• Title/Summary/Keyword: Dept. of dental technology

Search Result 525, Processing Time 0.023 seconds

A Study on the Noise Characteristics of noise occurred when medical examination in dental clinic

  • Ji, Dong-Ha;Lee, Yong-Gyoo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.12
    • /
    • pp.163-170
    • /
    • 2018
  • This study was conducted to investigate the effects of noise from dental clinics on workers and to establish a reduction plan. The noise generated by the treatment instrument(Ultrasonic scaler, Hand piece, 3-way syringe, Suction, Compressor) was measured in order to determine the characteristics(level, frequency) of the noise during medical treatment(Oral prophylaxis, Conservation treatment, Prosthesis treatment, Implant Scaling, Tooth eliminating). We also assessed the noise levels in dental clinic using evaluation indicators such as NR-curves and NRN. The results of the analysis showed that the noise generated during the treatment was 85dB(A) ~ 70dB(A) and that the high frequency component was dominant, which would affect the workers working at the dental clinic. The NR-curve analysis showed NR-67 to NR-83 and the high frequency components of 4kHz to 8kHz were predominant and far exceeded noise levels in the workplace. To minimize the noise damage of workers and to provide high quality medical service, it is necessary to establish countermeasures such as wearing a soundproof and periodic hearing tests.

Grindability of Ti-Xwt%Cu Alloys for Dental Applications (치과용 Ti-Xwt%Cu 합금의 연삭성)

  • Ahn, Jae-Seok
    • Journal of Technologic Dentistry
    • /
    • v.31 no.4
    • /
    • pp.31-36
    • /
    • 2009
  • This study evaluated the grindability of series of Ti-Cu alloys in order to develop a Ti alloy with better grindability than commercially pure titanium(CP Ti). Experimental Ti-Xwt%Cu alloys(X=2, 5, 10) were made in an argon-arc melting furnace. Slabs of experimental alloys were ground using a SiC abrasive wheel on an electric handpiece at circumferential speed(15000, 30000rpm) by applying a force(250, 300gr). Grindability was evaluated by measuring the amount of metal volume removed after grinding for 2 minutes. Data were compared to those for CP Ti and Ti-6wt%Al-4wt%V alloy. From results, It was observed that the grindability of Ti-Cu alloys increased with an increase in the Cu concentration compared to CP Ti, particularly the 10wt%Cu alloy exhibited the highest grindability at all speeds. By alloying with Cu, the Ti exhibited better grindability at high speed. The continuous precipitation of $Ti_2Cu$ among the ${\alpha}$-matrix grains made this material less ductile and facilitated more effective grinding because small segments more readily formed. The Ti-10wt%Cu alloy has a great potential for use as a dental machining alloy.

  • PDF

A Patient's Satisfaction with Denture in the Old People (노인들의 의치 장착 후의 만족도에 관한 연구)

  • Lee, In-Kyu;Song, Yun-Hee
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.61-74
    • /
    • 2002
  • This experiment was to find out the complacency of wearing dentures and the linkage to the quality of life style of oldsters 60 years old and over. 122 numbers of oldsters who came to aid to the health center were put to survey. This was taken place within the areas of Deajun, Koonsan, Mooju and Jinahn, thus procured the following result. 1. The length of edentulous period of 1-6years of oldsters aged around 60s showed 26.0%. The oldsters with edentulous period of over 7years aged in the 70s showed 26.1 % and 56.0% on oldsters aged in the 80s. This shows that as the age increases the edentulous period lengthens. (P<0.05) The length of time of using the denture shows. llyears or over on women 41.9%, less than 6years on men 71.4% as the highest rate. 11 years or over on towns/subcounty show 57.5%, small and medium cities more than 1 year 63.6%, less than six years also 63.6% and Kwangyuk city 47.6%. 2. The complacency on medical treatment of dentures was highest in Kwangyuk city of 61.3%, compared to towns/subcounty of 50.8% and small and medium cities of 33.3%. (P<0.05) 3. The complacency on mastication and pronunciation appears, 2.74% in Kwangyuk city, 3.10% in towns/ subcounty which is higher than the small and medium cities showing 1.09% on average. Satisfaction rate tends to be higher as the length of time of using the denture is longer. 4. Inconvenience on eating habits caused by dentures were felt by women. Wanting to get a new denture was 25.6% by women showing much higher rate than that of men which is 2.8% by men. (P<0.05) 5. The complacency of change in their life style after wearing the dentures were higher in Kwangyuk city of 64.5% whereas it showed 27.0% in towns! subcounty and 16.7%in small and medium cities. (P<0.05)

  • PDF

A Comparison of the Appearance in Implant Success according to Membrane Type during GBR(Guided Bone Regeneration) (골유도 재생술식(GBR)시 차단막 종류에 따른 임플란트 결과 비교)

  • Lee, Sunmi;Kim, Jiyoung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.2
    • /
    • pp.41-47
    • /
    • 2014
  • Purpose : The aim was to compare the implant success rate according to membrane type through a clinical case of patients, who used bio-resorbable membrane and non-resorbable membrane. Methods : A survey was conducted targeting patients with the use of bio-resorbable membrane and non-resorbable membrane who visited H dental clinic in Busan for implant surgery and bone graft for 1 year from May 2010 to May 2011. A chart was made and surveyed for 100 people with non-resorbable membrane and for 75 people with bio-resorbable membrane. Results were compared. Results : 1. As for the measurement value of Periotest M${(R)}$, the value of -8~0 was measured with 92% in case of surgery by using non-resorbable membrane. The value of +1~+9 was measured with 8.0%. In case of surgery by using bio-resorbable membrane, Peiotest M(R) was measured with 78.7% as for the value of -8~0 and 16(21.3%) as for the value of +1~+9. In light of this, a case of using non-resorbable membrane was indicated to be higher(p=0.021) in success rate than a case of using bio-resorbable membrane. 2. As a result of periodontal conditions, namely, bleeding(p=0.914), swelling(p=0.500), inflammation(p=0.074), pain(p=0.571), and itch appearance(p=0.475) according to membrane type, all were insignificant. Conclusions : A case of using non-resorbable membrane is considered to be likely to be more effective than using bio-resorbable membrane during GBR(Guided Bone Regeneration) with the use of membrane in implant surgery.

A Study on the Castability of Non-precious Porcelain Metal According to Investing Method (매몰방법에 따른 도재용 비금속의 주조성에 관한 연구)

  • Lee, In-Kyu;Kim, Yong-Won
    • Journal of Technologic Dentistry
    • /
    • v.19 no.1
    • /
    • pp.5-12
    • /
    • 1997
  • To examine the difference of castability of non -precious porcelain metal according to 2 type of investing method, experiments were carried out using the method of both existing investing method and the investment with spaces to the upper & lower parts of the ring. The following conclusion were obtained from the result. 1. Seperataly using the existing investment and with spaces to the upper & lower parts of the ring, 44 samples resulted in success with the former method and 52 with the latter out of 84 samples. 2. Under the existing investing method, 44 samples out of 56 total resulted in success when the temperature of the ring was $870^{\circ}C$, and all samples failed when the temperature was $800^{\circ}C$. 3. Under the investment that gives space to the ring, when casted with the temperature of the ring fixed at $870^{\circ}C$, 40 samples out of 56 and 17 samples with the temperature fixed at $800^{\circ}C$ resulted in success. 4. Under the existing investing method with the temperaure of the ring fixed at $870^{\circ}C$ and heat soaking time given an hour, 26 out of 28 samples resulted in success and 18 resulted the same with half an hour heat soaking time. 5. Using the investment that gives space to the ring, at ring temperature $870^{\circ}C$ with heat soaking time 1 hour, all of total 28 rusulted insuccess however only 12 smaples succeeded with 30 minutes heat soaking time. 6. Under the existing investing method, samples with heat soaking time 1 hour equally given at ring temperature $870^{\circ}C$, 26 samples out of 28 succeed however at $800^{\circ}C$ all samples failed. 7. In the case of ring's upper and lower parts opened ring temperature is $870^{\circ}C$ and $800^{\circ}C$ and the heat soaking time was fixed at 1 hour, all 28 samples resulted in success and at $800^{\circ}C$ 17 succeed.

  • PDF

A Study on the Continuing Education of Dental Technicians (치과기공사의 보수교육에 관한 연구(I) -보수교육 실태와 인식을 중심으로 -)

  • Moon, Je-Hyuk
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.179-198
    • /
    • 2000
  • Since dental prosthesis is made possible only when dental technicians give themselves to the study of knowledge and the acquisition of updated skills, continuing education is of great importance in that it makes up for the efforts of dental technicians. Accordingly, continuing education relates to a system designed to contribute to the enhancement of the talents of dental technicians and the dental health of the nation. Specialized knowledge and information may work as the best weapon to preserve their jbs. This is true of this modern society where no one can expecth to survive without acquiring knowledge and information constantly for work is getting more classified and more divirsifide. This paper is dedicated to take a look at the current condition of the continuing education of dental technicians and to come up with measure to make general evaluation and to improve continuing education. This research resorts to 609 questionnaires among 6433 copies save unfaithfully responded 34 copos with 6.431 dental technicians as the subjects enrolled in the Dental technician Association. The collected questionnaires consist of 365 dental technicians living in Seoul and of 244 ones, Which account for 11.8 percent of dental technicians enrolled in the association. Because dental technicians live more in local areas than Seoul, the generalization of this survey leaves something to be desired. I have come up with the following findings. 1. 6,431 dental technicians, or 36.3 percent of an total of 14,956 licensed dental technicians, were admitted as numbers of the Dental Tachnician Association as of October 31, 1999. In the '98 continuing education. 4,141 dental technicians among 4,711 dental technicians got relevant training, and in the '99 continuing education, 4,075 technicians, or 75.9 percent of 5,365 technicians got relevant training while 1,290 technicians or 24.2 percent, fail to get relevant training. 2. The survey has it that 38.1 percent of dental technicians are ignorant of the laws on continuing education, and that technicians staying in local communities(146 persons, or 61.6%) take more part in education than those living in the capital of Korea(159 persons, or 146%), and that the older they are, the more money they earn, the more carrer they have, the higher position they hold, the more part they take in education 3. According to the survey, those who have the experience of getting training more than three times account for 52 persons(16.8%) in Seoul and 47 persons(22.4%) in local districts(p<0.01). In terms of sanctions in relation to continuing education, 26 dental technicians(4.6%) say that they have ever gotten sanctions, and 533 dental technicians(95.4%) say that they haven't. And those who were absent from continuing education(72 technicians : 13.51%) didn't get any sanction. 4. In terms of the degree of understanding continuing education, local technicians(46.8% : 110 persons) have a higher understanding of continuing education than their countparts staying in Seoul(36.0% : 130). Continuing education is not the ultimate goal itself. It should be changed to motivate those who get education to be willing to take part in contunuing education, and to help dental technicians in a practical and specific way. And the branch societies should be developde to engage in more specialized and classified expert fields. Of course, the curriculum should be so selected that the conceptions of dental technicians may be reflected to the maximum extent, and the ultimate effores should be made to effect diversity in the ways of educational methods and to perfect the preparation of continuing education on the part of instructors. Regulations should be established in relation to continuing education with a veiew to enhancing the participation of continuing education and its effectiveness. The supervision of the Ministry of Health and Welfare is of great importance in this context. The regulation of continuing education is not administrative regulation, but the expression of national will to guarantee the medical service of the nation at highest level. Therefore, it is necessary that the Ministry of Health and Welfare should change their understanding of the needs for the continuing education of dental experts, and that the expertise of government employees in charge of continuing education should be expanded. It goes without saying that the government should suppory continuing education in a financial way so as to supply the person in charge of public welfare and control the quality of national medicine.

  • PDF

A Study on EPMA on Ni-Cr Alloy by Nb content for Porcelain Fused to Metal Crown (Nb이 첨가된 금속소부도재관용 Ni-Cr 합금 표면의 EPMA 관찰)

  • Kim, Chi-Young;Choi, Sung-Min;Cho, Hyeon-Seol
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.19-26
    • /
    • 2006
  • The effect of Nb on interfacial bonding characteristics of Ni-Cr alloy for porcelain fused to metal crown (PFM) has been studied in order to investigate oxide layer. A specimens of Ni-Cr alloy, which is 0.8mm in thickness, within the porcelain furnace of 1,000$^{\circ}C$ with four tests such as air, vacuum, air for 5 minutes and vacuum for 5 minutes in order to examine an oxide behavior of alloy surface generated by the adding of Nb to be controlled at a rate of 0, 1, 3 and 5. Oxide film was observed form of the fired specimens with scanning electron microscope (SEM), and at the same time it measured Electron Probe Micro Analyzer (EPMA). The result of this study were as follows: 1. Cr oxide film and Nb oxide film were observed from the surface of specimen to be controlled at a rate of Nb 1%. 2. Nb oxide film was observed from the interface of specimens to be controlled at a rate of Nb 1% and 3%. 3. The stability of oxide films that treated in air were more stable than treated under vacuum.

  • PDF

A Study on Improvement of Metal-Ceramic Bonding Strength by Addition of Aluminum to Casting Metal Alloy (도재주조용 합금에 있어서 알루미륨 첨가에 따른 metal-ceramic과의 결합력 증진에 관한 연구)

  • Lee, Jae-Won;Min, Byong-Kuk;Han, Min-Soo
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.161-170
    • /
    • 2002
  • The Purpose of this study was to investigate the chemically improvement of metal-ceramics bond strength in the course of recasting Ni-Cr metal composite system with 10wt.%, 20wt.% and 30wt.% aluminum respectively. We have tested the bond strength, micro-structure, chemical composition of each metal composites and metal- ceramic bond interfaces by 3-point bending strength tester, SEM and EDS. We have made the conclusions through this study as follow: 1. The most suitable amount of aluminum to the Ni-Cr metal composite recasting is 20wt. % for improving metal-ceramics bond strength with debonding strength value of 49.54 kgf/mm2. 2. The aluminum must be changed to small spread alumina like phases and second aluminum-metal composites phases in the morphology of Ni-Cr metal composite system by adding during it's casting. These second phases have inclined functional oxide phases mixed with metal elements and they must take roll to improvement of metal-ceramics bond strength. 3. In the case of 30wt.% aluminum appended to Ni-Cr metal composite system, an excess of second inclined functional oxide phases produce cracks and spalling of them apart from it's base material. It must be a important factor of reduction of metal-ceramics bond strength.

  • PDF

Elemental alteration of the surface of dental casting alloys induced by electro discharge machining (치과용 주조 합금의 방전가공에 따른 표면 성분 변화)

  • Jang, Yong-Chul;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.55-61
    • /
    • 2009
  • Passive fitting of meso-structure and super-structures is a predominant requirement for the longevity and clinical success of osseointegrated dental implants. However, precision and passive fitting has been unpredictable with conventional methods of casting as well as for corrective techniques. Alternative to conventional techniques, electro discharge machining(EDM) is an advanced method introduced to dental technology to improve the passive fitting of implant prosthesis. In this technique material is removed by melting and vaporization in electric sparks. Regarding the efficacy of EDM, the application of this technique induces severe surface morphological and elemental alterations due to the high temperatures developed during machining, which vary between $10,000{\sim}20,000^{\circ}C$. The aim of this study was to investigate the morphological and elemental alterations induced by EDM process of casting dental gold alloy and non-precious alloy used for the production of implant-supported prosthesis. A conventional clinical dental casting alloys were used for experimental specimens patterns, which were divided in three groups, high fineness gold alloy(Au 75%, HG group), low fineness gold alloy(Au 55%, LG group) and nonprecious metal alloy(Ni-Cr, NP group). The UCLA type plastic abutment patterns were invested with conventional investment material and were cast in a centrifugal casting machine. Castings were sandblasted with $50{\mu}m\;Al_2O_3$. One casting specimen of each group was polished by conventional finishing(HGCON, LGCON, NPCON) and one specimen of each group was subjected to EDM in a system using Cu electrodes, kerosene as dielectric fluid in 10 min for gold alloy and 20 min for Ni-Cr alloy(HGEDM. LGEDM, NOEDM). The surface morphology of all specimens was studied under an energy dispersive X-ray spectrometer (EDS). The quantitative results from EDS analysis are presented on the HGEDM and LGEDM specimens a significant increase in C and Cu concentrations was found after EDM finishing. The different result was documented for C on the NPEDM with a significant uptake of O after EDM finishing, whereas Al, Si showed a significant decrease in their concentrations. EDS analysis showed a serious uptake of C and Cu after the EDM procedure in the alloys studied. The C uptake after the EDM process is a common finding and it is attributed to the decomposition of the dielectric fluid in the plasma column, probably due to the development of extremely high temperatures. The Cu uptake is readily explained from the decomposition of Cu electrodes, something which is also a common finding after the EDM procedure. However, all the aforementioned mechanisms require further research. The clinical implication of these findings is related with the biological and corrosion resistance of surfaces prepared by the EDM process.

  • PDF

Corrosion Characteristics of Cell-Covered Ternary Ti-Nb-Ta Alloy for Biomaterials

  • Kim, W.G.;Yu, J.W.;Choe, H.C.;Ko, Y.M.;Park, G.H.
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.62-67
    • /
    • 2009
  • Ti and Ti-alloys have good biocompatibility, appropriate mechanical properties and excellent corrosion resistance. However, the widely used Ti-6Al-4V is found to release toxic ions (Al and V) into the body, leading to undesirable long-term effects. Ti-6Al-4V has much higher elastic modulus (100 GPa) than cortical bone (20 GPa). Therefore, titanium alloys with low elastic modulus have been developed as biomaterials to minimize stress shielding. The electrochemical behavior of surface-modified and MC3T3-E1 cell-cultured Ti-30(Nb,Ta) alloys with low elastic modulus have been investigated using various electrochemical methods. Surfaces of test samples were treated as follows: $0.3{\mu}m$ polished; $25{\mu}m$, $50{\mu}m$ and $125{\mu}m$ sandblasted. Specimen surfaces were cultured with MC3T3-E1 cells for 2 days. Average surface roughness ($R_a$) and morphology of specimens were determined using a surface profilometer, OM, and FE-SEM. Corrosion behavior was investigated using a potentiostat(EG&G PARSTAT 2273), and electrochemical impedance spectroscopy was performed (10 mHz to 100 kHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The microstructures of the Ti-30(Ta,Nb) alloys had a needle-like appearance. The $R_a$ of polished Ti-30Ta and Ti-30Nb alloys was lower than that of the sandblasted Ti alloy. Cultured cells displayed round shapes. For polished alloy samples, cells were well-cultured on all surfaces compared to sandblasted alloy samples. In sandblasted and cell-cultured Ti-30(Nb,Ta) alloy, the pitting potential decreased and passive current density increased as $R_a$ increased. Anodic polarization curves of cell-cultured Ti alloys showed unstable behavior in the passive region compared to non-cell-cultured alloys. From impedance tests of sandblasted and cell-cultured alloys, the polarization resistance decreased as $R_a$ increased, whereas, $R_a$ for cell-cultured Ti alloys increased compared to non-cell-cultured Ti alloys.