• 제목/요약/키워드: Daylighting Performance

검색결과 125건 처리시간 0.031초

반사거울 방식을 이용한 중정 내 자연채광 성능 분석 연구 (A Study on Daylighting Performance of an Inner Court with Reflecting Mirror System)

  • 박병윤;최창호
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.112-121
    • /
    • 2011
  • To lead lighting inside, design solution and mechenical solution can be used.A inner court and atrium are samples for design solution. However, physical and environmental elements for building design are not taken positively into consideration. So low position of the inner court is difficult to reach lighting performance and a urban landscape gets damaged. On this study, selecting a building with a inner court, best design method is suggested to apply reflecting mirror. building direction, building shape and solar position are considered to deside the setting angle for reflecting mirror. Performance for the setting reflecting mirror is verified through various simulation cases, and is got more lighting performance than the present situation on the building inside.

실내 건축공간에 있어 수평채광덕트 시스템의 적용에 관한 실험적 연구 (An Experimental Study on the Application of Horizontal Daylight Duct System in Building Interior Space)

  • 이성주;김회서
    • 조명전기설비학회논문지
    • /
    • 제18권1호
    • /
    • pp.36-43
    • /
    • 2004
  • 본 논문은 건축물에 적용할 수 있는 자연채광 시스템으로서 채광부 반사판과 방광부의 위치 및 크기 등을 개선한 수평형 채광덕트를 개발하고자 하였으며, 이에 따른 실물모형 실험을 통하여 채광성능을 분석하고 적용가능성을 검증하고자 하였다. 연구결과 채광덕트의 적용시 청천공 상태에서는 실내 안쪽에서 0.3∼0.4%의 조도비가 측정되었다. 또한 덕트 폭보다 150[cm] 이상 넓은 조도분포를 가지는 것으로 나타났으며, 채광성능이 높아 실제 건물에 적용할 경우 주간시간대에서 조명에너지 절약 가능성이 높은 것으로 판단되었다.

정밀 전천공조도 데이터를 활용한 국내 주요도시 업무용 건물의 자연채광 활용성능 평가 (Evaluation of Daylighting Performance in Office Building with Detailed Global Illuminance Data of Selected Korean Cities)

  • 최수현;신상용;서동현
    • 한국태양에너지학회 논문집
    • /
    • 제36권6호
    • /
    • pp.37-46
    • /
    • 2016
  • In this study, long-term global illuminance data for 19 selected cities are calculated from modeled solar radiation data, AEER's TMY2. Perez model in Daysim daylight simulation tool is used for the solar radiation to illuminance conversion. And then, daylight availability in an unit office space is evaluated for the 19 cities. For this evaluation, various daylight performance indices are reviewed since static daylight performance index such as daylight factor (DF) and annual average global illuminance value is not suitable for actual performance evaluation in terms of visual comfort and light energy saving of a space. This study evaluated daylighting performance of prototypical office space module by introducing DA (daylight autonomy) and UDI (Useful Daylight Illuminance) index for major cities of Korea. Result shows that there is upto 18% of illuminance level difference with annual average global illuminance data, but if we consider useful daylight in a space the illuminance level difference among the cities are only within 5%. This means that for sustainable building design especially in daylight design, amount of annual global illuminance is not important factor even in cloudy cities. Daylight design and daylight harvesting system would return similar energy saving impact regardless of building location.

지하주차장 공간디자인에 관한 연구 - 채광성능 개선을 중심으로 - (Study of the frame in Underground Parking Spaces - Centering on the Improvement of Skylight on Daylighting Performance -)

  • 황민구
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2004년도 춘계 종합학술대회 논문집
    • /
    • pp.461-466
    • /
    • 2004
  • 최근 공동주택의 지하주차장공간들은 지하공간에 위치한 문제를 차치하고도 많은 다양한 환경적 문제를 가지고 있음에도 불구하고 충분치 못한 공간으로 건축되었다. 이 연구는 스케일모델 측정으로 통하여 지하주차공간의 일광채광정도를 살펴보았다. 결과적으로 4%정도의 개구율에서 기준 조도수준에 미치는 적정한 량의 일광이 채광됨을 알 수 있었다.

  • PDF

블라인드를 고려한 여름철 소규모 사무소 건물의 냉방 및 조명에너지 평가 (The Summer Cooling and Lighting Energy Performance Evaluation of Small Office Buildings with Venetian Blinds)

  • 정유근
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.39-45
    • /
    • 2013
  • The daylighting control system has to be applied to prevent the excessive incident daylight and reduce energy use. As the one of the most useful daylighting control systems, the blind system is simple and easy to install on the window for small office buildings. This study aims to evaluate the summer energy performance of small office buildings by venetian blinds and energy saving strategy of ministry of knowledge economy in korea. For the study, the simulations have been executed on blind installation conditions and lighting control methods. As results, the energy loads cut down 22 to 25(%) by using blind energy. Also, the efficient shows high on EMS system and low on $45^{\circ}$ slat angles. Also, using energy saving strategy can reduce about 13(%) energy load.

건물에너지성능기준 강화 이후 국내공공기관 업무용 건축물의 디자인경향 (A Study on Design Tendencies in Office Buildings of Public Institutions after Reinforcement of the Building Energy Performance Criteria in Korea)

  • 이아영
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.139-149
    • /
    • 2011
  • This study focuses on design tendencies in office buildings of public institutions after tightening up Korea's building energy performance criteria. Important office design criteria and recommendations pay attention to the issues such as building orientation, greening buildings, building form, space and envelop by intensifying building energy performance related laws, government guidelines and evaluation systems. The design tendencies explored in this research are as follows. Office buildings mainly face south and have various types of indoor and roof green spaces not for ecological reasons but for the rest. Building depth becomes thinner and atria are inserted into office buildings to improve daylighting and natural ventilation. Building cores are located on north or west and east sides acting as buffer spaces to reduce heat loss and to block solar radiation. Office building envelop design includes various creative ideas to control or utilize solar energy as like three dimensional or double structured skin and window size variation to cope with the intensity of solar radiation. Further, solar energy generation systems are integrated with building component such as roofs, sun screens and windows. This study demonstrates that government's reinforcement of the building energy performance criteria drives the change in design methods and approach.

자연채광용 박막 투광형 BIPV 창호의 발전특성 분석 연구 (Performance characteristics of building-integrated transparent amorphous silicon PV system for a daylighting application)

  • 윤종호;김석기;송종화;이성진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.280-283
    • /
    • 2007
  • The first grid-connected, building-integrated transparent amorphous silicon photovoltaic installation has been operated since October 2004 in Yongin, Korea. The 2.2kWp transparent PV system was applied to the facade of entrance hall in newly constructed KOLON E&C R&D building. The PV module is a nominal 0.98m ${\times}$ 0.95m, 10% transparent, laminated, amorphous(a-Si) thin-film device rated at 44 Wp per module. To demonstrate the architectural features of thin film PV technologies for daylighting application, transparent PV modules are attached to the building envelope with the form of single glazed window and special point glazing(SPG) frames. Besides power generation, the 10% transmittance of a-Si PV module provides very smooth natural daylight to the entrance hall without any special shading devices for whole year. The installation is fully instrumented and is continuously monitored in order to allow the performance assessment of amorphous silicon PV operating at the prevailing conditions. This paper presents measured power performance data from the first 12 months of operation. For the first year, annual average system specific yield was just 486.4kWh/kWp/year which is almost half of typical amorphous silicon PV output under the best angle and orientation. It should be caused by building orientation and self-shading of adjacent mass. Besides annual power output, various statistical analysis was performed to identify the characteristics of transparent thin film PV system.

  • PDF

AVR Microcontroller를 이용한 하이브리드 자연채광시스템의 성능에 관한 기초연구 (A Study on the Performance of a Hybrid Daylighting System Using AVR Microcontrollers)

  • 임상훈;오승진;김원식;정해준;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제35권6호
    • /
    • pp.1-7
    • /
    • 2015
  • This paper deals with the design and operation of a hybrid daylighting system that uses natural and artificial lighting to enhance visual comfort in buildings. The system was developed using an AVR micro controller for solar tracking in conjunction with dimming controls, which, acting together, enables the maximum use of natural daylight and also improves energy efficiency in buildings. Experimental results clearly demonstrates the usefulness of the present system capable of enhancing indoor lighting conditions when sufficient daylight is available and distributed appropriately in harmony with artificial lighting.

자연채광용 Mini-dish 클러스터의 기본설계 및 시제품 제작에 관한 연구 (The Preliminary Design and Fabrication of a Daylighting Device with Mini-dish Cluster)

  • 한현주;김정태
    • KIEAE Journal
    • /
    • 제6권4호
    • /
    • pp.11-16
    • /
    • 2006
  • This work has carried out some preliminary studies for the utilization of a solar mini-dish system capable of concentrating solar rays to higher densities. A typical mini-dish system considered employs an array of solar mini-dishes where major components are light and compact. It consists of small mini-dishes, optical fiber bundles and diffusers at the end. Each mini-dish (typically has a 20 to 30 cm in diameter) is designed with a simple parabolic profile, concentrating sunlight (after the glass glazing cover to avoid dust deposition on the reflector and facilitate cleaning) onto a centrally-located small mirror which is placed on the bottom side of the transparent glass cover. The focused sunlight is reflected by the mirror surface onto a focal point where the receiving aperture of a homogenizer is located. Optical fibers are used to carry high-density solar rays to the other end where diffusers are mounted for indoor illumination. The proposed high density mini-dish system could make an efficient daylighting system as it excludes large moving parts and expandable if necessary. Each component of the system could be made from the off-the-shelf technology and thus, make the generic unit inexpensive to manufacture. Depending on spatial demand or characteristics, the amount of introducing daylight could be controlled. Preliminary tests have been carried out for a trial system to check any functional problems when in operation. Suggestions are also made to improve the design enhancing its performance and applicability.

주광연동 제어설비를 이용한 청공광의 경제성 평가 (Economic Feasibility Analysis on the Benefit of Daylighting Incorporation Devices under Clear Skies)

  • 김곤;김정태
    • 설비공학논문집
    • /
    • 제19권7호
    • /
    • pp.491-499
    • /
    • 2007
  • An architectural means of optimal daylight distribution is by using so-called light shelf systems, horizontal shading and redirecting devices. The overall performance of the daylighting system can be improved by the incorporation with electric lighting control devices. This paper aims to exemplify the benefit of daylighting in term of economic consideration. In such a case a reasonable technique to compare system costs is by life-cycle costing. Stated simply, a life-cycle cost represents the total cost of a system over its entire life cycle, that is, the sum of first cost and all future costs. Four different electric lighting system designs are proposed and a lighting control system that is continuously operating according to the level of daylight in the space has been adapted. The result shows clearly that although denser layout of lighting fixtures might be more effective to interface to the level of daylight ceaselessly changeable, its economic benefit may not meet the expected criterion the reason of increased initial investment and maintenance cost for the fixtures and control devices.