors as the number of sensors increases, the fault detection performance deteriorates, and also there is a problem that the model needs to be updated entirely even if minor changes occur. In this study, we developed fault detectability index and fault identificability index to determine the effectiveness of MBPCA application block by block. Based on these indices, we distinguished MBPCA and PCA blocks and developed a fault detection and diagnostic system for the city gas pipeline network of Haean Energy Co., Ltd., and were able to solve the problems that arise when there are many sensors.

Validation of Korean Diagnostic Scale of Multiple Intelligence (한국형 다중지능 진단도구의 타당화)

  • Moon, Yong-Lin;Yu, Gyeong-Jae
    • (The) Korean Journal of Educational Psychology
    • /
    • v.23 no.3
    • /
    • pp.645-663
    • /
    • 2009
  • The purpose of this study is to develop and verify a Korean Diagnostic Scale of Multiple Intelligence(MI), which will be an alternative test to avoid problems with former Shearer's MI test and to adopt H. Gardner's suggestions to develop MI assessment. The test is developed 5 types; kindergartner, elementary lower grader, elementary upper grader, middle schooler, high schooler test. A form of test is diversified with 3 types; multiple-choice items for accomplishment, true or false items for ability, and self-reported items with likert scale for interest and ability. According to H. Gardner's suggestions, we have tried to reanalyze key component of MI, analyze an overlapping or hierarchical relationship between intelligences, develop intelligences-fair items, diversify form of item. We have developed a final standardized test through a primary, secondary preliminary-test analysis, and sampled 5,585 students by age, gender, and regional groups. As a result of this sampling test, we can get a norm score and compare individuals with other's score relatively. To verify this test, we analyzed behavior observation, mean, standard deviation, a percentage of correct answers, reliability of each test type, correlation between intelligence scales, Kruskal-Wallis test of mean rank of career choice by intelligences. As a result of correlation analysis between sub-intelligence scales, we can conclude that this MI test is satisfied with intelligence independent assumption. Besides, as non-parametric statistics test(Kruskal-Wallis) of career choice by intelligences, we can identify that MI is related with domain of career choice. This test is not a linguistic and logical-mathematical biased test but a intelligences-fair test. It makes us compare individual's potential with a norm score. Besides, it could be useful as a means of educational prescription or counsel in comparison with ability, interest, and accomplishment of individual. But this test is limited to do factor or correlation analysis between types of sub-test, because items are minimized for a time-constraint and a heavy burden of test receiver. But if it could be tested with increased items by two sessions, further research could be expected to get over this constraints and do a further validation analysis.

A Validation Study of the Korean Version of Social Communication Questionnaire (한국어판 사회적 의사소통 설문지 타당화 연구)

  • Kim, Joo-Hyun;Sunwoo, Hyun-Jung;Park, Su-Bin;Noh, Dong-Hyun;Jung, Yeon Kyung;Cho, In-Hee;Cho, Soo-Churl;Kim, Bung-Nyun;Shin, Min-Sup;Kim, Jae-Won;Park, Tae-Won;Son, Jung-Woo;Chung, Un-Sun;Yoo, Hee Jeong
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.26 no.3
    • /
    • pp.197-208
    • /
    • 2015
  • Objectives : The purposes of this study were to examine the reliability and validity of the Korean version of Social Communication Questionnaire (K-SCQ) and to determine cut-off scores for diagnosis of autism spectrum disorder (ASD). Methods : A total of 166 subjects with ASD and their 186 unaffected siblings were recruited through child psychiatry clinics of university hospitals. Board certified child psychiatrists screened all probands suspected to have ASD based on the Diagnostic and Statistical Manual of Mental Disorders, fourth edition. To confirm the diagnoses, the Korean versions of the Autism Diagnostic Observation Schedule and the Autism Diagnostic Interview-Revised (K-ADI-R) were administered to all the subjects. All parents completed the K-SCQ and Social Responsiveness Scale (SRS). The non-ASD siblings were evaluated with the same instruments as the probands with ASD. We performed a factor analysis to examine the structure of K-SCQ. For testing the validity of K-SCQ, we compared the difference in Lifetime and Current scores of probands with ASD and their non-ASD siblings using t-test and analysis of covariance. Correlations between the K-SCQ and other measurements of ASD symptomatology, including K-ADI-R totals and domain scores and SRS, were examined. Receiver operation characteristic curve analysis was performed to extract cutoff scores discriminating affection status. Results : Four factors were extracted through factor analysis of K-SCQ ; 1) social relation and play, 2) stereotyped behavior, 3) social behavior, and 4) abnormal language. Cronbach's internal consistency was .95 in K-SCQ Lifetime, and .93 in K-SCQ Current. There were significant differences in total score of K-SCQ, both in Lifetime and Current between the ASD group and non-ASD siblings group (p<.05). K-SCQ scores were significantly correlated with K-ADI-R subdomain scores and SRS total scores (p<.05). The best-estimate cut-off scores of K-SCQ for diagnosis of ASD were 12 for 48 months and over, and 10 for below 47 months. Conclusion : Our findings suggest that the K-SCQ is a reliable and valid instrument for screening autistic symptoms in the Korean population. Lower cut-off scores than the original English version might be considered when using it as a screening instrument of ASD.

Meaning of the DR-$70^{TM}$ Immunoassay for Patients with the Malignant Tumor (악성 종양 환자에 대한 DR-$70^{TM}$ 면역 분석법의 의의: Validation Study)

  • Lee, Ki-Ho;Cho, Dong-Hee;Kim, Sang-Man;Lee, Duck-Joo;Kim, Kwang-Min
    • IMMUNE NETWORK
    • /
    • v.6 no.1
    • /
    • pp.43-51
    • /
    • 2006
  • Background: The DR-$70^{TM}$ immunoassay is a newly developed cancer diagnostic test which quantifies the serum fibrin degradation products (FDP), produced during fibrinolysis, by antibody reaction. The purpose of this study was to evaluate the potential of DR-$70^{TM}$ Immunoassay in screening malignant tumor. Methods: Sample subjects were 4,169 adults, both male and female, who visited the health promotion center of a general hospital from March 2004 to April 2005 and underwent the DR-$70^{TM}$ immunoassay test and other tests for cancer diagnosis. The patient group was defined as 42 adults out of the sample subjects who were newly diagnosed with cancer during the same time period when the DR-$70^{TM}$ immunoassay test was performed. Final confirmation of a malignant tumor was made by pathological analysis. Results: The mean DR-$70^{TM}$ level was $0.83{\pm}0.65{\mu}g/ml$ (range: 0.00 (0.0001)${\sim}7.42{\mu}g/ml)$ in the control group (n=4,127) as opposed to $2.70{\pm}2.33{\mu}g/ml$ (range: $0.12{\sim}9.30{\mu}g/ml)$ in the cancer group (n=42), and statistical significance was established (p<0.0001, Student t-test). When categorized by the type of malignant tumor, all cancer patients with the exception of the subgroups of colon and rectal cancer showed significantly higher mean DR-$70^{TM}$ levels compared with the control group (p<0.0001, Kruscal-Wallis test). The receiver operating characteristic (ROC) curve analysis revealed ${\geq}1.091{\mu}g/ml$ as the best cut-off value. Using this cut-off value, the DR-$70^{TM}$ immunoassay produced a sensitivity of 71.4%, a specificity of 70.1%, a positive predictability of 69.4%, and a negative predictability of 69.2% (1). Conclusion: A significant increase in the mean DR-$70^{TM}$ value was observed in the cancer group (thyroidal, gastric, breast, hepatic and ovarian) com pared with the control group. In particular, the specificity and sensitivity of the DR-$70^{TM}$ immunoassay was relatively high in the subgroups of breast, gastric, and thyroidal cancer patients. There is need for further studies on a large number of malignant tumor patients to see how the DR-$70^{TM}$ level might be changed according to the differentiation grade and postoperative prognosis of the malignant tumor.

An Example of Test on Differences of Pulse Waveform Characteristics at Cun, Guan and Chi (촌, 관, 척 위치의 맥파 특징 차이 검정에 대한 1례)

  • Lee, Jeon;Lee, Yu-Jung;Jeon, Young-Ju;Lee, Hae-Jung;Ryu, Hyun-Hee;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.2
    • /
    • pp.107-112
    • /
    • 2008
  • Although the pulse diagnosis position, Guan is apart from Cun or Chi by only $10{\sim}20$ mm at most, traditional medical doctors applies different indent pressures and even they states different pulse images are felt at Cun, Guan and Chi, To support their clinical behaviors, in this study, we tested statistically whether there are differences in pulse waveform measured at these three positions with SphygmoCor system used world widely, A 30 years old female subject without any evidence of cardiovascular diseases was involved in this experiment. Radial pulse waves were recorded at three different positions on left lower arm 10 times at three positions-Cun, Guan and Chi. With ANOVA, we tested whether, among three different positions. there are any differences in 12 parameters of radial pulse waveform and in estimated AIx(Augmentation Index) as an arterial stiffness index extracted from radial pulse waveform. As results, differences in optimal indent pressure h0 were observed at different measuring positions(P<0.001) but not significantly different. And pulse pressure his were found to be different(Chi$22.60{\pm}3.06%,\;18.60{\pm}3.37%\;and\;26.4{\pm}5.02%$ respectively. Consequently. AIx at Gwan seems to be lowest and that at Chi seems to be highest. So. we assert the AIx at Chi is likely to be overestimated. In further studies. we want to examine what make differences in these parameters between measuring positions. And it also seems to be worthy to investigate the relationship between the depth of radial artery and AIx. And, ultimately, we need to determine the best measuring process including measuring position, hold-down pressure, signal quality validation and so on. so to achieve the optimal waveform which represents subject's health condition for both western medicine and traditional medicine.

  • PDF