• 제목/요약/키워드: Dental models

검색결과 606건 처리시간 0.023초

CEREC system에서 사용하는 세라믹 소재로 가공된 CAD/CAM 전부도재관의 변연간격 비교분석 (Comparison of marginal gap of monolithic CAD/CAM-generated crowns according to the ceramic materials for CEREC system)

  • 김재홍;김기백;김사학
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.119-125
    • /
    • 2016
  • Purpose: The purpose of this study is to evaluate the marginal gap of all-ceramic crowns fabricated by CEREC$^{(R)}$ in-office CAD/CAM system. Methods: The mandibular first molar was selected as the abutment for the experiments. Thirty working models were prepared. VITA Mark II(VM) and VITA Enamic(VE), LAVA Ultimate(LU) blocks were milled using CEREC MCXL with CEREC 3D system to construct 10 crowns for each groups. To measure marginal gap, milled restorations were examined under digital microscope with scale under 160x magnifications. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test(${\alpha}=0.05$). Results: There was no significant difference in the marginal gap regarding to ceramic materials(p>0.05). Conclusion: Single crowns fabricated using CEREC in-office CAD/CAM system provided clinically acceptable marginal gap. This confirmed that the type of ceramic material used does not determine the precision of fit of a prosthesis.

레이저선택용융기술에 의해 제작된 금속 코어의 변연 적합도 분석 (An analysis of marginal adaptation of metal cores fabricated by selective laser sintering)

  • 김원수;김기백
    • 대한치과기공학회지
    • /
    • 제38권4호
    • /
    • pp.305-311
    • /
    • 2016
  • Purpose: The purpose of this study were to analysis of marginal adaptation of metal cores fabricated by selective laser sintering. Methods: Main model was prepared and ten stone models were fabricated. Ten single metal cores were fabricated by selective laser sintering(SLS group) and another ten single metal cores using lost wax technique and casting method were manufactured(CAST group). The marginal adaptation of metal cores were analysis using by the silicone replica technique. Silicone replicas were sectioned two times. The marginal adaptations were measured using by digital microscope. Statistical analyses was performed with independent t-test(${\bullet}{\cdot}=0.05$). Results: Means of marginal adaptations were 90.3 ${\ss}{\uparrow}$ for SLS group and 65.1 ${\ss}{\uparrow}$ for CAST group. Two groups were statistically significant differences (p < 0.05). Conclusion: Marginal adaptation of metal cores fabricated by selective laser sintering were ranged within the clinical recommendation.

A within-subject comparison of short implants in the posterior region: retrospective study of up to 10 years

  • Segalla, Douglas Blum;Villarinho, Eduardo Aydos;Correia, Andre Ricardo Maia;Vigo, Alvaro;Shinkai, Rosemary Sadami Arai
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권3호
    • /
    • pp.172-179
    • /
    • 2021
  • Purpose. This intra-patient retrospective study of up to 10 years evaluated the clinical success and risk factors of 6- and 8-mm long implants and their respective prostheses. Materials and Methods. The sample consisted of patients treated at a Military Polyclinic dental service, who received both 6- and 8-mm long tissue level implants in the posterior region of the same arch. Data were collected from the dental charts, clinical and radiographic exams, self-report of sleep bruxism, measurement of maximum occlusal force, and clinical crown-to-implant (C/I) ratio. Data were analyzed by descriptive and inferential statistics with univariate and hierarchical multivariate models, at the 0.05 significance level. Results. The 30 patients (27 women) had 85 implants and 83 prostheses. Two implants were lost before prosthesis installation (implant survival: 97.6%). Ten events of prosthetic complication (screw tightening loss) occurred in five patients (success rate: 87.9%) in a single moment. Only the variable C/I ratio had a significant effect for repairable prosthesis complication (P<.05). Conclusion. The results suggest that 6- and 8-mm long implants have similar long-term clinical success for implants and prostheses.

Factors Affecting Primary Stability on Sites of Alveolar Ridge Preservation Using Porcine-derived Bone Minerals

  • Lee, Su-Yeon;Lee, Young;Choi, Seong-Ho;Lee, Dong-Woon
    • Journal of Korean Dental Science
    • /
    • 제14권1호
    • /
    • pp.1-11
    • /
    • 2021
  • Purpose: The alveolar ridge preservation (ARP) is widely conducted for implant placement. However, experimental results using deproteinized porcine bone mineral (DPBM) have been scarce. This retrospective study evaluated factors affecting the primary stability of implants in an area where ARP was performed using DPBM. Materials and Methods: Thirty-eight patients were divided into two groups based on the primary stability, with torque value of 30 Ncm as borderline. To determine the factors that affect the primary stability of implants, we collected data from patients' medical records including age, sex, reentry time, socket location, remaining bone wall at the time of extraction, and type of collagen membrane, as well as from radiographs and histomorphometric analysis. Result: The results showed statistically significant difference for the remaining extraction socket wall (P=0.014), residual graft (P=0.029), and fibrovascular tissue (P=0.02) between the two groups. There was an insignificant tendency toward the time of reentry surgery (P=0.052) and location (P=0.077). All implants placed in sites using DPBM functioned well up to 3 years. Conclusion: Within the limitations of the present study, extraction socket wall, residual graft, and fibrovascular tissue can affect the primary stability at the time of implant placement on grafted sites using DPBM and collagen membranes. In addition, reentry time and locations can be considered. In future studies, comparative experiments in quantified models will be required to supporting the findings.

Generating 3-D Models of Human Motions by Motion Capture

  • Yamaguchi, I.;Tou, K.;Tan, J.K.;Ishikawa, S.;Naito, T.;Yokota, M.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1629-1632
    • /
    • 2003
  • A technique is presented for generating a compound human motion from its primitive motions obtained by a motion capture system. Some human fundamental motions are modeled in a 3-D way and registered as primitive motions. Because the factorization method is used for the motion capture, calibration of video cameras and connection of the motion in the direction of time is both unnecessary. Employing these motions, various compound human motions are generated by connecting the motions after having applied rotation and parallel transformation to them. Linear interpolation is done at the discontinuous boundary between primitive motions and smooth connection is achieved. Experimental results show satisfactory performance of the proposed technique. The technique may contribute to producing various complicated human motions without much effort using a strict motion capture system.

  • PDF

첨가법에 의해 제작된 단관의 내면 적합도 분석 (Analysis of internal fitness of single crown fabricated by additive method)

  • 김원수
    • 대한치과기공학회지
    • /
    • 제37권4호
    • /
    • pp.229-234
    • /
    • 2015
  • Purpose: The purpose of this study was to analysis the internal fitness of single crown fabricated by additive method technique. Methods: Study models were fabricated. Ten crowns were manufactured by additive method technique (AM group) and another ten crowns using conventional method were manufactured (CM group). The internal fitness of specimens were measured using silicone replica technique. Silicone replicas were sectioned one times (direction: from mesial to distal). The internal fitness were evaluated using by digital microscope. Statistical analyses were performed with independent samples t-test. (${\alpha}=0.05$). Results: Mean(SD) of all internal fitness were $92.1(20.0){\mu}m$ for AM group and $69.7(12.3){\mu}m$ for CM group. Two groups were statistically significant differences (p<0.001). Conclusion: All internal gaps of AM group were ranged within the clinical recommendation ($120{\ss}{\neq}$).

오픈-소스 소프트웨어를 이용한 콘빔 전산화단층영상의 중첩 및 시각화 (Cone-beam CT superimposition and visualization using open-source softwares)

  • 전우람;임성훈
    • 대한치과의사협회지
    • /
    • 제56권10호
    • /
    • pp.538-547
    • /
    • 2018
  • ITK-SNAP (http://www.itksnap.org) and 3D Slicer (CMFreg extension module; www.slicer.org) are open-source softwares which can be used for superimposition of cone-beam CT images. For superimposition, segmentation of bone is done with ITK-SNAP, and then voxel based superimposition of CBCT images can be performed using 3D Slicer. 3D Slicer has various visualization modules which are not provided in common commercial programs. 'Models' module is used to visualize two overlapping three-dimensional images, and this allows various visualizations by changing view mode and color of the model. In addition, differences between two CBCT images can be represented in a color map using 'ShapePopulationViewer' module. This report introduces how to superimpose and visualize CBCT images using ITK-SNAP and 3D Slicer, and the usefulness and limitations of both softwares will be discussed in comparison with commercial softwares.

  • PDF

영구치 전치의 근원심경과 치관 길이에 관한 연구 (A Study on the Mesio-Distal Crown Diameters and Crown Length of the Permanent Anterior Teeth)

  • 이태정
    • 대한치과기공학회지
    • /
    • 제13권1호
    • /
    • pp.21-26
    • /
    • 1991
  • The mesiodistal crown diameters and crown length of the permanent anterior teeth have been studied and analyzed about the mean size, S.D, S.E etcs from stone models of 100 Korean male and 74 female. From the study, the following conclusions were made : 1. Statistical differences of left and right teeth were not found in the mesio distal crown diameters and crown length of the permanent anterior teeth. 2. The mean values of mesiodistal crown diameters of permanent anterior teeth were slightly larger in male than in females and statistical differences of males and females were found in maxillary right central incisor, mandibular left canine, mandibular right lateral incisor and mandibular right canine. 3. The mean values of crown length of permanent anterior teeth were slightly larger in male than in female and statistical differences of males and females were found in mandibular left canine, mandibular right canine. 4. Mesiodistal crown diameters and crown length of maxillary left lateral incisors and right lateral incisors of female are larger than that of male.

  • PDF

치주질환의 면역학 (The Role of Immune Response in Periodontal Disease)

  • 김각균
    • IMMUNE NETWORK
    • /
    • 제3권4호
    • /
    • pp.261-267
    • /
    • 2003
  • The periodontal diseases are infections caused by bacteria in oral biofilm, a gelatinous mat commonly called dental plaque, which is a complex microbial community that forms and adhere to tooth surfaces. Host immune-pathogen interaction in periodontal disease appears to be a complex process, which is regulated not only by the acquired immunity to deal with ever-growing and -invading microorganisms in periodontal pockets, but also by genetic and/or environmental factors. However, our understanding of the pathogenesis in human periodontal diseases is limited by the lack of specific and sensitive tools or models to study the complex microbial challenges and their interactions with the host's immune system. Recent advances in cellular and molecular biology research have demonstrated the importance of the acquired immune system in fighting the virulent periodontal pathogens and in protecting the host from developing further devastating conditions in periodontal infections. The use of genetic knockout and immunodeficient mouse strains has shown that the acquired immune response, in particular, $CD4^+$ T-cells plays a pivotal role in controlling the ongoing infection, the immune/inflammatory responses, and the subsequent host's tissue destruction.

각종 의치상재료가 상악총의치의 유지에 미치는 영향에 관한 실험적 연구

  • 이언호
    • 대한치과의사협회지
    • /
    • 제12권9호
    • /
    • pp.667-677
    • /
    • 1974
  • A testing machine was devised and constructed for the purpose of measuring the retentive forces of maxillary complete denture bases in subjects. Forth complete denture bases were made for ten subjects with three different denture base materials, following the usual denture construction technique. Retentive forces of the forty dentures were determined at seven locations. The tests on each base were repeated three times at intervals of 5 minutes. Differences in retention values were evaluated statistically. 1) Differences in retention values were found by the differences of the denture base materials, but acrylic resin was similar to chromium cobalt alloy. 2) The chromium cobalt alloy and acrylic resin bases from master models revealed the best retention values, the gold alloy base from master model was the poor second and the acrylic resin base from snap model was the third. 3) The retention values for hook-1 revealed higher than that for hook-2 and the retention values for hook-3 revealed the lowest value.

  • PDF