• Title/Summary/Keyword: Diagnostic X-ray

Search Result 600, Processing Time 0.044 seconds

Radiation Dose Reduction of Lens by Adjusting Table Height and Magnification Ratio in 3D Cerebral Angiography (삼차원 뇌혈관조영술에서 테이블 높이와 확대율 조절에 따른 수정체 선량 감소에 대한 연구)

  • Yoon, Jong-Tae;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.313-320
    • /
    • 2022
  • Both angiography and interventional procedures accompanied by angiography provide many diagnostic and therapeutic benefits to patients and are rapidly increasing. However, unlike general radiography or computed tomography using the same X-ray, the amount of radiation is quite high, but the dose range can vary considerably for each patient and operator. The high sensitivity of the lens to radiation during cerebral angiography and neurointervention is already well known, and although there are many related studies, it is insufficient to easily reduce radiation in diagnosis and treatment. In this situation, in particular, by adding three-dimensional rotational angiography (3D-RA) to the existing two-dimensional (2D) angiography, it is now possible to make an accurate diagnosis. However, since this 3D-RA acquires images through projection of more radiation than before, the exposure dose of the lens may be higher. Therefore, we tried to analyze whether the radiation dose of the lens can be reduced by moving the lens out of the field range by adjusting the table height and magnification ratio during the examination using 3D-RA. The surface dose was measured using a rando phantom and a radiophotoluminescent glass dosimeter (PLD) and the radiation dose was compared by adjusting the table height and magnification ratio based on the central point. As a result, it was found that the radiation dose of the lens decreased as the table height increased from the central point, that is, as the lens was out of the field of view. In conclusion, in 3D-RA, moving the table position of about 2 cm in height will make a significant contribution to the dose reduction of the lens, and it was confirmed that adjusting the magnification ratio can also reduce the surface dose of the lens.

Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment

  • Song, Chang-Ho;Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.283-288
    • /
    • 2022
  • Purpose: This study was conducted to measure the radiation exposure and image quality of various cone-beam computed tomography (CBCT) machines under common clinical conditions and to analyze the correlation between them. Materials and Methods: Seven CBCT machines used frequently in clinical practice were selected. Because each machine has various sizes of fields of view (FOVs), 1 large FOV and 1 small FOV were selected for each machine. Radiation exposure was measured using a dose-area product (DAP) meter. The quality of the CBCT images was analyzed using 8 image quality parameters obtained using a dental volume tomography phantom. For statistical analysis, regression analysis using a generalized linear model was used. Results: Polymethyl-methacrylate (PMMA) noise and modulation transfer function (MTF) 10% showed statistically significant correlations with DAP values, presenting positive and negative correlations, respectively (P<0.05). Image quality parameters other than PMMA noise and MTF 10% did not demonstrate statistically significant correlations with DAP values. Conclusion: As radiation exposure and image quality are not proportionally related in clinically used equipment, it is necessary to evaluate and monitor radiation exposure and image quality separately.

An Efficiency Analysis of an Artificial Intelligence Medical Image Analysis Software System : Focusing on the Time Behavior of ISO/IEC 25023 Software Quality Requirements (인공지능 기술 기반의 의료영상 판독 보조 시스템의 효율성 분석 : ISO/IEC 25023 소프트웨어 품질 요구사항의 Time Behavior를 중심으로)

  • Chang-Hwa Han;Young-Hwang Jeon;Jae-Bok Han;Jong-Nam Song
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.939-945
    • /
    • 2023
  • This study analyzes the 'performance efficiency' of AI-based reading assistance systems in the field of radiology by measuring their 'time behavior' properties. Due to the increase in medical images and the limited number of radiologists, the adoption of AI-based solutions is escalating, stimulating a multitude of studies in this area. Contrary to the majority of past research which centered on AI's diagnostic precision, this study underlines the significance of time behavior. Using 50 chest X-ray PA images, the system processed images in an average of 15.24 seconds, demonstrating high consistency and reliability, which is on par with leading global AI platforms, suggesting the potential for significant improvements in radiology workflow efficiency. We expect AI technology to play a large role in the field of radiology and help improve overall healthcare quality and efficiency.

Early and Atypical Radiologic Presentations of Pulmonary Langerhans Cell Histiocytosis: A Report of Two Cases (폐 랑게르한스 조직구 증식증의 비전형적 영상 소견: 2예에 대한 보고)

  • Kyunghwa Ryu;Bo Da Nam;Jung Hwa Hwang;Dong Won Kim;Young Woo Park;Hong Chul Oh;Soo Bin Park
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.756-763
    • /
    • 2021
  • Pulmonary Langerhans cell histiocytosis (PLCH) is a rare, multi-systemic disease primarily affecting young male adults with a history of smoking. The two patients with PLCH in our report showed relatively early and atypical radiologic presentations at initial evaluation. On chest CT, PLCH presents variable radiologic features depending on the evolutional stage of the disease. Atypical CT features of PLCH may render precise radiologic diagnosis difficult and usually require lung biopsy for a confirmation of the diagnosis. Our case review is aimed at raising the awareness of radiologists on the atypical CT features of PLCH, to help make accurate radiologic diagnosis and prevent unnecessary and invasive diagnostic procedures.

Atypical Manifestation of Primary Hepatocellular Carcinoma and Hepatic Malignancy Mimicking Lesions (원발성 간세포암의 비특이적 영상 소견 및 간암으로 오인될 수 있는 병변에 대한 영상의학적 고찰)

  • Jiyoung Yoon;So Hyun Park;Su Joa Ahn;Young Sup Shim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.4
    • /
    • pp.808-829
    • /
    • 2022
  • Hepatocellular carcinoma (HCC) can be diagnosed noninvasively on multiphasic CT and MRI based on its distinctive imaging findings. These features include arterial phase hyperenhancement and washout on portal or delayed phase images. However, radiologists face significant diagnostic challenges because some HCCs exhibit atypical imaging characteristics. In addition to many HCC-mimicking lesions, such as arterioportal shunts, combined HCC-cholangiocarcinoma, intrahepatic cholangiocarcinoma, and hemangioma present a challenge for radiologists in actual clinical practice. The ability to distinguish HCCs from mimickers on initial imaging examinations is crucial for appropriate management and treatment decisions. Therefore, this pictorial review presents the imaging findings of atypical HCCs and HCCs mimicking malignant and benign lesions and discusses important clues that may help narrow down the differential diagnosis.

Multi-Detector CT Findings of Typical and Atypical Appendicitis: A Pictorial Essay (전형적 및 비전형적 충수염의 다중검출기컴퓨터단층촬영 소견: 임상화보)

  • Na Ri Yun;You Dong Won;Su Lim Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1047-1065
    • /
    • 2023
  • Multi-detector CT (MDCT) is a highly accurate diagnostic tool that is commonly used to evaluate appendicitis and its complications. The diagnosis of appendicitis based on MDCT findings can be difficult and challenging when the observed findings are inconsistent with the typical features. Atypical appendicitis includes a wide spectrum of features, such as variable positions of the appendix and cecum, complications, and unusual pathological findings of secondary appendicitis that mimic or induce appendicitis. Our pictorial essay describes the diverse spectrum of atypical appendicitis and appendicitis-like conditions in terms of location abnormalities, complications, and uncommon pathologies, including related tumors, reactive appendicitis, appendiceal diverticulitis, and IgG4-related disease. Through this essay, the readers can become more familiar with MDCT findings of atypical appendicitis.

The Necessity of Education in Response to Technological Advancements and Future Environmental Changes: A Comparison of Korean Medicine Doctors and Students

  • Yu Seong Park;Kyeong Heon Lee;Hye In Jeong;Kyeong Han Kim
    • The Journal of Korean Medicine
    • /
    • v.44 no.4
    • /
    • pp.72-86
    • /
    • 2023
  • Objectives: The medical field is rapidly evolving with AI and digital technologies like AI-based X-ray analysis and digital therapeutics gaining approval. Telemedicine is becoming prominent, and medical schools are adapting by integrating AI education. Pusan National University leads a talent training project for AI in health. Korean Medicine is incorporating AI with diagnostic systems and chatbots. However, there's a lack of research on education awareness in Korean Medicine Colleges. The study aims to assess opinions on integrating AI, digital therapeutics, and DNA test into the Korean medicine college curriculum for improved education. Methods: We selected appropriate four specific areas: artificial intelligence in medicine, digital therapeutics, DNA test, and telemedicine. The questionnaire developed for this study underwent expert evaluation and was subsequently administered to registered KMDs of the Association of Korean Medicine, as well as students from 12 Korean Medicine universities. The survey was designed to analyze the awareness and perceived importance of the 4 areas. Results: Both KMDs and Korean medicine students exhibited comparable awareness levels across the four objectives. Notably, both groups identified a high educational necessity and importance of artificial intelligence in medicine for clinical settings. Statistically significant differences were observed between KMDs and students in their perspectives on the importance of telemedicine and DNA test in the Korean medicine field, the educational necessity of DNA test within Korean medicine universities, and the need for comprehension of regulations related to digital therapeutics. Conclusion: The survey of Korean medicine professionals and students underscores a strong understanding of key areas such as Telemedicine, medical AI, DNA test, and digital therapeutics. Medical AI is identified as crucial for future education. There's a consensus on the need for curriculum changes in Korean medicine schools, particularly in adapting to evolving healthcare trends. The focus should be on practical clinical application, with a call for additional research to better integrate student and practitioner perspectives in future curriculum reform discussions.

The Characteristics of Bronchioloalveolar Carcinoma Presenting with Solitary Pulmonary Nodule (고립성 폐결절로 나타난 기관지폐포암의 임상적 고찰)

  • Kim, Ho-Cheol;Cheon, Eun-Mee;Suh, Gee-Young;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.;Han, Yong-Chol;Lee, Kyoung-Soo;Han, Jung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.280-289
    • /
    • 1997
  • Background : Bronchioloalveolar carcinoma (BAC) has been reported to diveres spectrum of chinical presentations and radiologic patterns. The three representative radiologic patterns are followings ; 1) a solitary nodule or mass, 2) a localized consolidation, and 3) multicentric or diffuse disease. While, the localized consolidation and solitary nodular patterns has favorable prognosis, the multicentric of diffuse pattern has worse prognosis regardless of treatment. BAC presenting as a solitary pulmonary nodule is often misdiagnosed as other benign disease such as tuberculoma. Therefore it is very important to make proper diagnosis of BAC with solitary nodular pattern, since this pattern of BAC is usually curable with a surgical resection. Methods : We reviewed the clinical and radiologic features of patients with pathologically-proven BAC with solitary nodular pattern from January 1995 to September 1996 at Samsung Medical Center. Results : Total 11 patients were identified. 6 were men and 5 were women. Age ranged from 37 to 69. Median age was 60. Most patients with BAC with solitary nodular pattern were asymptomatic and were detected by incidental radiologic abnormality. The chest radiograph showed poorly defined opacity or nodule and computed tomography showed consolidation, ground glass appearance, internal bubble-like lucencies, air bronchogram, open bronchus sign, spiculated margin or pleural tag in most patients. The initial diagnosis on chest X-ray were pulmonary tuberculosis in 4 patients, benign nodule in 2 patients and malignant nodule in 5 patients. The FDG-positron emission tomogram was performed in eight patients. The FDG-PET revealed suggestive findings of malignancy in only 3 patients. The pathologic diagnosis was obtained by transbronchial lung biopsy in 1 patient, by CT guided percutaneous needle aspiration in 2 patients, and by lung biopsy via video-assited thoracocopy in 8 patients. Lobectomy was performed in all patients and postoperative pathologic staging were $T_1N_0N_0$ in 8 patients and $T_2N_0M_0$ in 3 patients. Conclusion : Patients of BAC presenting with solitary nodular pattern were most often asymptomatic and incidentally detected by radiologic abnormality. The chest X-ray showed poorly defined nodule or opacity and these findings were often regarded as benign lesion. If poorly nodule or opacity does not disappear on follow up chest X-ray, computed tomography should be performed. If consolidation, ground glass appearance, open bronchus sign, air bronchogram, internal bubble like lucency, pleural tag or spiculated margin are found on computed tomography, further diagnostic procedures, including open thoracotomy, should be performed to exclude the possiblity of BAC with solitary nodular pattern.

  • PDF

The Study of Affecting Image Quality according to forward Scattering Dose used Additional Filter in Diagnostic Imaging System (부가필터 사용 시 전방 산란선량에 따른 화질 영향에 대한 연구)

  • Choi, Il-Hong;Kim, Kyo-Tae;Heo, Ye-Ji;Park, Hyong-Hu;Kang, Sang-Sik;Noh, Si-Cheol;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.597-602
    • /
    • 2016
  • Recent clinical field utilizes the aluminium filter in order to reduce the low-energy photons. However, the usage of the filter can cause adverse effect on the image quality because of the scattered dose that is generated by X-ray hardening phenomenon. Further, usage of filter with improper thickness can be a reason of dose creep phenomenon where unnecessary exposure is generated towards the patient. In this study, the author evaluated the RMS and the RSD analysis in order to have a quantitative evaluation for the effect of forward scattering dose by the filter on the image. as a result of the study, the FSR and the RSD was increased together with the increasing of thickness of the filter. In this study the RSD means the standard deviation of the mean value is relatively size. It can be understood that the signal-to-noise ratio decreases when the average value is taken as a signal and the standard deviation is judged as a noise. The signal-to-noise ratio can understanding as index of resolution at image. Based on these findings, it was quantitatively verified that there is a correlation of the image quality with the FSR by using an additional filter. The results, a 2.5 mmAl which is as recommended by NCRP in the tube voltage of 70 kVp or more showed the 14.6% on the RSD when the filter was not in used. these results are considered able to be utilized as basic data for the study about the filter to improve the quality of the image.

A Case of Childhood Obstructive Sleep Apnea Syndrome with Co-morbid Attention Deficit Hyperactivity Disorder Treated with Continuous Positive Airway Pressure Treatment (지속적(持續的) 상기도(上氣道) 양압술(陽壓術)을 시행(施行)하여 치료효과(治療效果)를 본 주의력(注意力) 결핍(缺乏).과잉(過剩) 운동장애(運動障碍)를 동반(同伴)한 소아기(小兒基) 폐쇄성(閉鎖性) 수면무호흡증(睡眠無呼吸症) 1례(例))

  • Sohn, Chang-Ho;Shin, Min-Sup;Hong, Kang-E;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.1
    • /
    • pp.85-95
    • /
    • 1996
  • Obstructive sleep apnea syndrome(OSAS) in childhood is unique and different n-om that in adulthood in several aspects, including pathophysiology, clinical features, diagnostic criteria, complications, management, and prognosis. Characteristic features of childhood OSAS in comparison with the adult form are the variety of severe complications such as developmental delay, more prominent behavioral and cognitive impairments, vivid cardiovascular symptoms, and increased death risk, warranting a special attention to the possible diagnosis of OSAS in children who snore. However, the childhood OSAS is often neglected and unrecognized. We, therefore, report a case of very severe OSAS in a 5-year-old boy who was sucessfully treated with continuous positive airway pressure(CPAP) treatment. Interestingly, the patient was comor-bid with the attention deficit hyperactivity disorder. Prior to the initial visit to us, adenotonsillectomy had been done at the age of 4 with no significant improvement of apneic symptoms and heavy snoring. On the initial diagnostic procedures, marked degree of snoring was audible even in the daytime wake state and the patient was observed to be very hyperactive. Increased pulmonary vascularity with borderline cardiomegaly was noted on chest X-ray. The baseline polysomnography revealed that the patient was very sleep-apneic and snored very heavily, with the respiratory disturbance index(RDI) of 46.9 per hour of sleep, the mean SaO2 of 78.8%, and the lowest SaO2 of 40.0%(the lowest detectable oxygen level by the applied oxymeter). The second night polysomnography was done for CPAP titration and the optimal pressure turned out to be $8.0\;cmH_2O$. The applied CPAP treatment was well tolerated by the patient and was found to be very effective in alleviating heavy snoring and severe repetitive sleep apneas. After 18 months of the CPAP treatment, the patient was followed up with nocturnal polysomnography(baseline and CPAP nights) and clinical examination. Sleep apneas were still present without CPAP on the baseline night. However, the severity of OSAS was significantly decreased(RDI of 15.7, mean SaO2 of 96.2%, and the lowest SaO2 of 83.0%), compared to the initial polysomnographic findings before initiation of long-term CPAP treatment. Wechsler intelligence tests done before and after the CPAP treatment were compared with each other and surprising improvement of intelligence(total 9 points, performance 16 points) was noted. Clinically he was found to be markedly improved in his attention deficit hyperactive behavior after CPAP treatment, but with minimal change of TOVA(test of variables of attention) scores except conversion of reaction time score into normal range. On the chest X-ray taken after 18 months of CPAP application, the initial cardiopulmonary abnormalities were not found at all. We found that the CPAP treatment in a young child is very effective, safe, and well-tolerated and also improves the co-morbid attention deficit hyperactive symptoms. Overall, the growth and development of the child has been facilitated with the long-term use of CPAP. Cardiovascular complications induced by OSAS have been also normalized with CPAP treatment. We suggest that early diagnosis and active treatment intervention of OSAS in children are crucial in preventing and ameliorating possible serious complications caused by repetitive sleep apneas and consequent hypoxic damage during sleep.

  • PDF