• Title/Summary/Keyword: Degradation time

Search Result 2,830, Processing Time 0.03 seconds

Reliability Analysis of MLCC Degradation Data based on Eyring Model (아이링 모델에 기초한 MLCC 열화데이터의 신뢰성 해석)

  • 김종철;김광섭;차종범
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2004.07a
    • /
    • pp.239-246
    • /
    • 2004
  • Accelerated degradation test (ADT) can be a useful tool for assessing the reliability when few or even no failure are expected in an accelerated life test. In this paper, MLCC (Multilayer Ceramic Capacitors), a sort of passive components which have large capacitance(X7R -55$^{\circ}C$~1$25^{\circ}C$) have been tested, and least-square analyses are used to illustrate our approach in which amount of degradation of a DUT following log-normal distribution. We assumed a simple and useful linear model to describe the amount of degradation over time subjected to different voltage levels applied. Tests for linearity of the performance-time relationship, and provide tests for how well the assumptions hold. Also, by using Eyring Model, MLCC's mean life time is assessed.

  • PDF

Assessing the long-term durability and degradation of rocks under freezing-thawing cycles

  • Seyed Zanyar Seyed Mousavi;Mohammad Rezaei
    • Geomechanics and Engineering
    • /
    • v.34 no.1
    • /
    • pp.51-67
    • /
    • 2023
  • In this research, the degradation rate of physical properties of the Angouran pit bedrock (calc-schist) is first investigated under the specific numbers of freeze-thaw (F-T) cycles. Then, the durability of calc-schist specimens against the F-T cycle number (N) is examined considering the mechanical parameters, and using the decay function and half-time techniques. For this purpose, point load strength (IS(50)), second durability index (Id2), Brazilian tensile strength (BTS), and compressive (VP) and shear (VS) wave velocities of calc-schist specimens are measured after 0, 7, 15, 40, and 75 N. For comparing the degradation rate of mechanical properties of available rock types on the Angouran mine walls, these tests are also carried out on the limestone and amphibolite schist specimens beside the calc-schist. According to test results, the exponential regression models are developed between the mechanical parameters of rock specimen's and N variable. Also, the long-term durability of each rock type versus N is studied using the decay function and half-time techniques. Results indicated that the degradation rate differs for the above rock types in which amphibolite schist and calc-schist specimens have the highest and least resistance against the N, respectively. The obtained results from this study can play a key role in the optimal design of the mine's final walls.

A Comparison of the Experiment Results and the Radical Degradation Pathways in PCE through Atomic Charge Calculation

  • Lee, Byung-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.492-497
    • /
    • 2016
  • The intermediate product resulting from the radical degradation experiment of PCE and the atomic charge gained through Gaussian03W were compared against each other. The result was that the ratio of PCE radical degradation was almost 98% or higher after the 9 hr point in reaction time. The reaction speed constant was $0.16hr^{-1}$ and it followed the first reaction. We could see that at each location of the PCE molecule, dechlorination happened at a point where the negative atomic charge was the greatest. Moreover, the intermediate product of PCE radical degradation that was confirmed in the experiment and literature coincided exactly with the intermediate product in the atomic charge calculation. Therefore, when the atomic charge is calculated, the radical degradation pathway of the organic chlorine compound could be forecast.

DC Potential Drop Method for Evaluating Material Degradation

  • Seok, Chang-Sung;Bae, Bong-Kook;Koo, Jae-Mean
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.8
    • /
    • pp.1368-1374
    • /
    • 2004
  • The remaining life estimation for the aged components in power plants as well as chemical plants are very important because mechanical properties of the components are degraded with in-service exposure time in high temperatures. Since it is difficult to take specimens from the operating components to evaluate mechanical properties of components, nondestructive techniques are needed to evaluate the degradation. In this study, test materials with several different degradation levels were prepared by isothermal aging heat treatment at $630^{\circ}C$. The DC potential drop method and destructive methods such as tensile and fracture toughness were used in order to evaluate the degradation of 1Cr-1Mo-0.25V steels. In this result, we can see that tensile strength and fracture toughness can be calculated from resistivity and it is possible to evaluate material degradation using DC potential drop method, non-destructive method.

Planning Accelerated Degradation Tests: the Case of Gamma Degradation Process (열화가 감마과정을 따르는 경우 가속열화시험의 최적 계획)

  • Lim, Heonsang;Lim, Dae-Eun
    • Journal of Korean Society for Quality Management
    • /
    • v.43 no.2
    • /
    • pp.169-184
    • /
    • 2015
  • Purpose: This paper is concerned with optimally designing accelerated degradation test (ADT) plans based on a gamma process for the degradation model. Methods: By minimizing the asymptotic variance of the MLE of the q-th quantile of the lifetime distribution at the use condition, the test stress levels and the proportion of test units allocated to each stress level are optimally determined. Results: The optimal plans of ADT are developed for various combination of parameters. In addition, a method for determining the sample size is developed, and sensitivity analysis procedures are illustrated with an example. Conclusion: It is important to optimally design ADT based on a gamma process under the condition that a degradation process should be always nonnegative and strictly increasing over time.

Reliability Analysis of Degradation Data for LEDs (LED 열화데이터의 신뢰성 분석)

  • Park, Chang-Kyu
    • Journal of Applied Reliability
    • /
    • v.9 no.1
    • /
    • pp.59-69
    • /
    • 2009
  • LEDs have rapidly replaced old light devices such as incandescent or fluorescent lamps, and have been widely applied in general lighting, signals, automobile, signs and others. Since LEDs are for both indoor and outdoor use, temperature and humidity inevitably affect its reliability. We explain the result of the degradation life test on LEDs, and guide to reliability analysis procedure. Analysis on reliability measures are performed by Weibull++6 program, and a common shape parameter of Weibull distribution on the LED is suggested. Also, we make a description of reliability analysis procedures for the degradation data using collected test data from degradation tests. Reliability analysis procedures are consisted of estimating degradation models and failure time, verifying of distribution and parameters of the distribution, and estimating of reliability measures. Finally, this paper suggests reliability analysis method for light characteristics on LEDs.

  • PDF

Characteristics of Insulation Degradation in Epoxy Mold Type BCT (에폭시 몰드형 BCT의 절연열화 특성)

  • Song, Jae-Joo;Lee, Jung-Choi;Lim, Sung-Hun;Ko, Seok-Cheol;Han, Byung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.10
    • /
    • pp.902-908
    • /
    • 2005
  • Various stresses (such as electrical stress, mechanical stress, environmental and electrochemical stress, and defects of structure) result in insulation degradation of epoxy mold type insulators. Since the insulation degradation of BCT(Bushing Current Transformer) and bushing proceeds during fabrication process or operation time due to these causes, various methods to reduce the degradation in their insulation ability have been suggested. In this paper, we investigated surface temperature increment of these insulators due to PD(partial discharge). After the voltage applied into the insulator to generate the artificial PD, the surface temperature of the insulator was measured with non-contact thermometer using infrared rays. It was confirmed through the analysis based on PD experiments that the procession in the insulation degradation of the insulator could be estimated through the measurement of the surface temperature in the insulator.

Interaction of Oxygen and Chlorine Dioxide in Pulp Bleaching (I) -Studies on the Degradation of Lignin Model Compounds- (펄프 표백시 산소와 이산화염소의 상호작용 (제1보) - 리그닌 모델화합물 연구 -)

  • 윤병호;황병호;김세종;최경화
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.35 no.3
    • /
    • pp.74-78
    • /
    • 2003
  • The structural property of phenolic and non-phenolic lignin has an effect on the reaction rate of lignin by oxygen and chlorine dioxide respectively. Moreover, the undesirable degradation of cellulose followed by lignin degradation is influenced by chemical charge and reaction time. In this paper, several lignin model compounds were used to illuminate the interaction of oxygen and chlorine dioxide by varying the position of O and D(OD, DO, ODO and DOD), and gas chromatography method was used to investigate the degradation of lignin by determining the content of methoxyl groups in lignin. It was shown that structural properties of lignin models were more influential on the degradation and demethylation of lignin than the above combination. Combination of oxygen and chlorine dioxide, however, was more effective in degradation of lignin than only one stage, and three stages than two stages.

Fundamental Study on the Photocatalytic Degradation of Organics in Industrial Waste Water with the Presence of Titanium Dioxide

  • Kusaka, Eishi;Izawa, Mihiro;Fukunaka, Yasuhiro;Ishii, Ryuji
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.286-291
    • /
    • 2001
  • As part of fundamental studies on the degradation of the organic compounds in industrial waste water, the photocatalytic degradation properties of the organic compound by means of the UV/TiO$_2$degradation process have been investigated. The test organic compound of acetic acid was chosen in this study. The testing of photo catalytic degradation were performed under various operation conditions such as TiO$_2$dosages, initial concentration of the organic, the aqueous pH's, etc. The effects of various parameters on the short time activity of the present acetic acid-UV/TiO$_2$system could be demonstrated from this investigation.

  • PDF

Reliability Assessment of Anticorrosive Paints with Accelerated Degradation Test (가속열화시험에 의한 건축용 도료의 신뢰성 평가)

  • Kwon, Young-Il;Kim, Seung-Jin
    • Journal of Applied Reliability
    • /
    • v.9 no.4
    • /
    • pp.291-302
    • /
    • 2009
  • Accelerated and field degradation tests are performed for reliability assessment of an anticorrosive paint for steel structures. Test data were analyzed to obtain the degradation model and the life time distributions of the paint. A power law degradation model and lognormal performance distribution were used to predict the lifetime of the anticorrosive paint and the method of finding an acceleration factor is provided.

  • PDF