• Title/Summary/Keyword: DLMS

Search Result 31, Processing Time 0.032 seconds

DLMS SCADA System based on TETRA (TETRA 기반 DLMS 원방감시 시스템)

  • Song, Byung-Kwen;Lee, Suk-Hee
    • Journal of IKEEE
    • /
    • v.13 no.3
    • /
    • pp.95-102
    • /
    • 2009
  • TETRA(TErrestrial Trunked RAdio) is wireless communication system generally adopted to public network and backbone network, as the technology of Trunked Radio System specified by ETSI(European Telecommunications Standards Institute) and currently adopted to the Electric Power IT Backbone Network in Korea. DLMS(Device Language Message Specification) is used in order to meter an electric measuring instrument value. In this paper, DLMS Server and Client simulator are used based on Window operating system. The multi-functional gateway, which transforms the communications based on RS-232C between DLMS Server Simulator and Client Simulator to the one based on TETRA PEI(Peripheral Equipment Interface), is developed such that DLMS SCADA(Supervisory Control And Data Acquisition) system is constructed based on TETRA.

  • PDF

The Development of IEC62056 based Energy Information Concentrator for DLMS Meters (DLMS 계량기를 위한 IEC62056기반의 Energy Information 중계장치 개발)

  • Im, Chang-Jun;Jang, Seong-Jin;Hahn, Kwang-Soo;Kim, Byung-Seop;Jung, Nam-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.54-56
    • /
    • 2007
  • DLMS(Device Language Message Specification) 메시지 규약과 COSEM(Companion Specification for Energy Metering) 오브젝트 모델링 기법을 채택한 계량기 통신 및 오브젝트 모델 표준인 IEC62056은 계량기의 상호 운용, 관리, 보안 그리고 계략 데이터 모델링에 대한 방법 등을 기술하고 있으며 TCP-UDP, GPRS, PSTN등의 원격 접속을 위한 프로파일을 지원하고 있다. 본 논문에서는 DLMS계량기의 계량 데이터를 수집 및 관리하는 IEC6056 기반의 energy information concentrator(이하 EIC)를 제안한다 이 중계장치는 COSEM 오브젝트로 구성되어 있는 DLMS 계량기를 EIC의 논리장치로 모델링하여 등록 관리하는 새로운 개념의 DLMS 중계장치이다. 쉽게 말해서 IEC62056을 따르는 DLMS 클라이언트에서 EIC를 바라볼 때 여러 개의 논리 장치를 가지는 DLMS 장치로 인식이 된다. EIC는 특성상 기능적으로 크게 두 부분으로 나누어지는데, 상위 시스템과의 인터페이스를 담당하는 서버부분과 계량기로부터 데이터를 수집하는 클라이언트 부분이다. 서버 부분은 계량 데이터 오브젝트 관리 모듈 부분과 TCP/IP서버 모듈로 나누어지며 클라이언트 부분은 DLMS 계량기 스케줄링 부분과 DLMS 클라이언트 부분으로 나누어진다. 개발된 EIC는 최대 111대까지의 계량기를 지원 관리할 수 있으며, 각 1Mbit 용량의 오브젝트를 구성 할 수 있다.

  • PDF

Wireless Repeating Interference Cancellation Using Singed-DLMS Adaptive Algorithm (Signed-DLMS 적응 알고리즘을 이용한 무선 중계 간섭 제거기)

  • Yoo, Tae-Hoon;Woo, Dae-Ho;Kim, Ju-Wan;Ha, Sung-Hee;Van, Ji-Hun;Lee, Jong-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.343-344
    • /
    • 2007
  • In this paper, we study the signed-DLMS adaptive algorithm of wireless repeater for solving shadow region due to propagation between base station and mobile station. The the signed-DLMS algorithm reduces interference signals from multipath and solves the oscillation problem of repeater by estimation and cancellation. To efficiently reject interference signal, the signed-DLMS adaptive algorithm is applied. The computational complexities of the signed-DLMS are reduced verse standard LMS algorithm. Wireless ICS repeater based on signed-DLMS reduces the cost and is able to increase channel capacities.

  • PDF

Modeling of Power Information based on DLMS/COSEM for Electronic Energy Meter (DLMS/COSEM에 기반한 전자식 전력량계의 전력정보 모델링)

  • Oh, Jung-Hwan;Lee, Young-Joo;Park, Jae-Seong;Kim, Byung-Seop;Cho, Seon-Ku;Lee, Jin
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.114-116
    • /
    • 2006
  • 본 논문에서는 DLMS/COSEM에 기반하여 전자식 전력량계의 전력정보를 모델링하는 방법을 제안 하였다. 유효/무효 전력량, 수요전력, 역률 등의 전력정보를 서술하였으며, 이러한 전력정보를 DLMS/COSEM에 기초하여 모델링하는 방법을 서술하였다.

  • PDF

The study on the design method for DLMS/COSEM meter S/W using Meter Configuration Script (Meter Configuration Script를 이용한 DLMS/COSEM 계량기 S/W 설계 방법에 대한 연구)

  • Im, Chang-Jun;Hahn, Kwang-Soo;Kim, Byung-Seop;Kim, Jong-Bae;Jung, Nam-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.108-110
    • /
    • 2006
  • 계량기의 시장이 독점 시장에서 자유 시장으로 천이 되면서 시장은 계량기의 상호운용능력과 계량기의 지능, 관리능력 그리고 보안등의 부가적인 기능들을 요구 하게 되었다. 이러한 시장의 요구에 맞추어 DLMS 프로토콜을 표준으로 하고 COSEM 오브젝트 모델링 기법을 사용하는 계량기 표준인 IEC 62056이 제정되었다. 본 논문에서는 IEC 62056에서 정의한 프로토콜 및 서비스에 적합한 DLMS/COSEM 계량기의 S/W 아키텍처 및 그 설계 방법을 제안한다. 계량기 S/W는 크게 MCS와 MOM으로 구성되며, MCS는 계량기의 모델링 스크립트로 COSEM 오브젝트와 계량기의 구체적인 기능을 명시하고, MOM은 MCS를 읽어 계량기를 구동 시키는 모듈로 MCS에서 선언된 기능 및 동작을 해석하여 계량기를 전기, 가스, 수도 등의 기능을 갖는 계량기로 동작시키는 역할을 한다.

  • PDF

Almost-Sure Convergence of the DLMS Algorithm (DLMS 알고리즘의 수렴에 관한 연구)

  • Ahn, Sang Sik
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.9
    • /
    • pp.62-70
    • /
    • 1995
  • In some practical applications of the LMS Algorithm the coefficient adaptation can be performed only after some fixed delay. The resulting algorithm is known as the Delayed Least Mean Square (DLMS) algorithm in the literature. There exist analyses for this algorithm, but most of them are based on the unrealistic independence assumption between successive input vectors. Inthis paper we consider the DLMS algorithm with decreasing step size .mu.(n)=n/a, a>0 and prove the almost-sure convergence ofthe weight vector W(n) to the Wiener solution W$_{opt}$ as n .rarw. .inf. under the mixing unput condition and the satisfaction of the law of large numbers. Computer simulations for decision-directed adaptive equalizer with decoding delay are performed to demonstrate the functioning of the proposed algorithm.m.

  • PDF

The Integrated SCADA Data Gateway Platform based on SmartGrid (스마트 그리드 기반 통합 SCADA Data Gateway 플랫폼)

  • Song, Byung-Kwen
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.140-145
    • /
    • 2014
  • OPC UA(IEC62541) is a communication protocol for SG(Smart Grid) application platform. It was standardized by IEC TC57 group in December 2012. The IEC61850 has been used in Digital Substation Systems and Smart Distributed Systems. The DNP3.0 has been used for device's data collection/control in Distributed Systems. The DLMS/COSEM has been used to control metering and collect information in the Smart Metering. The top-level SG management platform needs an independent middleware to manage transparently the Power Information Technology, including the IEC61850, DNP3.0, DLMS/COSEM. In this paper, we propose the SDG(Scada Data Gateway) platform. It manages Power Information Technology based Digital Substation Systems and Smart Distributed systems, Smart Metering through OPC UA.

DLMS Traffic Monitoring System base on HDLC Protocol (HDLC 프로토콜 기반 DLMS 트래픽 모니터링 시스템)

  • Song, Byung-Kwon;Kim, Sae-Byuk;Kim, Kyeong-Hun;Jeong, Tae-Eui;Kim, Jin-Cheol;Kim, Yeong-Eok
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06d
    • /
    • pp.491-494
    • /
    • 2008
  • 기존의 전력량계의 원격 검침을 위한 DLMS/COSEM(Device Languag Message Specification / Companion Specification for Energy Meters) 시스템에서의 실제 송, 수신되는 데이터를 수집하여 이를 표현 및 분석 할 수 있는 프로그램을 구현하여 이로 하여금 실제 검침원에게 시스템에서의 송 수신되는 데이터의 흐름을 한 눈에 볼 수 있게 하였다. 또한 데이터의 실제 값 들을 분석하여 이틀을 가시적으로 볼 수 있어 오류 발생 시에 세부적으로 데이터를 분석하여 오류 원인을 찾아 낼 수 있다.

  • PDF

Power IT System Integration Platform based on OPC (OPC 기반 전력 IT 시스템 연동 플랫폼)

  • Song, Byung-Kwen;Kim, Geon-Ung
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.33-40
    • /
    • 2010
  • OPC is open connectivity in industrial automation and the enterprise systems that support industry. OPC XML-DA provides a platform-independent on web service-based communication. This paper propose Power IT system integration platform using OPC that is to integration between DLMS protocol used in AMI system and Distribute protocol DNP3.0 throught IEC61850 using Substation Automation Protocol.

Case Study on Auto Meter Reading Protocol Certificate System for Smart Grid and Standardization (스마트 그리드를 위한 원격검침 표준 프로토콜 인증 시스템 구축과 표준화에 관한 연구)

  • Choi, In-Ji;Park, Byung-Seok;Choi, Hyo-Yeol;Myung, No-Gil;Lee, Sang-Youm
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.1B
    • /
    • pp.75-85
    • /
    • 2012
  • In this paper, we introduce the case study on the certificate system for Auto Meter Reading protocol, Device Language Message Specification which is a common language between metering devices and protocol with compatibility and conformance to the IEC 62056 standards. KEPCO has contributed to improve interoperability between different devices of multi vendors through the DLMS standard tests and led the smart metering industry in Korea. KEPCO has AMR system and successful business model for 550 thousands of households based on 24Mbps broadband powerline communications using its infrastructure. We have plan to continue on standardization activities stratagemically by participating in IEC working groups for the purpose of occupying the core technology of Smart Gird.