Role of endoscopy in gastroesophageal reflux disease

  • Daniel Martin Simadibrata;Elvira Lesmana;Ronnie Fass
    • Clinical Endoscopy
    • /
    • v.56 no.6
    • /
    • pp.681-692
    • /
    • 2023
  • In general, gastroesophageal reflux disease (GERD) is diagnosed clinically based on typical symptoms and/or response to proton pump inhibitor treatment. Upper gastrointestinal endoscopy is reserved for patients presenting with alarm symptoms, such as dysphagia, odynophagia, significant weight loss, gastrointestinal bleeding, or anorexia; those who meet the criteria for Barrett's esophagus screening; those who report a lack or partial response to proton pump inhibitor treatment; and those with prior endoscopic or surgical anti-reflux interventions. Newer endoscopic techniques are primarily used to increase diagnostic yield and provide an alternative to medical or surgical treatment for GERD. The available endoscopic modalities for the diagnosis of GERD include conventional endoscopy with white-light imaging, high-resolution and high-magnification endoscopy, chromoendoscopy, image-enhanced endoscopy (narrow-band imaging, I- SCAN, flexible spectral imaging color enhancement, blue laser imaging, and linked color imaging), and confocal laser endomicroscopy. Endoscopic techniques for treating GERD include esophageal radiofrequency energy delivery/Stretta procedure, transoral incisionless fundoplication, and endoscopic full-thickness plication. Other novel techniques include anti-reflux mucosectomy, peroral endoscopic cardiac constriction, endoscopic submucosal dissection, and endoscopic band ligation. Currently, many of the new endoscopic techniques are not widely available, and their use is limited to centers of excellence.

The role of needle-based confocal laser endomicroscopy in the diagnosis of pancreatic neuroendocrine tumors

  • Masanori Yamada;Kazuo Hara;Nobumasa Mizuno;Shin Haba;Takamichi Kuwahara;Nozomi Okuno;Yasuhiro Kuraishi;Takafumi Yanaidani;Sho Ishikawa;Tsukasa Yasuda;Toshitaka Fukui
    • Clinical Endoscopy
    • /
    • v.57 no.3
    • /
    • pp.393-401
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a highly accurate method for diagnosing pancreatic neuroendocrine tumors (PNETs); however, some PNETs are difficult to diagnose. Recently, the efficacy of needle-based confocal laser endomicroscopy (nCLE) in diagnosing solid pancreatic masses has been reported. However, the efficacy of nCLE in the diagnosis of PNETs remains unknown and only a small number of cases have been reported. Hence, this study aimed to evaluate the efficacy of nCLE in the diagnosis of PNETs. Methods: This single-center retrospective study evaluated 30 consecutive patients with suspected PNETs on contrast-enhanced computed tomography, who consented to nCLE combined with EUS-FNA and were diagnosed using EUS-FNA or surgical resection. The diagnostic criteria for PNETs using nCLE were based on the nesting and trabecular and glandular arrangement of tumor cell clusters surrounded by capillary vessels and fibrosis, as reported in previous studies. Results: The diagnosis using nCLE was classified into three categories: misdiagnosis in three cases (10%), non-diagnostic in six cases (20%), and diagnostic in 21 cases (70%). nCLE was able to diagnose PNET in one of the two cases with inconclusive EUS-FNA. Conclusions: Although further development of the resolution and optimization of the diagnostic criteria are required, nCLE may constitute a useful diagnostic option in cases of inconclusive EUS-FNA for PNETs.

Impact of a simple non-invasive nasal mask device on intraprocedural hypoxemia in overweight individuals undergoing upper gastrointestinal endoscopy with sedation provided by a non-anesthesiologist provider

  • Jan Drews;Jonas Harder;Hannah Kaiser;Miriam Soenarjo;Dorothee Spahlinger;Peter Wohlmuth;Sebastian Wirtz;Ralf Eberhardt;Florian Bornitz;Torsten Bunde;Thomas von Hahn
    • Clinical Endoscopy
    • /
    • v.57 no.2
    • /
    • pp.196-202
    • /
    • 2024
  • Background/Aims: Hypoxemia is a common side effect of propofol sedation during endoscopy. Applying mild positive airway pressure (PAP) using a nasal mask may offer a simple way to reduce such events and optimize the conditions for diagnostic and therapeutic upper gastrointestinal endoscopies. Methods: We compared overweight patients (body mass index >25 kg/m2) with a nasal PAP mask or standard nasal cannula undergoing upper gastrointestinal endoscopies by non-anesthesiologists who provided propofol sedation. Outcome parameters included the frequency and severity of hypoxemic episodes. Results: We analyzed 102 procedures in 51 patients with nasal PAP masks and 51 controls. Episodes of hypoxemia (oxygen saturation [SpO2] <90% at any time during sedation) occurred in 25 (49.0%) controls compared to 8 (15.7%) patients with nasal PAP masks (p<0.001). Severe hypoxemia (SpO2 <80%) occurred in three individuals (5.9%) in both groups. The mean delta between baseline SpO2 and the lowest SpO2 recorded was significantly decreased among patients with nasal PAP mask compared to controls (3.7 and 8.2 percentage points difference, respectively). There were significantly fewer airway interventions performed in the nasal PAP mask group (15.7% vs. 41.2%, p=0.008). Conclusions: Using a nasal PAP mask may be a simple means of increasing patient safety and ease of examination.

CEPHALOMETRIC AND NASOPHARYNGEAL ENDOSCOPIC STUDY IN PATIENTS WITH OBSTRUCTIVE SLEEP APNEA (폐쇄성 수면 무호흡증 환자에 있어서 두부방사선 계측 분석 및 인후 내시경적 연구)

  • Choi, Jin-Young;Engelke, W.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.2
    • /
    • pp.149-165
    • /
    • 1999
  • The pathomechanism of obstructive sleep apnea(OSA) is not clearly elucidated. The possible mechanisms are pathologic reduction of pharyngeal muscular tonus during sleep, abnormal anatomical stenosis of nasopharyx or a combination of the above two mechanisms. It is very important to find the cause(anatomical location or pathologic dynamic change) of OSA in order to treat it. Cephalometric analysis in patients with obstructive sleep apnea is a good method for evaluating anatomical morphologic change but it cannot give any information about the dynamic changes occurring during sleep. On the contrary, nasopharyngeal endoscopy offer 3 dimensional image and information about the dynamic changes. Accordingly, these two diagnostic tools can be utilize in the diagnosis and treatment planning of OSA Cephalometric analysis of craniofacial skeletal and soft tissue morphology in 53 patients with OSA and 43 controls was performed and cephalometric analysis and nasopharygeal endoscopy were performed in 9 patients with OSA in order to come up with individualized therapy plans. Following results were obtained ; Patients with OSA showed 1. body weight gain 2. clockwise mandibular rotation 3. increased anterior lower facial height 4. inferiorly positioned hyoid bone 5. increased length of soft palate 6. decreased sagittal dimension of nasopharyx 7. increased vertical length of inferior collapsable nasopharyx 8. increased length of tongue Through cephalometric analysis and nasopharygeal endoscopy(mutually cooperative in diagnosis), 9. one can find the possible origin of OSA and make a adequate individualized therapy plan and predict accurate prognosis. Cephalometric analysis and nasopharygeal endoscopy are highly recommended as a diagnostic aid in OSA patients

  • PDF

Does computer-aided diagnostic endoscopy improve the detection of commonly missed polyps? A meta-analysis

  • Arun Sivananthan;Scarlet Nazarian;Lakshmana Ayaru;Kinesh Patel;Hutan Ashrafian;Ara Darzi;Nisha Patel
    • Clinical Endoscopy
    • /
    • v.55 no.3
    • /
    • pp.355-364
    • /
    • 2022
  • Background/Aims: Colonoscopy is the gold standard diagnostic method for colorectal neoplasia, allowing detection and resection of adenomatous polyps; however, significant proportions of adenomas are missed. Computer-aided detection (CADe) systems in endoscopy are currently available to help identify lesions. Diminutive (≤5 mm) and nonpedunculated polyps are most commonly missed. This meta-analysis aimed to assess whether CADe systems can improve the real-time detection of these commonly missed lesions. Methods: A comprehensive literature search was performed. Randomized controlled trials evaluating CADe systems categorized by morphology and lesion size were included. The mean number of polyps and adenomas per patient was derived. Independent proportions and their differences were calculated using DerSimonian and Laird random-effects modeling. Results: Seven studies, including 2,595 CADe-assisted colonoscopies and 2,622 conventional colonoscopies, were analyzed. CADe-assisted colonoscopy demonstrated an 80% increase in the mean number of diminutive adenomas detected per patient compared with conventional colonoscopy (0.31 vs. 0.17; effect size, 0.13; 95% confidence interval [CI], 0.09-0.18); it also demonstrated a 91.7% increase in the mean number of nonpedunculated adenomas detected per patient (0.32 vs. 0.19; effect size, 0.05; 95% CI, 0.02-0.07). Conclusions: CADe-assisted endoscopy significantly improved the detection of most commonly missed adenomas. Although this method is a potentially exciting technology, limitations still apply to current data, prompting the need for further real-time studies.

Quality indicators in endoscopic retrograde cholangiopancreatography: a brief review of established guidelines

  • Zubin Dev Sharma;Rajesh Puri
    • Clinical Endoscopy
    • /
    • v.56 no.3
    • /
    • pp.290-297
    • /
    • 2023
  • Endoscopic retrograde cholangiopancreatography (ERCP) is an invasive endoscopic technique that has many diagnostic and therapeutic implications. It is a procedure with small but significant life-threatening complications. To ensure the best possible care, minimize complications, and improve the quality of health care, a constant review of the performance of the operator using ideal benchmark standards is needed. Hence, quality indicators are necessary. The American and European Societies of Gastrointestinal Endoscopy have provided guidelines on quality measures for ERCP, which describe the skills to be developed and training to be implemented in performing quality ERCP. These guidelines have divided the indicators into pre-procedure, intraprocedural, and post-procedure measures. The focus of this article was to review the quality indicators of ERCP.

Two Cases of Jejunal Gastrointestinal Stromal Tumor Diagnosed by Capsule Endoscope (캡슐내시경으로 발견된 공장의 위장관 간질성 종양 2 예)

  • Choi, Jae-Won;Mun, Hui-Jeong;Jang, Byung-Ik;Kim, Tae-Nyeun;Song, Sun-Kyo;Bae, Young-Kyong;Lee, Ji-Eun
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.1
    • /
    • pp.131-137
    • /
    • 2006
  • Small bowel tumors have been difficult to diagnose because of low incidence and absence of specific symptoms. There are no efficient and accurate tests available for diagnosis. Capsule endoscopy is an efficient diagnostic tool for small bowel disease and obscure gastrointestinal bleeding. We diagnosed two cases of small bowel gastrointestinal stromal tumor (GIST) diagnosed by capsule endoscopy that were treated by surgery. A 68 year old male presented with abdominal pain. The capsule endoscopy showed fungating ulcer mass at the jejunum. A 55 year female presented with melena. The capsule endoscopy showed an intraluminal protruding mass with a superficial ulcer at the jejunum. Two cases were diagnosed with GIST after surgery. We report these two case diagnosed by capsule endoscopy and review the medical literature.

  • PDF

Exploring quality indicators for the detection of Helicobacter pylori-naïve gastric cancer: a cross-sectional nationwide survey

  • Fumiaki Ishibashi;Toshiaki Hirasawa;Hiroya Ueyama;Yohei Minato;Sho Suzuki
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.460-469
    • /
    • 2023
  • Background/Aims: Diagnosis of Helicobacter pylori-naive gastric cancer (HPNGC) is becoming increasingly important. This study aimed to explore the quality indicators for HPNGC detection. Methods: We conducted a cross-sectional, nationwide, web-based survey of gastrointestinal endoscopists in Japan. In addition to questions about the number of HPNGC cases detected in a year and basic information, the questionnaire also consisted of 28 questions: (1) 18 about HPNGC awareness, (2) six about diagnostic proactiveness, and (3) four about interest in HPNGC. Results: Valid responses were obtained from 712 endoscopists. The Japan Gastroenterological Endoscopy Society-certified endoscopists had a significantly higher HPNGC detection rate than the nonspecialists (0.42% vs. 0.32%, respectively; p=0.008). The results of the multiple regression analysis showed that Japan Gastroenterological Endoscopy Society certification and high awareness and interest scores were independent predictors of the HPNGC detection rate (p=0.012, p<0.001, p=0.024, respectively). Principal component analysis showed that the endoscopists who attended conferences for collecting information on HPNGC had a higher level of awareness. Conclusions: To improve the detection of HPNGC, it is necessary to increase the awareness of the disease. It is hoped that relevant societies will play an important role in endoscopists' education.

Preclinical study of a novel ingestible bleeding sensor for upper gastrointestinal bleeding

  • Kimberly F. Schuster;Christopher C. Thompson;Marvin Ryou
    • Clinical Endoscopy
    • /
    • v.57 no.1
    • /
    • pp.73-81
    • /
    • 2024
  • Background/Aims: Upper gastrointestinal bleeding (UGIB) is a life-threatening condition that necessitates early identification and intervention and is associated with substantial morbidity, mortality, and socioeconomic burden. However, several diagnostic challenges remain regarding risk stratification and the optimal timing of endoscopy. The PillSense System is a noninvasive device developed to detect blood in patients with UGIB in real time. This study aimed to assess the safety and performance characteristics of PillSense using a simulated bleeding model. Methods: A preclinical study was performed using an in vivo porcine model (14 animals). Fourteen PillSense capsules were endoscopically placed in the stomach and blood was injected into the stomach to simulate bleeding. The safety and sensitivity of blood detection and pill excretion were also investigated. Results: All the sensors successfully detected the presence or absence of blood. The minimum threshold was 9% blood concentration, with additional detection of increasing concentrations of up to 22.5% blood. All the sensors passed naturally through the gastrointestinal tract. Conclusions: This study demonstrated the ability of the PillSense System sensor to detect UGIB across a wide range of blood concentrations. This ingestible device detects UGIB in real time and has the potential to be an effective tool to supplement the current standard of care. These favorable results will be further investigated in future clinical studies.

Influence of biliary stents on the diagnostic outcome of endoscopic ultrasound-guided tissue acquisition from solid pancreatic lesions: a systematic review and meta-analysis

  • Suprabhat Giri;Shivaraj Afzalpurkar;Sumaswi Angadi;Jijo Varghese;Sridhar Sundaram
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.169-179
    • /
    • 2023
  • Background/Aims: This meta-analysis analyzed the effect of an indwelling biliary stent on endoscopic ultrasound (EUS)-guided tissue acquisition from pancreatic lesions. Methods: A literature search was performed to identify studies published between 2000 and July 2022 comparing the diagnostic outcomes of EUS-tissue acquisition (TA) in patients with or without biliary stents. For non-strict criteria, samples reported as malignant or suspicious for malignancy were included, whereas for strict criteria, only samples reported as malignant were included in the analysis. Results: Nine studies were included in this analysis. The odds of an accurate diagnosis were significantly lower in patients with indwelling stents using both non-strict (odds ratio [OR], 0.68; 95% confidence interval [CI], 0.52-0.90) and strict criteria (OR, 0.58; 95% CI, 0.46-0.74). The pooled sensitivity with and without stents were similar (87% vs. 91%) using non-strict criteria. However, patients with stents had a lower pooled sensitivity (79% vs. 88%) when using strict criteria. The sample inadequacy rate was comparable between groups (OR, 1.12; 95% CI, 0.76-1.65). The diagnostic accuracy and sample inadequacy were comparable between plastic and metal biliary stents. Conclusions: The presence of a biliary stent may negatively affect the diagnostic outcome of EUS-TA for pancreatic lesions.