• Title/Summary/Keyword: Diagnostic X-ray

Search Result 600, Processing Time 0.023 seconds

Acceptance Test and Quality Control of Radiotherapy Treatment Simulator (의료용 모의치료기의 품질관리에 관한 연구)

  • 신동호;박성용;신동오;최진호;김유현;권수일
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.90-97
    • /
    • 2002
  • The simulator which has a identical geometry with radiotherapy equipments, is a essential equipment to accomplish optimized radiotherapy plan through simulation by using diagnostic low energy X-ray. A Radiotherapy simulator has a combined technology from the therapeutic and diagnostic radiology and needs a periodical test for mechanical and optical properties, X-ray generator, image intensifier of simulator to keep the proper maintenance and radiation safety. Hence, tests were done and classified as i) mechanical and optical parameter for the gantry, collimator, and couch ii) key performance of the X-ray generator such as a kVp, mAs, and timer iii) performance of the image intensifier such as a resolution and contrast for three kinds of simulator, common use in clinic. The above result of tests will be applied to the acceptance test and periodical quality assurance procedure.

  • PDF

Development of High Voltage Generator for Diagnostic X-ray Equipment (진단용 X선 기기의 고전압 발생장치 개발)

  • Kim, Young-Pyo;Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.764-765
    • /
    • 2010
  • The medical treatment X-ray machineries used in diagnosis of the human body is possible to diagnosis inside of the human body with the method of noninvasive so that it has shared a very important role in diagnosis from the medical institution. High voltage occurrence system which is most important in occurrence of X-ray has mainly been used the existing type of high voltage transformer, however it has a low efficiency of X-ray occurrence since it is a big and heavy, and a high ripple ratio of the direct current high voltage come to the X-ray tube. In order to solve this problem, the research has been advanced about the high voltage power supply system, and the inverter type of the high voltage occurrence system which occurs a high voltage by increasing the power frequency from about ten times to about hundred times with the inverter has currently used mainly. Also, the operation of tube voltage and tube current was controlled by using PWM method and the operation results were identified using an oscilloscope.

  • PDF

Multispectral X-ray imaging to distinguish among dental materials

  • Peter, Ann-Christin;Schnaubelt, Matthias;Gente, Michael
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.247-254
    • /
    • 2017
  • Purpose: Dual-energy X-ray imaging is widely used today in various areas of medicine and in other applications. However, no similar technique exists for dental applications. In this study, we propose a dual-energy technique for dental diagnoses based on voltage-switching. Materials and Methods: The method presented in this study allowed different groups of materials to be classified based on atomic number, thereby enabling two-dimensional images to be colorized. Computer simulations showed the feasibility of this approach. Using a number of different samples with typical biologic and synthetic dental materials, the technique was applied to radiographs acquired with a commercially available dental X-ray unit. Results: This technique provided a novel visual representation of the intraoral environment in three colors, and is of diagnostic value when compared to state-of-the-art grayscale images, since the oral cavity often contains multiple permanent foreign materials. Conclusion: This work developed a technique for two-dimensional dual-energy imaging in the context of dental applications and showed its feasibility with a commercial dental X-ray unit in simulation and experimental studies.

Development of Children's X-ray Imaging Assist Device (어린이 방사선검사 보조기구의 개발)

  • Rhee, Do-Byung;Seo, Seung-Jun;Choi, Hyun-Woo;Ko, Cheol-Woo;Kim, Jong-Ki
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.243-249
    • /
    • 2020
  • Examination with medical radiography is the most significant advances in medicine in the 21st century. Diagnostic imaging occupies an important position in all medical subjects, surgical and internal medicine, including radiology, orthopedics, and neurosurgery. However, the invention associated with conventional radiography devices has focused only on emphasizing the efficient aspects of the examination or obtaining clearer images without considering the age and disease-induced constraints of the patient's posture. The newly developed X-ray aids to solve this problem can effectively perform X-ray imaging of children's who have difficulty communicating and controlling. It is also thought to be a good way to provide accurate imaging information and minimize radiation exposure for children.

The Effects of Total Variation (TV) Technique for Noise Reduction in Radio-Magnetic X-ray Image: Quantitative Study

  • Seo, Kanghyen;Kim, Seung Hun;Kang, Seong Hyeon;Park, Jongwoon;Lee, Chang Lae;Lee, Youngjin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.593-598
    • /
    • 2016
  • In order to reduce the amount of noise component in X-ray imaging system, various reduction techniques were frequently used in the field of diagnostic imaging. Although the previous techniques -such as median, Wiener filters and Anscombe noise reduction technique - were able to reduce the noise, the edge information was still damaged. In order to cope with this problem, total variation (TV) noise reduction technique has been developed and researched. The purpose of this study was to evaluate and compare the image quality using normalized noise power spectrum (NNPS) and contrast-to-noise ratio (CNR) through simulations and experiments with respect to the above-mentioned noise reduction techniques. As a result, not only lowest NNPS value but also highest CNR values were acquired using a TV noise reduction technique. In conclusion, the results demonstrated that TV noise reduction technique is proved as the most practical method to ensure accurate denoising in X-ray imaging system.

A comparative study on keypoint detection for developmental dysplasia of hip diagnosis using deep learning models in X-ray and ultrasound images (X-ray 및 초음파 영상을 활용한 고관절 이형성증 진단을 위한 특징점 검출 딥러닝 모델 비교 연구)

  • Sung-Hyun Kim;Kyungsu Lee;Si-Wook Lee;Jin Ho Chang;Jae Youn Hwang;Jihun Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.460-468
    • /
    • 2023
  • Developmental Dysplasia of the Hip (DDH) is a pathological condition commonly occurring during the growth phase of infants. It acts as one of the factors that can disrupt an infant's growth and trigger potential complications. Therefore, it is critically important to detect and treat this condition early. The traditional diagnostic methods for DDH involve palpation techniques and diagnosis methods based on the detection of keypoints in the hip joint using X-ray or ultrasound imaging. However, there exist limitations in objectivity and productivity during keypoint detection in the hip joint. This study proposes a deep learning model-based keypoint detection method using X-ray and ultrasound imaging and analyzes the performance of keypoint detection using various deep learning models. Additionally, the study introduces and evaluates various data augmentation techniques to compensate the lack of medical data. This research demonstrated the highest keypoint detection performance when applying the residual network 152 (ResNet152) model with simple & complex augmentation techniques, with average Object Keypoint Similarity (OKS) of approximately 95.33 % and 81.21 % in X-ray and ultrasound images, respectively. These results demonstrate that the application of deep learning models to ultrasound and X-ray images to detect the keypoints in the hip joint could enhance the objectivity and productivity in DDH diagnosis.

Calculation Method of Entrance Skin Dose in X-ray Beam Quality Factor (선질계수에 의한 피부입사선량 계산법)

  • Kim, Sung-Chul;Kim, Chong-Yeal;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.258-267
    • /
    • 2010
  • This interest in radiation exposure makes increasing doctor's awareness and knowledge of radiation dose in patients during X-ray test important in reducing patient's uneasiness. However, very few facilities are equipped with measurement instruments. Therefore, an intensive study to find out patient dose using computational method has been initiated. This study used special features of the bit system and NDD-M and directly measured the output dose of diagnostic X-ray instruments used in Korea to create tables. Two different methods were found to be adequate when applied to cases when X-ray outputs were both known and unknown, and comparative experiments with real measurement doses were carried out. Presented methods were found to provide more accurate results compared to the bit system and NDD-M. Therefore, patient dose during clinical trials were found to be more easily acceptable to medical personnel in the radiation field in terms of radiation exposure and reduction of medical X ray dose.

A Case report of Idiopathic Scoliosis Patient : Comparison of X-ray and Digital Infrared Thermographic Imaging (특발성 척추측만증 환자의 X-ray와 적외선 체열촬영의 비교 1례)

  • Jo, Jun-Young;Kim, Jin-Woo;Park, Kyoung-Sun;Lee, Jin-Moo
    • Journal of Oriental Medical Thermology
    • /
    • v.9 no.1
    • /
    • pp.51-56
    • /
    • 2011
  • Purpose : The purpose of this study is to report the comparison of X-ray and Digital Infrared Thermographic Imaging (DITI) of a patient with idiopathic scoliosis. Method: The patient in this case was a 25-year-old female. Her chief complaint was a pain in lumbar, scapular and shoulder regions. We examined her with DITI and X-ray. And then We compared DITI and X-ray. Results: Cobb's angle of thoracic spine was $24.78^{\circ}$ as a primary curve. Cobb's angle of thoracolumbar spine was $17.63^{\circ}$. Temperature on convex side of the thoracic spine was $0.3^{\circ}C$ higher than the other side. Temperature on convex side of cervical spine was $1.4^{\circ}C$ higher than the other side. There was no correlation curvature degree with temperature difference. Conclusion : There was a tendency that the temperature on convex side of the spine is higher than the other side of the spine. DITI is a useful assessment tool when it is used with X-ray as a diagnostic tool of idiopathic scoliosis. Further studies are needed.

  • PDF

A research on remote X-ray detector design development for marketing in field diagnosis service (현장 진단 서비스 시장 공략을 위한 '무선 X-ray 디텍터' 디자인개발에 관한 연구)

  • Song, Seong Il
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.4
    • /
    • pp.196-205
    • /
    • 2017
  • In recent years, the service design in the medical sector evolves through practical service research and development that can visualize both intangible and intangible service elements in an integrative way and derive innovative solutions to help customers feel the service more important value. With the improvement of personal income, interest in medical welfare and well-being is increasing day by day, and the focus of the medical sector shifts from the concept of treatment of diseases and illness to preventive medicine. In response to this trend, research and development of home health care system, which greatly reduces the time and space constraint of health checkup and health care by combining ubiquitous concept with medical welfare, are being actively conducted, and the needs for improving products and medical environment based on user-centered medical service and user needs in accordance with the Health Care 3.0 Era, it becomes necessary to develop on-site medical diagnostic products that reflect user-centered needs and needs. This study is intended to research and develop a product that sufficiently reflects the needs of users by applying suitable materials and shape for on-site diagnostic product in researching and developing Wireless X-ray Detector.

An Automatic Extraction of the Lung Region in X- Rays (흉부방사선 영상의 흉부영역 자동검출에 관한 연구)

  • 김용만;장국현
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.331-342
    • /
    • 1989
  • This paper presents a new algorithm that extracts lung region in X-Rays and enhance.j the region. Comparing to prior algorithms that enhance whole X-Ray image, this algorithm leads more effective results. For this algorithm extracts lung region first, and enhances the lung region excluding parameters of other region. For choosing optimal threshold, we compare OTSU's mothod with the proposed method. We obtain lung boundary using contour following algorithm and Rray level searching method in gray level rescaled image. We Process histogram equalization in lung region and obtain enhanced lung image. By using the proposed algorithm, we obtain lung region effectively in chest X-Ray that need in medical image diagnostic system.

  • PDF