• 제목/요약/키워드: Defect length

검색결과 399건 처리시간 0.024초

Recurrence plot entropy for machine defect severity assessment

  • Yan, Ruqiang;Qian, Yuning;Huang, Zhoudi;Gao, Robert X.
    • Smart Structures and Systems
    • /
    • 제11권3호
    • /
    • pp.299-314
    • /
    • 2013
  • This paper presents a nonlinear time series analysis technique for evaluating machine defect severity, based on the Recurrence Plot (RP) entropy. The RP entropy is calculated from the probability distribution of the diagonal line length in the recurrence plot, which graphically depicts a system's dynamics and provides a global picture of the autocorrelation in a time series over all available time-scales. Results of experimental studies conducted on a spindle-bearing test bed have demonstrated that, as the working condition of the bearing deteriorates due to the initiation and/or progression of structural damages, the frequency information contained in the vibration signal becomes increasingly complex, leading to the increase of the RP entropy. As a result, RP entropy can serve as an effective indicator for defect severity assessment of rolling bearings.

알루미늄 합금재의 피로크랙 전파거동에 미치는 미소원공결함 (The Influence of the Small Circular Hole Defect on the Fatigue Crack Propagation Behavior in Aluminum Alloys)

  • 김건호;이호연
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.834-840
    • /
    • 2008
  • We carried out fatigue testing with materials of aluminum alloyC7075-T6, 2024-T4) by rotary bending fatigue tester. We investigated fatigue limit, fatigue crack initiation, fatigue crack propagation behavior and possibility of fatigue life prediction to the different small circular hole defect. The summarized result are as follows; Fatigue limit of the smooth specimens were related tensile strength and yield strength. In case of more large applied stress and small circular hole crack defect, the fatigue crack was grown rapidly. The fatigue crack propagation behavior proceed at according to inclusion. Fatigue crack propagation ratio appeared instability and retardation phenomenon in the first half of fatigue life but appeared stability and replied in the latter half. On other hand, this experimental data of the materials are appeared fatigue life predictability.

강자성체 평판의 자속 누설 탐상 비파괴 실험 및 수치해석 (Non-destructive Testing and Numerical Analysis for Ferromagnetic Plates using Magnetic Flux Leakage Method)

  • 김신;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.126-128
    • /
    • 2001
  • In this paper, Magnetic Flux Leakage(MFL) method is used to detect surface defect in ferromagnetic plate. Surface defects are created on the SM 45C ferromagnetic plate and magnetizing equipment is composed to perform MFL nondestructive testing. The length and width of defect is twice the thickness of ferromagnetic plate, and defects with different depths are made artificially for the experiment. Also, NdFeB magnet in magnetizing equipment is used to make magnetic flux. This paper shows that it is possibile to detect 10% defect and to analyze numerically for any defect using MFL method.

  • PDF

엘보우의 붕괴모멘트에 미치는 국부 감육결함의 영향 (Effect of Local Wall Thinning Defect on the Collapse Moment of Elbow)

  • 김진원;김태순;박치용
    • 대한기계학회논문집A
    • /
    • 제28권4호
    • /
    • pp.402-409
    • /
    • 2004
  • The purpose of this study is to investigate the effect of local wall thinning on the collapse of elbow subjected to internal pressure and bending moment. Thus, the nonlinear three-dimensional finite element analyses were performed to obtain the collapse moment of elbow containing various wall thinning defects located at intrados and extrados under two loading modes (closing and opening modes) with internal pressure. From the results of analysis, the effect of wall thinning defect on the global moment-rotation behavior of elbow was discussed, and the dependence of collapse moment of elbow on wall thinning depth, length, and circumferential angle was investigated under different loading mode and defect location.

관절와에 작은 골결손을 가진 외상성 전방 불안정 견관절의 관절경적 봉합 치료 (Arthroscopic Repair of Traumatic Anterior Shoulder Instability with Small Glenoid Bone Defect)

  • 구본섭;정화재
    • Clinics in Shoulder and Elbow
    • /
    • 제7권2호
    • /
    • pp.70-75
    • /
    • 2004
  • Purpose: To evaluate the results of arthroscopic repair of traumatic anterior shoulder instability with glenoid bone defect. Materials and Methods: Nineteen patients who had underwent arthroscopic repair for the shoulder with traumatic anterior instability and glenoid bone defect were retrospectively reviewed. Mean age was 24.6 years(range, 20 to 39) and mean follow-up was 23 months(range, 19 to 55). No glenoid bone defect was greater than 7mm in length and 20% of the glenoid. The results were evaluated according to stability, range of motion and function. Results: All patients obtained excellent-good results according to Rowe scoring system. Two patients(10.5%) had instability. The mean loss of external rotation was 15 degrees (range, 0 to 25). Functionally, 17 patients could participate in preinjured work or sports to the same level with or without mild discomfort. The remained 2 patients who had 25 degree loss of external rotation could not play sports. Conclusion: Though arthroscopic repair is a good treatment for traumatic anterior shoulder instability with small glenoid bone defect, it is possible to cause loss of external rotation

기어박스에서의 베어링 결함 진단 (Bearing Fault Diagnostics in a Gearbox)

  • 김흥섭;이상권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.611-616
    • /
    • 2002
  • Bearing diagnostics is difficult in a gearbox because bearing signals are masked by the strong gear signals. Self adaptive noise cancellation(SANC) is useful technique to seperate bearing signals from gear signals. While gear signals are correlated with a long correlation length, bearing signals are not correlated with a short length. SANC seperates two components on the basis of correlation length. Then we can find defect frequency component in the envelope spectrum of the bearing signals.

  • PDF

Anomalous Subthreshold Characteristics of Shallow Trench-Isolated Submicron NMOSFET with Capped p-TEOS/SiN

  • Lee, Hyung J.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권3호
    • /
    • pp.18-20
    • /
    • 2002
  • In sub-l/4 ${\mu}{\textrm}{m}$ NMOSFET with STI (Shallow Trench Isolation), the anomalous hump phenomenon of subthreshold region, due to capped p-TEOS/SiN induced defect, is reported. The hump effect was significantly observed as channel length is reduced, which is completely different from previous reports. Channel boron dopant redistribution due to the defect should be considered to improve hump characteristics besides considerations of STI comer and recess. 130

미세 탐침의 비전 자동 검사 시스템 개발 (Development of Automatic Visual Inspection System for Micro Needle)

  • 강수민;한광희;허경무
    • 전자공학회논문지SC
    • /
    • 제45권6호
    • /
    • pp.16-25
    • /
    • 2008
  • 미세 탐침이란 프로브 카드(Probe Card)를 구성하는 초미세탐침을 의미한다. 이러한 미세 탐침은 그 크기가 상당히 미세하기 때문에 외관 이상 유무를 사람의 눈으로 검사하기가 상당히 어렵다. 반면, 프로브카드를 구성하는 미세 탐침의 이상 유무는 상당히 중요한 요소라고 볼 수 있다. 이에 본 연구에서는 사람의 눈으로 검사하기 어려운 미세 탐침의 불량 상태를 자동화된 비전 시스템으로 검사할 수 있는 방법을 개발하였다. 즉 탐침의 구부러진 각도, Tip Length, 종단 직경을 고속으로 자동 검사할 수 있는 비전 기술을 개발한 것이다 제안한 방법에 의한 실험결과, 사람의 육안에 위한 검사보다 검사의 정확도와 속도가 향상되었으며, 또한 조명환경에 대해서도 강건성(robustness)이 향상되었음을 알 수 있었다.

연부조직 결손을 동반한 감염성 경골 불유합 및 골결손의 치료(유리피판술과 동시에 시행한 Ilizarov기구를 이용한 골연장술의 유용성) (Treatment of Infected Tibial Nonunion Combined with Soft Tissue Defect (Effectiveness of Simultaneous Free-tissue Transfer and Ilizarov Distraction Osteogenesis))

  • 송준영;정현균;서승용;장현호
    • Archives of Reconstructive Microsurgery
    • /
    • 제14권1호
    • /
    • pp.37-41
    • /
    • 2005
  • Purpose: The purpose of this study was to evaluate the effectiveness of internal transport using Ilizarov apparatus with free flap surgery for infected tibial nonunion. Materials and Methods: We reviewed 8 patients of infected tibial nonunion treated with internal transport using Ilizarov apparatus and free flap surgery. Seven of eight patients were available for at least 1 year follow-up. All patients were male. The mean age at the time of the surgery was All fractures were Gustilo's type III B open fracture. The mean length of the bone defect was 8.5 cm. All used flaps for covering the soft tissue defect were free rectus abdominis muscle flap. We evaluated bone and functional results with use of the Paley and Catagni's classification. And we classified the complication with use of the Paley's classification. Results: Acceptable length and solid union of bone was achieved in all cases. The mean size of the bone length was 7.2 cm. The mean healing index was 69.5 days/cm. All but one case needed bone graft at docking site. All flaps were survived. There was no recurrence of infection. According to Paley and Catagni's classification, all cases showed excellent or good results. Complications were pin tract infection in 3 cases, persistent pain in 2 cases and limitation of joint motion in 2 cases. Conclusion: Simultaneous free-tissue transfer and Ilizarov distraction osteogenesis was thought to be an attractive treatment modality for infected nonunion of the tibia.

  • PDF

증기발생기 전열관 2차측 응력부식균열의 실험실적 모사 방법 (Laboratorial technique for fabrication of outer diameter stress corrosion cracking on steam generator tubing)

  • 이재민;김성우;황성식;김홍표;김홍덕
    • Corrosion Science and Technology
    • /
    • 제13권3호
    • /
    • pp.112-119
    • /
    • 2014
  • In this work, it is aimed to develop the fabrication method of axial stress corrosion cracking (SCC) defects having various sizes, on the outer diameter surface of the steam generator (SG) tubings. To control the length of the artificial SCC defect, the specific area of the SG tubing samples was exposed to an acidic solution after a sensitization heat treatment. During the exposure to an acidic solution, a direct current potential drop (DCPD) method was adopted to monitor the crack depth. The size of the SCC defect was first evaluated by an eddy current test (ECT), and then confirmed by a destructive examination. From the comparison, it was found that the actual crack length was well controlled to be similar to the length of the surface exposed to an acidic solution (5, 10, 20 or 30 mm in this work) with small standard deviation. From in-situ monitoring of the crack depth using the DCPD method, it was possible to distinguish a non-through wall crack from a through wall crack, even though the depth of the non-through wall crack was not able to be precisely controlled. The fabrication method established in this work was useful to simulate the SCC defect having similar size and ECT signals as compared to the field cracks in the SG tubings of the operating Korean PWRs.