• 제목/요약/키워드: DWELL TIME

검색결과 238건 처리시간 0.036초

분말야금법으로 제조된 FeSi2 열전특성 화합물의 열처리 시간에 따른 미세조직과 상변화 (Phase Transformation and Microstructure of FeSi2 Thermoelectric Compounds Manufactured by Powder Metallurgy)

  • 박경태;신진교;홍순직;천병선
    • 한국분말재료학회지
    • /
    • 제17권6호
    • /
    • pp.482-488
    • /
    • 2010
  • In this study, $FeSi_2$ as high temperature performance capable thermoelectric materials was manufactured by powder metallurgy.The as-casted Fe-Si alloy was annealed for homogenization below $1200^{\circ}C$ for 3 h. Due to its high brittleness, the cast alloy transformed to fine powders by ball-milling, followed by subsequent compaction (hydraulic pressure; 2 GPa) and sintering ($1200^{\circ}C$, 12 h). In order to precipitate ${\beta}-FeSi_2$, heat treatment was performed at $850^{\circ}C$ with varying dwell time (7, 15 and 55 h). As a result of this experiment thermoelectric phase ${\beta}-FeSi_2$ was quickly transformed by powder metallurgical process. There was not much change in powder factor between 7h and 55h specimens.

고선량율 근접치료의 정도관리 (Quality Assurance for High Dose Rate Brachytherapy)

  • 방동완;조정희;박재일
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.30-44
    • /
    • 1998
  • Accurate delivery of doses using a high dose rate(HDR) brachytherapy, remote afterloading system(RALS) depends on knowing the strength of the radioactive source at the time of treatment, the precision and consistency of the timer, and the ability of the unit to position the source at the proper dwell location along the applicator. Periodic Quality Assurance(QA) on HDR machines is a part of the standard protocol of any user. The safety of the patient & staff, positional accuracy, temporal accuracy, and dose delivery accuracy are periodically(weekly, quarterly, monthly) estimated using HDR source(Ir-192), treatment planning devices, measurement devices, and overall treatment devices with regard to treatment delivery. The overall measurement results are estimated successfully and assessed its clinical significance. As a result, our HDR brachytherapy units has been very accurate until now. The QA program protocol permits routine clinical use and provides a high confidence level in the accurate operation of HDR units. Therefore, regular QA of HDR brachytherapy is essential for successful treatment.

  • PDF

고선량 Ir-192선원 교정기의 제작 및 특성 (High Dose Rate Ir-192 Source Calibration Method with Newly Designed Calibration Jig)

  • 이병용;최은경;장혜숙
    • Radiation Oncology Journal
    • /
    • 제7권2호
    • /
    • pp.299-303
    • /
    • 1989
  • Authors have developed highly reproducible calibration method for the Micro-Selectron HDR Ir-192 system (Nucletron, Motherland). The new jig has a 10cm radius circular hole in the $30cm{\times}30cm{\times}0.2cm$ acrylic plate, and 5F flexible bronchial tubes are attached around the hole. The source moves along the circle in the tubes and the ionization chamber is placed verticaly at the center of the circular hole (center of the jig). Dose distribution near the center was derived theoretically, and measured with the film dosimetry system. Theoretical calculation and measurement show the error margin below $0.1\%$ for 1mm or 2mm position deviation. We have measured at 12 and 24 points of circle with 1, 6, 11 and 21 second dwell time of source in order to calculate the activity of the source. Measurements have been repeated daily for 50 days. The accuracy and the reproducibility are below $1\%$ error margin. The half life of the source from our measurement is estimated $73.4\pm0.4$ days.

  • PDF

PZT 세라믹 레조네이터 무연솔더 접합부의 열-기계적 피로 가속수명 (Accelerated Thermo-Mechanical Fatigue Life of Pb-Free Solder Joints for PZT Ceramic Resonator)

  • 홍원식;박노창;오철민
    • 한국재료학회지
    • /
    • 제19권6호
    • /
    • pp.337-343
    • /
    • 2009
  • In this study, we optimized Pb-free Sn/Ni plating thickness and conditions were optimized to counteract the environmental regulations, such as RoHS and ELV(End-of Life Vehicles). The $B_{10}$ life verification method was also suggested to have been successful when used with the accelerated life test(ALT) for assessing Pb-free solder joint life of piezoelectric (PZT) ceramic resonator. In order to evaluate the solder joint life, a modified Norris-Landzberg equation and a Coffin-Manson equation were utilized. Test vehicles that were composed of 2520 PZT ceramic resonator on FR-4 PCB with Sn-3.0Ag-0.5Cu for ALT were manufactured as well. Thermal shock test was conducted with 1,500 cycles from $(-40{\pm}2)^{\circ}C$ to $(120{\pm}2)^{\circ}C$, and 30 minutes dwell time at each temperature, respectively. It was discovered that the thermal shock test is a very useful method in introducing the CTE mismatch caused by thermo-mechanical stress at the solder joints. The resonance frequency of test components was measured and observed the microsection views were also observed to confirm the crack generation of the solder joints.

FIB-CVD의 가공 공정 특성 분석 (The Analysis of Chemical Vapor Deposition Characteristics using Focused Ion Beam)

  • 강은구;최병열;홍원표;이석우;최헌종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.593-597
    • /
    • 2005
  • FIB equipment can perform sputtering and chemical vapor deposition simultaneously. It is very advantageously used to fabricate a micro structure part having 3D shape because the minimum beam size of ${\phi}$ 10nm and smaller is available. Currently FIB is not being applied in the fabrication of this micro part because of some problems to redeposition and charging effect of the substrate causing reduction of accuracy with regards to shape and productivity. Furthermore, the prediction of the material removal rate information should be required but it has been insufficient for micro part fabrication. The paper have the targets that are FIB-CVD characteristic analysis and minimum line pattern resolution achievement fur 3D micro fabrication. We make conclusions with the analysis of the results of the experiment according to beam current, pattern size and scanning parameters. CVD of 8 pico ampere shows superior CVD yield but CVD of 1318 pico ampere shows the pattern sputtered. And dwell time is dominant parameter relating to CVD yield.

  • PDF

중국 경제의 급부상에 따른 부산항의 발전전략 (The Development Strategies of the Port of Busan in the Midst of Rapidly Growing Chinese Economy)

  • 배병태
    • 한국항만경제학회지
    • /
    • 제18권2호
    • /
    • pp.109-133
    • /
    • 2002
  • The China entered World Trade Oganization(WTO) last year, thus opening its border to more - and freer - trade. With its foreign trade rapidly expanding and with economic growth continuing at a substantial -rate, China will be the largest container traffic generating country in the world. In the light of this potential trade bonanza, regional ports in North-East Asia strive to gain a competitive-edge. The Port of Busan, the world's third largest container port, wants to capture a significant share of the china's container cargoes. In this circumstance, development strategies of the Port of Busan are suggested as follows. First, to cope with increasing volumes, the New Busan Port on Gaduk island should be constructed without failure. Second, it is necessary to add modernized high-performance gantry cranes and to train crane operators' skill. Third, it needs to apply Dwell Time- Sliding Scale System for transshipment cargoes. Fourth, it needs to develop the EDI network in terminal areas or adjacent hub ports to exchange trustworthy and satisfactory informations Fifth, port authority -needs to enlarge designated Free Trade Zone to facilitate the free flow of cargoes. Sixth, the restoration of rail links between North and South Korea is abundantly clear. Thus it needs to enlarge railroad facilities in advance. Seventh, it needs to establish the Port Authority of Busan immediately. Finally, it needs to strengthen port sales and to open events like 'Marine Week 2001' regularly to attract potential canters or big shippers.

  • PDF

산화철 나노입자의 브라운 운동에 대한 자기장 의존성 연구 (Magnetic Field Dependence of Brownian Motion in Iron-oxide Nanoparticles)

  • 정은경;윤석수;김동영
    • 한국자기학회지
    • /
    • 제26권1호
    • /
    • pp.13-18
    • /
    • 2016
  • 유기 용매에 고르게 분산되어 있는 26 nm 크기의 산화철 나노입자를 사용하여 주파수에 따른 교류 자화율을 측정하였다. 자기장이 없는 조건에서 측정한 나노입자의 자화율은 Debye 완화 모델로 계산한 결과와 일치하였으며, 완화 주파수(relaxation frequency)는 370 Hz였다. 나노입자의 완화 주파수는 용매의 점성에 의한 브라운 운동(Brownian motion)의 완화 시간과 일치하였다. 브라운 운동에 의한 나노입자의 완화 주파수는 자기장의 세기에 따라 선형적으로 증가하는 특성을 보였다.

인적요인에 의한 도시철도 출입문 끼임사건 분석 (Analysis of Traps Incidents of Metro Train Door by Human Factors)

  • 박태영;오현수;장성록
    • 한국안전학회지
    • /
    • 제33권6호
    • /
    • pp.85-92
    • /
    • 2018
  • This study aimed to reduce of traps incident of metro train door by suggesting preventive actions throughout analyzing why railway drivers and passengers commit unsafe behaviors which are human factors making occurrence of the incidents. The incident cases were analyzed and Incident Tree was structured by brainstorming with safety experts. In addition, the questionnaire survey was conducted for comparison with the analysis results. As the result, this study suggested driver's factors, passenger's factors, and public relation plan for safe use of metro in order to reduce the frequency of the incidents. For driver's factors, implementing job-rotation systems between railway and non-railway drivers, installing Object Detection Sensors between the metro doors and PSD, and flexible operation of dwell time were suggested. For passenger's factors, placing a platform safety person, installing a safety fence in front of the stairs and the elevators, and country wide public relations through mass media were suggested.

도시철도 열차 승하차시간 분석에 관한 연구 (An Analysis of Boarding and Alighting Times for Urban Railway Vehicles)

  • 김정태;김무선;홍재성;조용현;김태식
    • 한국철도학회논문집
    • /
    • 제17권3호
    • /
    • pp.210-215
    • /
    • 2014
  • 도시철도의 표정속도를 증대시키기 위해 여러 가지 방안이 연구되고 있는데 출입문 폭 확장을 통한 정차시간 단축은 이러한 방안 중 하나이다. 그러나, 출입문 폭을 확장하였을 때 단축되는 승객 승하차시간을 예상하기 위해 적합한 국내 모델과 수식은 아직 수립되지 않은 형편이다. 승하차 동작은 사람의 행동 방식에 영향을 많이 받고 이는 국가 별로 상이하다는 점을 고려한다면 승하차시간에 대한 외국 모델을 따른 다는 것은 적합하지 않다. 본 연구에서는 국내에서 측정 및 실험한 데이터를 바탕으로 국내 환경에 적합한 모델을 세우고 관련 수식과 변수를 유도함으로써 출입문 폭 확장 시 승하차시간 단축효과를 예상할 수 있도록 한다.

센서네트워크에서의 프록시 트라젝토리 기반 데이터 저장 기법 (An Proxy Trajectory Based Storage in Sensor Networks)

  • 임화정;이헌길
    • 정보처리학회논문지C
    • /
    • 제15C권6호
    • /
    • pp.513-522
    • /
    • 2008
  • 센서네트워크에서 데이터를 효율적으로 전송하는 것은 매우 중요한 문제이다. 수집된 데이터를 외부의 저장소나 시스템에 저장하기보다는 센서네트워크 내에 있는 노드들에 직접 저장하는 데이터 중심 저장소 기법은 높은 접근성을 제공할 수 있다. 센서네트워크에서 사용되는 데이터 저장소 기법을 사용하면 데이터를 외부 저장소로 전송하기 위한 지연시간과 에너지 낭비없이 실시간으로 수집된 데이터에 접근할 수 있다는 것이다. 그러나 데이터를 저장하는 일부 노드에 질의가 집중될 경우 질의에 대한 응답시간이 길어질 수 있으며, 부하집중으로 노드의 에너지가 빠르게 고갈되어 네트워크 수명이 단축될 수 있다. 본 논문에서는 질의를 처리하는 저장소 노드에 발생하는 부하를 주위의 여러 노드들로 분산시켜 질의에 대한 응답지연시간을 줄이고, 사용자의 이동성을 지원하는 프록시개념의 프록시 트라젝토리를 형성하는 프록시 트라젝토리 저장기법(APT)기법을 제안한다. 시뮬레이션을 통하여 제안기법의 노드별 질의 응답시간의 단축과 응답 홉 수의 감소를 검증하였다.