• 제목/요약/키워드: Design structure

검색결과 17,885건 처리시간 0.045초

심장박동기용 시그마 델타 A/D 변환기에서의-저전력 데시메이션 필터 구조 (Low-power Decimation Filter Structure for Sigma Delta A/D Converters in Cardiac Applications)

  • 장영범;양세정;유선국
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권2호
    • /
    • pp.111-117
    • /
    • 2004
  • The low-power design of the A/D converter is indispensable to achieve the compact bio-signal measuring device with long battery duration. In this paper, new decimation filter structure is proposed for the low-power design of the Sigma-Delta A/D converter in the bio-instruments. The proposed filter is based on the non-recursive structure of the CIC (Cascaded Integrator Comb) decimation filter in the Sigma-Delta A/D converter. By combining the CSD (Canonic Signed Digit) structure with common sub-expression sharing technique, the proposed decimation filter structure can significantly reduce the number of adders for implementation. For the fixed decimation factor of 16, the 15% of power consumption saving is achieved in the proposed structure in comparison with that of the conventional polyphase CIC filter.

A Design Optimization of Asymmetric Air-gap Structure for Small 3-phase Permanent Magnet SPM BLDC Motor

  • Kam, Seung-Han;Jung, Tae-Uk
    • Journal of Magnetics
    • /
    • 제20권1호
    • /
    • pp.91-96
    • /
    • 2015
  • As many researchers are relentlessly trying to improve the power generation schemes from the power grid, to meet the constantly increasing electricity demand. In this paper, the results of a finite element analysis are carried out to study on a design optimization of an asymmetric air-gap structure in 3-phase Permanent Magnet Brushless DC Motors. To achieve a high efficiency for a 3-phase PM BLDC motor, the asymmetric air-gap structure is proposed considering the rotation direction of a motor. Generally, a single-phase BLDC motor is applied asymmetric air-gap structure for starting. This is because the asymmetric air-gap structure causes reluctance variation so the motor can utilize reluctance torque toward a rotation direction. In this paper, the asymmetric air-gap is applied to 3-phase BLDC SPM motor so it utilizes reluctance torque with alignment torque. A proposed model is designed by 2-D FE analysis and the results are verified by experimental test.

인대 구조에서 기인한 전완 메커니즘과 자유도 해석 (Forearm Mechanism Inspired by Ligamentous Structure and Its Mobility Analysis)

  • 이건;이호
    • 로봇학회논문지
    • /
    • 제17권2호
    • /
    • pp.209-215
    • /
    • 2022
  • In this paper, a forearm Mechanism design inspired by ligamentous structure of the human body is proposed. The proposed mechanism consists of four rigid bodies and fourteen wires without any mechanical joints. Actually, the mechanism is based on the concept of the tensegrity structure. Therefore, the proposed mechanism has inherently compliant characteristics due to the flexibility of the wires composing the structure. Rigid bodies and wires of the mechanism mimic bones and major ligaments in the forearm of the human. The proposed mechanism is classified as one of the interconnected hybrid flexure systems. The analysis method of the degree of freedom (DOF) of the proposed mechanism is also introduced through analyzing technique of the interconnected hybrid flexure systems, in this paper. Ultimately, the proposed mechanism, whose structure is complicated with rigid bodies and wires, mathematically drives that it has 3-DOFs.

Trenched-Sinker LDMOSFET (TS-LDMOS) Structure for 2 GHz Power Amplifiers

  • Kim, Cheon-Soo;Kim, Sung-Do;Park, Mun-Yang;Yu, Hyun-Kyu
    • ETRI Journal
    • /
    • 제25권3호
    • /
    • pp.195-202
    • /
    • 2003
  • This paper proposes a new LDMOSFET structure with a trenched sinker for high-power RF amplifiers. Using a low-temperature, deep-trench technology, we succeeded in drastically shrinking the sinker area to one-third the size of the conventional diffusion-type structure. The RF performance of the proposed device with a channel width of 5 mm showed a small signal gain of 16.5 dB and a maximum peak power of 32 dBm with a power-added efficiency of 25% at 2 GHz. Furthermore, the trench sinker, which was applied to the guard ring to suppress coupling between inductors, showed an excellent blocking performance below -40 dB at a frequency of up to 20 GHz. These results confirm that the proposed trenched sinker should be an effective technology both as a compact sinker for RF power devices and as a guard ring against coupling.

  • PDF

무곱셈 대각 보간 필터의 설계 및 VLSI 구현에 관한 연구 (On the Design Technique and VLSI Structure for a Multiplierless Quincuncial Interpolation Filter)

  • 최진우;이상욱
    • 전자공학회논문지B
    • /
    • 제29B권8호
    • /
    • pp.54-65
    • /
    • 1992
  • A huge amount of multiplications is required for 2-D filtering on the image data, making it difficult to implement a real-time quincuncial interpolator. In this paper, efficient design technique and VLSI structures for 2-D multipleierless filter are presented. In the filter design, by introducing an efficient scheme for discretizing the frequency response of the prototype filter, it is shown that a significant amount of the computational burden required in the conventional techniques, such as local search, branch and bound techniques, could be saved. In the case of 5$\times$5 filter, it is found that the design technique described in this paper could save about 80% of the computation time, compared to the conventional methods, while providing a comparable performance. For a hardware implementation, two different VLSI structures for 2-D multiplierless filter are also introduced in the paper : One is for block parallel processing and the other for scan-line parallel processing. In both structure, the AP(area-period) figure improves over Wu's structure[4].

  • PDF

미앤더 라인을 이용한 RFID 태그 안테나 최적 설계 (Optimized Design of a Tag Antenna for RFID using a Meander Line)

  • 김형석
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2293-2298
    • /
    • 2011
  • In this paper, A tag antenna structure for RFID application with resonant frequency of 920MHz is proposed using the meander line technique and Evolution Strategy. Miniaturization structure design for a tag antenna is performed by structure combining the half-wave dipole with a meander line. To achieve this, an interface program between a commercial EM analysis tool and the optimal design program is made for implementing the evolution strategy technique that seeks a global optimum of the objective function through the iterative design process consisting of variation and reproduction. The optimized tag antenna size is 63mm ${\times}$ 15mm ${\times}$ 1mm. And the proposed antenna is realized on FR-4 substrate (${\epsilon}_r=4.4$, $tna{\delta}=0.02$).

유용방향법 최적화 알고리즘을 사용한 고유진동수에 대한 구조 최적설계 FEA 모듈 개발 (Structure Optimization FEA Code Development Under Frequency Constraints by Using Feasible Direction Optimization Method)

  • 조희근
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.63-69
    • /
    • 2013
  • In order to find the optimum design of structures that have characteristic natural frequency range, a numerical optimization method to solving eigenvalue problems is a widely used approach. However in the most cases, it is difficult to decide the accurate thickness and shape of structures that have allowable natural frequency in design constraints. Parallel analysis algorithm involving the feasible direction optimization method and Rayleigh-Ritz eigenvalue solving method is developed. The method is implemented by using finite element method. It calculates the optimal thickness and the thickness ratio of individual elements of the 2-D plane element through a parallel algorithm method which satisfy the design constraint of natural frequency. As a result this method of optimization for natural frequency by using finite element method can determine the optimal size or its ratio of geometrically complicated shape and large scale structure.

RC 건물에서 주축의 설정이 설계지진력에 미치는 영향 (Effect of Reference Axis of RC Buildings on Seismic Design Member Forces)

  • 이한선;고동우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.704-707
    • /
    • 2004
  • The structure should be designed to be safe to any direction of earthquake input. However, the reference axes whereby the structure is analyzed and designed against earthquake may influence the design member forces. This study is concerned with the effect of the choice of the reference axes on the seismic design member forces. The analytical results on member forces using the principal axes suggested by Wilson and the global axes generally adopted in design offices show that the values of member forces by the principal axes be about $15\%$ smaller than those by the global axes in the example structure.

  • PDF

마스터-슬레이브 조작기에서 제한된 힘반영제어기 구조를 고려한 Tendon 설계 (Tendon Design for Master-slave Manipulator in Consideration of Constrained Force Reflection Control Structure)

  • 강민식;윤우현
    • 한국소음진동공학회논문집
    • /
    • 제19권10호
    • /
    • pp.1043-1052
    • /
    • 2009
  • In this work, a master-slave manipulator system which will be used for handling objects contaminated by radioactivity has been addressed. The links of manipulators are driven independently by individual motors installed on the base and the driving torque is transmitted through pre-tensioned tendons. Since the measurable variables are the positions and rates of master/slave motors, only a constrained specific bilateral control structure is available. In the consideration of the flexibility of the tendon and constrained control structure, we derived a necessity for tendon design to prevent uncontrollable vibration mode through a modal analysis. Based on a reduced rigid body model, a control design was suggested and tendons were selected. The feasibility of the proposed analysis and tendon design were verified along with some simulation results.

Seismic design of a precast r.c. structure equipped with viscous dampers

  • Silvestri, Stefano;Gasparini, Giada;Trombetti, Tomaso
    • Earthquakes and Structures
    • /
    • 제2권3호
    • /
    • pp.297-321
    • /
    • 2011
  • The seismic design of a two-storey precast reinforced-concrete building structure equipped with viscous dampers is presented in this paper with twofold purpose. The first goal is to verify the applicability of a practical procedure for the identification of the mechanical characteristics of the viscous dampers which allow to achieve target performance levels, originally proposed by the authors for moment-resisting building frames, also with reference to "pendular" structures. The second goal is to investigate the effectiveness of the use of viscous dampers (as compared with traditional lateral-resisting stiff braces) for the seismic design of precast not moment-resisting concrete structures.