• 제목/요약/키워드: Defect control

검색결과 863건 처리시간 0.032초

Effect of Brush Treatment and Brush Contact Sequence on Cross Contaminated Defects during CMP in-situ Cleaning

  • Kim, Hong Jin
    • Tribology and Lubricants
    • /
    • 제31권6호
    • /
    • pp.239-244
    • /
    • 2015
  • Chemical mechanical polishing (CMP) is one of the most important processes for enabling sub-14 nm semiconductor manufacturing. Moreover, post-CMP defect control is a key process parameter for the purpose of yield enhancement and device reliability. Due to the complexity of device with sub-14 nm node structure, CMP-induced defects need to be fixed in the CMP in-situ cleaning module instead of during post ex-situ wet cleaning. Therefore, post-CMP in-situ cleaning optimization and cleaning efficiency improvement play a pivotal role in post-CMP defect control. CMP in-situ cleaning module normally consists of megasonic and brush scrubber processes. And there has been an increasing effort for the optimization of cleaning chemistry and brush scrubber cleaning in the CMP cleaning module. Although there have been many studies conducted on improving particle removal efficiency by brush cleaning, these studies do not consider the effects of brush contamination. Depending on the process condition and brush condition, brush cross contamination effects significantly influence post-CMP cleaning defects. This study investigates brush cross contamination effects in the CMP in-situ cleaning module by conducting experiments using 300mm tetraethyl orthosilicate (TEOS) blanket wafers. This study also explores brush pre-treatment in the CMP tool and proposes recipe effects, and critical process parameters for optimized CMP in-situ cleaning process through experimental results.

Influence of biodegradable polymer membrane on new bone formation and biodegradation of biphasic bone substitutes: an animal mandibular defect model study

  • Ku, Jeong-Kui;Kim, Young-Kyun;Yun, Pil-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.34.1-34.7
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the influence of biodegradable polycaprolactone membrane on new bone formation and the biodegradation of biphasic alloplastic bone substitutes using animal models. Materials and methods: In this study, bony defect was formed at the canine mandible of 8 mm in diameter, and the defects were filled with Osteon II. The experimental groups were covered with Osteoguide as barrier membrane, and the control groups were closed without membrane coverage. The proportion of new bone and residual bone graft material was measured histologically and histomorphometrically at postoperative 4 and 8 weeks. Results: At 4 weeks, the new bone proportion was similar between the groups. The proportion of remaining graft volume was 27.58 ± 6.26 and 20.01 ± 4.68% on control and experimental groups, respectively (P < 0.05). There was no significant difference between the two groups in new bone formation and the amount of residual bone graft material at 8 weeks. Conclusion: The biopolymer membrane contributes to early biodegradation of biphasic bone substitutes in the jaw defect but it does not affect the bone formation capacity of the bone graft.

Development of Inspect Algorithm for Pallets Using Vision System

  • Lee, Man-Hyung;Hong, Suh-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.101.6-101
    • /
    • 2001
  • This paper deals with inspect algorithm using visual system. One of the major problems that arise during polymer production is the estimation of the noise of the product(bad pallets). An erroneous output can cause a lot of losses (production and financial losses). Therefore new methods for real-time inspection of the noise are demanded. For this reason, we have presented a development of vision system algorithm for the defect inspection of PE pallets. First of all, in order to detect the edge of object, the differential filter is used. And we apply to the labeling algorithm for feature extraction. This algorithm is designed for the defect inspection of pallets ...

  • PDF

Are critical size bone notch defects possible in the rabbit mandible?

  • Carlisle, Patricia L.;Guda, Teja;Silliman, David T.;Hale, Robert G.;Baer, Pamela R. Brown
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권2호
    • /
    • pp.97-107
    • /
    • 2019
  • Objectives: Small animal maxillofacial models, such as non-segmental critical size defects (CSDs) in the rabbit mandible, need to be standardized for use as preclinical models of bone regeneration to mimic clinical conditions such as maxillofacial trauma. The objective of this study is the establishment of a mechanically competent CSD model in the rabbit mandible to allow standardized evaluation of bone regeneration therapies. Materials and Methods: Three sizes of bony defect were generated in the mandibular body of rabbit hemi-mandibles: $12mm{\times}5mm$, $12mm{\times}8mm$, and $15mm{\times}10mm$. The hemi-mandibles were tested to failure in 3-point flexure. The $12mm{\times}5mm$ defect was then chosen for the defect size created in the mandibles of 26 rabbits with or without cautery of the defect margins and bone regeneration was assessed after 6 and 12 weeks. Regenerated bone density and volume were evaluated using radiography, micro-computed tomography, and histology. Results: Flexural strength of the $12mm{\times}5mm$ defect was similar to its contralateral; whereas the $12mm{\times}8mm$ and $15mm{\times}10mm$ groups carried significantly less load than their respective contralaterals (P<0.05). This demonstrated that the $12mm{\times}5mm$ defect did not significantly compromise mandibular mechanical integrity. Significantly less (P<0.05) bone was regenerated at 6 weeks in cauterized defect margins compared to controls without cautery. After 12 weeks, the bone volume of the group with cautery increased to that of the control without cautery after 6 weeks. Conclusion: An empty defect size of $12mm{\times}5mm$ in the rabbit mandibular model maintains sufficient mechanical stability to not require additional stabilization. However, this defect size allows for bone regeneration across the defect. Cautery of the defect only delays regeneration by 6 weeks suggesting that the performance of bone graft materials in mandibular defects of this size should be considered with caution.

백서의 두개골 결손 모델에 있어 지방유래 줄기세포가 탈회골의 골유도에 미치는 영향 (Effect of Murine Adipose Derived Stem Cell(ADSC) on Bone Induction of Demineralized Bone Matrix(DBM) in a Rat Calvarian Defect Model)

  • 허찬영;이은혜;서석진;은석찬;장학;백롱민;민경원
    • Archives of Plastic Surgery
    • /
    • 제35권6호
    • /
    • pp.631-636
    • /
    • 2008
  • Purpose: Adipose tissue-derived stem cells(ADSC) has an osteoconductive potential and demineralized bone matrix(DBM) is an osteoinductive material. A combination of DBM and ADSC wound probably create osteoinductive properties. The purpose of this study is to determine the effect of the combination of DBM and ADSC mixture on healing of rat calvarial defect. Methods: Thirty adult male Sprague-Dawley rats were randomized into 3 groups(n=10) as 1) Control, 2) DBM alone, 3) DBM with ADSC mixture. DBM with ADSC mixture group has had a 3-day preculture of ADSC from groin fat pad. An 6 mm critical size circular calvarial defect was made in each rat. Defect was implanted with DBM alone or DBM with ADSC mixture. Control defect was left unfilled. 6 and 12 weeks after the implantation, the rats were sacrificed and the defects were evaluated by histomorphometric and radiographical studies. Results: Histomorphometric analysis revealed that DBM with ADSC mixture group showed significantly higher bone formation than DBM alone group(p<0.05). Although radiographs from DBM alone group and DBM with ADSC group revealed similar diffuse radiopaque spots dispersed throughout the defect. Densitometric analysis of calvarial defect revealed DBM with ADSC mixture group significantly higher bone formation than DBM alone(p<0.05). There was correlation of densitometry with new bone formation(Spearman's correlation of coefficient=0.804, 6 weeks, 0.802, 12 weeks). Conclusion: The DBM with ADSC mixture group showed the best healing response and the osteoinductive properties of DBM were accelerated with ADSC mixture. It will be clinically applicable that DBM and ADSC mixture in plastic and reconstructive surgery, such as alveolar cleft and congenital facial deformities that bone graft should be required.

LiF-maleic acid 첨가 calcium aluminate 골시멘트 및 CA-PMMA 복합 골시멘트가 백서 두개골 결손부 치유에 미치는 영향 (The effect of LiF-maleic acid added calcium aluminate hone cement & CA-PMMA composite bone cement on the healing of calvarial defect6))

  • 신정아;윤정호;오승한;백정원;최세영;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제32권4호
    • /
    • pp.753-767
    • /
    • 2002
  • The purpose of this study was to evaluate histologically the effect of LiF-maleic acid added calcium aluminate(LM-CA) bone cement & CA-PMMA composite bone cement on the healing of calvarial defect in Sprague-Dawley rats. The critical size defects were surgically produced in the calvarial bone using the 8mm trephine bur. The rats were divided in three groups : In the control group, nothing was applied into the defect of each rat. LM-CA bone cement was implanted in the experimental group 1 and CA-PMMA composite bone cement was implanted in the experimental group 2. Rats were sacrificed at 2, 8 weeks after surgical procedure. The specimens were examined by histologic analysis, especially about the bone-cement interface and the response of surrounding tissue. The results are as follows; 1. In the control group, inflammatory infiltration was observed at 2 weeks. At 8 weeks, periosteum and duramater were continuously joined together in the defect area. But the center of defect area was filled up with the loose connective tissue. 2. In the experimental group 1, the bonding between implanted bone cement and the existing bone was seen, which more increased in 8 weeks than 2 weeks. Inflammatory infiltration and the dispersion of implanted bone cement particles were seen in both 2 weeks and 8 weeks. 3. In the experimental group 2, implanted bone itself had a dimensional stability and no bonding between implanted bone cement and the existing bone was seen in both 2 weeks and 8 weeks. Implanted bone cement was encapsulated by fibrous connective tissue. In addition, inflammatory infiltration was seen around implanted bone cement. On the basis of these results, when LM-CA bone cement or CA-PMMA composite bone cement was implanted in rat calvarial defect, LM-CA bone cement can be used as a bioactive bone graft material due to ability of bonding to the existing bone and CA-PMMA can be used as a graft material for augmentation of bone-volume due to dimensional stability.

소방펌프의 운전상태에 따른 유도전동기의 이상 신호 분석 (Analysis of Abnormal Signals for Induction Motor according to Operating Status of Fire Pumps)

  • 구본휴;김두현;김성철
    • 한국안전학회지
    • /
    • 제37권4호
    • /
    • pp.20-27
    • /
    • 2022
  • This article aims to develop an algorithm that detects fire pump defects by analyzing the current signals of an induction motor, which are triggered by changes in the flow rate and pressure of multistage volute pumps that are used for fire services. The operational status of the pumps was categorized into three: first, normal operation; second, a defect that is caused by a change in the current value; and third, a defect occasioned by a change in current, pressure, and flow rate. When a fire pump was in normal operation, the motor's operating current was measured between 5.06 A and 6.9 A, the flow rate was estimated at 0-0.27 m3/min, and the pressure ranged from 0 to 0.47 MPa. In the event that a defect was caused by an abnormal current value in the motor, it was attributed to the pump's adherence. Furthermore, if there was no source of water, the defect was considered to have been induced by phase-loss operation, no-load operation, or run-stop operation, with the current value of each scenario being measured at > 52.8 A, < 4.13 A, > 45.15 A, and < 3.8 A, respectively, placing its overall range between 0 and 50 A. The sources of defects were detected based on an analysis of the flow rate, pressure, and current, which represent the following causes: air inflow into the casing, inadequate suction of water, and reverse-phase operation, respectively. Each cause entailed the following values: when air seeped into the casing, the pressure was measured at 0.24 MPa irrespective of changes in the flow rate; when there was inadequate suction of water, the pressure was recorded between 0 and 0.05 MPa despite changes in the flow rate; and when the power line's reverse-phase loss was the cause of the defect, the pressure was measured at 0.33 MPa for a flow rate of 0 L/min, and a higher flow rate decreased the pressure to nearly 0 MPa. The results of this study will enable engineers to develop a pump defect detection algorithm that is based on an analysis of current, and this algorithm will facilitate the execution of a program that will control a fire pump defect detection system.

Turn signal lamp jacket to prevent accident of bicycles

  • Saxena, Tarika
    • 한국인공지능학회지
    • /
    • 제4권1호
    • /
    • pp.4-7
    • /
    • 2016
  • These days, citizens have made change of food life to take Western style food and to suffer from diabetes because of excessive nutrition taking, less exercise, stress and other environmental factors. They may suffer from diabetes because of genetic defect, surgery of pancreas, disinfection and medicine and others. One of ten Koreans may have symptom of diabetes to be popular. The diabetes that is a kind of metabolic disease has high blood sugar at disorder of hyper insulinism and/or defect of insulin action. Long time high blood sugar may produce chronic disease of kidney, eyes, nerve, heart and blood vessel and others. The purpose of health care of diabetes patient was to reach target blood sugar by diet, physical exercise and medicine and to prevent and delay complication. Diabetes patient shall control blood sugar to keep healthy. The blood sugar control requires time and effort, and all of the patients are difficult to make effort and to spend time. You can control blood sugar by the application. The application allows patients to control blood sugar and to save time and efforts and to make small sized input and automation of remaining area. The service was limited to blood sugar graph, and user carries smart phone to conduct test and to have difficulty. Further study needs to solve the problems and to investigate blood sugar testing not carrying smart phone and to make application of easy control of blood sugar.

치근단 수출 시 형성된 골결손 부위를 가진 치아의 발치 후 즉시 식립 임플란트에서 골 접촉률에 대한 흡수성 차폐막의 효과 (Effect of resorbable membrane on immediate placement of implant in extraction socket during periradicular surgery)

  • 양승민;계승범;신승윤
    • Journal of Periodontal and Implant Science
    • /
    • 제38권4호
    • /
    • pp.603-610
    • /
    • 2008
  • Purpose: The guided bone regeneration (GBR) technique is widely used in periradicular surgery. However, there is still some controversy regarding the effectiveness of GBR in promoting bone healing after periradicular surgery. The purpose of this study was to evaluate the resorbable membrane on the osteointegration of immediate implants in sites with periradicular lesion that had been removed by periradicular surgery. Materials and methods: Six roots of lower second premolars and 15 roots of lower third and fourth premolars of dogs were used as control and experimental teeth, respectively. Periradicular lesions were induced only in the experimental teeth. Twelve weeks later, the control and experimental teeth were extracted and implants were placed immediately. Periradicular lesions were removed with osteotomy, curettage and saline irrigation. Resorbable membranes were used in experimental group 1 but not in experimental group 2. After 12 week of healing period, the implants were clinically not mobile and showed no signs of infection. Data obtained by histomorphometric analysis were analyzed by Kruskal-Wallis test. Results: The control group showed a significantly higher bone to implant contact (BIC) ($74.14{\pm}16.18$) than experimental group 1 ($40.28{\pm}15.96$) and 2 ($48.70{\pm}17.75$)(p<0.05). However, there was no significant difference between experimental group 1 and 2. Conclusion: Although BIC in experimental groups were lower than in control group, immediate implant can be successfully placed at extraction socket with periradicular lesion and osseous defect. However, the use of resorbable membrane in bony defect created during periradicular surgery was questioned.

가토 두개골 결손부 모델에서 테트라사이클린 함유 실크 파이브로인 차폐막의 골유도 재생 효과 (The Effects of Tetracycline-loaded Silk Fibroin Membrane on Guided Bone Regeneration in a Rabbit Calvarial Defect Model)

  • 이상운;박용태;김성곤;권해용;조유영;이희삼
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권5호
    • /
    • pp.293-298
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the bone regeneration ability of 1% tetracycline (TC)-loaded silk fibroin membrane (SFM), in a rabbit calvarial defect model. Methods: Twenty New Zealand white rabbits were used for this study. Bilateral round defects were made on the rabbit parietal bone, using trephine bur with an 8 mm diameter. TC-loaded SFM or SFM was covered on the right parietal bone defect, and the left parietal bone defects were uncovered for the control. The animals were humanely sacrificed at 4 or 8 weeks postoperatively. A micro-computerized tomography (${\mu}$-CT) of each specimen was taken for analysis of bone regeneration. Hematoxylin and Eosin stain were done to observe histological findings. Results: From the ${\mu}$-CT results, regenerated bone volume ($mm^3$) of 1% TC-loaded SFM, SFM, and control were $7.80{\pm}5.87$, $8.79{\pm}3.44$, and $10.61{\pm}5.3$ at 4 weeks postoperatively, respectively (P>0.05). Regenerated bone volume ($mm^3$) of 1% TC-loaded SFM, SFM, and control were $36.56{\pm}8.50$, $25.86{\pm}8.17$, and $19.09{\pm}5.07$ at 8 weeks postoperatively, respectively (P<0.05). Conclusion: The 1% TC-loaded SFM showed more bone regeneration than the SFM and the uncovered control, in guided bone regeneration.