• Title/Summary/Keyword: DR (Digital Radiography)

Search Result 89, Processing Time 0.027 seconds

A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System (Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구)

  • Hong, Sun Suk;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.247-253
    • /
    • 2013
  • The purpose is a comparative evaluation in the DR System according to the dosimetry and image quality of the quantitative and objective via Direct digital radiography, Indirect digital radiography, Image intensifier (Charge Coupled Device type) digital radiography. The experimental method used rando phantom and measured the entrance surface dose. And through using the measured entrance surface dose and then using the PCXMC program were evaluated risk due to irradiation and the effective dose. SNR and NPS and CNR were measured and analyzed by using 21cm acryl phantom. Significance of measured value was evaluated by statistics method. Entrance surface dose, major organ dose, effective dose all of them were measured the lowest rated in direct DR when it is on the basis of direct DR dose, high-dose ratio were measured in I.I DR approximately 1.3 times, indirect DR approximately 2.4 times. Risk in accordance with radiation also was measured same as dose ratio. On the conclusion that SNR measurement result based on direct DR SNR measurements, low-SNR ratio were measured in I.I DR approximately 7.25 times, indirect DR approximately 1.48 times. On the conclusion that CNR measurement result based on direct DR CNR measurements, high-dose ratio were measured in I.I type DR approximately 1.16 tims and low-dose ratio were measured in indirect DR approximately 0.87 times. Therefore Direct DR system using a-selenium sensing element to detect x-ray photon is thought effectively at the examination such as infant to sensitive irradiation and the genital gland. Because quality image is built by low dose. Also when it is necessary that image test requiring many diagnosis information, indirect DR system is thought effectively.

Evaluation of the Patient Dose in Case of Standard Radiographic Examinations Using CR and DR (표준영상의학검사를 대상으로 한 CR과 DR에서의 환자선량평가)

  • Kim, Sang-Tae;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.173-178
    • /
    • 2010
  • In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and digital radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Department of Radiology our hospital, a flat-panel DR equipment (Digital diagnost, Philips) and two CR systems (ADC Compact plus digitizer, AGFA) are employed. Eight standard radiographic examinations (Skull AP, Skull LAT, Chest PA, Chest LAT, Abdomen AP, L-spine AP, L-spine LAT, Pelvis AP) were considered: doses delivered to patients in terms of both entrance skin dose (ESD) were calculated and compared in order to study the dosimetric discrepancies between CR and DR. Assessment of image quality is undertaken by Consultant Radiologists to ensure that the quality criteria for diagnostic radiographic images of the European guidelines were met. Results showed that both ESD in DR are lower than that in CR; all images met the criteria in the European Guidelines for both modalities and were used for reporting by the radiologists. Since the operators are the same and the image quality is comparable in both modalities, this study shows that in the considered examinations, DR can perform better than CR from a dosimetric point of view.

The Comparison of Image Quality between Computed Radiography(CR) and Direct Digital Radiography(DDR) which Follows the Proper Exposure Conditions in General Photographing under the Digital Radiography (Digital Radiography 환경하에서 일반촬영시 적정노출조건에 따른 CR과 DDR의 Image Quality 비교)

  • Kim Jin Bae;Kang Chung Hwan;Kang Sung Jin;Park Soo In;Park Jong Won;Kim Yeong Su
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.22-34
    • /
    • 2001
  • DR은 방사선과 뿐만 아니라 병원전체의 생산성 및 업무의 효율성에서 중요한 요소로 자리잡아가고 있다. DR환경은 CR보다 다양한 Parameter를 가지고 있어 양질의 의료서비스 제공이 가능하다. 현재 각 병원의 방사선과는 Film-Screen system에서 Full-PACS를 통한 DR 환경으로 변화하고 있다. Full- PACS를 사용하고 있는 본원에서는 DR환경에서의 일반촬영 System중 CR과 DDR의 최적노출조건과 그에 따른 Image qu

  • PDF

A Quality Assurance on Digital Chest Radiography in Medical Institution for Pneumoconiosis : Compared with Analog Radiography (진폐요양기관의 흉부 디지털촬영과 아날로그촬영의 정도관리 비교)

  • Lee, Won-Jeong;Ko, Kyung-Sun;Park, Jai-Soung;Kim, Sung-Jin;Chu, Sang-Deok;Park, So-Young;Choi, Byung-Soon
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.85-91
    • /
    • 2010
  • Digital radiography has been replacing rapidly the analog radiography for diagnosis of pneumoconiosis. The purpose of this study is to compare quality control of digital radiography (DR) and analog radiography (AR) for chest radiography in medical institution for pneumoconiosis (MIP) For the first time, we visited MIP to evaluate the chest radiography which is used for patients with pneumoconiosis, including equipment, technical parameters and reading environment. There were 33 institutions. DR and AR were installed in 24 and 9 institutions, respectively. Between DR and AR, we compared the radiological technique (RT), image quality (IQ) and reading environment (RE) to use the guideline published by Occupational Safety and Health Research Institute (OSHRI). The image quality was rated by two experienced chest radiologists for pneumoconiosis with certified from OSHRI. The chest radiography equipment was not significantly difference between AR and DR, but there were significantly difference in tube voltage and grid ratio used for chest radiography except to tube current, exposure time. Statistically, DR is significantly higher in RT(70.3 vs. 43.8, p = 0.009), RE(77.7 vs. 33.3, p = 0.004) than AR, but it's not significantly difference in IQ (65.6 vs. 52.8, p = 0.050). AR and DR in RT were passed 33.3%, 75.0% respectively (p = 0.044) and 44.4%, 79.2% (p = 0.090) in IQ and 44.4%, 91.7% (p = 0.009) in RE. In MIP, DR needs to replace AR in diagnosis of pneumoconiosis.

DR Image Enhancement Using Multiscale Non-Linear Gain Control For Laplacian Pyramid Transformation (라플라시안 피라미드에서의 다중스케일 비선형 이득 조절을 이용한 DR 영상 개선)

  • Shin, Dong-Kyu;Lee, Jin-Su;Kim, Sung-Hee;Park, In-Sung;Kim, Dong-Youn
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.199-204
    • /
    • 2007
  • In digital radiography, to improve the contrast of digital radiography image, the multi-scale nonlinear amplification algorithm based on unsharp masking is one of the major image enhancement algorithms. In this paper, we used the Laplacian pyramid to decompose a digital radiography(DR) image. In our simulation, the DR image was decomposed into seven layers and the coefficients of the each layer was amplified with nonlinear function. We also imported a noise containment algorithm to limit noise amplification. To enhance the contrast of image, we proposed a new adaptive non-linear gain amplification coefficients. As a result of having applied to some clinical data, a detail visibility was improved significantly without unacceptable noise boosting. Images that acquired with the proposed adaptive non-linear gain coefficients have shown superior quality to those that applied similar gain control method and expected to be accepted in the clinical applications.

Physical principles of digital radiographic imaging system (디지털 방사선영상 시스템의 기본적 원리)

  • Choi, Jin-Woo;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.155-158
    • /
    • 2010
  • Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray exposure to the patient. This article reviewed the basic physical principles of digital radiographic imaging system in dental clinics generally. Digital radiography can be divided into computed radiography (CR) and direct radiography (DR). CR systems acquire digital images using phosphor storage plates (PSP) with a separate image readout process. On the other hand, DR systems convert X-rays into electrical charges by means of a direct readout process. DR systems can be further divided into direct and indirect conversion systems depending on the type of X-ray conversion. While a direct conversion requires a photoconductor that converts X-ray photons into electrical charges directly, in an indirect conversion, lightsensitive sensors such as CCD or a flat-panel detector convert visible light, proportional to the incident X-ray energy by a scintillator, into electrical charges. Indirect conversion sensors using CCD or CMOS without lens-coupling are used in intraoral radiography. CR system using PSP is mainly used in extraoral radiographic system and a linear array CCD or CR sensors, in panoramic system. Currently, the digital radiographic system is an important subject in the dental field. Most studies reported that no significant difference in diagnostic performance was found between the digital and conventional systems. To accept advances in technology and utilize benefits provided by the systems, the continuous feedback between doctors and manufacturers is essential.

A comparative study for resolution and density of chest imaging using film/screen, CR and DR (X-ray 흉부영상 FIlm/Screen, CR, DR Resolution과 Density 비교평가)

  • An, Byeong-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • The objective of this study was to compare the resolution and density appropriate to diagnosis in chest PA radiography. In comparing the resolution, we radiographed with conventional radiography, computed radiography(CR) and digital radiography(DR) using the linear resolution phantom(Nuclear Associates-Carle Place. N.Y.). 2 radiologists and 3 radiological technologists read the resolution value by the blind test. DR, conventional radiography and CR measured 3.95, 3.58, 3.48 resolution value respectively. In analysing the density, we chose the fifty normal chest CR and DR and conventional film. We estimated the density using by densitometer(X-rite company-Model 301) in seven regions(lung field, lung field margine, mediastinum I, mediastinum II, heart shadow I, heart shadow II, diaphragm) of chest film. We adapted to analysis the Japanese chest X-ray evaluating method and table. It was scored 0(farthest density value) to 2(nearest density value). DR scored 2 at mediastinum I, mediastinum II, heart shadow I, heart shadow II and diaphragm. On the contrary with, CR scored 2 at lung field and lung field margine. Consequently, DR superior than CR and conventional radiography film compairing density and resolution. It was due to small pixel size and post processing algorithm with digital radiography.

Quantitative Analysis and Comparison of DR and CR image quality (CR과 DR 영상화질의 정량적 비교분석)

  • Park, Hey-Suk;Seo, Jang-Yeon;Jeong, Jin-Hwa;Lee, Chang-Lae;Cho, Hyo-Min;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.31-37
    • /
    • 2007
  • The purpose of this research was to compare and analyze image quality for each Detector of CR(Computed Radiography) and DR(Digital Radiography). The results showed that CR(AGFA MD 4.0 General plate, JAPAN) was superior to DR(HOLOGIC nDirect Ray, USA) based on the quantitative values and comparison of MTF(Modulation Transfer Function), NPS(Noise Power Spectrum), Photon fluence and DQE(Detective Quantum Efficiency) which have been widely accepted for the estimation of CR and DR. Quantitative evaluations of CR and DR system were obtained and they may be very helpful for QA and QC of general X-ray systems.

  • PDF

Investigation of Physical Imaging Properties in Various Digital Radiography Systems (다양한 디지털 방사선 시스템의 물리적 영상 특성 조사)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Yoon, Yong-Su;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.363-370
    • /
    • 2017
  • We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.

Research for The Environmental Optimization of Dose and Image quality in Digital Radiography (디지털 방사선촬영 환경에서 선량의 최적화 및 영상품질에 대한 연구)

  • Lee, Kwang Jae;Kim, MinGi;Lee, Jong Woong;Kim, Ho Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.203-209
    • /
    • 2013
  • Digital Radiography (DR) has improved a quality of resolution based on a wide dynamic range, high detective quantum efficiency (DQE), and modulation transfer function (MTF), compared with film/screen(F/s). Unlike expectation that a low level of radiation can be used in examination, high level of signal to noise ratio(SNR) due to over-exposure caused increase of exposed dose to patients. Also, the auto exposure control (AEC) using Kilovolage(kVp) in F/S can cause over-exposure. Hence, in this study, we proposed a proper method for using DR, in which effect of tubing Kilovolage on device's image, DR MTF measurement with changes of tubing current (mA), and the quantitative evaluation of skull phantom captured images' PSNR were evaluated. Changes of contrast with tubing Kilovolage can be improved by retouching, and MTF changes according to tubing current(1.41~1.39 lp/mm in 50% area, and 3.19~2.8 lp/mm in 10% area) does not influence on resolution of image. As a result, high tubing Kilovoltage, and tubing current will be suitable to use of DR.