• 제목/요약/키워드: Diagnostic Equipment

검색결과 374건 처리시간 0.023초

한방 의료기관의 의료기기 보유현황 및 한방의료기기의 문제점과 개선방안에 대한 조사 연구 (Survey of Traditional Korean Medical Device : Number of devices, Problems, Solution Plan)

  • 김지혜;김재욱;김근호
    • 동의생리병리학회지
    • /
    • 제28권4호
    • /
    • pp.430-439
    • /
    • 2014
  • This study was performed to assess the perception and needs of the traditional Korean Medical Equipment (KME) in clinic. We conducted survey research among 15,550 traditional Korean medical doctors (KMD) responded to e-mail during 2 weeks. 899 participants the survey, consisting of questions regarding 'number of devices of the KME' and 'solution and improvement plan of the KME'. The participants were asked to choose their ranking of problems of the KME and also put a check mark in the column that the reasons for this choice. As results, final scores in priority ranking medical devices were derived in 7 categories. Physical therapy equipment and acupuncture treatment devices were included in high ranks. 42.8 % of the participants responded that the diagnostic medical devices seemed important in clinics and 67.4 % of the participants indicated that the therapeutic medical devices seemed to important in clinics. The identified problems of KME were 'low reproducibility and reliability of a diagnosis result (24.8%)' and 'uncertain validity of a diagnostic medical devices (20.5%)'. The improvement plan of the problems were 'to establish the law for using the medical devices (26.6%)' and 'evaluation of validity of the KME (26.2%)'. A survey of KMD revealed the condition of KME's number of devices and the solution plan for the problem of several KMEs. Understanding the needs of KMD could probably contribute to the research and development of KMEs in the future.

환자 안전을 위한 특수의료장비의 검사자 실명제 자동 표식 등록 개발 연구 (Automatic real-name registration mark examiner research and development of special medical equipment for patient safety)

  • 유세종;박종배;김정호;김기진;임재동
    • 대한안전경영과학회지
    • /
    • 제17권2호
    • /
    • pp.147-152
    • /
    • 2015
  • Through the inspector's real name to improve the quality of inspection is to show the design Radiological examination pursuant to the Ordinance of the Ministry of Health and Welfare for patient safety in the Image. However, the use of existing and in EMR, equipment within the handwriting input, the individual initial use has a problem. In this study, increasing the stability of the patient and the precise inspection, In order to increase the efficiency and convenience than the real-name system for quality control inspectors of medical equipment, Using the EMR and PACS developed and applied to evaluate the usefulness of automatic enrollment. Enter your information in the EMR, which was developed markers that inspectors use to compare the before and after images PACS satisfaction. Convenience than using traditional, consistency, the entry of the missing were higher as a statistically significant difference. A test strip automatic enrollment programs are developed in this study. You can increase the stability of the patient by checking the image to show the real tester, we expect the quality of care would be improved.

진단용 X선장치의 성능 실태 조사연구 (A Study on the Test of Efficiency of the Diagnostic X-ray Equipment according to Their Rectifications)

  • 선종률
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.44-48
    • /
    • 1997
  • For the efficient management of the diagnostic x-ray equipment, a nation-wide inspection of hospitals was performed by an inspection institute in Taejon in the first half of 1997. Among those hospitals inspected, 28 equipments(machines) which were over 500 mA were randomly selected according to their characteristics : 7 condenser type x-ray equipments, 7 three control phase of full wave rectification of type remote control x-ray equipments, 7 single phase of full wave rectification type for general radiography equipments, and 7 single phase of full wave rectification type of R/F equipments. We obtained the following results by conducting the experiment based on the efficiency of the equipments mentioned above. 1) When the equipments are analyzed, 2 out of 7 single phase of full wave rectification type of general radiography equipments(28.6%), 3 out of 7 single phase of full wave rectification type of R/F equipments(42.9%), 5 out of 7 three phase of full wave rectification type remote of control x-ray equipments(71.4%), and 4 out of 7 condenser type of x-ray equipments(57.1%) showed suitability. It proves the superiority of the three phase of full wave rectification type of remote control x-ray equipments. 2) From the overall analysis, only about 50% of the equipments(suitability of 14 out of 28) maintain the efficient management. Therefore, maintenance management of equipments is more necessary. If the efficiency of the x-ray equipment is uniformly maintained and managed to prevent the breakdown(trouble) beforehand especially through the continuous inspection of tube voltage, tube current, exposure time, and collimator, the financial loss and exposure dose to the patient, as well as the workers engaged in radiation, can be reduced for better medical service.

  • PDF

간이형 상시 GIS 진단장치 (Simplified GIS Diagnostic SYSTEM)

  • 정재기;최윤종;강창익;장훈기;곽희섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.74-77
    • /
    • 2006
  • This research is focused on the development of GIS Diagnostic SYSTEM to prevent accidents beforehand by inspecting the internal defects of GIS (Gas Insulated Switchgear) which is a main power-facility for substations. GIS Diagnostic SYSTEM is categorized as 'Real time on-line test type' and 'Portable test type' depending on the types of testing, it uses PD(partial discharge) which mostly incurs in GIS internal defects, to inspect. As of now, mostly foreign equipments are imported for use due to the lack of the technology localization, and these are installed and operated on only some parts of highly-graded GIS power-facilities such as in 76skv or 345kv for its being expensive. Furthermore, other than foreign equipments being costly, it also has a weak point of very long unavailability in case of Diagnostic system break-down while using, because it takes a comparatively long period of corrective maintenance precesses. We have localized to develop personal real-time multi -functional GIS Diagnostic system which can test on all GIS power-facility comprehensively and economically therefore overcome all these problems mentioned above, a market expansion is expected from the decrease of price and replacing the import equipments in the future. As the equipment was developed to be Personal for the simple ways of installing and utilizing, it can be operated without any complex cable installation like other existing GIS Diagnostic system requires, therefore also decrease the cost of cable installation.

  • PDF

High-accuracy quantitative principle of a new compact digital PCR equipment: Lab On An Array

  • Lee, Haeun;Lee, Cherl-Joon;Kim, Dong Hee;Cho, Chun-Sung;Shin, Wonseok;Han, Kyudong
    • Genomics & Informatics
    • /
    • 제19권3호
    • /
    • pp.34.1-34.6
    • /
    • 2021
  • Digital PCR (dPCR) is the third-generation PCR that enables real-time absolute quantification without reference materials. Recently, global diagnosis companies have developed new dPCR equipment. In line with the development, the Lab On An Array (LOAA) dPCR analyzer (Optolane) was launched last year. The LOAA dPCR is a semiconductor chip-based separation PCR type equipment. The LOAA dPCR includes Micro Electro Mechanical System that can be injected by partitioning the target gene into 56 to 20,000 wells. The amount of target gene per wells is digitized to 0 or 1 as the number of well gradually increases to 20,000 wells because its principle follows Poisson distribution, which allows the LOAA dPCR to perform precise absolute quantification. LOAA determined region of interest first prior to dPCR operation. To exclude invalid wells for the quantification, the LOAA dPCR has applied various filtering methods using brightness, slope, baseline, and noise filters. As the coronavirus disease 2019 has now spread around the world, needs for diagnostic equipment of point of care testing (POCT) are increasing. The LOAA dPCR is expected to be suitable for POCT diagnosis due to its compact size and high accuracy. Here, we describe the quantitative principle of the LOAA dPCR and suggest that it can be applied to various fields.

고신뢰성 USN 응용 서비스 지원을 위한 오작동 진단 상황인지 미들웨어 구현 (Implementation of Failure-Diagnostic Context-awareness Middleware for Support Highly Reliable USN Application Service)

  • 이용웅;김세한;손교훈;이인환;신창선
    • 인터넷정보학회논문지
    • /
    • 제12권3호
    • /
    • pp.1-16
    • /
    • 2011
  • 본 논문에서는 실내에 센서 네트워크가 적용된 USN 응용 시스템에서 발생하는 센서나 설비 장치의 오작동을 진단하여, 해당 시스템이 제공하는 서비스의 신뢰성을 높여주는 오작동 진단 상황인지 미들웨어를 제안한다. 본 논문에서 새롭게 제안하는 미들웨어는 데이터관리 모듈, 상황정보제공 모듈, 상황분석 모듈, 서비스제공 모듈, 정보저장소 모듈로 구성되며, 모듈간의 상호작용으로 얻은 데이터는 오작동 진단 알고리즘을 통해 비교 분석함으로써, 센서나 설비 장치의 오작동 여부를 판단한다. 구현된 미들웨어는 시뮬레이션을 통해 수행성을 검증하였다. 그 결과 다수의 센서가 설치된 대형 시스템에서 본 미들웨어가 높은 성능을 발휘한다는 것을 확인할 수 있었다.

MOTOR CONTROL CENTER (MCC) BASED TECHNOLOGY STUDY FOR SAFETY-RELATED MOTOR OPERATED VALVES

  • Kang, Shin-Cheul;Park, Sung-Keun;Lee, Do-Hwan;Kim, Yang-Seok
    • Nuclear Engineering and Technology
    • /
    • 제38권2호
    • /
    • pp.155-162
    • /
    • 2006
  • It is necessary to monitor periodically the operability of safety-related motor-operated valves (MOVs) in nuclear power plants. However, acquiring diagnostic signals for MOVs is very difficult, and doing so requires an excessive amount of time, effort, and expenditure. This paper introduces an accurate and economical method to evaluate the performance of MOVs remotely. The technique to be utilized includes electrical measurements and signal processing to estimate the motor torque and the stem thrust, which have been cited as the two most effective parameters in diagnosing MOVs by the US Nuclear Regulatory Commission. The motor torque is calculated by using electrical signals, which can be measured in the motor control center (MCC). Some advantages of using the motor torque signature over other signatures are examined. The stem thrust is calculated considering the characteristics of the MOV and the estimated motor torque. The basic principle of estimating stem thrust is explained. The developed method is implemented in diagnostic equipment, namely, the Motor Operated Valve Intelligent Diagnostic System (MOVIDS), which is used to obtain the accuracy of and to validate the applicability of the developed method in nuclear power plants. Finally, the accuracy of the developed method is presented and some examples applied to field data are discussed.

입력전원의 변화에 따른 X선 기기의 특성평가 (Characteristic of X-ray Equipment according to the Input Power Condition)

  • 김영표;김태곤;천민우;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.773-775
    • /
    • 2010
  • 의료용 X-선 고전압발생장치는 작동 시 높은 용량의 입력전원이 필요하며, 만약 전원환경이 적합하지 않을 경우 X-선 고전압발생장치를 사용하지 못하거나 불안정한 작동으로 인해 원활한 작동이 불가능해 진다. 전원환경에 따라 제품이 불안정 할 경우 환자 진료에 지장이 생길 수 있는 것을 감안하여 상용전원을 사용하지 않고 의료용 X-선 고전압발생장치를 작동 할 수 있는 전원장치를 배터리를 활용하도록 하였다. 전원회로를 설계한 후 시제품을 제작하여 본 논문에 제시된 방법에 따라 상용전원과 배터리 전원을 각각 비교하여 의료용 X-선 고전압발생장치가 입력전원방식에 따라 어떤 특성과 효율을 가지고 있는지 확인하였다.

  • PDF

Implementation of point-of-care platforms for rapid detection of porcine circovirus type 2

  • Chiao-Hsu Ke;Mao-Yuan Du;Wang-Ju Hsieh;Chiu-Chiao Lin;James Mingjuh Ting;Ming-Tang Chiou;Chao-Nan Lin
    • Journal of Veterinary Science
    • /
    • 제25권2호
    • /
    • pp.28.1-28.11
    • /
    • 2024
  • Background: Porcine circovirus type 2 (PCV2) infection is ubiquitous around the world. Diagnosis of the porcine circovirus-associated disease requires clinic-pathological elements together with the quantification of viral loads. Furthermore, given pig farms in regions lacking access to sufficient laboratory equipment, developing diagnostic devices with high accuracy, accessibility, and affordability is a necessity. Objectives: This study aims to investigate two newly developed diagnostic tools that may satisfy these criteria. Methods: We collected 250 specimens, including 170 PCV2-positive and 80 PCV2-negative samples. The standard diagnosis and cycle threshold (Ct) values were determined by quantitative polymerase chain reaction (qPCR). Then, two point-of-care (POC) diagnostic platforms, convective polymerase chain reaction (cPCR, qualitative assay: positive or negative results are shown) and EZtargex (quantitative assay: Ct values are shown), were examined and analyzed. Results: The sensitivity and specificity of cPCR were 88.23% and 100%, respectively; the sensitivity and specificity of EZtargex were 87.65% and 100%, respectively. These assays also showed excellent concordance compared with the qPCR assay (κ = 0.828 for cPCR and κ = 0.820 for EZtargex). The statistical analysis showed a great diagnostic power of the EZtargex assay to discriminate between samples with different levels of positivity. Conclusions: The two point-of-care diagnostic platforms are accurate, rapid, convenient and require little training for PCV2 diagnosis. These POC platforms can discriminate viral loads to predict the clinical status of the animals. The current study provided evidence that these diagnostics were applicable with high sensitivity and specificity in the diagnosis of PCV2 infection in the field.

SIL 인증을 위한 FMEDA 프로세스 연구 : 화염검출기 사례를 중심으로 (A Study on FMEDA Process for SIL Certification : A Case Study of a Flame Scanner)

  • 김성규;김용수
    • 산업공학
    • /
    • 제25권4호
    • /
    • pp.422-430
    • /
    • 2012
  • In this article, we introduced the estimation method by 'Safety Integrity Level'(SIL) for the criterion of safety assurance and performed a case study on a flame scanner. SIL requires probabilistic evaluation of each set of equipment used to reduce risk in a safety related system. FMEDA(Failure Modes, Effects and Diagnostic Analysis) method is widely used to evaluate the safety levels and provides information on the failure rates and failure mode distributions necessary to calculate a diagnostic coverage factor for a part or a component. Basically, two parameters resulting from FMEDA are used for SIL classification of the device : SFF(Safe Failure Fraction) and PFD(Probability of Failure on Demand). In this case study, it is concluded that the flame scanner is designed to fulfill the condition of SIL 3 in the aspect of SFF and PFD.