• Title/Summary/Keyword: Daily output

Search Result 196, Processing Time 0.025 seconds

Studies on the Correlation between Sodium Chloride Metabolism and Blood Pressure of Koreans (한국사람의 뇨중식염배설량과 혈압과의 상호관계에 관한 연구)

  • Kim, Ku-Ja
    • The Korean Journal of Physiology
    • /
    • v.8 no.2
    • /
    • pp.19-31
    • /
    • 1974
  • In oder to study the correlation between daily urinary output of sodium chloride and blood pressure, twenty four hour urine samples were collected from 224 cases (70 male and 154 female) of healthy Koreans whose age varied from 18 to 70 years old. The volume and concentration of sodium, chloride and potassium and total nitrogen were measured, along with the resting blood pressure. Results obtained are summarized as follows; 1. Daily urinary output was increased as a function of age. However, daily urinary output per unit sulface area was maintained at approximately 800 to 900 $ml/m^2$ in all age groups of male and it increased as a function of age in female groups. There was no significant difference between male and female. 2. The daily urinary sodium concentration was decreased gradually acceding to age in both sexes. Daily excretion of sodium was constant regardless of age in both sexes but especially high in 25-39 year female age group, which was slightly greater in males than in females. 3. The daily urinary chloride concentration was at approximately 250 meq/L in all age groups of male and which decreased as a function of age in females. 4. Hence the daily urinary output of sodium chloride was constant in all age groups of males which increased as a function of age in female groups. However, daily excretion of sodium chloride per unit sulface area was maintained at approximately 11 $gm/m^2$ in males and which increased as a function of age in females. 5. The daily urinary excretion of potassium was constant regardless of age in both sexes. 6. Urinary K/Na ratio was maintained at approximately 0.27 in males and 0.33 in females. 7. The daily urinary output of total nitrogen amount was approximately $8{\sim}10$ gm in males and $7{\sim}9$ gm in females. However, daily urinary output of nitrogen per unit sulface area was constant regardless of age in both sexes. 8. The systolic blood pressure was increased gradually according to the age in both sexes and was higher for males than females under 40 years of age. However, there was no significant difference between both sexes in ages over 40 years. 9. Quantitative comparisons indicated that daily urinary output and sodium chloride excretion are higher while daily potassium output, nitrogen excretion and urinary K/Na ratio are significantly lower among Koreans than a among Occidentals. These findings suggest that average Koreans live on low-protein and high-salt diet throughout their livers. Statistical result obtained may he summarized as follows; 10. The relation between blood pressure and sodium concentration of urine. The correlation between systolic blood pressure and sodium concentration was negatively associated for both sexes and the correlation coefficient was significant for females $({\gamma}_1=-.19<-{\gamma}_{152},\;_{0.05}=-0.159)$ and it was not significant for males $({\gamma}_1=-.19>-{\gamma}_{68},\;_{0.05}=-0.232)$ tut may be due to the sample size for males. The correlation between diastolic blood Pressure and sodium concentration was negatively associated for both sexes and the correlation coefficient was significant for males $({\gamma}_1=-.37<-{\gamma}_{68},\;0.05=-0.232)$ and the relation was not significant for females $({\gamma}_1=-.11>-{\gamma}_{152},\;_{0.05}=-0.159)$. 11. The relation between blood pressure and daily urinary sodium chloride excretion. The association between systolic blood pressure and sodium chloride excretion was positively correlated for both sexes and the relation was significant for females $({\gamma}_1=.20>{\gamma}_{152},\;_{0.05}= 0.159)$ and it was insignificant for males $({\gamma}_1=.09<{\gamma}_{68},\;_{0.05}=0.232)$, The relation between diastolic blood pressure and sodium chloride excretion was positively associated and insignificant for both sexes males $({\gamma}_1=.17<{\gamma}_{68},\;_{0.05}=0.232)$ and females $({\gamma}_1=.09<{\gamma}_{152},\;_{0.05}=0. 159)$. 12. The relation between daily urinary nitrogen excretion and sodium chloride excretion. The association between daily nitrogen excretion and sodium chloride excretion was positively significant for both sexes, males $({\gamma}_1=.31>{\gamma}\;_{68},\;_{0.05}=0.232)$ and females $({\gamma}_1=.36>{\gamma}_{-152},\;_{0.05}=0.159)$.

  • PDF

Daily check device manufacture and efficiency Evaluation for daily Q.A (일일 정도관리를 위한 Daily check device 의 제작 및 효율성 평가)

  • Kim Chan Yong;Je Yeong Wan;Lee Je Hui;Park Heung Deuk
    • 대한방사선치료학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.19-22
    • /
    • 2005
  • Introduction: Daily Q.A is the important step which must be preceded in a radiation treatment. Specially, radiation output measurement and laser alignment, SSD indicator related to a patient set-up recurrence must be confirmed for a reasonable radiation treatment. Daily Q.A proceeds correctness and a prompt way, and needs an objective measurement basis. Manufacture of the device which can facilitate confirmation of output measurement and appliances check at one time was requested. Methods and Materials: Produced the phantom formal daily check device which can confirm a lot of appliances check (output measurement and laser alignment, field size, SSD indicator) with one time of set up at a time, and measurement observed a linear accelerator (4 machine) for four months and evaluated efficiency. Result: We were able to confirm an laser alignment, field size, SSD indicator check at the same time, and out put measurement was possible with the same set up, so daily Q.A time was reduced, and were able to confirm an objective basis about each item measurement. As a result of having measured for four months, output measurement within ${\pm}\;2\%$, and measured laser alignment, field size, SSD indicator in range within ${\pm}\;1mm$. Conclusion: We can enforce output measurement and appliances check conveniently and time was reduced and was able to raise efficiency of business. We were able to bring n cost reduction by substitution expensive commercialized equipment. Further It is necessary to makes a product as strong and slight materials, and improve convenience of use.

  • PDF

Development of a Daily Electricity Business Index by using the Electricity Daily Data of the Manufacturing Sector (제조업 일별 전력 사용량을 활용한 일일전력경기지수(DEBI) 개발)

  • Oh, Seunghwan;Park, Sungkeun
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.41 no.3
    • /
    • pp.59-74
    • /
    • 2016
  • Electricity sales are directly measured from individual consumers, which could minimize the time gap between data collection and public announcement. Furthermore, industrial electricity sales are highly linked with production and output. Therefore, industrial electricity consumption can be used to track production and output in real time. By using the high-frequency data of industrial electricity sales, this study develops the daily electricity business index (DEBI) to capture the daily economic status. The steps used to formulate DEBI are as follows: (1)selection of the explanatory variables and period, (2) amendment of the seasonal adjustment to eliminate daily temperature and effective day effects, (3) estimation of the weighted value via variables by using PCA, (4) calculation of DEBI and commencement of validation tests. Our empirical analysis and the Hodrick-Prescott filter analysis show that DEBI is highly related to existing economic indices.

Study on the Dose Characteristics of the PTW-LinaCheck Dosimeter and Its Application to Daily Output Measurement (PTW-LinaCheck 측정기의 선량 특성과 일일 출력측정 응용에 관한 연구)

  • Jeong, Dong-Hyeok;Lee, Kang-Kyoo;Moon, Un-Chul;Kim, Hyun-Jin;Kim, Young-Seok;Moon, Sun-Rock
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.56-62
    • /
    • 2008
  • In this study, we have investigated the dose characteristics of PTW-LinaCheck designed to detect output of medical LINAC and discussed clinical use of the detector. The reproducibility, linearity, and dose rate dependency of the dosimeter were measured for photons of 6 and 15MV and the electrons of 4, 6, 9, 12, and 16MeV. To know the error ranges of the measured data in daily output measurement, the response variations due to geometrical setup errors were measured. As a result of measurement, the error range from the geometrical setup and the reproducibility was less than ${\pm}0.6%$ for given beam qualities in daily output measurement, where the errors from the linearity and the dose rate dependency were negligible. Finally, we concluded that the LinaCheck dosimeter has a good characteristics in terms of dose and setup convenience in daily output measurement. In addition we have shown an examples of clinical use of this dosimeter for measuring daily output more than 60 days.

  • PDF

A Study on Fluid Intake and Output Measurements (수분 섭취 및 배설량의 측정방법에 관한 연구)

  • Choi, Smi;Yang, Young-Hee;Jung, Yun
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.1
    • /
    • pp.88-98
    • /
    • 1995
  • The Fluid and electrolytes balance in the body is of critical importance in maintaining good health. When the fluid and electrolyte imbalance is present, patients are in great danger. They must be assessed immediately by a nurse so that appropriate treatment can be started as soon as possible. Patients' fluid intake and output records contain highly important information for the diagnosis and treatment of fluid imbalance, but, these records are often inaccurate and the method of recording the fluid intake is not universal for every hospital. Be-cause they are few quantitative measurements of a patient's hydration, the need to improve the accuracy of fluid intake records is very important. However, very few studies have been done to investigate the accuracy of measurements of patients' fluid intake and output. The purpose of this study was to investigate the methods used for calculation of fluid intake which is most similar to fluid output in normal adults and hospitalized patients. This study focused on three different calculation methods for fluid intake and compared these to fluid output and developed suggestions as to the ideal way to record fluid in-take. Data for 43 hospitalized patients and 37 normal adults were analyzed. The findings of this study are as follows ; 1) In normal adults, the daily intake of water which enteres by the oral route was 2415m1 (the first method of calculation). The daily intake of water in the form of pure water or some other beverage was 1365m1 (the third method of calculation) The daily intake of water including fresh fruits and vegetables, rice, porridges, and Me m which have water content more than 80% were 2186m1 (the second method of calculation). 2) The urine output of the normal adults was 1350m1. This apprroximates the amount of fluid an adult takes in the form of pure water. 3) In patient group, the total intake of water was 2550m1 (the first method of calculation). The in-take of water in the form of pure water or as some other beverage and IV fluid was 1661m1 (the third method of calculation). The daily in-take of water including foods which have high water content was 2356m1 (the second method of calculation). 4) The urine output of the patient's group was 1728m1. This approximates the amount of fluid an adult takes in the form of pure water. 5) Investigation of the method of calculation of the patient fluid intake showed that among the 31 hospitals studied, only eight use the third method of calculation which reflects the most close value to urine output. From the results obtained in this study, it was indicated that the amount of fluid taken in the form of pure water reflects the most close value to urine output. Therefore, it can be suggested that the third method of calculation which includes water in-take only in the form of pure water or beverage should be used as patients' fluid intake record.

  • PDF

The Usefulness Assessment of Verifying Daily Output by Using CHECKMATE$^{TM}$ (CHECKMATE$^{TM}$를 이용한 일일 출력 검증의 유용성 평가)

  • Cho, Han-Sang;Nam, Sang-Soo;Park, Hae-Jin;Kim, Mi-Hwa;Park, An-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • Purpose: In this study, we tried to check the usefulness of two Linear Accelerators, Clinac IX and 21EX (Varian, Palo Alto, CA), which are equipped in Ajou Medical Center. From 2008 to 2010, we evaluated the error range of Absolute Dose based on the daily output, which was measured by CHECKMATE$^{TM}$ (Sun Nuclear, Melbourne, FL). Materials and Methods: For Daily Q.A, photon beams of two linear accelerators, 21EX and IX (6 MV and 10 MV, respectively) were measured daily by using CHECKMATE$^{TM}$ just before the treatment began, while the absolute dose was measured biweekly by using water phantom. We analyzed the data of measured values from the daily Q.A and the absolute dose from 2008 to 2010 for 21EX, and from 2009 to 2010 for IX. We utilized Excel 2007 (Microsoft, USA) to evaluate Average, Standard deviation and Confidence level of the data. Furthermore, in order to check the measured values of CHECKMATE$^{TM}$ and the significance of absolute dose, each error value was compared and analyzed. Results: During the observation period, the output of two equipment's absolute dose increased in process of time and in both 6 MV and 10 MV, there was a similar increasing trend. In addition, the error rate of the measured value of CHECKMATE$^{TM}$ and the value of absolute dose were under 0.34, which means that there is a similarity relationship between the two measured values. After checking that the measured value of CHECKMATE$^{TM}$ increased, We measured the absolute dose to adjust that. When the error range was close to 2~3%, the number of changing the output was four for 21EX and three for IX. Conclusion: As a result of measuring and analyzing the daily output changes for two years by using CHECKMATE$^{TM}$, we could find that there is a significance between the output which we should obey during Q.A, and the measured value of absolute dose within the error tolerance of 2~3%. Thus, the use of CHECKMATE$^{TM}$ can be positively considered for more efficient and reliable daily output verification of linear accelerator. It can also be a good standard for other medical centers to understand the trends of linear accelerator and to refer to for the correction of each output.

  • PDF

Assessment of the usefulness of the Machine Performance Check system that is an evaluation tools for the determination of daily beam output (일간 빔 출력 확인을 위한 평가도구인 Machine Performance Check의 유용성 평가)

  • Lee, Sang Hyeon;Ahn, Woo Sang;Lee, Woo Seok;Choi, Jin Hyeok;Kim, Seon Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.65-73
    • /
    • 2017
  • Purpose: Machine Performance Check (MPC) is a self-checking software based on the Electronic Portal Imaging Device (EPID) to measure daily beam outputs without external installation. The purpose of this study is to verify the usefulness of MPC by comparing and correlating daily beam output of QA Beamchecker PLUS. Materials and Methods: Linear accelerator (Truebeam 2.5) was used to measure 10 energies which are composed of photon beams(6, 10, 15 MV and 6, 10 MV-FFF) and electron beams(6, 9, 12, 16 and 20 MeV). A total of 80 cycles of data was obtained by measuring beam output measurement before treatment over five months period. The Pearson correlation coefficient was used to evaluate the consistency of the beam output between the MPC and the QA Beamchecker PLUS. In this study, if the Pearson correlation coefficient is; (1) 0.8 or higher, the correlation is very strong (2) between 0.6 and 0.79, the correlation is strong (3) between 0.4 and 0.59, the correlation is moderate (4) between 0.2 and 0.39, the correlation is weak (5) lower than 0.2, the correlation is very weak. Results: Output variations observed between MPC and QA Beamchecker PLUS were within 2 % for photons and electrons. The beam outputs variations of MPC were $0.29{\pm}0.26%$ and $0.30{\pm}0.26%$ for photon and electron beams, respectively. QA Beamchecker PLUS beam outputs were $0.31{\pm}0.24%$ and $0.33{\pm}0.24%$ for photon and electron beams, respectively. The Pearson correlation coefficient between MPC and QA Beamchecker PLUS indicated that photon beams were very strong at 15 MV, and strong at 6 MV, 10 MV, 6 MV-FFF and 10 MV-FFF. For electron beams, the Pearson correlation coefficient were strong at 16 MeV and 20 MeV, moderate at 9 MeV and 12 MeV, and very weak at 6 MeV. Conclusion: MPC showed significantly strong correlation with QA Beamchecker PLUS when testing with photon beams and high-energy electron beams in the evaluation of daily beam output, but the correlation when testing with low-energy electron beams (6 MeV) appeared to be low. However, MPC and QA Beamchecker PLUS are considered to be suitable for checking daily beam output, as they performed within 2 % of beam output consistency during the observation. MPC which can perform faster than the conventional daily beam output measurement tool, is considered to be an effective method for users.

  • PDF

Manufacture of Versatile Phantom for the Daily Quality Assurance of Radiation Therapy Equipments (방사선치료 장비들의 매일 정도관리를 위한 다용도 모형의 제작)

  • Cha, Dong-Soo;Lee, Jae-Seung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.59-64
    • /
    • 2010
  • We examined the accuracy and efficiency of phantom by applying the designed phantom in order to check daily quality assurance easily by objective criteria and to confirm daily quality assurance of linear accelerator, simulator, and CT-simulator. The results of 10 weeks of linear accelerator output dose using American Association of Physicists in Medicine(AAPM) daily quality assurance guide were measured within ${\pm}1%$ of error. Mechanical check of laser alignment, optical distance indicator(ODI), CT scanner laser and alignment of gantry lasers with the center of imaging plane were measured within ${\pm}1mm$. Daily average working time for daily quality assurance of radiation therapy equipments was 38 minutes. The designed phantom was easy to install and daily quality assurance was possible with only one installation. The aspects reproducibility and efficiency as well as accuracy of quality assurance were excellent.

  • PDF

Studies on Sodium Chloride and Nitrogen Metabolism of the Korean (한국인(韓國人)의 식염(食鹽) 및 질소대사(窒素代謝)에 관(關)하여)

  • Chung, Soon-Tong;Yang, Il-Suk
    • The Korean Journal of Physiology
    • /
    • v.1 no.2
    • /
    • pp.193-197
    • /
    • 1967
  • In order to study the daily metabolism of sodium chloride and of nitrogen, 24 hour urine samples were collected from 298 normal Korean males whose ages varied Iron 26 to 80 years old. The volume and the concentration of chloride and the total nitrogen were determine, along with the resting pulse and the blood pressure. The daily urine volume was maintained at approximately $1,000\;ml/m^2$ in all age groups while the chloride concentration was at approximately 230 mEq/l. Hence the daily urinary output of sodium chloride was estimated to be approximately 21 gm. On the other hand, the daily urinary output of total nitrogen amounted to approximately 10 gm. Theses findings are similar to those obtained earlier by Yi et al. (1966) in Korean subjects younger than 25 fears old, indicating that average Koreans live on low protein and high salt diets throughout their life. Despite a known correlation between the incidence of hypertension and the high salt intake, none of the these subjects employed in the present investigation showed any sign of hypertension.

  • PDF

A Study on Fluid Intake Measurements (수분 섭취량 측정법에 관한 연구)

  • Lee, Chang Kwan;Kim, Yu Kyung;Seo, Myung Hwa;Lee, Kyung Mee;Lee, Ju Eun
    • Korean Journal of Adult Nursing
    • /
    • v.25 no.5
    • /
    • pp.567-573
    • /
    • 2013
  • Purpose: The purpose of this study was to compared two methods for measuring fluid intake and to assess the most effective method. Methods: Data from 44 hospitalized patients with chronic kidney disease was analyzed. Two methods were used. The liquid method is to measure the daily intake of water in the form of pure water or some other beverage and IV fluid, the liquid-solid method is to measure the daily intake of water which enters by the oral route and IV fluid. Results: The daily intake of fluid was 1483.10mL and 2245.99mL respectively. The fluid output was 1883.72 mL. The Intra-Class Correlation (ICC) between the liquid method and the liquid-solid method and fluid output was 0.64 and 0.69, respectively. The correlation between differences of fluid in two methods and body weight change was r=.47 (p<.001) and r=.56 (p<.001), respectively. Conclusion: The results of this study suggest that there are no difference between the two measuring methods as to reflecting the most close value to fluid output. And the difference between intake and output by two methods is correlated with body weight change. Therefore, it can be suggested that the either method could be useful as patients' fluid intake measurement.