• Title/Summary/Keyword: Device to Device (D2D)

Search Result 1,734, Processing Time 0.032 seconds

Development of a Garlic Clove Planter Attached to Power Tiller (경운기 부착형 점파식 마늘파종기 개발)

  • Choi, D.K.;Park, S.H.;Kang, T.G.;Kwak, T.Y.;Lee, C.S.;Cho, S.C.;Kim, Y.J.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.3
    • /
    • pp.140-146
    • /
    • 2009
  • The garlic, along with the red pepper, is one of the major seasoning vegetables in Korea. Garlic clove planting is one of the most laborious operations. Labor cost is the main source of high production cost of the garlic. Because of the geometrical uniqueness and irregularity of garlic cloves, mechanization of garlic clove planting is very difficult. To overcome price competition against the imported garlic, however, there has been a need of development of a clove metering device and a planting device for the garlic clove planter. Computer simulation, laboratory tests and field tests were conducted to develop a garlic clove planter. This research was conducted to drop garlic cloves into a soil holes through a drum bucket metering system and a rotary type planting system. Followings are the major achievements from this study. 1. The metering device consisted of a drum, a guide, a bucket and a bucket cover. Opening positions of the metering hopper were evaluated at different positions and trajectories of planting hoppers. The simulation showed that the optimum positions of hopper was -15${\sim}$0 mm in the x direction. 2. When the planter was tested under different soil textures and water contents, the best performances were obtained in a upland field with 29.1% water content and a paddy field with 18.3% water content where single clove metering and missing rate were 88.4% and 1.3%, and 90.7% and 2.0%, respectively.

Design of Corase Flash Converter Using Floating Gate MOSFET (부유게이트를 이용한 코어스 플레쉬 변환기 설계)

  • Chae, Yong-Ung;Im, Sin-Il;Lee, Bong-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.5
    • /
    • pp.367-373
    • /
    • 2001
  • A programmable A/D converter is designed with 8 N and P channel MOSFETs, respectively. In order to observe linear programmability of the EEPROM device during programming mode, a cell is developed with a 1.2 ${\mu}{\textrm}{m}$ double poly CMOS fabrication process in MOSIS. It is observed that the high resolution, of say 10m Volt, is valid in the range 1.25volts to 2volts. The experimental result is used for simulating the programmable 8 bit A/D converter with Hspice. The A/D converter is demonstrated to consume low power, 37㎽ by utilizing a programming operation. In addition, the converter is attained at the conversion frequency of 333 MHz.

  • PDF

A Study on Tensile Strength of the 3D Printing Product According to the Nitrogen Concentration of Chamber Inside (챔버 내부의 질소 농도에 따른 3D프린팅 출력물의 인장 강도에 관한 연구)

  • Lee, Song Yeon;Huh, Yong Jeong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.103-107
    • /
    • 2022
  • Scaffolds are the structures that safely protect sensors in various parts of the body. Because of scaffolds must protect sensors from load, the tensile strength of the scaffolds must be higher than 750 kgf/cm2. Currently, the tensile strength of scaffolds made with the 3d printer is 714 kgf/cm2. We confirm that the tensile strength of the scaffolds increase using air with high nitrogen concentration. In this study, we conducted experiments to find nitrogen concentrations in which the tensile strength of the specimen is higher than 750 kgf/cm2. The nitrogen control device and the nitrogen concentration sensor were installed in the chamber type 3d printer. The nitrogen concentration inside the 3d printer was changed by 5 % from 80 % to 100 %. Specimens of ASTM D 638 standard were produced under changed nitrogen concentration. We measured the tensile strength of specimens. We compared the tensile strength of specimens produced under each nitrogen concentration. We confirmed that when air with nitrogen concentration of 90 % was used, the tensile strength of scaffolds were 762 kgf/cm2.

A design of a floating point unit with 3 stages for a 3D graphics shader engine

  • Lee, Kwang-Yeob
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.358-363
    • /
    • 2007
  • This paper presents a floating point unit(FPU) with 3 stages for a 3D graphics shader engine. It targeted to accelerate 3D graphics in portable device environments. In order to design a balanced architecture for a shader engine, we analyzed shader assembly instructions and estimated the performance of FPU with the method we propose. The proposed unit handles 4-dimensional data through separated two paths that are lead to general operation module and special function module. The proposed FPU is compiled as a form of the cascade FPU with 3 stages to efficiently handle a matrix operation with relatively low hardware overhead. Except some complex instructions that are executed using macro instructions, all instructions complete an operation in a single instruction cycle at 100MHz frequency. A special function module performs all operations in a single clock cycle using the Newton Raphson method with the look-up table.

  • PDF

Development of large-capacity stack mold for the high-performance household case (고기능성 생활용기 성형을 위한 대용량 스택금형 개발)

  • Shin, Jang-Soon;Kim, Eu-Jin;Jung, Gui-Jae;Hwang, Soon-Hwan;Heo, Young-Moo;Yoon, Gil-Sang;Jung, Woo-Chul;Seo, Tae-Il
    • Design & Manufacturing
    • /
    • v.2 no.3
    • /
    • pp.28-31
    • /
    • 2008
  • In recent, the demand of high-productivity injection mold is increased because of the growth of international packaging market which is induced by an increase of population. The increase of productivity leads to the large-capacity injection molding machine and peripheral devices. For solving this problem, the stack mold which is based on the exsiting machine and device has researched in advanced countries actively. In this paper, as the preliminary research of stack mold development, the stack mold which has 2 level ${\times}4$ cavity was designed and fabricated. Besides, the motion and structural analysis were performed to verify the stability of developed stack mold.

  • PDF

Microencapsulation of Lactobacillus plantarum DKL 109 using External Ionic Gelation Method

  • Chun, Honam;Kim, Cheol-Hyun;Cho, Young-Hee
    • Food Science of Animal Resources
    • /
    • v.34 no.5
    • /
    • pp.692-699
    • /
    • 2014
  • The aim of this study was to apply the external ionic gelation using an atomizing spray device comprised of a spray gun to improve the viability of Lactobacillus plantarum DKL 109 and for its commercial use. Three coating material formulas were used to microencapsulate L. plantarum DKL 109: 2% alginate (Al), 1% alginate/1% gellan gum (Al-GG), and 1.5% alginate/3% gum arabic (Al-GA). Particle size of microcapsules was ranged from 18.2 to $23.01{\mu}m$ depending on the coating materials. Al-GA microcapsules showed the highest microencapsulation yield (98.11%) and resulted in a significant increase in survivability of probiotic in a high acid and bile environment. Encapsulation also improved the storage stability of cells. The viability of encapsulated cells remained constant after 1-mon storage at ambient temperature. The external ionic gelation method using an atomizing spray device and the Al-GA seems to be an efficient encapsulation technology for protecting probiotics in terms of scale-up potential and small microcapsule size.

An Experimental Study on Shielding Apparatus for the Impulse Noise of K2 Rifle (K2소총의 사격음 차폐장치에 관한 실험적 연구)

  • Lee, Jin-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.486-492
    • /
    • 2010
  • This paper studies an experimental analysis of the impulse noise of K2 rifle when its bullet passes through the large tube(length 1.84m, outer diameter 50cm, glass wool & steel). In experiment, the characteristics of the sound of shooting were different according to the way of shooting; the results of the experiment are given below. First of all, the shooting sound was lower in single-shot shooting, when compared to 3rds burst-shot shooting, difference averaging 2.8dB, 4.0dB at maximum. In short, the difference is minuscule. Secondly, the sound of the K2 rifle was diminished when shot in a tube, ranging from 2.7dB to 15.4dB, averaging 8.2dB. Thirdly, the shooting sound of the K2 rifle was diminished as the insertion depth deepened with formulas given in Fig. 5, 6. Fourthly, basic data for excluding sound of the shooting were presented. Lastly, the characteristics of the shooting sound could be equally used as a basic material for developing marksmanship and sharp-shooting detection device.

Dedicated preparation for in situ transmission electron microscope tensile testing of exfoliated graphene

  • Kim, Kangsik;Yoon, Jong Chan;Kim, Jaemin;Kim, Jung Hwa;Lee, Suk Woo;Yoon, Aram;Lee, Zonghoon
    • Applied Microscopy
    • /
    • v.49
    • /
    • pp.3.1-3.7
    • /
    • 2019
  • Graphene, which is one of the most promising materials for its state-of-the-art applications, has received extensive attention because of its superior mechanical properties. However, there is little experimental evidence related to the mechanical properties of graphene at the atomic level because of the challenges associated with transferring atomically-thin two-dimensional (2D) materials onto microelectromechanical systems (MEMS) devices. In this study, we show successful dry transfer with a gel material of a stable, clean, and free-standing exfoliated graphene film onto a push-to-pull (PTP) device, which is a MEMS device used for uniaxial tensile testing in in situ transmission electron microscopy (TEM). Through the results of optical microscopy, Raman spectroscopy, and TEM, we demonstrate high quality exfoliated graphene on the PTP device. Finally, the stress-strain results corresponding to propagating cracks in folded graphene were simultaneously obtained during the tensile tests in TEM. The zigzag and armchair edges of graphene confirmed that the fracture occurred in association with the hexagonal lattice structure of graphene while the tensile testing. In the wake of the results, we envision the dedicated preparation and in situ TEM tensile experiments advance the understanding of the relationship between the mechanical properties and structural characteristics of 2D materials.

Structure Modeling of 100 V Class Super-junction Trench MOSFET with Specific Low On-resistance

  • Lho, Young Hwan
    • Journal of IKEEE
    • /
    • v.17 no.2
    • /
    • pp.129-134
    • /
    • 2013
  • For the conventional power metal-oxide semiconductor field-effect transistor (MOSFET) device structure, there exists a tradeoff relationship between specific on-resistance ($R_{ON.SP}$) and breakdown voltage ($V_{BR}$). In order to overcome the tradeoff relationship, a uniform super-junction (SJ) trench metal-oxide semiconductor field-effect transistor (TMOSFET) structure is studied and designed. The structure modeling considering doping concentrations is performed, and the distributions at breakdown voltages and the electric fields in a SJ TMOSFET are analyzed. The simulations are successfully optimized by the using of the SILVACO TCAD 2D device simulator, Atlas. In this paper, the specific on-resistance of the SJ TMOSFET is successfully obtained 0.96 $m{\Omega}{\cdot}cm^2$, which is of lesser value than the required one of 1.2 $m{\Omega}{\cdot}cm^2$ at the class of 100 V and 100 A for BLDC motor.

Development of a Noncontact Three Dimensional Foot Form Measurement System with Optical Triangulation (광삼각법을 이용한 비접촉 3차원 족형 측정 시스템 설계)

  • 박인덕;안형회;송강석;이희만;김시경
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.5
    • /
    • pp.368-373
    • /
    • 2003
  • This paper presents a cost-effective 3D foot scanner system that provides the 3-dimensional point cloud foot data to design the custom footwear. To measure the 3-dimensional point cloud data of the foot, a CCD camera, a Non-Gaussian laser line projector and optical triangulation method are employed. Furthermore, the integrated system employs a measurement base, a frame grabber, a CCD moving cart, a stepping motor and a computer. The measurement result is saved as 3D dxf format and it could be converted to 2D essential data fer a shoe design. The experimental results demonstrate that the proposed system have the decent resolution of 1mm which is enough for last and shoe design.