• 제목/요약/키워드: Dental panoramic radiography

검색결과 219건 처리시간 0.02초

Effective dose from direct and indirect digital panoramic units

  • Lee, Gun-Sun;Kim, Jin-Soo;Seo, Yo-Seob;Kim, Jae-Duk
    • Imaging Science in Dentistry
    • /
    • 제43권2호
    • /
    • pp.77-84
    • /
    • 2013
  • Purpose: This study aimed to provide comparative measurements of the effective dose from direct and indirect digital panoramic units according to phantoms and exposure parameters. Materials and Methods: Dose measurements were carried out using a head phantom representing an average man (175 cm tall, 73.5 kg male) and a limbless whole body phantom representing an average woman (155 cm tall, 50 kg female). Lithium fluoride thermoluminescent dosimeter (TLD) chips were used for the dosimeter. Two direct and 2 indirect digital panoramic units were evaluated in this study. Effective doses were derived using 2007 International Commission on Radiological Protection (ICRP) recommendations. Results: The effective doses of the 4 digital panoramic units ranged between $8.9{\mu}Sv$ and $37.8{\mu}Sv$. By using the head phantom, the effective doses from the direct digital panoramic units ($37.8{\mu}Sv$, $27.6{\mu}Sv$) were higher than those from the indirect units ($8.9{\mu}Sv$, $15.9{\mu}Sv$). The same panoramic unit showed the difference in effective doses according to the gender of the phantom, numbers and locations of TLDs, and kVp. Conclusion: To reasonably assess the radiation risk from various dental radiographic units, the effective doses should be obtained with the same numbers and locations of TLDs, and with standard hospital exposure. After that, it is necessary to survey the effective doses from various dental radiographic units according to the gender with the corresponding phantom.

Clinical image quality evaluation for panoramic radiography in Korean dental clinics

  • Choi, Bo-Ram;Choi, Da-Hye;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Bae, Kwang-Hak;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • 제42권3호
    • /
    • pp.183-190
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the level of clinical image quality of panoramic radiographs and to analyze the parameters that influence the overall image quality. Materials and Methods: Korean dental clinics were asked to provide three randomly selected panoramic radiographs. An oral and maxillofacial radiology specialist evaluated those images using our self-developed Clinical Image Quality Evaluation Chart. Three evaluators classified the overall image quality of the panoramic radiographs and evaluated the causes of imaging errors. Results: A total of 297 panoramic radiographs were collected from 99 dental hospitals and clinics. The mean of the scores according to the Clinical Image Quality Evaluation Chart was 79.9. In the classification of the overall image quality, 17 images were deemed 'optimal for obtaining diagnostic information,' 153 were 'adequate for diagnosis,' 109 were 'poor but diagnosable,' and nine were 'unrecognizable and too poor for diagnosis'. The results of the analysis of the causes of the errors in all the images are as follows: 139 errors in the positioning, 135 in the processing, 50 from the radiographic unit, and 13 due to anatomic abnormality. Conclusion: Panoramic radiographs taken at local dental clinics generally have a normal or higher-level image quality. Principal factors affecting image quality were positioning of the patient and image density, sharpness, and contrast. Therefore, when images are taken, the patient position should be adjusted with great care. Also, standardizing objective criteria of image density, sharpness, and contrast is required to evaluate image quality effectively.

Interobserver agreement on the diagnosis of carotid artery calcifications on panoramic radiographs

  • Yoon, Suk-Ja;Shim, Sung-Kyun;Lee, Jae-Seo;Kang, Byung-Cheol;Lim, Hoi-Jeong;Kim, Min-Seok;Kim, Sun-Hun
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.137-141
    • /
    • 2014
  • Purpose: This study was performed to investigate the interobserver agreement on the detection of carotid artery calcifications on panoramic radiographs. Materials and Methods: This study consisted of panoramic radiographs acquired from 634 male patients of the age of 50 years or older. Having excluded carotids of no diagnostic quality, 1008 carotids from the panoramic radiographs of the patients were interpreted by two oral and maxillofacial radiologists independently for the presence of carotid artery calcifications. Statistical analysis was used to calculate the interobserver agreement. Results: Interobserver agreement was obtained for 932 carotids (92.4%). Inconsistent interpretation of 76 carotids (7.5%) between the two observers was found. Cohen's kappa value was 0.688 (p<0.001). Conclusion: The probability of a match between the two observers was substantially high.

STUDY ON ENTRANCE SKIN DOSE AT PANORAMIC RADIOGRAPHY IN INCHEON, KOREA

  • Choi, Jung-Hyun;Kim, Sung-Chul;Han, Dong Kyoon
    • Journal of Radiation Protection and Research
    • /
    • 제39권4호
    • /
    • pp.182-186
    • /
    • 2014
  • Recently, the use of panoramic radiography has shown a constant increase, and significant research is underway. However, radiation exposure attracts less attention in dental radiography than in other types of radiography. We used an OSLD for measurement of the entrance skin dose in eyeballs and the thyroid region, both of which are not covered by examinations but are included in radiographical regions and are sensitive to radiation, as well as orally in Incheon and reported the results. The entrance skin dose was 0.0282 mSv on average for the oral region, and 0.0259 mSv on average for the eyeball, and 0.0261mSv on average, for thyroid gland. While there is no proper shielding method for the eyeball, a thyroid protector is not used by most hospitals and most hospitals are equipped with an apron and a thyroid protector separately; thus, it is necessary to use an integration of an apron and a thyroid protector and medical device manufacturers need to develop a method for controlling the length of the slit in the slit-type area of radiation occurrence in order to reduce unnecessary exposure.

파노라마방사선사진에서 골형태 계측과 구내표준필름에서 구리당량치의 상관관계 (The correlationship between mandibular radiomorphometric indices in panorama and bone mineral density in Cu-equivalent image of intraoral film)

  • 김재덕
    • Imaging Science in Dentistry
    • /
    • 제33권3호
    • /
    • pp.131-135
    • /
    • 2003
  • Purpose: To determine whether the mandibular radiomorphometric indices in panoramic radiography are correlated with the bone mineral density of Cu-equivalent images in intraoral film. Materials and Methods: The bone mineral density (BMD) of the mandibular premolar area was measured in the Cu-equivalent image of intraoral film. The Panoramic Mandibular Index (PMI) and Mandibular Cortical Width (MCW) were measured in panoramic radiographs of six dry mandibles, and the Pearson correlation between PMI, MCW, and BMD were tested. Results: There were no significant correlations between PMI and BMD (r = 0.280), nor between MCW and BMD (r =0.237). Conclusion: The results show that PMI and MCW were poor diagnostic indicators of mandibular BMD in the six dry mandibles used in this study. The correlationship between the mandibular radiomorphometric indices (PMI and MCW) and mandibular BMD needs to be researched further using large in vivo patient samples.

  • PDF

Evaluation of deep learning and convolutional neural network algorithms for mandibular fracture detection using radiographic images: A systematic review and meta-analysis

  • Mahmood Dashti;Sahar Ghaedsharaf;Shohreh Ghasemi;Niusha Zare;Elena-Florentina Constantin;Amir Fahimipour;Neda Tajbakhsh;Niloofar Ghadimi
    • Imaging Science in Dentistry
    • /
    • 제54권3호
    • /
    • pp.232-239
    • /
    • 2024
  • Purpose: The use of artificial intelligence (AI) and deep learning algorithms in dentistry, especially for processing radiographic images, has markedly increased. However, detailed information remains limited regarding the accuracy of these algorithms in detecting mandibular fractures. Materials and Methods: This meta-analysis was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Specific keywords were generated regarding the accuracy of AI algorithms in detecting mandibular fractures on radiographic images. Then, the PubMed/Medline, Scopus, Embase, and Web of Science databases were searched. The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool was employed to evaluate potential bias in the selected studies. A pooled analysis of the relevant parameters was conducted using STATA version 17 (StataCorp, College Station, TX, USA), utilizing the metandi command. Results: Of the 49 studies reviewed, 5 met the inclusion criteria. All of the selected studies utilized convolutional neural network algorithms, albeit with varying backbone structures, and all evaluated panoramic radiography images. The pooled analysis yielded a sensitivity of 0.971 (95% confidence interval [CI]: 0.881-0.949), a specificity of 0.813 (95% CI: 0.797-0.824), and a diagnostic odds ratio of 7.109 (95% CI: 5.27-8.913). Conclusion: This review suggests that deep learning algorithms show potential for detecting mandibular fractures on panoramic radiography images. However, their effectiveness is currently limited by the small size and narrow scope of available datasets. Further research with larger and more diverse datasets is crucial to verify the accuracy of these tools in in practical dental settings.

Diagnostic performance of dental students in identifying mandibular condyle fractures by panoramic radiography and the usefulness of reference images

  • Cho, Bong-Hae
    • Imaging Science in Dentistry
    • /
    • 제41권2호
    • /
    • pp.53-57
    • /
    • 2011
  • Purpose : The purpose of this study was to evaluate the diagnostic performance of dental students in detection of mandibular condyle fractures and the effectiveness of reference panoramic images. Materials and Methods : Forty-six undergraduates evaluated 25 panoramic radiographs for condylar fractures and the data were analyzed through receiver operating characteristic (ROC) analysis. After a month, they were divided into two homogeneous groups based on the first results and re-evaluated the images with (group A) or without (group B) reference images. Eight reference images included indications showing either typical condylar fractures or anatomic structures which could be confused with fractures. Paired t-test was used for statistical analysis of the difference between the first and the second evaluations for each group, and student�fs t-test was used between the two groups in the second evaluation. The intra- and inter-observer agreements were evaluated with Kappa statistics. Results : Intra- and inter-observer agreements were substantial (k=0.66) and moderate (k=0.53), respectively. The area under the ROC curve (Az) in the first evaluation was 0.802. In the second evaluation, it was increased to 0.823 for group A and 0.814 for group B. The difference between the first and second evaluations for group A was statistically significant (p<0.05), however there was no statistically significant difference between the two groups in the second evaluation. Conclusion : Providing reference images to less experienced clinicians would be a good way to improve the diagnostic ability in detecting condylar fracture.

워터스, 파노라마 방사선사진과 Scanora$\textregistered$ 방사선사진의 상악동 점막비후 진단 결과의 비교 (A COMPARISON OF SCANORA$\textregistered$ RADIOGRAPHY WITH WATERS' AND PANORAMIC VIEWS FOR THE DETECTION OF MUCOSAL THICKENING OF MAXILLARY SINUS)

  • 윤숙자;정현대;강병철
    • 치과방사선
    • /
    • 제25권2호
    • /
    • pp.389-398
    • /
    • 1995
  • The purpose of this study was to compare the diagnostic performance of Waters' and panoramic view; maxillary sinus posteroanterior and lateral scanography of Scanora/sup (R)/ for mucosal thickening of maxillary sinus as well as to identify the utility of Scanora/sup (R)/ for the detection of maxillary sinus disease. The assessment was done at 66 maxillary sinuses in 45 patients and the results were as follows ; 1. Estimation of presence or absence of mucosal thickening. The sensitivity, specificity, and positive and negative predictive value of maxillary sinus posteroanterior and lateral scanography were 0.865, 0.860, 0.921, and 0.805 respectively and slightly higher than those of Waters' and panoramic views, which were 0.832, 0.835, 0.903, and 0.728 respectively. However, paired t-test showed no significant differences in the diagnostic performance of the two pairs of imaging modalities. 2. Estimation of the types of mucosal thickening. The diagnostic accuracy for type I, II, III was 75.3% on Waters' and panoramic view; 77.9% on maxillary sinus posteroanterior and lateral scanography. It was higher on the latter ,but showed no significant differences from that on the former. 3. Reliability of interpretation. In itraobserver and interobserver agreement, both overall rates of agreement and kappa-value were slightly higher on maxillary sinus posteroanterior and lateral scanography than on Waters' and panoramic views. There was no significant differences between the two pairs of imaging modalities. These results suggested that scanogram is a useful diagnostic radiography as well as Waters' and panoramic views for detection of maxillary sinusitis.

  • PDF

Comparison of accuracy between panoramic radiography, cone-beam computed tomography, and ultrasonography in detection of foreign bodies in the maxillofacial region: an in vitro study

  • Abdinian, Mehrdad;Aminian, Maedeh;Seyyedkhamesi, Samad
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제44권1호
    • /
    • pp.18-24
    • /
    • 2018
  • Objectives: Foreign bodies (FBs) account for 3.8% of all pathologies of the head and neck region, and approximately one third of them are missed on initial examination. Thus, FBs represent diagnostic challenges to maxillofacial surgeons, rendering it necessary to employ an appropriate imaging modality in suspected cases. Materials and Methods: In this cross-sectional study, five different materials, including wood, metal, glass, tooth and stone, were prepared in three sizes (0.5, 1, and 2 mm) and placed in three locations (soft tissue, air-filled space and bone surface) within a sheep's head (one day after death) and scanned by panoramic radiography, cone-beam computed tomography (CBCT), and ultrasonography (US) devices. The images were reviewed, and accuracy of the detection modalities was recorded. The data were analyzed statistically using the Kruskal-Wallis, Mann-Whitney U-test, Friedman, Wilcoxon signed-rank and kappa tests (P<0.05). Results: CBCT was more accurate in detection of FBs than panoramic radiography and US (P<0.001). Metal was the most visible FB in all of modalities. US was the most accurate technique for detecting wooden materials, and CBCT was the best modality for detecting all other materials, regardless of size or location (P<0.05). The detection accuracy of US was greater in soft tissue, while both CBCT and panoramic radiography had minimal accuracy in detection of FBs in soft tissue. Conclusion: CBCT was the most accurate detection modality for all the sizes, locations and compositions of FBs, except for the wooden materials. Therefore, we recommend CBCT as the gold standard of imaging for detecting FBs in the maxillofacial region.

파노라마 방사선사진과 구내 방사선사진에서 골조직 정량평가의 비교연구 (A comparative study of the quantitative assessment on the panoramic and intraoral radiographs)

  • 김재덕
    • Imaging Science in Dentistry
    • /
    • 제31권3호
    • /
    • pp.129-133
    • /
    • 2001
  • Purpose: To compare the copper equivalent values measured at premolar and molar areas in the copper equivalent images of panoramic and intraoral radiographs and to evaluate the possibility of the copper equivalent images of panorama for the assessment the bone density. Materials and Methods : Intraoral radiograms at mandibular premolar and molar area and panoramas of 6 human dry skulls were taken with copper-step wedge by Heliodent MD (Siemens Co., Germany) and by Planmeca (PM 2002 CC, Planmeca, Helsinki, Finland) were used for experiment. The copper equivalent values measured at premolar and molar areas in the copper equivalent im ages of panorama and intraoral film were compared. Results: The copper equivalent values were ranged 0.20 mmCu-0.44 mmCu at the molar areas, 0.05 mmCu-0.31 mmCu at the premolar areas on panoramic images. There were no significant differences (p>0.5) between the copper equivalent values on intraoral images and those on panoramic images measured at premolar areas and molar areas respectively. The correlation coefficient between the copper equivalent values on intraoral images and those on panoramic images was respectively 0.8495 at molar areas and 0.6184 at premolar areas. Conclusions : The copper equivalent images of panorama for the assessment the bone density appeared to be significant at molar area compared with the one of intraoral radiograph.

  • PDF