• 제목/요약/키워드: Dead-Time Control

검색결과 332건 처리시간 0.04초

Analysis and Compensation Control of Dead-Time Effect on Space Vector PWM

  • Shi, Jie;Li, Shihua
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.431-442
    • /
    • 2015
  • Dead-time element must be set into space vector pulsed width modulation signals to avoid short circuits of the inverter. However, the dead-time element distorts the output voltage vector, which deteriorates the performance of electrical machine drive system. In this paper, dead-time effect and its compensation control strategy are analyzed. Based on the analysis, the voltage distortion caused by dead-time is regarded as two disturbances imposed on dq axes in the rotor reference frame, which degenerates the current tracking performance. To inhibit the adverse effect caused by the dead-time, a control scheme using two linear extended state observers is proposed. This method provides a strong ability to suppress dead-time effects. Simulations and experiments are conducted on a permanent magnet synchronous motor drive system to demonstrate the effectiveness of the proposed method.

인버터 출력 전류제어를 위한 새로운 스위칭 방법 (A New Switching Strategy for The Output Current Control of Inverters)

  • 인치각;오원석;조규민;유완식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.375-377
    • /
    • 1999
  • It is necessary to obtain the high performance of the inverter system that control the output current of inverters. The dead time causes detrimental effects to the control performance of the inverter system. So we need to compensate the dead time effects. And the dead time minimization switching method can be considered as the best way to avoid the dead time effects fundamentally. In this paper, a new dead time minimization switching strategy is proposed. According to the proposed method, very short dead time is adopted in only once when the current polarity is changing. And the adopted dead time is equal to the applied dead time or shorter than it. As the proposed method can be done with the porlarity information of the reference current. it is easy to avoid some problems in comparison with the case that the real current is used to get the polarity changing time; level detection difficulty, noise problem and so on.

  • PDF

시간지연 제어기법을 이용한 새로운 데드 타임 보상법 (A New Dead-Time Compenstion Method using Time Delay Control Approach)

  • 김현수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.425-428
    • /
    • 2000
  • A new dead time compensation method using time delay control approach is presented. The dead time in switching pattern cause the voltage distortion and it can be considered as the disturbance voltage. In this paper the disturbance voltage is estimated using time delay control and the estimated disturbance voltage is summed with voltage command in predictive current control by a feed-forward. The proposed scheme is implemented on a PMSM and the effectiveness is verified through comparative simulation.

  • PDF

안정적 고반복을 위한 지연시간 제어회로가 적용된 커패시터 충전용 전원장치 (A Capacitor Charging Power Supply(CCPS) using Dead Time Control Circuit for Stable High Repetition)

  • 임태현;황선묵;국정현;임동우
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.55-60
    • /
    • 2017
  • Capacitor Charging Power Supply(CCPS) is one of the most important components of a pulsed power system. The CCPS is widely used in source of lasers, accelerators and plasma generators. This paper presents design of a dead time control circuit and operation characteristics for stable high repetition rate of high voltage CCPS. The CCPS consists of battery, high voltage transformer and controller with a dead time control circuit. A dead time control circuit was simulated by PSpice. The performance test of the CCPS was carried out with a 7[nF] load capacitor at output voltage of 50[kV] and a pulse repetition frequency of 100[Hz]. As a result, we can verify that charging and discharging waveform is stable at 100[Hz]. The experiment results indicate that 3[ms] dead time made it possible for stable high repetition rate of 100[Hz]. This paper paves the way for designing an advanced CCPS which is more applicable outside experiments.

일반화된 예측제어에 의한 가압경수형 원자로의 부하추종 출력제어에 관한 연구 (Generalized predictive control of P.W.R. nuclear power plant)

  • 천희영;박귀태;이종렬;박영환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.663-668
    • /
    • 1990
  • This paper deals with the application of a Generalized Predictive Control (CPC) to a Pressurized Water Reactor (P.W.R) Nuclear Power Plant. Generalized Predictive Control is a sort of Explicit Self-Tuning Control. Current self-tuning algorithms lack robustness to prior choices of either dead-time (input time delay of a plant) or model order. GPC is shown by simulation studies to be superior to accepted self-tuning techniques such as minimum variance and pole-placement from the viewpoint that it is robust to prior choices of dead-time or model order. In this paper a GPC controller is designed to control the P.W.R. nuclear power rlant with varying dead-time and through the designing procedure the designer is free from the constraint of knowing the exact dead-time. The controller is constructed based on the 2nd order linear model approximated in the vicinity of operating point. To ensure that this low-order model describes the complex real dynamics well enough for control purposes, model parameters are updated on-line with a Recursive Least Squares algorithm. Simulation results are successful and show the possibilities of the GPC control application to actual plants with varying or unknown dead-time.

  • PDF

Continued Fraction Expansion을 이용한 Dead Time 근사의 새로운 접근 (New Approach Using the Continued Fraction Expansion for the Dead Time Approximation)

  • 조원휘;이지태
    • Korean Chemical Engineering Research
    • /
    • 제50권5호
    • /
    • pp.830-836
    • /
    • 2012
  • Dead time은 공정의 동특성을 기술할 때 매우 자주 나타나는 것으로 공정의 동특성 모사 혹은 제어 시스템 분석에 많은 어려움을 준다. 이 어려움을 줄이기 위해 무한 차원의 dead time을 유한 차원의 전달함수로의 근사가 필요한데, 여기에는 Pade 근사가 자주 사용된다. Dead time의 정밀한 근사를 위해서는 고차의 Pade 근사가 필요한데, 고차의 Pade 근사식은 외우기 쉽지 않고 수치적으로 안정적이지 못하다. 이 Pade 근사와 같은 전달함수를 주지만 수치적으로 우수한 continued fraction 전개를 이용하는 방법을 제안하고자 한다. 제안하는 방법은 수치적으로 우수할 뿐만 아니라 매우 체계적이어서 쉽게 기억할 수 있어 공정제어 강의와 계산에 편리하게 이용할 수 있을 것이다.

Dead-Time 적응제어 기능을 갖는 PWM CMOS DC-DC 부스트 변환기 (PWM CMOS DC-DC Boost Converter with Adaptive Dead-Time Control)

  • 황인호;윤은정;박종태;유종근
    • 전기전자학회논문지
    • /
    • 제16권3호
    • /
    • pp.203-210
    • /
    • 2012
  • 기존의 DC-DC 부스트 변환기에 사용되는 non-overlapping gate driver는 dead-time이 고정되어 있기 때문에 body-diode conduction loss 또는 charge-sharing loss가 발생하는 문제점을 가지고 있다. 이러한 loss에 의한 효율 감소를 줄이기 위해 본 논문에서는 dead-time 적응제어 기능을 갖는 PWM DC-DC 부스트 변환기를 설계하였다. 제안된 DC-DC 부스트 변환기는 CMOS $0.35{\mu}m$ 공정으로 설계되었고, 입력전압 2.5V를 받아서 3.3V의 출력전압으로 승압시킨다. 스위칭 주파수는 500kHz이며, 최대효율은 97.3%이다.

승산 불확실성을 가지는 시간 지연 시스템의 제어기 설계 방법 (The design method of dead-time compensator for processes with multiplicative uncertainty and long dead time)

  • 김인희;마진석;최병태;김우현;구본호;권우현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.237-237
    • /
    • 2000
  • In this paper, The modified dead-time compensator for plants with an integrator and long dead time is proposed. The design procedure takes account of the closed-loop performance and robustness. The tuning of the controller can be done using some information about the plant and its uncertainties. The proposed controller is compared to others recently presented in the literature. Some simulation results verify good closed-performance and robustness of the proposed DTC.

MRAC 기법과 좌표변환을 이용한 PWM 인버터 구동 PMSM의 데드타임 보상기법 (Dead Time Compensation Scheme for a PWM Inverter-fed PMSM Drive Using MRAC Scheme and Coordinate Transformation)

  • 김경화
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.29-37
    • /
    • 2012
  • A simple and effective dead time compensation scheme for a PWM inverter-fed permanent magnet synchronous motor (PMSM) drive using the model reference adaptive control (MRAC) and coordinate transformation is presented. The basic concept is to first transform a time-varying disturbance caused by the dead time and inverter nonlinearity into unknown constant or slowly-varying one by the coordinate transformation, and then use the MRAC design technique to estimate this parameter in the stationary reference frame. Since the MRAC scheme is a suitable way of estimating such a parameter, the control performance can be significantly improved as compared with the conventional observer-based method tracking time-varying parameters. In the proposed scheme, the disturbance voltage caused by the dead time is effectively estimated and compensated by on-line basis without any additional circuits nor existing disadvantages as in the conventional methods. The asymptotic stability is proved and the effectiveness of the proposed scheme is verified.

A New On-line Dead-Time Compensation Method Based on Time Delay Control Technique

  • Kim Hyun-Soo;Kim Kyeong-Hwa;Youn Myung-Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.155-159
    • /
    • 2001
  • In this paper, an on-line dead-time compensation method based on a time delay control approach is presented. The disturbance voltages caused by the dead time are estimated in an on-line manner by the time delay control without any additional circuits and off-line experimental measurements. And the estimated disturbance voltages are fed to voltage references in order to compensate the dead-time effects. The proposed method is applied to a PM synchronous motor drive system and implemented by using software of a digital signal processor (DSP) TMS320C31. Experiments are carried out for this system and the results well demonstrate the effectiveness of the proposed method.

  • PDF